Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 CrAccepted-AOC | ₹12.7 Cr Quoted ₹12.8 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹13.2 CrRejected-AOC PLOT NO 178 A MLA COLONY ROAD NO 12 BANJARAHILLS HYDERABAD HYDERABAD TELANGANA 500034 | HYDERABAD | TELANGANA | 500034 | ₹13.2 Cr | L2 | Rejected-AOC Not being L1 |
| 3 | L3₹13.9 CrRejected-AOC NOT SPECIFIED | ₹13.9 Cr | L3 | Rejected-AOC Not being L1 |
| 4 | L4₹17.7 CrRejected-AOC NO 60 ELDAMS ROAD TEYNAMPET CHENNAI TAMIL NADU 600 018 | CHENNAI | CHENNAI | TAMIL NADU | 600018 | ₹17.7 Cr | L4 | Rejected-AOC Not being L1 |
Tender Value
₹12.9 Cr
EMD Value
₹9.7 L
Closing Date
5 Jul 2024, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 D C Area MES Road
PROVISION OF DEFICIENT MD ACCN FOR JWO AND SGT AT AFS TAMBARAM
2024_MES_649453_1
801577/E8
Open Tender
Civil Works
600 days
GE (AF) TAMBARAM
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE (AF) TAMBARAM
₹9.7 L
Yes
22 Jul 2024
5 Apr 2024
12 Jul 2024
5 Apr 2024
5 Jul 2024
21 Jun 2024
6 Apr 2024 - 15 Apr 2024
Amount
BOQ Dated 28 May 2024
GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to XIII are prepriced by MES under Ser No. 1 to 12. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “Internal Electric Supply" as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “Site Clearance and Area Development” as listed in Schedule ‘A’ Part – IV.
Lumpsum price worked out by the contractor for “Road / Path / Culvert " as listed in Schedule ‘A’ Part V .
Lumpsum price worked out by the contractor for "Sewage Disposal" as listed in Schedule ‘A’ Part VI .
Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part – VII.
Lumpsum price worked out by the contractor for “Rain water harvesting” as listed in Schedule ‘A’ Part – VIII.
Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – IX.
Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – X.
Lumpsum price worked out by the contractor for “DG Set” as listed in Schedule ‘A’ Part – XI.
Lumpsum price worked out by the contractor for “Lightning Protection” as listed in Schedule ‘A’ Part – XII.
Lumpsum price worked out by the contractor for “Fire Fighting and Fire Alarm System” as listed in Schedule ‘A’ Part – XIII.
Sch 'A' Part - XIV : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLY Supply and fix 15mm bore angular stop cock, chromium plated, fancy type, screwed down, screwed for CPVC pipe complete all as directed.
INTERNAL ELECTRIC SUPPLY Supply and fix modular TV socket one module complete all as specified and as directed.
Supply and fix modular telephone socket RJ-11 one module complete all as specified and as directed.
Material and labour for telephone wiring with unarmoured solid annealed bare copper industrial cable in concealed of size 0.5mm, 3 pair with PVC conduit 25mm dia complete all as specified and as directed.
Material and labour for TV wiring with unarmoured coaxial cable RG-11 in concealed with PVC conduit of 25mm dia complete all as specified and as directed.
Material and labour for mild steel box for telephone wiring including blocks suitable for 35 pair complete all as specified and as directed.
Earthing complete with galvanised iron earth plate electrode of size 600 mm X 600 mm X 6.3 mm thick buried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including GI wire 4 mm dia and GI protection pipe 15 mm dia and light grade connected to and including by means of nuts, bolts check nuts and washers made of copper as shown in Plate No. 3 of SSR Part 1 to the extent applicable to this item including necessary excavation, earth work, PCC 1:3:6 chamber RCC 1:2:4 cover 50 mm thick with 6 mm TMT bar 100 mm center to center watering pipe medium grade 20 mm bore funnel wire mesh etc and testing on completion all as specified and as directed.
EXTERNAL WATER SUPPLY Construction of valve chamber of size 900mm x 900mm x 900mm (inner dimension) all as detailed in drawing AFB/TD/056 Sht 1/2 & 2/2, with 100mm thick PCC foundation 1:4:8 type D2, brick masonry built in CM 1:6, 15mm thick internal and external plaster in CM 1:4, external plaster to a depth of 150mm below ground level as also the valve chamber floor, MS sheet cover 3.15mm thick including flat iron framework of FI 40mm x 6mm and 100mm thick PCC coping of 1:2:4, type B1, using 20mm graded aggregate with FI hinge, locking arrangement, handles etc and painting steel surfaces with one coat of red oxide primer and two coats of synthetic enamel black paint complete including necessary excavation in any type of strata and removal of surplus soil to a distance not exceeding 50m, complete all as specified and as directed.
Material and labour for cutting of existing 100mm CI pipe line and for taking 80mm dia branch connection, inserting and including Tee of size 100x100x80 mm, necessary joints, jointing materials excavation earth work complete as required at site all as directed.
Supply, install and testing Electric driven, 415 volts three phase, Monoblock pump set 5 HP, 3.7 KW, total head 30 Mtr, LPS 5.35 Ltrs suction and delivery line pipe dia 80/50 mm including DOL -Three phase starter panel with meters, MU-G-10, Single phase preventer & over loaded relay including base frame PCC platform as per manufactures design complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY Material and labour for returning and filling of trenches in two parts:- (i) using riddled soil obtained from excavated soil up to depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and as directed. Note: Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS-1255-1983 and refilling in trenches as in cable cushioning
Supply, installation, commissioning and testing of LT Feeder Pillar Box, Cubical type weather /dust vermin proof CPRI tested of suitable size, both side opening double door with push type metal lock heavy duty wide hinges separate common across cable aley made out of 3.15 mm CRCA sheet with powder coated painting, angle iron frame of size (50x50x6mm) and MC channel of size (75mmx40mm) for panel base outdoor type free standing cubical type totally enclosed weather dust and vermin proof with front and rear opening with locking arrangement of 440 volts 3 phase 4 wire 50 Hz having copper bus bar capacity 400 Amps with IP 65 protection with copper bus bar RYB duly insulated complete/ bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel,danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following all as specified and as directed by Eng – in-Charge. Incoming: (i) MCCB, 4 pole, 415 V, adjustable type, 200 Amps, with breaking capacity, 3.5 KA -01 Nos. Outgoing : (ii) MCCB 4 pole , 415 V adjustable type 125 Amps with breaking capacity 25 KA-03 Nos , (iii) MCCB 63 Amps, 25 KA, 4 pole, adjustable type, 415 volts-01 No Complete panel wiring including combined digital voltmeter/Amps meter/Frequency meter, set of LED indicator lamp with toggle switch RYB-01 set.
Material and labour for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick buried directly in ground earth pit not less than 2.25 m deep below normal ground level with the top edge of earth plate at a depth of not less than 1.5 m below normal ground level connected to galvanised iron earth strip 32x6 mm as earth lead by means of bolts, nuts, check nuts and washers made out of galvanised iron and galvanised earth strip protected by 40 mm bore light grade galvanised iron pipe as well as watering by 20 mm dia medium grade pipe 1.5 mtr fixed with funnel and wire mesh as specified and connected all as shown in electrical plate No 3 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1:3:6 type C1 chamber and RCC cover (grade M-15) with 8 mm dia TMT steel bars at 100 mm centre to centre both ways hooks, charcoal dust, salt etc as shown on plate No.3 of SSR Part -I complete all as specified and as directed.
Supply, installation, commissioning and testing of LT Feeder Pillar Box, Cubical type weather /dust vermin proof CPRI tested of suitable size ,both side opening double door with push type metal lock heavy duty wide hinges separate common across cable aley made out of 3.15 mm CRCA sheet with powder coated painting, angle iron frame of size (50x50x6mm) and MC channel of size (75mmx40mm) for panel base outdoor type free standing cubical type totally enclosed weather dust and vermin proof with front and rear opening with locking arrangement of 440 volts 3 phase 4 wire 50 Hz having copper bus bar capacity 400 Amps with IP 65 protection with copper bus bar RYB duly insulated complete/ bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel,danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following all as specified and as directed by Eng – in-Charge. Incoming: (i) MCCB, 4 pole , 415 V, adjustable type, 125 Amps, with breaking capacity , 35 KA -01 Nos. Outgoing : (ii) MCCB 4 pole , 415 V adjustable type 63 Amps with breaking capacity 25 KA-03 Nos , (iii) On load charge over switch 415 volt 4 pole capacity 63 Amps-02 complete panel wiring invluding combined Digital voltmeter/Amps meter/Frequency meter, set of LED indicator lamp with toggle switch RYB-01 set
HOT WATER SYSTEM Supply and fix electric water heater storage type compact ABC plastic body design with superioir PUF insulation & single weld line tank with copper heating element upto 2KW capacity 25Litre, BEE 5 star rated complete all accessories like safety valve, thermostat, NRV, connection pipe etc complete all as specified and as directed with the following Parameters:- (i) Rated power input -2000Wt (ii) Heating element - Incology glass coated (iii) Color Changing LED (iv) Hidden Digital Display (v) Feather touch panel (vi) Remote control (vii) Max Hot Water Output Tem in Deg (750 'C') (viii) Rated pressure in Mpa - 0.8 Warranty:- (i) Comprehensive - 2 years (ii) Heating Element - 4 years (iii) Inner Container - 7 years
SMART METER Design, installation, testing, commissioning, integrate and maintain the Advanced metering infrastructure (AMI) Comprising of following:- (a) Supply, installation, testing, commissioning of smart meter AC single phase, two wire, 240 volts, 50Hz, 10 to 60 amps of different makes (not more than 33% of a particular make to ensure interchangeability at a later date as per BIS 16444 with communication technology including GPRS / RF / Hybrid (GPRS+RF) any other advanced technology as per CEA/TRAI regulations). (b) Supply / planning / setup/ tuning of RF communication infrastructure including Network Management (NMS) & Head End system (HES) for the project area. AMI software and associated equipment should be capable of handling atleast 10000 number of meters of different makes as per BIS 16444 with 25% expansion without any additional infrastructure and cost implication to MES. (c) Supply and setup of Meter Data Management (MDM) System. (d) Integration of different devices of different makes/equipment/softwares covered in scope of this project with each other as per functional requirement, including water charges, furniture and license fee. (e) Integration/ interface of the AMI system with application system like metering/billing/collection, interface has to be provided in the proposed solution to upload and process meter data from these systems.
(f) Server for housing and management of supplied software application with Standby server (OR) hosting the system to government community cloud in place of server for hosting and management of supplied software application with standby server. (g) Planning, deployment & tuning of communication system including cellular network (if required) to meet the performance requirements. (h) Business intelligence, Analytics and Reporting. (j) Taking down & Return of dismantled materials to MES Store. (k) Training and knowledge transfer. (l) All expenditure including periodic charges of telecom operator from installation till completion. (m) Comprehensive operation and maintenance of AMI system including project implementation & management, all expenditure including periodic charges of telecom operator, smart meter billing and maintenance, for a period of 10 years post completion of work.
DG SET Supply, Install, Test and commissioning of Acoustic Proof AMF type diesel engine driven generating set fully wired 415V + 5% AC 3 phase, 4 wire 50HZ having capacity 50 KW, 62.5 KVA, Standard control panel & AMF Panel suitable for 1 E.B service (panel B) continuous rating power factor 0.8 (lagging) connections as per IE rule. DG set mounted on a common base plate with anti vibration pad mounting including necessary earthwork and RCC foundations complete all as specified and as recommended by manufacturer. The DG set shall consist of the followings:-
(A). Diesel Engine: The engine should be four cylinders, liquid cooled, turbocharged with after cooler, developing 83 Hp @1500 RPM 4R810TA G1 is in line, electric start compression ignition, 4 stroke designed to run continuously at 1500 RPM confirming to IS -3046,BS5514 standard. Diesel Engine will comply with present CPCB-II norms. The diesel engine will comprise following :- (a) Dry Type air cleaner (b) Exhaust silencer suitable for canopy (residential type) (c) Expansion bellow(d)Lube oil cooler (e) Lube oil Filter (f) Fuel filter (g) Radiator type pusher type fan and mounting (h) in- line mono block fuel injection pump (i) Mechanical governor and fuel pump (j) Flywheel with starter ring and bell housing suitable for coupling (k)12 Volt electric starter motor (l) Battery charging alternator (m) Microprocessor based KG640 Controller mounting on the controller panel (n) protection system for -low lube oil pressure, high water temperature complete all as specified and directed. (B). Alternator: The alternator shall be designed for 50 KW/ 62.5 KVA Alternator , suitable for continuous operation rated at 1500 RPM 415 Volt,08 PF, 50Hz,3 pin in SPDP enclosure ,self -excited & self -regulated, brush less, floor mounted with ball or bearing on end shields. the alternator confirms to IS477, BS EN 60034-1 &will be suitable for tropical condition etc complete all as specified. Make: KIRLOSKAR(KOEL) / CROMPTON GREAVES (C) Electric System: The electric system of the starter motor and charging alternator shall have the following components:- (i) Charging alternator 12 V, DC (ii) Voltage regulator built in type IC regulated (iii). Starter motor 12 volts DC (iv). Battery 12 volts DC and capacity 100 AH including connecting terminals with electric type float cum boost battery charger (D). Fuel tank : The fuel tank capacity 150 ltr shall be included as per manufacturer standards including fuel level indicator fuel line from tank to engine arrangement for fuel filling fuel drain out facility etc complete as specified. (E) Canopy Dimension in (mm):- L:2908 W:1100 H;1835 with silencer tril pipe
(F). AMF Control panel: Automatic Mains Failure (AMF) control panel shall be able to start up the DG set and transfer the load on to the DG set on mains failure without requiring any human intervention. Similarly on restoration of mains supply it shall be able to transfer the DG set automatically along with provision of by pass arrangements of main supply. The AMF panel shall be with in enclosure having IP-53 degree of protection conforming to IS: 13947 (Part-I) 1993 fabricated from minimum 1.6mm thick CRCA sheet steel duly pre treated and aesthetically finished and shall be dust and vermin proof. The AMF panel shall have the following accessories:-
FIRE FIGHTING AND FIRE ALARM SYSTEM Supply and fix 65 mm Y type strainer with flanges and installation necessary accessories all as specified and as directed.
Supply, install, testing & commission of out door LT panel board cubical type weather/dust/ vermin proof CPRI tested factory made outdoor type made out of 3 mm thick CRCA Sheet all as specified in SSR Part-I 2009 and having degree of protection IP-65 with copper bus bar of capacity 100 Amps of duly colour coded and comprising of the following (Main LT Panel) for both building only (i) MCCB- 63 Amps, 25 KA, 4 pole, adjustable type, 415 volts - 01 No (ii) DOL starter for booster Pump-02 No (iv) Multifunctional digital meter (v) Indicating lamp LED type R, Y, B - 01 Set
Fire Alarm System
Supply and fix 4 zone fire alarm control panel complete all as specified and as directed.
Supply and fix Addressable manual call point resettable type all as specified and as directed.
Supply and fix Addressable electronic sounder cum strobe all as specified and as directed.
Supply and Laying on wall /floor/roof 2 core 1.5 Sqmm copper armoured cable complete all as specified and as directed.
Supply and fix 12v, 7 AH Battery all as specified and as directed.
PA SYSTEM
Supply and fix 6 watt wall mount speaker all as specified and as directed.
Supply and fix 6 watt out door cone type speaker all as specified and as directed.
supply and fix steam type Microphone all as specified and as directed.
Supply and fix 160 Watt Amplifier all as specified and as directed.
Supply and fix floor mount rack all as specified and as directed.
Supply and laying of 1.5 Sqmmx2 core FRLS Armoured cable all as specified and as directed.
Integration and evaculation kit
BLANK
Annual NB-IOT, GPRS SIM Charges
Annual Vending Charges per meter per year
Meter Box Single Phase with DP MCB 10KA
SRICO PROJECTS PVT LTD
United Sales Corporation
DANUSH INTERIORS AND CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid