Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC 1627 SECTOR 26 PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹26.7 L | L1 | Accepted-AOC in order |
| 2 | L2₹27.0 LRejected-Finance 241 SECTOR 7 PANCHKULA | ₹27.0 L | L2 | Rejected-Finance NOT IN ORDER |
Updated dates
Tender Value
₹28.7 L
EMD Value
₹57,315
Closing Date
11 Feb 2026, 12:00 pmClosed
Executive Engineer Roads Division No 1 MC Chd
Executive Engineer Roads Division No 1 MC Chd
REVAMP OF FLOORING BY PROVIDING HIGH DENSITY CHEQUERED TILES IN FRONT OF MARKET/ SHOWROOMS/BOOTHS AND REFIXING PAVER BLOCKS BACKSIDE SCO S IN MARKET OF SECTOR 42,CHANDIGARH
2026_MCC_90172_1
MCC/R1/2026/020
Open Tender
Civil Works
120 days
work
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
₹57,315
22 Apr 2026
21 Jan 2026
11 Feb 2026
21 Jan 2026
11 Feb 2026
21 Jan 2026
Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Taking out existing channel of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.NS
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge DSR 16.83
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer in charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) DSR 15.2.2
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil. DSR 2.6.1
Preparation of sub grade including trenching rough dressing of soil, final dressing of earth to give level and camber, watering, rolling with a road roller and compaction of bed complete in all respect to the entire satisfaction of Engineer in Charge.
Fixing of old kerb after excavating/filling the earth to required level and grade complete in all respect. The rate also includes cost of filling and pointing of joints with cement mortar 1:4 (1 cement : 4 coarse sand).
Providing and fixing PCC kerbs of size 2’-0” x 9” having 4” thickness at bottom and 3” thickness at top and made of plain cement concrete 1:2:4 duly vibrated and compacted. The rates also includes the cost of filling and pointing of joints between kerbs with cement mortar 1:4 (1 cement 4 course sand) Complete in all respect to the entire satisfaction of Engineer In Charge.
Fixing of old channel after excavating/filling the earth to required level and grade complete in all respect. The rate also includes cost of filling and pointing of joints with cement mortar 1:4 (1 cement : 4 coarse sand).
Providing and fixing Precasting plain cement concrete Channel of size 2'-0" x 1'-0" x 3" thick duly mixed, mechanically & compacted made of PCC 1:2:4 duly cured and finished. The rates is to be fixed over 20mm thick cement sand mortar 1:4 including grouting of joints complete in all respect to the entire satisfaction of Engineer -in-charge
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) DSR 4.1.10
Providing & Fixing 25mm thick high Density Chequered Tiles of minimum size 300mm x 300mm of approved design by Engineer Incharge of NTC, NITCO, Sham Tiles make , jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 15 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) :
Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). DSR 16.84
Carriage of material (1.1) by mechanical transport including loading unloading and stacking complete in all respect using appropriate labour and machinery to carry dispose the building rubbish/ malba/ dismantled and wastes to the Municipal Corporation C&D waste processing plant to an average lead of 12 Km and all lifts to entire satisfaction of Engineer in Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 15.94 MB
BOQ_110272.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid