Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L1 | Accepted-AOC ACCEPTED. BEING THE L1 BIDDER. | |
| 2 | L2₹38.9 L+₹6.3 L (19.4%)Rejected-AOC NIRMAL NIKETAN OLD GANGAPUR NAKA GANGPUR ROAD SHREENAGAR NASHIK 422013 | NASHIK | MAHARASHTRA | 422013 | L2 | Rejected-AOC REJECTED AS NOT BEING THE LOWEST BIDDER. | |
| 3 | L3₹39.0 L+₹6.4 L (19.7%)Rejected-AOC | L3 | Rejected-AOC REJECTED AS NOT BEING THE LOWEST BIDDER. | |
| 4 | L4₹40.7 L+₹8.1 L (24.8%)Rejected-AOC PULWAMA JAMMU KASHMIR 192301 INDIA | PULWAMA | JAMMU AND KASHMIR | 192301 | L4 | Rejected-AOC REJECTED AS NOT BEING THE LOWEST BIDDER. | |
| 5 | L5₹42.8 L+₹10.1 L (31.1%)Rejected-AOC GANESH MURTI NAGAR PART 3RD ROOM NO 103 CAPT PRAKASH PETHE MARG CUFF PARADE MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-AOC REJECTED AS NOT BEING THE LOWEST BIDDER. |
| Sl No | Description | Qty | Unit | Vishal Builders L1 | GOPAL ENTERPRISES L3 | NIKAASH INFRACON L2 | Peerzada And Sons L4 | POOJARANI ELE-TECH L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out In Hard/dense soil. complete all as specified and directed by Engineer In Charge. | 250 | Sqm | 50 ₹12,500 Lowest | 800 ₹2,00,000 | 800 ₹2,00,000 | 200 ₹50,000 | 60 ₹15,000 |
| 2.00 | Excavating in trenches, by mechanical means(hydraulic excavator) n exc 1.5 m wide and n exc 1.5 m in depth; for footing, Plinth Beam & Dwarf Wall, etc. n exc 10 sq m on plan and getting out in Hard/dense soil. complete all as specified and directed by Engineer In Charge. | 30 | Cum | 450 ₹13,500 Lowest | 800 ₹24,000 | 800 ₹24,000 | 500 ₹15,000 | 600 ₹18,000 |
| 3.00 | All as per item No 2 above, but depth exc 1.5 m and n exec 3.0 m. complete all as specified and directed by Engineer In Charge. | 12 | Cum | 750 ₹9,000 | 800 ₹9,600 | 800 ₹9,600 | 380 ₹4,560 Lowest | 600 ₹7,200 |
| 4.00 | M & L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engineer In Charge. | 65 | Sqm | 70 ₹4,550 | 150 ₹9,750 | 150 ₹9,750 | 30 ₹1,950 Lowest | 80 ₹5,200 |
| 5.00 | M & L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed by Engineer In Charge. | 28 | Sqm | 100 ₹2,800 | 150 ₹4,200 | 150 ₹4,200 | 80 ₹2,240 | 70 ₹1,960 Lowest |
| 6.00 | M & L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by Engineer In Charge. | 30 | Rm | 50 ₹1,500 Lowest | 100 ₹3,000 | 100 ₹3,000 | 100 ₹3,000 | 70 ₹2,100 |
| 7.00 | M & L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer In Charge. | 25 | Sqm | 70 ₹1,750 Lowest | 100 ₹2,500 | 100 ₹2,500 | 150 ₹3,750 | 80 ₹2,000 |
| 8.00 | M & L Cement concrete in foundations, filling and mass concrete 1:4:8 using 40 mm graded aggregate (For Foundation) complete all as specified and directed by Engineer In Charge. | 6 | Cum | 4,000 ₹24,000 | 500 ₹3,000 Lowest | 500 ₹3,000 Lowest | 4,000 ₹24,000 | 5,000 ₹30,000 |
| 9.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Hard/dense soil. complete all as specified and directed by Engineer In Charge. | 20 | Cum | 50 ₹1,000 Lowest | 500 ₹10,000 | 500 ₹10,000 | 250 ₹5,000 | 120 ₹2,400 |
| 10.00 | Removing excavated material in Hard/dense Soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer In Charge. | 59.5 | Cum | 300 ₹17,850 Lowest | 600 ₹35,700 | 600 ₹35,700 | 500 ₹29,750 | 650 ₹38,675 |
Tender Value
₹41.8 L
EMD Value
₹80,000
Closing Date
5 Dec 2025, 6:00 pmClosed
GE (NW) BHANDUP
GE (NW) BHANDUP, MUMBAI
PROVISION OF INTEGRATED WATCH TOWER WITH REST ROOM AT INS HAMLA UNDER GE (NW) BHANDUP
2025_MES_739955_1
8451/B
Open Tender
Civil Works
Item Rate
180 days
INS HAMLA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NW) BHANDUP
₹80,000
Yes
20 Jun 2026
14 Nov 2025
6 Dec 2025
14 Nov 2025
5 Dec 2025
28 Nov 2025
14 Nov 2025 - 24 Nov 2025
M & L Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out In Hard/dense soil. complete all as specified and directed by Engineer In Charge.
Excavating in trenches, by mechanical means(hydraulic excavator) n exc 1.5 m wide and n exc 1.5 m in depth; for footing, Plinth Beam & Dwarf Wall, etc. n exc 10 sq m on plan and getting out in Hard/dense soil. complete all as specified and directed by Engineer In Charge.
Material and labour for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to Galvanised earth steel wire 4.0 mm dia by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion all as specified and directed.
M & L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engineer In Charge.
M & L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed by Engineer In Charge.
M & L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by Engineer In Charge.
M & L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer In Charge.
M & L Cement concrete in foundations, filling and mass concrete 1:4:8 using 40 mm graded aggregate (For Foundation) complete all as specified and directed by Engineer In Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Hard/dense soil. complete all as specified and directed by Engineer In Charge.
Removing excavated material in Hard/dense Soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer In Charge.
M & L RCC- M-30 (Design Mix) using 20mm graded aggregate For Footing and plinth beams complete all as specified and directed by Engineer In Charge.
M & L RCC- M30 (Design Mix) using 20mm graded aggregate for Column complete all as specified and directed complete all as specified and directed by Engineer In Charge.
M & L RCC- M30 (Design Mix) using 20mm graded aggregate for beams and lintels complete all as specified and directed complete all as specified and directed by Engineer In Charge.
M & L RCC- M30 (Design Mix) using 20mm graded aggregate for RCC Slab complete all as specified and directed by Engineer In Charge.
M & L RCC- M30 (Design Mix) using 20mm graded aggregate for RCC parapet wall/drops/RCC Chajjas complete all as specified and directed by Engineer In Charge.
M & L Reinforced Cement Concrete M-30 (Design Mix) using 20mm graded aggregate for Staircase Excluding Landing. complete all as specified and directed by Engineer In Charge.
S & F TMT bars 10mm dia & over of Grade Fe 500 incl cutting, bending, binding & placing in position with binding wirefor footings Slab beams roof slab etccomplete all as specified and directed by Engineer In Charge.
All as per item No 17 but 5 to 10mm dia in stirrups, spacers & binders. complete all as specified and directed by Engineer In Charge.
M & L Form work for rough finished surfaces of concrete measured flat for For Footing complete all as specified and directed by Engineer In Charge.
M & L Form work for rough finished surfaces of concrete measured flat for Column, complete all as specified and directed by Engineer In Charge.
M & L use & waste Form work for rough finished surfaces of concrete measured flat for Plinth Beam complete all as specified and directed by Engineer In Charge.
M & L use & waste Form work for rough finished surfaces of concrete measured flat for RCC beams sides and soffits complete all as specified and directed by Engineer In Charge.
M & L use & waste Form work for rough finished surfaces of concrete measured flat for RCC Slab complete all as specified and directed by Engineer In Charge.
M & L use & waste Form work for rough finished surfaces of concrete measured flat for RCC drops/Chajjas complete all as specified and directed by Engineer In Charge.
M & L Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing) complete all as specified and directed by Engineer In Charge.
M & L Pre-cast cement concrete block masonry with solid blocks Type C1 1:3:6, exc. 10 cm in width and setting in Cement mortar (1:6) mortar, complete all as specified and directed by Engineer In Charge.
M&L 5 mm thick ready mix plaster over concrete surfaces of ceiling surfaces; surfaces finished even and smooth including necessary scaffolding complete all as specified and directed by Engineer In Charge..
M&L 10 mm thick ready mix plaster , on fair faces of brick work or concrete surfaces andsurfaces finished even and smooth including necessary scaffolding complete all as specified and directed by Engineer In Charge.
M & L For 3mm thick wall care putty on wall complete all as specified and directed by Engineer In Charge.
SUPPLY ONLY WPC complete all as specified and directed by Engineer In Charge.
M&L preparation of new plaster wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed by Engineer In Charge.
M & L For Three coats of white wash on ceiling complete all as specified and directed by Engineer In Charge.
M&L for preparation of NEW plastered walls surfaces for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and directed by Engineer In Charge.
M & L For Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer In Charge.
M &L PCC 1:3:6 type C2 75mm thick as in plinth protection finished even and smooth using extra cement compete all as specified. complete all as specified and directed by Engineer In Charge.
M & L for 10+5 mm thickready mix plaster using WPC @ 2% by weight of cement on brick work or concrete surfaces; surfaces finished even and smooth including necessary scaffolding complete all as specified Note : Water proofing compound shall be measured & paid seperately. complete all as specified and directed by Engineer In Charge.
Supply,Install,Testing and Comissioning of tripod mounted hi-intensity multi functional,manually operated, unidirectional, 300watt LED search light, focus range min. 700mtr, LED efficiency >140 lm/w, CCT 5500K, LM6 housing, front dia >440mm, operating voltage: 90V- 300V, 50hz, PF >0.95, THD <20%, CCT: 5500K, CRI >70, Optics used- PMMA/PC lens, narrow beam 7 degree, average lux level at 10meter >9000 (min.) with circle of approx 1meter, toughened glass with silicon gasket, over volt / under volt & short circuit protected, confirming to LM79, LM80, IK07, IP66, lux level test report, Type tested- IS:10322.5.5 and B.I.S. certified. This search light would be installed on a movable tripod stand (1mtr long) of iron made having lockable PVC castor wheel (2+2) at bottom and would be designed so that the search light would enable to rotate easily 360° in horizontal plane & vertical movement > 45°, bulit-in locking knob, all the hardware are in S.S. & metal parts would be Zinc powder-coated for outdoor installations. Make: Kalin. Cat No.: TRI-LRFLL-25PC30, or any make having equivalent specifications of ISI Approved
M&L machine cut kota stone slab flooring 20 - 25mm thick over 20mm cement screed in CM 1:6 laid and jointed with gray cement slurry mixed with pigment to match the shad of the slab including mirror polishing complete all as specified and directed by Engineer In Charge.
M&L Non skid ceramic colored tiles, edge cut 7 to 8mm thick square or rectangular) area of Each tile exceeding 0.11 sqm but not exceeding 0.18mm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile incl 15 mm thick screed bed in cement mortar 1:4 including finishing even and fair complete all as specified and directed by Engineer In Charge.
item No 117 but for Sub Main wiring Three Run 4.0 sqmm. Complete all as specified and directed.
M&L Coloured glazed ceramic tiles of size 350x 450 x 7mm thick,on vertical wall surface, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces inc rendering cement plaster, 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces to receive tiles complete all as specified and directed by Engineer In Charge.
Supply & fixing ceiling rose, surface bakelite 3 terminal complete all as specified and directed by Engineer In Charge.
S&F 60 mm M-35 grade machine pressed precast concrete interlocking paver blocks with white cement and color pigment, any shape and size conforming to IS 15658:2006 complete all as specified and directed.
All as above item No 124 herein after but for the pipe dia 20mm
All as per item No 2 above, but depth exc 1.5 m and n exec 3.0 m. complete all as specified and directed by Engineer In Charge.
M&L for 15 to 20mm machine cut kota stone slab as in riser of steps, skirting, dado and pillar, cills and jambs laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with beewax polishand including over 15mm thick screed bed or bedding layer in CM1:4 complete all as specified and directed by Engineer In Charge.
S&F Factory made solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, in opening as specified and directed. complete all as specified and directed by Engineer In Charge.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site complete all as specified and directed by Engineer In Charge.
S & F For powder coating Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer In Charge.
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed by Engineer In Charge.
S & F aluminium grill conforming to DG- 102 of Deco Grill or equivalent , (10mm X 5.2mm) thick of approved design or equivalent as approved by Accepting Officer and fixing with and including 'F/U' channel not less than 1.5mm thick complete all as specified and directed by Engineer In Charge.
S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of exturded sections or cast aluminium alloy all as specified and directed. complete all as specified and directed by Engineer In Charge.
S&F 150 mm long aluminium bow handles cast type anodised. complete all as specified and directed by Engineer In Charge.
S&F 200 mm long aluminium anodised barrel tower bolt of extruded section. complete all as specified and directed by Engineer In Charge.
S&F butt hinges med weight cold rolled MS, size 100 mm. complete all as specified and directed by Engineer In Charge.
M&L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’. complete all as specified and directed by Engineer In Charge.
M&L for preparation of new wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer In Charge.
S & F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets 10 ltr complete all as specified and directed by Engineer In Charge.
S & F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed by Engineer In Charge.
S & F 110mm PVC (SWR) WC connector bent type complete all as specified and directed by Engineer In Charge.
S & F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed by Engineer In Charge.
S & F Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device. complete all as specified and directed by Engineer In Charge.
S & F Toilet paper holder, vitreous China,box type complete all as specified and directed by Engineer In Charge.
S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete complete all as specified and directed by Engineer In Charge.
S&F Cast iron nahani trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer In Charge.
S & F Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms/40mm-60 gms) cement complete all as specified and directed by Engineer In Charge.
S & F Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in Floors etc., any type of pipe 32mm dia cement complete all as specified and directed by Engineer In Charge.
S & F Vitreous China wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and orcelain stopper but including bracketscement complete all as specified and directed by Engineer In Charge.
S & F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer In Charge.
M&L tubes medium grade galvanised, with all fittings and fixed complete to walls or ceiling or laid in floors 15mm bore dia. complete all as specified and directed by Engineer In Charge.
S&F Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. of nominal Outer diameter of pipes 20 mm complete all as specified and directed by Engineer In Charge.
S&F Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. of nomina Outer diameter of pipes 25 mm complete all as specified and directed by Engineer In Charge.
M&Lof Ball valve high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete 25mm dia complete all as specified and directed by Engineer In Charge.
S&F of Rotational moulded polyethylene water storage tanks (Cylindrical verticval with closed top) hoisted & fixed in position all as specified of 1000 ltrs capacity complete all as specified and directed by Engineer In Charge.
S & F stop valves 15mm bore dia, cast copper alloy fancy type, chromium plated with long shank and cup concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer In Charge.
S & F Angular Stop Cock with Wall Flange 15mm bore dia, cast copper alloy fancy type complete all as specified and directed by Engineer In Charge.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer In Charge.
S&F 20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer In Charge.
S&F 25 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer In Charge.
M&L for Mild framed works such as, etc as in large and small gates and grills , gratings and angles, tees , channels chainlink fenching etc, including hanging gates in pillar with proper pintle hinges, stops, hand made sliding bolts ,etc complete all as specified and directed by Engineer In Charge.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.complete all as specified and directed by Engineer In Charge.
Surface exvcavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil
Hardcore of broken stone guage exc 63mm but n.exc 100mm deposited spreqad and levelled in layers n exc 15cm thick, watered and rolled/rammed to a true surface using broken stone or boulders
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.50 m above the starting point.
M&L 100 mm thick Cement con
crete type D2 1:4:8 (40mm graded aggregates) as in sub base etc finished surface even and rough without using extra cement, complete.
All as as per
M&L for sand filling under floor or in foundations including watering and cosolidation .
Excavation in trenches n.exc 1.50m wide and n.exc 1.50m in depth for fdn etc n.exc 10 sqm on plan and getting out in any type of soil complete all as specified.
M&L for cement concrete 1:4:8 type D-2 as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes of 150mm dia pipes after they are laid and tested complete all as specified.
S&F for 150 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specfied and directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4.
M & L for rendering 15 mm thick on fair faces of brick/concrete surfaces in CM 1:4 finished even and fair complete all as specified and directed.
M&L for Providing precast cement concrete 1:2:4, type B1 (20 mm graded aggregate) set in CM 1:6, as in cover slabs (for manholes etc) with plain fair faces, all as spd.pd.
Each Set
Deduct Credit for Demolished/ Dismantled material Rs. (-) 0.00 (Minus) as listed in Schedule of Credit. Note1:- Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'. Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple bldgs having height 3 and above storey. Necessary scaffolding and saftey measures required during execution of work are including in this items.
M & L for point wiring complete with proper colour coding using 1100 volts grade, 1.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good the same in CM 1:3 to match with existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also inclduifng 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one light point/fan point controlled by one one way switch, complete all as specified and directed
M & L for point wiring complete with proper colour coding using 1100 volts grade, 2.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good the same in CM 1:3 to match with the existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc. also inclduifng 2.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one 5Pin,6/16Amps,Socket outlet independent,complete all as specified and directed
d and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm in any type of soil complete all as specified.
Supply & fixing switch modular type 16 Amp single pole one way 230V complete all as specified and directed by Engineer In Charge.
Supply & fixing socket modular type 6 Amp 2/3 pin single pole one way 230 V complete all as specified and directed by Engineer In Charge.
Supply & fixing socket modular type 16 Amp 2/3 pin single pole one way 230 V complete all as specified and directed by Engineer In Charge.
Supply & fixing modular fan regulator,120W- 2 module. complete all as specified and directed by Engineer In Charge.
Supply & fixing switch modular type 6 Amp single pole one way 230V completed all as specified and directed by Engineer In Charge.
Supply & fixing Modular white cover plate with frame 8 Module.complete all as specified and directed by Engineer In Charge.
Supply & fixing Modular white cover plate with frame 3 Module. complete all as specified and directed by Engineer In Charge.
Supply & fixing modular Metal Flush box 8 Module. complete all as specified and directed by Engineer In Charge.
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
M&L for providing 4 mm thick APP modified memberane in over (Inaccessible) RCC roof with the following specifiations :- (a) Cleaning existing surface properly. (b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density of 0.87 -0.89 Kg/Lit at 25 Degree Centigrade on the prepared dry roof surface. (c) Providing and Laying APP modified water proofing membrane reinforced with non wooven polyster matt with physical propertities as under :- (i) Membrane weight >3.6 Kg/Sqm . (ii) Net wooven polyster weight >160 gm/Sqm (iii) Softening point of membrane > 150o C (iv) Joint Tensile strength Longitudiual > 650 Sq Cm at 230o C & Transverse > 450/ Sq cm (v) Tear strength - Longitudual > 300 N & Transverse > 250 N Direction (vi) Elongation > 30 % (vii) Impermeability under water pressure > 3 Kg/Sq cm Note:- APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cm end lap. The laying of membrane shall be got done through authorised applicator of manufacturer of membrane. complete all as specified and directed by Engineer In Charge.
Supply and fixing integrated sleek extruded LED channel with acrylic cover 20 watt with white light having, Lumens shall not be less than 2000, P.F >0.95 and including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected. Make :Havells Cat No. LHEXBLP7PN1W020 /Crompton/Philips/Luker or equivalent.
Supply and fixing integrated sleek extruded LED channel with acrylic cover 10 watt with white light Lumens shall not be less than 1000, P.F >0.95 including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected. Make :Havells Cat No. LHEXACP7IN1W010 /Crompton/Philips/Luker or equivalent.
All as per item No 99 above but for one 5 pin socket 5 Amps on same board complete all as specified and directed
M & L for point wiring complete with proper colour coding using 1100 volts grade,4.0 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good the same in CM 1:3 to match with the existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc. also inclduifng 4.0 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for A.C Point Metal Socket outlet independent,complete all as specified and directed
Supply & fix exhaust fan 300 mm sweep, 1200 rpm, 230V complete with louvers, Plastic body, bolts, nuts, washers, suitably embedded in wall(include wall cutting for hole) with provisioning of 23/0.0076 flexible three core wire for electrical connections from ceiling rose to fan all as specified and directed.
Supply & fix sheet metal enclosure powder coated for MCB DB SPN 12 way double door with din rail and bus bar including making good to the disurbed surface matching with the existing complete alla s specified and directed.
Supply and fix MCB SP 240 volts 6 to 32 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply & fixing modular Metal Flush box 3 Module. complete all as specified and directed by Engineer In Charge.
Point
All as per item No 99 above but for one 5 pin socket outlet 05 Amp independent board complete all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for exposing getting out GI/CI/ UG cables pipes in Soft/loose soil all as specifie
M&L for sub main wiring complete two run of size 1.5 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable ,drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good in CM 1:3 to match with the existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected to common earth dolly and mains, complete all as specified and directed.(For Building security Lights) Note: Three run 1.5 Sqmm PVC cable and one run of Casing Caping & conduit will be measured as "one unit"length.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN and current carrying capacity 63 Amps in the DB complete with connection testing and commissioning. complete all as specified and directed.
Supply and laying DWC(Double Wall Corrugate) HDPE pipes of pressure rating 6 Kg/Cm sq of size 40 mm internal dia IS: 16205(Part 24):2018 laid in trenches complete all as specified and directed.Make : dutron/Tirupati or any equivalent ISI Make approved by the GE.
Supply and laying cable LT XLPE insulated and screened PVC bedded, galvanised steel strip armoured electric power cable 16 sq mm 4 core (heavy duty) with Multi stranded aluminium conductor, 1100 Volts grade complete all as specified and directed by Engineer in charge.
Supply and Fixing GI tubing, Light grade 50 mm dia bore of pipes for cable laying under road crossing Complete all as specified and directed.
Material and labour for RCC 1:2:4 type B1 (using 20mm graded stone aggregate) for filling the disturbed road opening for cable crossing include levelling with road surface and smooth finishing complete all as specified and directed.(for Road Cutting Repair)
M&L for 2nd class hardwood of Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints, supplied and fixed complete all as specified and directed by Engineer In Charge.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
TENDERDOCUMENTS.pdf
Tender Documents • 1.44 MB
BOQ_828553.xls
BOQ • 2.99 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .