| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-Finance | L1 | Accepted-Finance Rate is lowest | |
| 2 | L2₹31.5 L+₹2.0 L (6.78%)Rejected-Finance | L2 | Rejected-Finance Rate is not lowest |
| Sl No | Description | Qty | Unit | m/s tripathi brothers L2 | M/s Apurv Enterprises L1 |
|---|---|---|---|---|---|
| 1.00fo|qr forj.k [k.M&pkSjhpkSjk] xksj[kiqj ds vUrxZr fctusl Iyku esa Lohd`r ykbu ds xkfMZax ds dk;ksZ dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %& | |||||
| 2.00Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :- | |||||
| 2.01 | PCC Pole 11 Mtr Long. | 166 | No | 850 ₹1,41,100 | 750 ₹1,24,500 Lowest |
| 2.02 | PCC Pole 8.5 Mtr Long. | 32 | No | 850 ₹27,200 | 750 ₹24,000 Lowest |
| 2.03 | ACSR Weasel Conductor | 4 | KM | 2,800 ₹11,200 | 2,500 ₹10,000 Lowest |
| 2.04 | Earthing of Pole by MS earthing Rod of 20X2500 mm | 68 | No | 10 ₹680 Lowest | 10 ₹680 Lowest |
| 2.05 | MS Angle 65X65X6 (1.6 mtr Long) | 105 | No | 15 ₹1,575 Lowest | 15 ₹1,575 Lowest |
| 2.06 | Stay set Complete 16X1800 | 32 | No | 15 ₹480 Lowest | 15 ₹480 Lowest |
| 2.07 | 11 KV V type X arm 65X65X6 mm, MS angle | 182 | No | 10 ₹1,820 Lowest | 10 ₹1,820 Lowest |
| 2.08 | 11 KV Disc Insulator T&C type 4500 Kg | 36 | No | 10 ₹360 Lowest | 10 ₹360 Lowest |
Tender Value
Refer Docs
EMD Value
₹35,000
Closing Date
13 Oct 2025, 4:00 pmClosed
SUPERINTENDING ENGINEER
SE EDC I GORAKHPUR
THE WORK RELATED TO LT/11 KV LINE SANCTIONED UNDER BUSINESS PLAN 2025-26 IN AREAS UNDER ELECTRICITY DISTRIBUTION DIVISION-CHAURI CHAURA, GORAKHPUR
2025_PVVNV_1070432_2
28/EDC-I(G)/2025-26
Open Tender
Electrical Works
Lump-sum
180 days
GORAKHPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SE EDC GORAKHPUR
₹35,000
17 Oct 2025
3 Oct 2025
14 Oct 2025
3 Oct 2025
13 Oct 2025
3 Oct 2025
Amount
fo|qr forj.k [k.M&pkSjhpkSjk] xksj[kiqj ds vUrxZr fctusl Iyku esa Lohd`r ykbu ds xkfMZax ds dk;ksZ dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
PCC Pole 11 Mtr Long.
PCC Pole 8.5 Mtr Long.
ACSR Weasel Conductor
Earthing of Pole by MS earthing Rod of 20X2500 mm
MS Angle 65X65X6 (1.6 mtr Long)
Stay set Complete 16X1800
11 KV V type X arm 65X65X6 mm, MS angle
11 KV Disc Insulator T&C type 4500 Kg
11 KV Disc fitting
MS Channel 125X65X1300 mm (T-off)
Polymeric 11 KV Pin Insulator
Supply of following material/fitting complete in all respect :-
Stay Insulator
Stone Pad (300X300X75 mm)
Stay Clamp
Earthing Clamp
Number Plate with clamp and Nut & Bolt
Eye Bolt
Holding Clamp
Clamps for Top, T-off with bolts & Nuts
Clamps for 11 KV V type X arm with bolts & Nuts
Guarding Angle
Clamps Guarding Angle
Danger Plate with clamp and Nut & Bolt
G.I Nuts & Bolts off size
GI Wire 6 SWG
GI Wire 8 SWG
GI Wire 7/10 SWG (3.15 mm)
F Bracket for 11 KV
Erection of Pole with grouting of pole
Earthing of Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO norms.
Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work)
Erection of Number Plate
Erection of Danger Plate
Laying, stringing, sagging, binding and jumpering of ACSR Weasel/Dog conductor for LT/HT Line with fixing of LT Clamps/other clamps, Shackle insulator and nuts&bolts off size as per required.
Guarding of Line
fo|qr forj.k [k.M&pkSjhpkSjk] xksj[kiqj ds vUrxZr fctusl Iyku esa Lohd`r ykbu ds xkfMZax ds dk;ksZ dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
Guarding X arm MS Angle
Supply of following material/fitting complete in all respect :-
Guarding X arm clamp
G.I Nuts & Bolts off size
GI Wire 6 SWG & 10 SWG
Guarding of Line
fo|qr forj.k [k.M&pkSjhpkSjk] xksj[kiqj ds vUrxZr fctusl Iyku esa Lohd`r oh0lh0ch0 iSuy yxkus ds dk;ksZ dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
11 KV VCB I/C CTR 600/300/5A, (1250 Amp)
11 KV VCB O/G CTR 200/100/5A
Opening of 11 KV cable and other connections Bus bar of existing defective VCB incoming its dismantling and proper shifting by dragging of safe place at S/s and Re-errection of New 11 KV VCB there on after shifting upto errection place of s/s with all connections after errection of 11 kv VCB & doing proper Earthing work and all necessary setting done.
Opening of 11 KV cable and other connections Bus bar of existing defective VCB Outgoing its dismantling and proper shifting by dragging of safe place at S/s and Re-errection of New 11 KV VCB there on after shifting upto errection place of s/s with all connections after errection of 11 kv VCB & doing proper Earthing work and all necessary setting done.
Dismentling & Carriage of old Damaged Panel from work site to store centre
fo|qr forj.k [k.M&pkSjhpkSjk] xksj[kiqj ds vUrxZr fctusl Iyku esa Lohd`r ikoj ifjorZdksa ds lqj{kk ds n`f"Vxr lh0Vh0 LFkkfir djus ds dk;ksZ dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
33 kV CT 400/200/1-1-1 A
33 kV PT (outdoor) (33 KV/110V)
Installation of 33 kV CT 400/200/1-1-1 A
Installation of 33 kV PT (outdoor) (33 KV/110V)
fo|qr forj.k [k.M&pkSjhpkSjk] xksj[kiqj ds vUrxZr fctusl Iyku esa Lohd`r ttZj ,y0Vh0 dsfcy cnyus ds dk;ksZ dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
11 KV Cable 3X185 Sqmm XLPE
Cable Jointing Kit 11 KV 3X185 Sqmm XLPE Cable (Outdoor)
Supply of following material/fitting complete in all respect :-
GI Pipe 6" dia
Socket for GI Pipe 6" dia
Laying of 11 KV 3x185 sq mm XLPE Cable as per RESSPO norms.
Erection of 11 KV XLPE Cable 3X185 mm² Jointing Kit with complete work
Chemical Earthing
fo|qr forj.k [k.M&pkSjhpkSjk] xksj[kiqj ds vUrxZr fctusl Iyku esa Lohd`r fIyaFk ,oa QsfUlax ds dk;ksZ dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Repairing of T/F plinth. All required materials will be provided by the contractor.
Grill fencing of 11/0.4 KV S/S shall be made of rectangular of size & height approx 2 meter as per site requirement with fabrication 50X50X5 mm angel the frame is also have 1 No Horizontal runner of MS flat 40x5 welded in middle to support of grill, having a gate on road side must have provision of locking arrangement. The work is including painting of fencing as per norms. Work will be done as per RESPO specification.
fo|qr forj.k [k.M&pkSjhpkSjk] xksj[kiqj ds vUrxZr fctusl Iyku esa Lohd`r ifjorZdksa ds vfFkZax ds dk;ksZ dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
Earthing of Pole by MS earthing Rod 20X2500 mm
Stay Clamp
Supply of following material/fitting complete in all respect :-
Earthing Clamp
GI wire 6 SWG
Earthing Installation
Chemical earthing for 250 KVA & 400 KVA
fo|qr forj.k [k.M&pkSjhpkSjk] xksj[kiqj ds vUrxZr fctusl Iyku esa Lohd`r yEcs LiSu dks de djus gsrq iksy yxkus ds dk;Z dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
PCC Pole 11 Mtr Long.
PCC Pole 8.5 Mtr Long.
11 KV V type X arm
11 KV Pin Insulator
11 KV Pin with nut
ACSR Weasel Conductor
Earthing Complete
Supply of following material/fitting complete in all respect :-
Stone Pad
Clamp for X Arm
LT Clamp with Nuts & Bolts
LT Shackle Insulator
F Bracket
G.I Nuts & Bolts off size
Erection of Pole with grouting of pole
Earthing of Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO norms.
Laying, stringing, sagging, binding and jumpering of ACSR Weasel/Dog conductor for LT/HT Line with fixing of LT Clamps/other clamps, Shackle insulator and nuts&bolts off size as per required.
fo|qr forj.k [k.M&pkSjhpkSjk] xksj[kiqj ds vUrxZr fctusl Iyku esa Lohd`r cSVªh ,oa cSVªh pktZj yxkus ds dk;Z dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Supply of following material/fitting complete in all respect :-
Battery Set 24 Volt
Battery Charger 24 Volt (Complete Set)
Alu Lug 25 mm
Multicore Copper wire 16 mm Sq.
G.I Nuts & Bolts off size
Installation of Battery and Charger set with complete work
fo|qr forj.k [k.M&pkSjhpkSjk] xksj[kiqj ds vUrxZr fctusl Iyku esa Lohd`r V~;wcyj cSVªh ,oa cSVªh pktZj yxkus ds dk;Z dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Supply of following material/fitting complete in all respect :-
Exide Tubular Battery 200 Ah 2 No, Inverter in 2 KVA 1 No. and Cabinet Stand
Installation of Exide Tubular Battery 200 Ah 2 No, Inverter in 2 KVA 1 No. and Cabinet Stand
m/s tripathi brothers (BID ID -5604056)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .