| 1 | L1₹28.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹37.3 L+₹7.5 L (25.3%)Rejected-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-AOC L2 | |
| 3 | L3₹38.7 L+₹8.9 L (29.8%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹40.0 L+₹10.2 L (34.1%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹42.4 L+₹12.7 L (42.5%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 May 2025, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
REPAIR/REPLACEMENT OF INTERNAL WIRING, UNSV LIGHT FITTINGS/FIXTURES, DAY TO DAY MAINT/PETTY REPAIRS TO INTERNAL ELECTRIC FITTINGS, FIXTURES, LUMINARIES, DBS AND OTHER ASSOCIATED ITEMS AT AFS YELAHANKA
2025_MES_706411_1
8375/E8
Open Tender
Civil Works
Item Wise
330 days
Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹90,000
Yes
18 Jul 2025
2 May 2025
6 Jun 2025
2 May 2025
30 May 2025
16 May 2025
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and removing materials to store for keeping in safe custody or for taking into credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed
Taking down the unserviceable MCB DBs & metal clad sockets of any capacity/any type complete all as specified and directed
Taking down the unserviceable MCB of any rating and any size/type complete all as specified and directed
Taking down old unserviceable sub main wiring of any size complete all as specified and directed
M&L for point wiring in PVC casing & capping all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbles complete all as specified and directed for One light/bell / Fan point controlled by one ,one way switch
All as per item No 5 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one-way switch.
All as per item No 5 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one-way switch.
All as per item No 5 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 2.5 Sqmm for continuity earth wire connected to common earth dolly complete all as specified and directed
M&L for point wiring in PVC conduit all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multi stranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbles complete all as specified and directed for One light/bell / fan point controlled by one ,one way switch
All as per item No 9 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one-way switch.
All as per item No 9 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one-way switch.
All as per item No 9 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 2.5 Sqmm for continuity earth wire connected to common earth dolly complete all as specified and directed
M&L for point wiring in PVC concealed conduit as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multi stranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Mark) and screws and rawal plugs including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbles complete all as specified and directed for One light/bell/ fan point controlled by one ,one way switch
All as per item No 13 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one-way switch.
All as per item No 13 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one-way switch.
All as per item No 13 above but for socket out let, 15/16 Amps on independent board with 2.5 Sqmm size cable and 4 Sqmm for continuity earth wire connected to common earth dolly all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 3 module complete all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 4 module complete all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 6 module complete all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 8 module complete all as specified and directed.
S&F Switch modular type single pole one module, 6 Amps complete all as specified and directed
S&F Switch modular type single pole one module, 16 Amps complete all as specified and directed
S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole two module, 6 Amps complete all as specified and directed
S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole two module, 6/16 Amps complete all as specified and directed
S&F Modular bell push single pole one module, 6 Amps complete all as specified and directed
S&F Modular blank plate one module all as specified and directed
S&F Modular type stepped type electronic fan regulator 2 Module 230 Volts complete all as specified and directed
S&F fan speed regulator, electronic step type, suitable for single phase AC, 240 volts, 50 Hz, 100 watts complete all as specified and directed
S&F switch piano flush type 5/6 Amps single pole one way all as specified and directed
S&F switch piano flush type 15/16 Amps single pole one way all as specified and directed
M&L for socket out let 5 pin 5/6 Amps all as specified and directed
S&F in Socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed
S&F bell push, flush type 5 Amps white or ivory, ISI marked all as specified and directed
S&F in replacement call bell Ding Dong 230V, AC, single phase ISI marked all as specified and directed
S&F in ceiling rose 2/3 terminals 65x25 mm dia polycarbonate isolated all as specified and directed.
S&F in lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and directed
S&F in replacement of building security light fitting complete with 35 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out by GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed
M&L in replacement earthing complete with galvanised steel earth plate electrode size 600X600X6mm thick buried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4mm dia by means of bolts ,nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade ,wire mesh and lugs ,GI protection pipe of 15 mm bore light grade up to 7.5 mtr long ,etc complete all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately
S&F in replacement of DB, SPN 4-way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed
S&F in replacement of DB, SPN 8-way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed
S&F in replacement of DB, SPN 12-way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed
S&F in replacement of DB, TPN 4-way vertical type with single/three phase outgoing with provision for MCCB as incomer 415 volt with 200 amps rated bus bar complete all as specified and directed
S&F in replacement MCB 6-32 amps, 10 KA, SP 240 volt, 'C' series all as specified and directed
S&F in replacement MCB 32-40 amps, 10 KA, DP 240 volt, 'C' series all as specified and directed
All as per item No 44 hereinbefore but MCB DP 63 amps all as specified and directed
All as per item No 44 hereinbefore but MCB TPN 63 amps all as specified and directed
All as per item No 44 hereinbefore but MCB TPN 100 amps all as specified and directed
M&L in replacement of sub main wiring in PVC casing and capping of required size 4sqmm PVC insulated multi strand copper conductor FRLS with 01x4 Sqmm PVC insulated multi strand copper conductor as earth continuity wire complete all as specified and directed. Note:- Two runs of 4sqmm conductors and one run of 4 sqmm conductor with casing capping will be measured as one length.
M&L in replacement of sub main wiring in PVC casing and capping of required size 2x6 sqmm PVC insulated multi strand copper conductor with 01x6 sqmm PVC insulated multi strand copper conductor FRLS as earth continuity wire complete all as specified and directed. Note:- Two runs of 6 sqmm conductors and one run of 6sqmm conductor with casing capping will be measured as one length.
M&L in replacement of sub main wiring in PVC conduit of required size 2 x 4 sqmm PVC insulated multi strand copper conductor FRLS with 01x4 sqmm PVC insulated multi strand copper conductor as earth continuity wire complete all as specified and directed. Note:- Two runs of 4sqmm conductors and one run of 4 sqmm conductor with conduit will be measured as one length.
M&L in replacement of sub main wiring in PVC conduit of required size 2x6 sqmm PVC insulated multi stranded copper conductor with 01x6 Sqmm PVC insulated multi strand copper conductor as earth continuity wire complete all as specified and directed. Note:- Two runs of 6 sqmm conductors and one run of 6sqmm conductor with conduit will be measured as one length.
S&F 1100 Volts grade heavy duty cable PVC insulated aluminium conductor solid conductor, served with inner sheathing of PVC tape and overall PVC tape and overall PVC Sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire , 10 sqmm , twin core cable flat or circular complete all as specified and directed
S&F in replacement of switch socket combination (SSC) 15 Amp including PVC gang box fixing screw ISI marked all as specified and directed.
S&F in replacement of switch socket combination (SSC) 5 Amp including PVC gang box and fixing screw ISI marked all as specified and directed
M&L in replacement of 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked all as specified and directed
M&L in replacement of 2.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked all as specified and directed
M&L in replacement modular socket 6A/16A-2/3 pin combined 2 module complete as per site requirement 240Volts grade ISI Marked all as specified and directed
M&L in replacement modular socket 6A - 2/3 pin combined 2 module complete as per site requirement 240Volts grade ISI Marked all as specified and directed
M&L in replacement modular switch 1-way 16A, 1 module complete as per site requirement 240Volts grade ISI Marked all as specified and directed
M&L in replacement modular switch 1-way 6A, 1 module complete as per site requirement 240Volts grade ISI Marked all as specified and directed
S&F in replacement hold fastener nuts bolts made of S/S 2-inch long ISI Marked all as specified and directed
S&F PVC insulated multi strand copper conductor4.0 sqmm wire all as specified and directed
S&F PVC insulated multi strand copper conductor 6.0 sqmm wire all as specified and directed
S&F PVC insulated multi strand copper conductor 2.5 sqmm wire ,3 Core all as specified and directed
S&F in replacement of LED slim square panel light fitting for surface ceiling light, 12 watt, colour white/warm white , pressure die cast aluminium luminaire in powder coated white finish , independent electronic driver and including connected with 3 core 23/0.0076 insulated copper wire from celling rose to fitting connector complete all as specified and directed. Make : Havells cat part No EDGESURFACESQDLR12WLED840S or equivalent wipro/Philips/ Polycab
S&F in replacement of LED slim square panel light fitting, 36 Watt, 2x2 feet edge-lit luminaire suitable for arm strong/grid ceiling for low ceiling and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector complete all as specified and directed. Make: Havells cat part No STRATO2X2PLR36WLED840MOD or equivalent Philips/Goldmedal/Wipro/ Polycab
S&F in replacement of Decorative LED 15-watt new generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector complete all as specified and directed
S&F in replacement of LED slim circular panel light fitting for surface ceiling light of size dia 175mm height 35mm, 12-watt, colour white/warm white and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector complete all as specified and directed.
S&F in replacement of LED slim circular panel light fitting for grid ceiling down lighter of dimension dia 135mm , height 17.5mm , 10 watt, colour white/warm white and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector complete all as specified and directed
S&F in replacement of LED slim square panel down light fitting for grid ceiling light of size 135mmx135mm, height 17.5mm, 10 watt, colour white/warm white and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector complete all as specified and directed
S&F in replacement environmental friendly ultra modern, energy savings surface mounted decorative hexagonal bulk head back lit LED luminaire comprising of high brightness LEDs of capacity 10W complete all as specified and directed
S&F in replacement LED light fitting 10 watt, slim design, 230volts, indoor recess mounting down lighter circular type with reflector and detachable ballast tray, with lamp holder, connector block complete all as specified and directed
S&F in replacement LED light fitting four feet 20-watt, slim design, 230volts, Cool white/ warm white, indoor recess mounting with reflector and connector block complete all as specified and directed.
S&F in replacement invertor LED 4 ft batten 20 Watt, 6500K with square profile and polycarbonate channel, lithium ION battery with charging time 8 Hours -10 Hours and backup time upto 4 hours indoor recess mounting with reflector and connector block complete all as specified and directed
S&F in replacement switch piano flush type 5/6 Amps single pole one way all as specified and directed
S&F in replacement switch piano flush type 15/16 Amps single pole one way all as specified and directed
S&F in replacement socket out let 5 pin 5/6 Amps all as specified and directed
S&F in replacement socket outlet 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed
S&F in replacement bell push, flush type 5 Amps white or ivory, ISI marked all as specified and directed
S&F in repair Modular type stepped type electronic fan regulator 2 Module 230 Volts complete all as specified and directed
S&F in repair fan speed regulator, electronic step type, suitable for single phase AC, 240 volts, 50 Hz, 100 watts complete all as specified and directed
S&F in replacement of call bell Ding Dong 230V, AC, single phase ISI marked all as specified and directed
S&F in replacement plug top 15 Amp white or ivory, ISI marked all as specified and directed
S&F in replacement plug top 5 Amp white or ivory, ISI marked all as specified and directed
S&F PVC conduit 20 mm dia suitable for 1100 volt , 230/240V AC supply all as specified and as directed
S&F PVC conduit 25 mm dia suitable for 1100 volt , 230/240V AC supply all as specified and as directed
S&F in repair single pole and neutral sheet metal enclosure with a two pin and earth plug socket complete including one single pole MCB of 20 Amp, C Curve, 10 KA rupturing capacity complete all as specified and directed
S&F in repair three pole and neutral sheet metal enclosure with a two pin and earth plug socket, 4 modules complete including one single pole MCB of 32 Amp, C Curve, 10 KA rupturing capacity complete all as specified and directed
S&F in replacement onload change over switch 4P of capacity 63 Amp, 415V 50 Hz totally enclosed in SS enclosure complete all as specified and directed
S&F in replacement onload change over switch 4P of capacity 100 Amp, 415V 50 Hz totally enclosed in SS enclosure complete all as specified and directed
S&F in replacement MCCB 4 Pole 63 Amps, 16 KA, 415V, 50 HZ, ICS=100% ICU, with adjustable thermal settings, suitable for isolation complete all as specified and directed
S&F in replacement MCCB 4 Pole 100 Amps, 25 KA, 415V, 50 HZ, ICS=100% ICU, with adjustable thermal settings, suitable for isolation complete all as specified and directed
S&F in repair Inverted pyramid tripod type 10 W LED Bollard light with soft 360-degree light distribution, 220V, 50 Hz IP -65 rated corrosion free, 5700K complete all as specified and directed
S&F in repair LED Bollard Light with unique concept LED in IP 66 with sustainable performance in all section of Capacity 10W, 220V, 50 Hz CCT- 3000K, 800mm complete all as specified and directed
S&F decorative Post top light for 360 degree indirect light with IP 65 Protection , resistant to impact and corrosion , power coated aluminium die cast and spun aluminium body with clear /opal diffuser glare free and better uniformity , 40 Watt , 220 Volts , 50 Hz,5700K complete all as specified and directed
ARUNOTHAYA TRADERS (BID ID -3303303)
M/s. ARK BUILDERS (BID ID -3308249)
SREE VARU ELECTRICALS (BID ID -3303869)
chowdeshwariconstructionco (BID ID -3308854)
ANAND REFRIGERATION (BID ID -3302896)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .