Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹2.0 Cr+₹38.2 L (23.6%)Rejected-Finance | ₹2.0 Cr+₹38.2 L (23.6%) | L2 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹1.5 Cr
EMD Value
₹2.3 L
Closing Date
2 Nov 2023, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
COMPLETION OF INCOMPLETE WORK FOR PROVN OF OTM ACCN FOR 17 MTN DOU (PH-I) AT BURDONG
2023_MES_618432_2
CWE/136-WE/39 of 2023-24
Open Tender
Civil Works
Lump-sum
364 days
Gangtok
Class B, Category a(i)
8 documents required · 8 mandatory
₹1,000
GE Gangtok
₹2.3 L
8 Jan 2024
13 Sept 2023
3 Nov 2023
13 Sept 2023
2 Nov 2023
13 Oct 2023
13 Sept 2023 - 25 Sept 2023
Amount
BUILDING WORKS
Lump sum price worked out by the Contractor for “(BUILDING WORKS)” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 1,37,500.00 inserted by the MES in Schedule ‘A’ Part-I
EXCAVATION AND EARTH WORK
Lump sum price worked out by the Contractor for “ EXCAVATION AND EARTH WORK ” as listed in Schedule ‘A’ Part- II. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 71,188.98 inserted by the MES in Schedule ‘A’ Part-II
INTERNAL WATER SUPPLY
Lump sum price worked out by the Contractor for “(INTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part- III. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 53,398.04 inserted by the MES in Schedule ‘A’ Part-III
INTERNAL WATER SUPPLY (Misc Items), Sch A Part III(A)
Supply, fixing, connecting and testing UV stabilised, anti microbial fusion welded 3 layer PP-R pipes 40 mm outside dia with and including brass threaded PP-R fittings duly clamped or concealed in walls or laid in floors complete all as specified and as directed.
All as per item No. 4.10 above, but 25 mm outside dia pipe.
All as per item No. 4.10 above, but 20 mm outside dia pipe.
All as per item No. 4.10 above, but 16 mm outside dia pipe.
Supply and fixing 3 layer PP-R gate or globe valves, UV stabilised, anti microbial fusion welded fixed complete for PP-R pipes of size 40 mm outside dia complete all as specified and directed.
All as per item No. 4.50 above, but for 25 mm outside dia pipe.
All as per item No. 4.50 above, but for 20 mm outside dia pipe.
All as per item No. 4.50 above, but for 16 mm outside dia pipe.
SUB TOTAL
INTERNAL ELECTRIFICATION
Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part- IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 75,054.63 inserted by the MES in Schedule ‘A’ Part-IV
INTERNAL ELECTRIFICATION (Misc Items), Sch A Part IV(A)
Material and labour for point wiring with 2.5 sqmm (nominal area) PVC insulated unsheathed stranded copper conductor (1100 V grade) FRLS cable drawing in and including PVC rigid concealed conduit of suitable dia, ISI marked, medium grade with all conduit fittings and accessories for one light point controlled by one switch alongwith PVC insulated cable with solid copper conductor of size 1.5 sqmm and connected to earth dolly including fixing of 1.6 mm thick MS sunken terminal box suitably flushed to wall with 3.0 mm thick plastic laminated/ebonite sheet cover fixed with brass screws & cup washer for circuit of 150 watt, 4 nos medium bay sodium vapour lamp complete all as specified and directed. (NOTE :- (i) 4 Nos medium bay sodium vapour light shall be controlled by one switch. The switch controls shall be provided outside of the store at 1.5 mtr distance from the ground level near entrance. (ii) The average length of point wiring shall be considered as 35 meters).
All as per Item No. 6.10 above but for circuit of 150 watt, 2 nos medium sodium vapour lamp controlled by one switch.
Supply and fixing energy efficient fluorescent tube light fitting 1 x 28 watt (T-5), surface mounting type with and including OEM tube rod, electronic ballast, lamp holder, connector block, prewired mounted on wall/ceiling and necessary electrical connections with copper flexible cable of suitable size complete all as specified and directed. (MAKE : Asian, Model No. ASTRA, Cat No - RTU7389 / BAJAJ, Cat No. BTIP 128 LHD or equivalent model in PHILIPS/GE/HAVELLS)
Fixing only energy efficient fluorescent tube light fitting 2 x 28 watt (T-5) FTL with all accessories and lamp duly prewired and mounted on wall/ceiling and necessary electrical connections with copper flexible cable of suitable size complete all as specified and directed. (NOTE : Tube light fiiting and tube rod shall be issued under Schedule 'B' as free for fixing only)
All as per Item No. 6.30 above, but of 1 x 14 watt (T-5) FTL complete. (MAKE : Asian, Model No. Pearl Supra SX, Cat No. - LBAXW13J00 / BAJAJ, Cat No. BTIP 114 LHD or equivalent model in PHILIPS / GE/HAVELLS)
Supply and fixing CFL light fittings epoxy ivory powder coated sheet aluminium housing with epoxy powder coated CRCA sheet steel gear tray, clear acrylic cover and accessories suitable for and including 1 x 36 watt OEM CFL lamp complete with all accessories and 40 mm bore GI pipe light grade mounting bracket not exceeding 1.5 meters long consisting of mild steel clamps made out of 40 mm x 6 flat iron with nuts & bolts of appropriate size including necessary connection with 3 x 1.5 sqmm PVC insulated stranded copper cable not exceeding 2.0 metre from ceiling rose complete all as specified and directed. (MAKE : BAJAJ, Cat No. BJSLA 136 CFL / WIPRO, Cat No. WSP11136 or equivalent model in PHILIPS / GE/HAVELLS)
All as per Item No. 6.60 above, but suitable for 2 x 24 watt (T - 5) fluorescent tube light fitting including lamp complete. (MAKE : BAJAJ, Cat No. BTSLF 224 MS / ASIAN, Model - TBA street light MONO or equivalent model in PHILIPS / GE)
All as per Item No. 6.60 above, but suitable for 1 x 28 watt (T - 5) fluorescent tube light fitting including lamp complete. (MAKE : BAJAJ, Cat No. BTSLF 128 T5 / ASIAN, Cat No. ADJAW13J00 or equivalent model in PHILIPS / GE)
Supply and fixing weather proof bulk head luminaire for 9 watt CFL including OEM CFL lamp and necessary electrical connections with suitable copper cable complete all as specified and directed. (MAKE : BAJAJ, Cat No. BJBE 19 / PHILIPS, cat No. FXC 101 / WIPRO, Cat No. WKP14109)
Supply and fixing surface mounting CFL lumainaire comprising of white moulded metal housing complete with all internal accessories including OEM CFL lamp suitable for 1 x 9 watt CFL and necessary electrical connections with suitable copper cable complete all as specified and directed. (MAKE : HAVELLS, Model - MATRIX, Cat No. LHDC17109030F or equivalent model in BAJAJ / PHILIPS / GE)
Supply and fixing baked enamel metalware omnidirectional light with swivel joint for to and fro movement, ideally suitable for bed heads and reading purposes having base dia 85 mm, collar 25 mm and shade dia 110 mm, material aluminium sheet finished dull black, porcelain holder including OEM CFL lamp suitable for 1 x 5 watt CFL and necessary electrical connections with suitable copper cable complete all as specified and directed. (MAKE : JEMCO, Model - SK8 or equivalent model in BAJAJ / PHILIPS / GE)
Supply and fixing vertical mounting integral medium bay luminaire including reflector with toughened glass cover suitable for 150 watt sodium vapour lamp with and including 1 x 150 watt SON (T) lamp and other accessories and necessary electrical connections with suitable copper cable complete all as specified and directed. (MAKE : BAJAJ, Cat No. BJHBI 150 SV Hsg for control gear and 180364 for reflector with glass / HAVELLS, Cat No. LHYS03115A99 for housing and LHBW08115036 for ballast and LHYW 02140099 for reflector and LHYW 21140099 for glass). (NOTE : Necessary hooks shall be provided at the time of casting of roof/floor for hanging of lumainaire fittings)
Supply and fixing electronic type ceiling fan speed regulator stepped type suitable for 230 Volts, AC, complete all as specified and directed. (MAKE : ANCHOR, Model - Penta Deluxe, Cat No. 38660 or similar model in MERLIN GERIN)
Supply and fixing switched wall socket without interlocking and protection level IP - 44 and type 2P + E and rating 20 Amps including plug top complete all as specified and directed. (MAKE : HENSEL, Cat No. AT110306 for socket & Cat No. 210306 for plug top or any other equivalent make)
Supply and fixing single phase motor starter suitable for 230 Volts, AC, 25 Amps rating complete all as specified and directed. (MAKE : ANCHOR, Model - Penta Motor Starter, Cat No. 52467or similar model in MERLIN GERIN)
Supply and fixing blanking kits for MCB DBs complete all as specified and directed.
Material and labour for sub main wiring with PVC insulated unsheathed, stranded copper conductor cable 1100 Volts grade of size mentioned below including PVC insulated cable of stranded copper conductor cable for earth contunity of size mentioned connected to common earth dlly and to be drawn in concealed heavy duty regid PVC conduit of size mentioned below :-
(a) 2 x 6.0 sqmm + 1 x 2.5 sqmm (size of conduit shall be 25 mm)
(b) 2 x 10.0 sqmm + 1 x 6.0 sqmm (size of conduit shall be 40 mm)
(c) 4 x 10.0 sqmm + 1 x 6.0 sqmm (size of conduit shall be 40 mm)
(d) 4 x 16.0 sqmm + 1 x 6.0 sqmm (size of conduit shall be 40 mm)
NOTE: -(i) Only 2 or 4 run of line conductor and one run of earth continuity conductor shall be measured as one unit length. Conduit shall be measured separately. Suitable No. of inspection boxes shall be provided in the conduit for drawing of wires and for inspection. The quantity on circular inspection boxes shall be measured under respective items) (ii) Conduits shall be measured & paid seperately under respective items.
Supply and fixing heavy duty PVC flexible conduit ISI marked of the under mentioned size complete all as specified and directed :
(a) 25 mm dia
(b) 40 mm dia
Supply and fixing PVC coupler/gland complete with check nut sealing ring suitable for PVC flexible pipes of the under mentioned size complete all as specified and directed :
(a) 25 mm dia
(b) 40 mm dia
Supply and fixing double door MCB DB TPN horizontal type for single phase outgoing made of steel sheet, phosphatised powder coated, with bus bar, neutral link, earth bar and din rail and having IP 42 protection for the under mentioned size complete all as specified and directed.
All as per Item No. 8.90 above, but for SPN incomer and outgoings as mentioned under complete :
(c) 2 + 4 way (NOTE : Necessary arrangement shall be made for installation of SPN MCB as outgoing for isolation of phase and neutral both for each outgoing circuit as mentioned in the drg. Cost of the same shall be deemed to be included in the quoted rates)
Supply and fixing sheet steel powder coated cable end box (semi concealed type) with front hinged door and shall be mounted on top or bottom of distribution box for looping of extra cables/wires for the under mentioned sizes :-
(a) SPN 4 way
(b) SPN 8 way
(c) SPN 12 way
(d) TPN 4 way (for horizontal/vertical DBs)
(e) TPN 6 way (for horizontal/vertical DBs)
Supply, installing, testing and commissioning of indoor type LT Panel board, wall mounted, semiconcealed, CPRI type tested & conforming to IS specificetion factory made, totally enclosed, dust and vermin proof, made of 1.6mm (16 gauge) thick CRCA sheet and having dimension of 750 mm x 750 mm x 150 mm duly fabricated and powder coated and suitable for AC 415 Volts 50 HZ 3 Phase 4 wire system complete all as shown on drawings, with & including comprising of the followings for SM Barrack :- INCOMING:- MCCB 415 Volts, 3 Phase, 50 C/S, 4 pole, 100 Amps with breaking capacity 25 KA with adjustable type thermal and magnetic setting (70% - 100%) - 01 No BUS BAR:- Bus bars shall be made of tinned copper strip of size 20mm x 3 mm (200 mm long) rigidly mounted on bakelite bus bar insulator of suitable size and bus bars shall be covered with PVC sleevings of standard colour code - 1 set (set of 4 bars) OUTGOINGS:- (i) MCB, 'C' curve with rupturing capacity 10 KA of the following ratings :- (i) 50 Amps TPN - 1 No (ii) 40 Amps TPN - 1 No (iii) 32 Amps TPN - 1 No (iv) 32 Amps SPN - 1 No CONTROL SYSTEM:-(i) Indicator lamp with integral circuit (230/240 Volts) and cluster LED (RED-YELLOW-BLUE) - 02 Set (Set of 3 Nos) for mains supply and generator supply respectively. (ii) Bakelite slide locking type control fuse, 5 Amps rating - 06 Nos (iii) Aluminium danger notice plate 415 Volts / 440 Volts and of size 150mm x 100mm suitable for panel board - 01 No
NOTE : (i) All internal connections for power lines shall carried out with 1100 volts grade PVC insulated (FRLS) unsheathed single core copper wire or insulated copper strips of same cross sectional area of suitable size & terminated with heavy duty tinned copper lugs. (ii) All control wiring shall be done with 1100 Volts PVC insulated (FRLS) unsheathed flexible type single core copper wire of size 1.5 Sqmm and terminated with tinned copper lugs. (iii) Incoming cable shall be entered into the panel from bottom and all outgoing cables shall be exit from the panel through top or as directed by Engr-in-Charge as per requirement at site.
Material and labour for earthing complete with galvanised steel earth plate electrode of size 60 cm x60 cm x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge not less than 1.5 m below ground level,connected to galvanised wire 4.0 mm dia as earth lead by means of bolts, nuts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR part I, connected to earth test point all as specified or indicated complete with excavation, earth work, PCC 1:3:6 pit with RCC M-25 design mix concrete cover, 50 mm thick reinforced with hard drawn steel wire fabric weighing exceeding 4 Kg/Sqm with suitable handle made of 10mm dia MS bar, 20mm bore GI tubing medium grade for watering pipe, 15 mm bore & 7.5 mtrs medium grade GI pipe for protection of 4.0mm dia GI earth lead, test point, GI funnel with wire mesh all as directed and specified and testing on completion.
SUB TOTAL
EXTERNAL WATER SUPPLY
Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Section V ( Part- V). Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 63,281.97 inserted by the MES in Schedule ‘A’ Section V (PART-V)
EXTERNAL WATER SUPPLY (Misc Items), Sch A Part V(A)
Material and labour for construction of brick masonary valve pit of size 600 mm x 600 mm x 600 mm (Internal dimension), including MS pit cover complete including necessery excavation and earth work complete all as specified and as shown on drgs
Supply and fixing gun metal gate or globe valve ISI marked, with iron wheel head, screwed both ends for iron pipe and fixed for 80 mm bore pipe complete all as specified and directed.
Material and labour for cutting the existing GI tubing 80 mm bore and inserting new Tee branch 80mm x 80mm x 80 mm with and including necessary specials such as nipple, socket, union etc complete all as specified and directed.
SUB TOTAL
EXTERNAL ELECTRIFICATION
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part- VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 1,21,638.43 inserted by the MES in Schedule ‘A’ Part-VI
EXTERNAL ELECTRIFICATION (Misc Items), Sch A Part VI(A)
Laying only, testing including end termination of LT cable with stranded aluminium conductor, 1100 volt grade, of 3.5 core 120 sqmm size complete all as specified and directed. (NOTE :- Cables shall be issued under Schedule 'B' as free for laying only).
All as per item No. 14.10 here in above but 3.5 core 70 Sqmm
All as per item No. 14.10 here in above but 3.5 core 35 Sqmm
All as per item No. 14.10 here in above but 4 core 25 Sqmm
All as per item No. 14.10 here in above but 2 core 16 Sqmm
All as per item No. 14.10 here in above but 3.5 core 240 sqmm
Supply, jointing and testing outdoor type cable termination (cold shrink push on type) suitable for 3 core 11 KV underground cable XLPE insulated of size 3 core 95 sqmm complete all as specified and directed.
All as per item No 14.70 above but indoor type.
Supply and fixing HT 11 KV drop out fuse assembly 3 phase of rating 60 Amps including insulator, steel frame and barrel fuse with 3 Nos with barrel type insulators complete all as specified and directed.
Supply, installation, testing and commissioning transformer, step down, 11KV/433 volts complying with IS: 2026 (part-I) 1977, indoor type, double copper wound, suitable for AC three phase 4 wire, 50 Hz system capacity 200 KVA, oil immersed, naturally cooled, delta connected on HT side and star connected on LT side, provided with manually operated circuit tap changer on HT side to vary secondary voltage to 7.5% in steps of 2.5% each, with standard fittings and accessories all as specified in MES Schedule Part-I and with cable end box at HT/LT side with neutral brought out, complete with first fill of transformer oil (conforming to IS 355) to maximum level, temperature gauge, silica gel breather, oil tank with level gauge, LT side cable box to be fitted with suitable size cable gland, connecting with the electrical system and installing the transformer in accordance with IS 10028 (Part-II) - 1981 complete all as specified and directed. (Note : Platform for mounting the transformer shall be measured and paid for separately under relevant items of this schedule).
Supply and fixing energy efficient street light fittings suitable for 4 x 24 watt T-5 fluorescent lamp complete with 4 Nos 24 watt T-5 lamps, lamp holder, reflector, acrylic cover, electronic ballast and to be fixed with and including all necessary electrical connections with necessary connection with 2 X 1.5 Sqmm PVC insulated aluminium cable duly connected from OH line to connector block of cable with and including street light bracket made out of GI pipe light grade 32 mm dia 0.8 mtr length bent to shape and reduced to required size at top upto 1.5 m length by cutting, welding and well finishing including MS clamp of flat iron of size 40 x 6 mm suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painting with two coats aluminium paint over a coat of red oxide primer complete all as specified and directed. (Make - ASIAN Cat No. ABFAS43S10 / BAJAJ Cat No BTSLF 424 DD or similar model in PHILIPS / GE)
Supply and fixing glass fibre reinforced UV protected polycarbonate junction box, for mounting on the street light pole coping of size 200 mm x 160 mm x 98 mm complete with 1 No SP MCB 3 Amps and one number 5 way ELMEX terminal suitable for 16 Sqmm cable complete with dust / water proof and with IP 65 protection complete all as specified and directed. Note :- This box shall be embeded in the pedestal of the steel tubular pole. Main cable shall be looped in the box and tapper for individual light fittings. (MAKE - HENSEL / RITTAL / GEWIS)
Material and labour for earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge not less than 1.5 m below ground level,connected to galvanised wire 4.0 mm dia as earth lead by means of bolts, nuts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR part I, connected to earth test point all as specified or indicated complete with excavation, earth work, PCC 1:3:6 pit with RCC (1:2:4) type B-1 cover 50 mm thick reinforced with hard drawn steel wire fabric weighing exceeding 4 Kg/Sqm with suitable handle made of 10 mm dia MS bar, 20mm bore GI tubing medium grade for watering pipe, 15 mm bore & 7.5 mtrs medium grade GI pipe for protection of 4.0mm dia GI earth lead, test point, GI funnel with wire mesh all as directed and specified and testing on completion.
All as per Item No. 15.30 above but with GI strip of size 25 x 4 mm as earth lead conductor and protection pipe of 40 mm bore.
Supply , installation, testing and commissioning LT feeder pillar box, CPRI type tested and conforming to all relevant IS standards factory made, outdoor type, platform mounted, dust and vermin proof of over all dimensions 1.00m x 0.75m x 0.40 m depth, made out of 3.15 mm thick CRCA sheet with sloping canopy/gable roof, double door, front openable shutter and single door shutter in rear side with hinges and locking arrangement duly supported with 40 x 40 x 6 mm MS angle iron and 50 x 6mm MS flat iron frame drilled for fixing MCCB / MCBs etc all as required duly fabricated and powder coated of approved shade complete and with cable entry holes for incoming and outgoing cables and mounting the box in PCC grade M-10 platform 1.30m x 0.85m x 0.75m size finished even and smooth using extra cement complete including supply and fixing the following items/accessories/ equipment :- (Note :- Cost of PCC platform included in the cost of LT feeder piller box). INCOMING:- MCCB 415 Volts, 3 Phase, 50 C/S, 4pole, 100 Amps with breaking capacity 25KA with adjustable type thermal and magnetic setting (70% - 100%) - 01 No BUSBAR:-Bus bars shall be made of tinned copper strip of rated capacity 200 Amps rigidly mounted on bakellite busbar insulator of suitable size and busbars shall be covered with PVC sleevings of standard colour code - 4 Nos
OUTGOINGS:-(a) MCCB 415 Volts, 3 Phase, 50 C/S, 4pole, 40 Amp with breaking capacity 16 KA with adjustable type thermal and magnetic setting (70% - 100%) - 2 Nos . Note : (i) All internal connections for power lines shall be carried out with 1100 volts grade PVC insulated (FRLS) unsheathed single core copper wire or insulated copper strips of same cross sectional area of suitable size and terminated with heavy duty tinned copper lugs. (ii) All control wiring shall be done with 1100 Volts PVC insulated (FRLS) unsheathed multiflexible type single core copper wire of size 1.5 Sqmm and terminated with tinned copper lugs. (iii) Incoming cable shall be entered into the panel from bottom and all outgoing cables shall be exit from the panel through bottom or as directed by Engr-in-Charge as per requirement at site.
Supply, installation, commissioning and testing of diesel engine driven generating set of capacity 30 KVA/ 24 KW or nearby higher capacity, 1500 RPM, water cooled mounted on common base frame conforming to BS-5514 and IS-10002, rated for 415 Volts 50 cycles, 0.8 PF complete suitable for Burdong, considering all derating factor. with relay panel for automatic starting on main's failure and acoustic enclosure as per relevant IS with control panel complete all as under:- (A) Vertical multicylinder, cold starting in accordance with BS-5514 / IS : 10002 at 1500 RPM including the following accessories :- (i) Fuel Tank suitable for capacity for min 12 hrs run. (ii) Fuel Filter (Primary & Secondary) (iii) Fuel feed pump with governor. (iv) Lube oil filter (v) Lube oil cooler (vi) Dry / Oil both type aircleaner (vii) Exhaust silencer (Industrial type) (viii) Radiator with fan and mounting (ix) Fly wheel with starter ring (x) Expension bellow (xi) 12 V DC electric starter (xii) Battery charging alternator (xiii) Flexible coupling (xiv) Front & rear engine mouning support (xv) Engine control panel consisting of :- (a) ON / OFF start key (b) Lub oil pressure guage
NOTE : (i) Anti vibration pads of suitable size shall be provided. (ii) Foundation / platform of DG set to be made as per manufacturers instruction. Provision shall be made to drain out used lube oil during replacement. (iii) Exhaust pipe of engine is to be extended out of the building with suitable dia of MS pipe duly painted with anti corrosive paint and insulated with suitable dia asbestos rope duly claded with plaster of paris the cost for the same shall deemed to be included in the unit rate of DG set. (iv) First fill of lubricating oil and fuel shall be provided by the contractor during testing of engine. The cost for the same shall deemed to be included in the unit rate of DG set.
Supply, installation, commissioning and testing of electric motor siren conforming to IS:1941, suitable for three phase 415 volts supply with motor not exceeding 3.75 KW power and able to deliver 143 DB noise level upto a distance of 1000 mtr including necessary starter, switch fuse unit of suitable capacity and having automatic equipment for producing a warbling note including necessary electric connections complete all as specified and directed.
SUB TOTAL
LIFT, Sch A Part VII
(iii) Micro - stroke 'M' type push buttons (iv) Infrared Beam (v) Press & Speak Phone (vi) Motor shall be of 15 KW(18.75 hp) Note : The system (Lift) shall be guaranteed against maintenance and repair for a period of one year from the date of completion of work and cost of the same is deemed to be included in the quoted rates. Lump sum price worked out by the Contractor for “(Incomplete supply, installation, testing and commissioning of freight elevator electrically operated complete with manually operated steel sliding door suitable to carry store at a speed of 0.4 m/sec (Approx) to serve from basement to second floor all as per the details and accessories given above)” as listed in Schedule ‘A’ Section VII ( Part- VII). TOTAL AMOUNT = 23,40,000.00 Add/deduct ______%(_________ percent) Rs_______________ Above / below (Note: Total cost is at par market, Bidder to quote total amount after considering percentage addition thereto to cover over head and profit as per Condition 5 of IAFW-2249 )
AUTOMETIC BARRIER, Sch A Part VIII
Supply, installation, testing and commissioning electric operated Automatic Boom Barriers, 200-240 volts AC, 12-24 volts DC, 50 Hz, weight 160-200 Kg (appprox), boom length 13-18 feet and adjustable opening timing 6-12 seconds with single wing including induction motor, DOL starter, electronic control, steel wire, winch of suitable size, concrete pillar, electric cable and limit switches all as per following specifications :- (a) Drive Mechanism : Electromechanical drive unit operated by microprocessor based control panel. The drive unit shall consist of gears, shaft, crank, safety clutch and ball bearing etc. which shall be encapsulated in weather proof oil filled chamber for maintenance free and long lasting performance. The operation of the drive unit shall be silent and maintenance free. In case of power failure both manula as well as battery back up operation shall be available. (b) Electric Motor : Motor shall be 24 Volts DC, 900 rpm, 1/4 HP, 40 watt, maintenance free, reversible motor, designed for heavy duty operation. The motor shall be able to provided dual speed so that optimum time for opening and closing with soft landing, opening and closing time (2-15 seconds) can be adjusted at the sitting during installation depending on traffic frequency and boom length. (c) Control Panel : The electronic control panel shall control the direction and speed of the boom movement and shall be capable of accepting optional safety devices such as beam sensor, magnetic card reader, loop detector etc. The control panel shall be fixed in guard room or inside the barrier box as directed by the Engr-in-Charge.
(d) Push Button : A piano type push button shall be provided in the guard room. The barrier shall be activated by touching the push button for a second, thus keeping the guard free to pay more attention to security checks. (e) Remote Control : Suitable arrangement shall be made to activate the barrier by remote control from a distance upto 100 feet depending upon the local environment conditions.
SUB TOTAL
ROAD & PATH
Lump sum price worked out by the Contractor for “(ROAD & PATH)” as listed in Schedule ‘A’ Part- IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 2,71,106.03 inserted by the MES in Schedule ‘A’ Part-IX
PROTECTIVE WORK
Lump sum price worked out by the Contractor for “(PROTECTIVE WORK)” as listed in Schedule ‘A’ Part- X. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 40,038.32 inserted by the MES in Schedule ‘A’ Part-X
SEWAGE DISPOSAL
Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part- XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 27,211.16 inserted by the MES in Schedule ‘A’ Part-XI
AREA DRAINAGE
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part- XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 91,397.13 inserted by the MES in Schedule ‘A’ Part-XII
COMPOUND WALL, FENCING & GATE
Lump sum price worked out by the Contractor for “(COMPOUND WALL, FENCING & GATE)” as listed in Schedule ‘A’ Part- XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 5,08,870.64 inserted by the MES in Schedule ‘A’ Part-XIII
DEMOLITION AND DISMANTLING
Lump sum price worked out by the Contractor for “(DEMOLITION AND DISMANTLING)” as listed in Schedule ‘A’ Part- XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 2467.17 inserted by the MES in Schedule ‘A’ Part-XIV
PROVN OF SHED FOR DG SET
Lump sum price worked out by the Contractor for “(PROVN OF SHED FOR DG SET)” as listed in Schedule ‘A’ Part- XV. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 36,548.35 inserted by the MES in Schedule ‘A’ Part-XV
DETAILS OF DEFECTIVE WORK WITH COST OF RECTIFICATION
Lump sum price worked out by the Contractor for “(DETAILS OF DEFECTIVE WORK WITH COST OF RECTIFICATION)” as listed in Schedule ‘A’ Part- XVIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 2,87,063.15 inserted by the MES in Schedule ‘A’ Part-XVIII
DETAILS OF DEFECTIVE WORK WITHOUT COST OF RECTIFICATION, Sch A Part XVIII(A)
The point wiring of exhaust fan is not connected with separate point wiring
Ceiling rose is not proper fixed and missing also
Switch Piano flush button single pole is not provided for exhaust fan seprately
M&L Earthing complete with galvanised steel earth plate electrode60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Pole Paintingnting of two coats of Al paint over primer coat of 11 Mtr long (2 pole structure) remain balance
M&L Earthing complete with galvanised steel earth plate electrode60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
M&L Earthing complete with galvanised steel earth plate electrode60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completionEarthing GI strip 25x3.15mm the funnel wall pit strip size not as per CA
Testing and commissioning only electric operated Automatic Boom Barriers, 200-240 volts AC, 12-24 volts DC, 50 Hz, weight 160-200 Kg (appprox), boom length 13-18 feet and adjustable opening timing 6-12 seconds with single wing including induction motor, DOL starter, electronic control, steel wire, winch of suitable size, concrete pillar, electric cable and limit switches all as per following specifications :- (a) Drive Mechanism : Electromechanical drive unit operated by microprocessor based control panel. The drive unit shall consist of gears, shaft, crank, safety clutch and ball bearing etc. which shall be encapsulated in weather proof oil filled chamber for maintenance free and long lasting performance. The operation of the drive unit shall be silent and maintenance free. In case of power failure both manula as well as battery back up operation shall be available. (b) Electric Motor : Motor shall be 24 Volts DC, 900 rpm, 1/4 HP, 40 watt, maintenance free, reversible motor, designed for heavy duty operation. The motor shall be able to provided dual speed so that optimum time for opening and closing with soft landing, opening and closing time (2-15 seconds) can be adjusted at the sitting during installation depending on traffic frequency and boom length. (c) Control Panel : The electronic control panel shall control the direction and speed of the boom movement and shall be capable of accepting optional safety devices such as beam sensor, magnetic card reader, loop detector etc. The control panel shall be fixed in guard room or inside the barrier box as directed by the Engr-in-Charge. (d) Push Button : A piano type push button shall be provided in the guard room. The barrier shall be activated by touching the push button for a second, thus keeping the guard free to pay more attention to security checks. (e) Remote Control : Suitable arrangement shall be made to activate the barrier by remote control from a distance upto 100 feet depending upon the local environment conditions.
SUB TOTAL
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
SANJAY SAW MILL
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .