Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.7 LAccepted-AOC | L-1 | Accepted-AOC Lowest and reasonable | |
| 2 | L-2₹17.8 L+₹3.6 L (25.2%)Rejected-Finance | L-2 | Rejected-Finance Not Lowest | |
| 3 | L-3₹18.9 L+₹4.6 L (32.4%)Rejected-Finance | L-3 | Rejected-Finance Not Lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
6 Nov 2019, 6:00 pmClosed
GE 861 EWS
GE 861 EWS C/o 56 APO
REPAIR / MAINTENANCE OF EXTERNAL WATER SUPPLY DISTRIBUTION SYSTEM AT KHREW AND SHER-E-SHALI UNDER GE 861 EWS
2019_MES_268111_2
GE 861 EWS-29/2019-20
Open Tender
Civil Works
Item Rate
180 days
Under GE 861 EWS
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹30,000
Yes
29 Jan 2020
9 Oct 2019
8 Nov 2019
16 Oct 2019
6 Nov 2019
23 Oct 2019
Amount
Excavation in trenches n.exe 1.5m wide and n.exe 1.5m deep for laying pipe line incl getting out in any type of soil complete all as specified and directed.
Returning filling in incl spreading watering and well ramming in layers in hard/dense soil each not exceeding 25cm thick complete all as specified.
Removing surplus soil to a distance not exe 50 mtr and depositing where directed at a level not exe 1.5 m above the starting point complete all as specified and directed.
Dismantling/taking out to old rusted/blocked /corroded, unsv GI/CI pipe line from trenches and from wall/floor etc with complete fittings of following sizes. (a) CI /GI tubing 150 mm dia bore
(b) CI /GI tubing 100mm dia bore
(c) CI /GI tubing 80mm dia bore
(d) GI tubing 50mm dia bore
(e) GI tubing 40mm dia bore
(f) GI tubing 25mm dia bore
(g) GI tubing 20mm dia bore
S&F GI water tubing medium grade (ISI marked) laid in trenches incl fittings as required as site and including jointing internal as specified of following size :- Make :-Jindal/Swastik/Prakash (a) GI tubing 150 mm dia bore
(b) GI tubing 100mm dia bore
(c) GI tubing 80mm dia bore
(d) GI tubing 50mm dia bore
(e) GI tubing 40mm dia bore
(f) GI tubing 25mm dia bore
(g) GI tubing 20mm dia bore
S & F CI pipe Cast iron pipes with spigot and socket ends centrifugally cast. Class A, in any length, laid in trenches following sizes : (a) 150 mm
Re-fixing and laying only of old steel water tubing retreived under sr item No. 05 to 10 above and returning of old screw threads as required in trench ,in new or old positions including descaling cleaning for fixing of fittings such as elbow sockets, union, reducer all required as directed by Engineer-in charge for the following sizes:- (a) GI tubing 150 mm dia bore
(b) GI tubing 100 mm dia bore
(c) GI tubing 80mm dia bore
(d) GI tubing 50mm dia bore
(e) GI tubing 40mm dia bore
(f) GI tubing 25mm dia bore
(g) GI tubing 20mm dia bore
S&F in repair Gun metal globe or gate valve non rising spindle heavy duty with iron wheel head, screwed both end for connection GI pipes complete all as specified for the following sizes of pipe (ISI marked) Make : Kirloskar/Bir/Varun/ Venus/Leader/Sant (a) GI tubing 50mm dia bore
(b) GI tubing 40mm dia bore
(c) GI tubing 25mm dia bore
(d) GI tubing 20mm dia bore
(e) GI tubing 15mm dia bore
M & L replacement of CI fitting such as bends, tappers any type tee, caps reducer ,collar and plug all as directed by Engr-in-Charge .
M & L replacement of Bib taps all as specified and directed, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of following sizes : (a) 15 mm
Material and labour for cutting of existing CI water main line in position in trenches of size 150 mm dia for insertion of tee for taking branch connection including excavtion earth work re-filling etc all as specified and directed . Note:- CI specials, joints and jointing material shall be measured and paid for separately.
M&L lagging to pipes used in external water supply of plumbing all around with 25mm thick bonded mineral wool pre-formed. SNAPON pipe section of density 144 Kg/Cum conforming to IS-9842 or equivalent and provided chicken wire mesh netting 25gauge 20mm meshing and plaster of Peris 3 to 5 mm thick all around the mesh after breaking old unsv/ broken lagging all as specefied and directed by Engineer in charge for the following pipe lines :- (a) GI tubing 50mm bore
(b) GI tubing 40mm bore
(c) GI tubing 25mm bore
(d) GI tubing 20mm bore
(e) GI tubing 15mm bore
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc all as speecified and directed
Brick work with sub class B old size bricks straight/curved on plan exc 6m mean radius built in cement mortar 1:4 concrete all as specified and directed by EIC.
Rendering 15 mm thick on fair faces of brick work/concrete surfaces in cement mortar 1:4 finished fair and even all as specified and directed by EIC.
PCC 1:2:4 type B1 using 20mm graded stone aggregate as in pillars, columns including caps and bases with necessary from work complete all as specified and directed by EIC.
M&L replacement of water pressure gauge of Bourden’s type 150mm dia with pressure range of 0 to 10 Kg/Sqcm on rising main water supply line including fixing arrangement , GI tubing nipple stop cock making holes by drilling and welding of socket complete all as specified.
M&L opening of GI pipe , cutting threading & S&F GI socket union and reducing , Tee, 40x15mm for branch connection including excavation and other related work all as directed.
Description all as per item No-47 above but size 25x15mm
Supply only Calcium based granular disinfectant for water treatment more stable than chlorine gas, and stronger than Bleaching powder and sodium Hypochloride pack of 45 Kg, Plastic drum
S&F in repair cast iron non return valve of size 150mm with flanged ends having by pass arrangement ( PN 1.6) complete all as directed by Engr-in-charge.
S& F in repair brass heavy duty foot valve of size 150 mm complete all as directed by Engr-in-charge.
S& F in repair brass heavy duty foot valve of size 100 mm complete all as directed by Engr-in-charge.
S& F in repair gland packing 12mm dia complete all as directed by Engr-in-charge.
S& F in repair gland packing 6 mm dia complete all as directed by Engr-in-charge.
M&L for scraping removing and cleaning of interior surface of under ground reservoir of capacity 25000 Gallons at 6 mtr under the ground level cleaning with Alum water with brush after removing the mud /silt in side the tank to the satisfaction of Engr-in- charge including white washing to inner surface to tank and writing date of cleaning and capacity to tank with synthetic enamel paint of size 10cm height on tank complete and all as specified.
All as per srl item No. 55 above but capacity 50000 Gallons reservoir complete all as specified and directed.
Supply ,fixing ,connecting and testing sluice valve Cl body brass spindle, iron wheel head type PN 1.6(ISI marked) complete all as specified of the following sizes:- Make: kirlosker/Bir/Varun/Vinus/Leader/Sent (a) Sluice 150 mm dia bore
(b) Sluice 100mm dia bore
(c) Sluice 80 mm dia bore
Supply and fixing in replacement of maintenance free battery 12 volt 180 AH type including battery leads and initial charging of battery. Old unsv battery will be deposit to MES Store yard Make :Exide/Amron.
Supply and fixing in replacement of maintenance free battery 12 volt 100 AH type including battery leads and initial charging of battery. Old unsv battery will be deposit to MES Store yard, Make :Exide/Amron.
Dismantling the electric motor induction motor assembly of pump set/VT of capacity 30 HP to 100 HP from the foundation after disconnecting the electric connection,carrying the same to workshop,dismantling of electric motor and taking down worn out windings of rotor field coils and excitor coils,rewinding the startor,rotor and excitor gauge,replacement of insulation material,heat varnishing provision of connecting leads and terminal plates etc to make the electric motor fully serviceable,reassembling the motor shifting back to the installation ,assembling the same with engine making electric connections,testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Dismantling the complete pump set of cap 75 to 100 HP from foundation channel after disconnecting all inlet and outlet connections ,carrying the same to workshop,dismantling of pump , cleaning throughly and taking down worn out parts such as Ball bearing,Impeller , rubber coupling, bushes ,brass ring , studs , replacement of the same with new ,lath work of pump shaft , impeller if required , reassembling , commissioning and testing after fix on orignal site for smooth functioning up to the entire satisfaction complete all as specified and directed by Engineer-in-Charge.
FASD starter oil immersed of capacity 100 HP built in over load relay, incl taking down the existing unserviceable starter complete all as specified by Engr-in-charge. Make: Kilburn/ABB/Bharat Cutler Hammer/Bentex
Taking up and down water lubricated deep well vertical turbine pump set of cap 75 HP any make including rachet assay, hollow shaft, motor, discharge head body, column pipe, steel shaft, including spider with bush etc complete all as specified and directed by Engineer-in-charge.
Supply and installation of Submersible pump, electric driven 415 V, TP suitable for 250 mm dia bore well ( Casing pipe of size 300/350 mm),15 HP (11KW), out put min 60 LPM @ head 370 mtr. Model 60 HH 1524 including automatic star delta starter for submersible pump, sheet metal enclosure of suitable capacity as directed including analog amp meter,volt meter, indicator ,having suitable for capacity 15 HP including 80 RM flexible flat PVC sheathed stranderd copper conductor of size 10 Sqmm three core, complete all as specified and directed. Make: Kirlosker or equivaent in KSB/JYOTI
Supply and fixing in repair Gun metal bush of any size /make suitable for suction/discharge /intermediate bowl complete and all as specified.
Supply and fixing in repair ball bearing as per existing size for VT motor 60/75 HP Make SKF/NBC/NSK
Repair/Replacement and AMC for 06 months of RO + UF commercial plant capacity of 250 LPH including Replacement of sediment filter 20 " (Every Month )- 2 Nos , Replacement of chemical for vessels (Once in a 06 months )- 2 Nos , Replacement of RO membrane (Once in a 06 months )-1 Nos , Service will be done every two months or on call, AMC including all Electrical Parts , including warranty/Guarantee of electronic/electrical items such as Motor 1/2 Hp - 1 No, Dozing Pump 1 No, Pressure gauge, UV Lamp, Electronic panel board and rectifying if any leakage/breakage/short-Circuit of vessel, multiport and panel board, panel wires, other spares , Testing complete all as directed for entire satisfaction of the Engr-in charge.
M/L for flat 3 core copper conductor PVC insulated and PVC sheathed submersible cable of nominal area of conductor 16 sq mm make Havells/HPL/Finolex.
S&F 1100 volt grade heavy duty XLPE cable with PVC insulated copper conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 20 Sqmm nominal cross section 2 core laid in trenches,fixed to pole or passing through pipes including all necessary clamps,nuts, bolts washers complete all as specified and directed.
S&F 1100 volt grade heavy duty XLPE cable with PVC insulated copper conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 35 Sqmm nominal cross section 2 core laid in trenches,fixed to pole or passing through pipes including all necessary clamps,nuts, bolts washers complete all as specified and directed.
Supply and fixing in repair aluminium thimbles 1100 Volts suitable for 70 sqmm to 150 sqmm cable , complete and all as specified.
Supply and fixing in repair aluminium thimbles 1100 Volts suitable for 25 sqmm to 50 sqmm cable , complete and all as specified.
Supply and fixing in repair aluminium thimbles 1100 Volts suitable for 6 sqmm to 16 sqmm cable , complete and all as specified.
Supply and fixing in repair finished hilghly durable ruggedness copper thimbles 1100 Volts suitable for 70 sqmm to 150 sqmm cable , complete and all as specified.
Supply and fixing in repair finished hilghly durable ruggedness copper thimbles 1100 Volts suitable for 25 sqmm to 50 sqmm cable , complete and all as specified.
Supply only waterproof insulation tape for cable and wire 220V, double layer made of rubber and mastic to seal moisture and wire connection of size 35mm width. Make : Kinjal/Anchor/Steelgrip
Taking out submersible pump set up to 55 HP of any make from the bore well complete with column pipe and other connected part and lowering the same after repair/replacement of the defective parts such as pump shaft , impeller, bushes, neck ring bowl of pump , shaft coupling, studs as per site requirment complete all as specified and directed by Engr-in-Charge. Note : Cost of all spare parts shall deem to have been included in quoted rates.
M & L run lead joint for water supply CI pipe of size 80mm, complete and all as specified.
M & L run lead joint for water supply CI pipe of size 100mm, complete and all as specified.
M/S Hilal Builders
M/S MOHAMMAD SHABAN AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .