Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.8 L+₹85,945 (6.66%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹18.8 L+₹5.9 L (45.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹18 L
EMD Value
₹54,000
Closing Date
27 Jun 2022, 11:00 amClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
REPAIR/ MAINTENANCE OF WINDOW TYPE/SPLIT TYPE AIR CONDITIONER AND DESERT COOLER AND VOLTAGE STABILIZER AT OTM ACCN SOUTH ZONE UNDER GE (AF) BAMRAULI
2022_MES_527437_1
8716/E8
Open Tender
Civil Works
Works
270 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹54,000
2 Aug 2022
30 May 2022
28 Jun 2022
30 May 2022
27 Jun 2022
13 Jun 2022
Amount
Overhauling & servicing of window /Split/tower/cassette type Air Conditioners up to 5.5 Ton capacity of any make and carry out of following tasks at different location of different establishment including taking down the AC (if required) from existing location, refixing / commissioning and testing the same after overhauling complete including the following :- (a) Inspection taking down, opening (dismantling) ,washing the condenser and cooling coil complete with acid/water as required and cleaning with air blower and testing complete (b) Checking / examine operation of condenser, blower motor, cooling coil and checking the air circulation to ensure complete movement of working part trouble free (c) Inspection of leakage in system and removal obstruction if any (d) Checking and correction earth continuity of electric items (e) Checking servicing thermostat and over load and other spares and test its functioning (f) Inspecting all electrical connection and remove if any defects (g) Checking servicing and greasing oiling of blower motor.(h) Top up Refrigerant gas if required. Note: Replacement of new parts/worn out parts in lieu of unserviceable/burn out part shall be measured and paid separately as supply only items of Schedule ‘A’.
Supply only the following spare parts for up to 5.5 ton capacity of Tower/cassate/window/ Split type AC any make & any model.
(i) Air Filter Make and model-as per existing
(ii) Starting relay Make-Totaline/Epcos/CLASSIC/Whirlpool
(iii) Starting capacitor 120-150 mfd Make- Totaline / Epcos / DVM/Whirlpool
(iv) Starting capacitor 100-120 mfd. Make- Totaline / Epcos //DVM/Whirlpool
(v) Running capacitor 40-60 mfd. Make- Totaline/ Epcos/ DVM/Whirlpool
(vi) Running capacitor 30-36 mfd. Make- Totaline / Epcos /DVM/Whirlpool
(vii) Running capacitor 4-6 mfd. Make- Totaline/ Epcos/Whirlpool
(viii) Thermostate switch Make as per existing
(ix) Propeller fan suitable for window/split type AC Make- As per existing
(x) Cooling Coil Make- as per existing
(xi) Condensor coil Make- as per existing
(xii) Outer cover duly painted for Window/split AC
(xiii) MCB SP 20-32 Amps ‘C’ Series ,10KA, 240 volts SP Make : Havells/HPL/Legrand
(xiv) Three pin metalic socket outlet suitable for sheet metal enclosure Make : Havells/HPL/Legrand
(xv) Three pin metallic plug top suitable for sheet metal enclsoure Make : Havells/HPL/Legrand
(xvi) PVC flexible insulated cable multi-strand copper conductor 3/4 core of size 2.5 sq mm Make- Kalinga / Plaza / Gloster/Polycab
(xvii) Front grill for split/window AC Make as per existing
(xviii) Wiring kit with thimbles
(xix) Power Contactors 240 volts AC 50HZ 16-25 Amps range.
(xx) Power contactor 415V AC, 50 Hz 20-32 Amps range
(xxi) Isolator 4 pole 63 Amps 415 Volt
(xxii) Overload protector suitable for compressor as per existing.
(xxiii) Blower for indoor unit/window AC as per existing.
S & F in replacement of Sheet metal enclosure in/on wall with socket plug top and MCB single pole neutral enclosure with 2 pin + earth plug and socket complete with one single pole MCB of 32 amps 230 volts of rupturing capacity of 10 KA and making good the disturbed surface with existing colour matching complete all as specified and directed. Make:-Legrand/ L&T/Schneider/Siemens/Hager/HPL
Removing the burnt/defective sealed compressor unit of any type and any make from Air Conditioner window type up to 2.0 ton capacity by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with filling of refrigerant gas (in quoted rate), welding/brazing work and tightening foundation nuts & bolts including etc all as specified and directed. Note :- (i) The unit rate quoted is inclusive of capillary, drier, copper tubing (ii) New compressors shall be purchased from authorised dealer only and the same shall be produced in sealed along with necessary original paid voucher
All as per Sll Item No. 4 above but for 1.5 ton Split Air conditioner.
All as per Sll Item No. 4 above but for air conditioner split type 2.0 ton capacity.
All as per Sl Item No. 4 above but for 3.0/4.0 ton capacity Split type Air conditioner.
M&L for replacement of damaged copper tubing of dia 5/8 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
M&L for replacement of damaged copper tubing of dia 3/8 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
M&L for replacement of damaged copper tubing of dia 1/2 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
M&L for replacement of damaged copper tubing of dia 1/4 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
M&L for replacement of damaged insulation with heavy duty foam for copper tubing of split air conditioners complete all as directed
S&F in replacement of PVC drain pipes of size 15 mm from indoor unit to exist point as per design including accessories clmps fastners complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of medium class insulated Hard PVC Drain Water pipe of 20 mm dia with all fittings ie elbow,tee,bend etc all as specified and directed.
Repair to Air conditioner Window/Split type upto 2.0 ton to capacity by testing the leakage in system by filling of Nitrogen gas upto suitable pressure and repairing of leakage with brazing work, cleaning and flushing out the complete system, replacing of drier/filter if required, making the complete system leak proof, vacuuming the system and charging Refrigernt gas (M410a/R134a/R-22) as existing and testing etc complete all as specified & directed. Note :(a) Drier/filter, capillary and copper tubing are inclusive in unit rate.(b) Contractor should be responsible if leakage of refrigerent gas after repair on completing job and done same job without extra payment.
Repair to Air conditioner Split type 3.0 ton to 5.5 ton capacity by testing the leakage in system by filling of Nitrogen gas upto suitable pressure and repairing of leakage with brazing work, cleaning and flushing out the complete system, replacing of drier/filter if required, making the complete system leak proof, vacuuming the system and charging Refrigernt gas (M410a/R32/R-22) as existing and testing etc complete all as specified & directed. Note :(a) Drier/filter, capillary and copper tubing are inclusive in unit rate.
Supply and replacement blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type upto 2.0 ton capacity as per existing model complete all as directed and specified.;
Supply and replacement blower Motor 0.2/0.25 HP for Air conditioner split type of capacity 1.5 ton/2.0 ton/3.0 ton/4.0 ton as per existing model complete as directed and specified.
Repair and fixing blower Motor of split type /window type Air Conditioners of any make and any capacity for making air conditioner serviciable complete all as directed and specified.
Supply and replacement Condensor Motor (outdoor motor) for split type Air conditioner as per existing model and any capacity complete as directed and specified.
Repair and fixing Condensor Motor (outdoor motor) for split type Air conditioner as per existing model of any make and any capacity for making air conditioner serviciable complete all as directed and specified.
Repair and fixing Printed Circuit Board of split type /window type Air Conditioners of any make and any capacity for making air conditioner serviciable complete all as directed and specified.
Supply and replacement Printed Circuit Board as per existing model to repair to split type/window type Air Conditioners of any make and type of any capacity any complete all as directed Make- Voltas/Carrier/toshiba.
Supply and replacement Inverter Type Printed Circuit Board(for indoor and outdoor unit complete) of any make and type of air conditioner split inverter type of any make and type (variable speed compressor) as per existing model and capacity up to 2.0 ton complete all as specified and directed. Make:Carrier (X power gold)/Electrolux/LG/HITACHI
Repair and fixing Inverter Type Printed Circuit Board of split type Air Conditioners (with variable speed compressor) of any make and any capacity for making air conditioner serviciable complete all as directed and specified.
Supply and replacement for wireless remote control unit for split/window type airconditioner as per existing model complete all as directed. Make Carrier (Duracool)/Carrier (X power gold)/LG/VOLTAS
M&L for opening of the automatic voltage stabilizer capacity up to 8 KVA for repair detection of fault and its repair cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified . Note : (a) Replacement of new parts/worn out parts in lieu of unserviceable/burn out part shall be measured and paid separately as supply only and minor spare are including in quoted rate.
Supply only the spare parts suitable for automatic voltage stabilizer of any make and capacity.
(a) Volt meter (0-300 volts)
(b) Control relay
(c) IC controlled circuit for 5KVA
(d) IC controlled circuit for 8 KVA
(e) Control transformer
(f) Low/high voltage cut off and TDR system
(g) Main transformer for 5 KVA
(h) Main transformer for 8 KVA
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA Note: Old stablizer shall be deposited in the MES store yard.
M&L for Shifting and refixing of split type AC (Indoor and Outdoor units) of any make and any type after servicing and charging of gas (M410a/R134a/R-22/r32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc complete all as specified and directed. Note :(i) The unit rate quoted is deemed to be inclusive of dismantling and refixing of split AC (ii) The unit rate quoted is deemed to be inclusive of provision of drier capillary, copper tubing, refrigerant gas, insulation and LDPE pipe as required (iii) The unit rate quoted is deemed to be inclusive of making hole and filling the hole on wall with PCC (1:2:4) type BO (Using 12.5mm graded stone aggregate) 15mm thick rendering in cement mortar 1:3 and making good the disturbed surfaces with existing colour matching.
M&L for Shifting and refixing of window AC of any make and any type after servicing and charging of gas (M410a/R134a/R-22/R32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc complete all as specified and directed. Note :(i) The unit rate quoted is deemed to be inclusive of dismantling and refixing of split AC (ii) The unit rate quoted is deemed to be inclusive of provision of drier capillary, copper tubing, refrigerant gas, insulation and LDPE pipe as required (iii) The unit rate quoted is deemed to be inclusive of making hole and filling the hole on wall with PCC (1:2:4) type BO (Using 12.5mm graded stone aggregate) 15mm thick rendering in cement mortar 1:3 and making good the disturbed surfaces with existing colour matching.
M&L for attending day to day complaints and rectifying faults like decarbonizing connections in the AC Box, , any burning due to over loading in AC and restoring connection of AC with wire or thimbles,attending and rectifying faults related to AC like drain water leakage ,filter cleanig,remote setting etc and related to stabilizers (5 to 8 KVA) incl Sunday & Holidays complete all as directed by Engineer-in-Cgarge. Note : (i) All T&P required shall be provided by contractor including ladders of any size as per requirement at site. (iii) Minor items like machine screw, plastic clamps, insulation tape, nails, flexible pipe, thimbles, lugs for contactor, etc shall deemed to be included in the unit rate. (iv) The major items replaced during repairs shall be measured and paid under respective items of Sch 'A'.
M&L for removing defective window AC and replacing the same for window AC of capacity upto 2.0 ton .
M&L for removing defective outdoor unit and replacing the same for split air conditioner of capacity 1.5/2 Ton with remote complete all as specified and directed.
M&L for removing defective indoor unit and replacing the same for split air conditioner of capacity 1.5/2 Ton with remote complete all as specified and directed.
M&L for outdoor unit stand for wall mounting type or floor mounted complete factory made as recommended for make Airconditioner and approved by Engr-in-charge.
Taking down/out desert cooler of any make and capacity from various locations and M & L for complete cleaning washing and descaling scraping down and removing existing paint, preparation of surface and painting the entire/complete body of desert cooler, inside and outside, by sprayer with two coats of approved synthetic enamel paint and writing SM/ MES no. with black synthetic enamel paint by complete all as specified & directed EIC.
S&F water lifting pump submersible type upto 5 feet head operating on SP 230 Volts, 50 HZ AC after and including taking out existing defective pump of any description of Desert Coolers, complete all as specified & as directed.(Make : Khaitan / Crompton/ Vansal)
S&F in replacement of read made wood wool pad size as required at site of 15 mm thickness, made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified and directed.
S&F Desert cooler fan motor operating on SP 230 Volts, 50 HZ, AC 1/7HP 1400 rpm with fan blade (exhaust type) and mounting Kit complete after and including taking out existing fan motor all as directed. Make : Khaitan/Crompton/Vansal
S&F of PVC sheathed and PVC insulated 3 core cable, 1.5 Sqmm copper conductor of Make: National / Gloster / Paragon/ Havells / Kalinga complete all as specified and directed.
M&L for replacement of PVC pipe 10 mm bore standard quality of desert cooler complete with fixing arrangement, all as specified and directed.
S & F Clamp for kit fan motor as per site requirement with nut, bolt & washers complete.
S & F Piano type switch 5 Amps of Make: Anchor / Cona / Kay.
S & F PVC water distributor, (Set of four way and two way).
S & F plug top 5amp 3 pin type Make:- Anchor/Standerd/Kay
S&F Polycarbonate duly spray painted kit fan blade 300mm/380mm sweep complete all as directed
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
M/s Hanspal Enterprises
ANSARI REFRIGERATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .