| 1 | L1₹67.6 LAccepted-AOC COLABA MUMBAI | L1 | Accepted-AOC QUOTED L1 | |
| 2 | L2₹78.5 L+₹10.8 L (16.0%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-AOC NOT QUOTED LOWEST | |
| 3 | L3₹84.6 L+₹17.0 L (25.1%)Rejected-AOC BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-AOC NOT QUOTED LOWEST | |
| 4 | Rejected-Technical 15 401 PREM JOT COMPLEX ANIKET CO OP HSG SOC LTD NEAR INDIAN OIL NAGAR GHATKOPAR MANKHURD LINK ROAD GOVANDI CHEMBUR W MUMBAI 400043 | MUMBAI | MUMBAI | MAHARASHTRA | 400043 | - | Rejected-Technical Not admitted | |
| 5 | Rejected-Technical FLAT NO 1 PLOT NO 54 GRD FLOOR TULSI ASTHA NEAR SHRI ANAND RUSHIUDYAN SECTOR 12 VASHI NAVI MUMBAI 400 703 | THANE | MAHARASHTRA | 400703 | - | Rejected-Technical Not Admitted |
Tender Value
₹85 L
EMD Value
₹1.5 L
Closing Date
17 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
AUGMENTATION OF POWER SUPPLY AND ALLIED WORKS SERVICES FOR PROJECT NCN AT NRS THANE MUMBAI UNDER GE NW MANKHURD
2020_MES_331134_1
8843/E8
Open Tender
Civil Works
Item Rate
240 days
THANE
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) MANKHURD
₹1.5 L
Yes
31 Oct 2020
18 Jun 2020
21 Sept 2020
18 Jun 2020
17 Sept 2020
8 Sept 2020
60 days
Amount
SCH 'A' PART-I : BLDG WORKS" Total of Schedule 'A' Part-I brought forwarded from Serial Page No. 18
SCH 'A' PART-II "EXTERNAL ELECTIFICATION " Total of Schedule 'A' Part-II brought forwarded from Serial Page No. 19(R) & 20(R).
SCH 'A' PART-III "INTERNAL ELECTRIFICATION" Total of Schedule 'A' Part-III brought forwarded from Serial Page No. 21(R) & 22(R).
SCH 'A' PART-IV "MISC WORKS" INTERNAL & EXTERNAL ELECTIFICATION
Supply, install, testing and commissioning of copper wound power transformer step down, indoor type 630 KVA, oil cooled (ONAM) complete with standard fittings HT 22 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapping on HT side to vary secondary voltage within limit, all as per IS : 1180 (2014 Part-I & latest) and conforming to energy efficiency level -III The transformer shall be provided with first filing oil and following fittings:- (a) Rating and terminal marking plates with diagram.. (b) Oil level gauge indicating oil level minimum and maximum including temp meter. (c) Lifting lugs. (d) Plain breathing device which would not permit ingress of rain water and insects. (e) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug. (f) Thermometer pocket with Thermometer. (g) Oil conservator tank with filter type drain valve and filling cap including bucchhol relay. (h) Four Nos of Bi directional plain roller (j) Cable termination box both on HV/LV side. (k) Windting Temperature Indicator with provision for alarm contact. (l) Oil Temperature Indicator with provision for alarm contact. (m) Neutral terminal with provision for Cable termination & earthing. (n) Oil drain valve. (o) Explosion vent. (p) Marshalling Box, inspection cover. (q) Two earthing terminals for body earthing and two for neutral brought out on a bushing. (r) Electronic Governor (s) Vector Gp : Dyn-II Make - Schneider /ABB/Bharat Bijlee/ Crompton Greaves. Note : Transformer shall be got tested by contractor from the senior electrical inspector in permisses of office to be detailed by Accepting Officer, before dispatch and arragement for testing shall be born by the contractor and deemed to be included in quoted rates.
Supply, installation, testing and commissioning of RMU in door type, manual operation, extensible type (one incoming - Isolator) and two out going (Breaker)) of 22 KV, 3 phase, 50 Hz, 16 KA/3 Sec, 630 Amp 3 wire SF-6 gas insulated confirming to IEC 67221/IEC 60694 earthed neutral, breaking capacity 20 KA IP 4X degree protection, indoor, free standing metal clad SF6 Ring Main Unit comprising of the followings:- INCOMER LBS :- (01 No). (a) Manual operated 630 A load breaker switch with built-in-earth switch with full making capacity - 01 No. (b) Mechanical position indicator, switch ON/OFF/EARTHED - 01 No. (c) Live cable indication - 01 No. (d) Cable compartment cover interlocked with earth switch - 01 No. (e) Cable termination bushings suitable for 03 No. 1core x 300 Sqmm XLPE cable - 03 Nos. (f) 22 KV Screened cable termination kit with boots - 01 Sets. (g) NO/NC contact for - 01 Set. (i) Isolator ON/OFF. (ii) Earth Switch ON/OFF. (iii) Fault indictor Operated. (h) Command output for - 01 Set. (i) Isolator close. (ii) Isolator open. OUTGOING VCB :- 02 Nos Each outgoing VCB feeder consists of :- (a) Motorised 630 A Vacuum Circuit Breaker with manual spring charging arrangement and manual close & open push buttons, ON/OFF indication and series trip coil for self powered relay & shunt trip coil for external tripping - 01 No. (b) Self powered Numerical O/C & E/F relay type CSDPR with CTs of ration 100-50/1A, 2.5VA, 5P10 for 100/1 and 10P10 for 50/1 (Protetion core) & 100-50/1A, 2.5VA, CI 0.5 for 100/1 and CI 1 for 50/1 (Metering core)- 01 Set. (c) Manually operated 630 A load breaker switch with built -in-earth switch with full making capacity-01 No. (d) Mechanical position indicator switch ON/OFF/EARTHED -01 No. (e) Live cable indication -01 No. (f) Cable compartment cover interlocked with earth switch -01 No. (g) Cable termination bushings suitable for 01 No. 3 core x 150 Sqmm XLPE cable -03 No. (h) 22 KV screened cable termination kit with boots -01 Set. (j) NO/NC contact for -01 Set. (k) Breaker ON/OFF. (l) Relay Operated. (m) SF 6 Gas pressure indicator with auxilary contacts. (n) Handle for RMU - 01 No. (o) Fault passage indication with associated CT's (p) Battery & battery charger - 01 Set each. NOTE :- (i) The touch proof termination to be done under the supervision of OEM only. (ii) The three nos touch proof termination kits to be provided. (iii) The three nos Temperature sensors ( battery less, wireless, suitable to be placed directly on Live Bus bars in direct connection with Bus ) for monitoring in cable compartment of RMU to be provided. (iv) The RMU should be provided with self powered relay. The 230 V AC supply will be provided. Make - Schneider /ABB/Siemens.
Material and Labour for cable route indicator showing “MES LT U/G 22 KV” and route of cable with arrow (Should be embossed or engraved) made of RCC in suitable shape and fixed in PCC block 1:3:6 type C-2 using 40 mm graded aggregate 60 cm X 30 cm in ground, 30 cm below ground level and 30 cm above ground to show clear indication of cable including painting the complete slab with red paint and marking the engraved/embossed letters/arrow with white paint.
M & L for existing road cutting road/Hard standing not exc 60x90 cm in wide & depth getting out excavated material for laying HDFE pipe, returing filling & well rammaing watering finish surface 30 cm from top using PCC 1:3:6, including removal of surpluse soil all as directed.
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed
S & F MCB SPN 16-32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity, complete all as specified and directed.
S & F MCB SP 6 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity, complete all as specified and directed.
S&F surface, hanging and wall mounted batten (Double side connection) suitable for LED tube 20/22 watts, 230 volts alongwith tube rod 22 watt (double side connection), including fixing mounting blocks 2 Nos, 15 mm MS conduit if required, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed . Make : Havells/Bajaj/Pyrotech/Crompton/Benlo/ Halonix
S & F building Security light fitting 30 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP65 protection and impact resistance of IK07 including fixing arrangements complete. Make : Havells/Bajaj/Pyrotech/Crompton/Benlo/ Halonix
M & L for bracket made out of GI pipe 32 mm dia Light grade, 1.2 mtr long bent to shape with MS flat iron clamps made out of 40mmX 6mm thick FI nuts, bolts complete all as directed by Engr-in-charge.
Supply and fix HV insulation mat of class C, 3mm thick grade conforming to IS 15652 of latest amendment of width 1 mtr x 10 mtr long.
Supply & fix Heavy duty Exhaust fans AC single phase 230/ 240 of size 450 mm sweep , 900 RPM including louver and fittings complete. Make : Crompton/Havells/Bajaj/Lucker
Shree Ayyappa Engineering
AGRAWAL ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .