Loading…
Loading…
Updated dates
Tender Value
Refer Docs
EMD Value
₹19,364
Closing Date
8 Jun 2026, 1:00 pm2d left
The Executive Engineer, Kolkata Electrical Div
The Executive Engineer Kolkata Electrical Division P.W.Dte. BlockI (1st Floor)Writers Buildings,Kolkata 700001
Rewiring and renovation work of whole office of Department of Correctional Administration incl.Supply, installation of AC machines at the IT cell room of DCA at 63, N.S Road Jessop Building, 1st floor, Kolkata 700001.Electrical works
2026_WBPWD_5013935_1
WBPWD/EE-KED/eNIT-54/2nd/25-26
Open Tender
ELECTRICAL WORKS ORG
30 days
Jessop Building
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,364
O/O The Executive Engineer Kolkata Electrical Divi
12 May 2026
12 May 2026
10 Jun 2026
12 May 2026
8 Jun 2026
19 May 2026
18 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 3 no. suitable size “Ph & N, E" copper bar attachment fixed on wall incl. mending good damages to original finish. Average run 10 mtr | 100 | Point | - | - |
| 1.2 | on board | 16 | Each | - | - |
| 2Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm/25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required | |||||
| 2.1 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC | 120 | Mtr | - | - |
| 2.2 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC | 700 | Mtr | - | - |
| 2.3 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC for AC machines | 30 | Mtr | - | - |
| 2.4 | 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC(TPNDB to SPNDB) | 200 | Mtr | - | - |
| 3Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required | |||||
| 3.1 | 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC | 60 | Rmtr | - | - |
| 4Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes | |||||