| 2 | L2₹30.4 L+₹3.0 L (11.0%)Rejected-Finance ROOM NO 281 GANESH MARUTI NAGAR CAPTAIN PRAKASH PETHE MARG BACKBAY BUS DEPOT CUFFE PARADE MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹31.5 L+₹4.1 L (15.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹32.2 L+₹4.9 L (17.8%)Rejected-Finance 38 30 92 SAI NAGAR MARRIPALEM VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹33.8 L+₹6.4 L (23.5%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹75,000
Closing Date
21 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bihta
GE (AF) BIHTA PATNA-801103
IMPROVEMENT/UPGRADATION TO LIVING IN ACCOMMODATION OF AIRMEN AT AF STN BIHTA (PHASE-III)
2024_MES_639023_1
8380/BHT/E8
Open Tender
Civil Works
Item Rate
180 days
Bihta
Class D and above Cat a(i)
7 documents required · 7 mandatory
₹500
GE (AF) BIHTA
₹75,000
Yes
30 Mar 2024
25 Jan 2024
28 Feb 2024
25 Jan 2024
21 Feb 2024
9 Feb 2024
26 Jan 2024 - 1 Feb 2024
Amount
Dismantling of stone stabs & tiles of any description or thickness in floor, aprons etc and bedded & pointed in cement mortar and disposing off debris to a distance up to 250M, complete all as specified and directed.
Dismantling floor hearth or wall tilling incl cement mortar bedding (but not backing) & stacking at site as directed and disposing off debris to distance upto 250M, complete all as specified and directed.
Demolition of brick work/stone boulder masonry, built in CM incl all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc 15 cm thickness (below or above GL), complete all as specified and directed.
M&L for roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified and directed.
Taking down cement or cement lime plaster on walls, any description including racking out joints, hacking for key, scrubbing down with water etc. and removing rubbish, complete all as specified and directed.
M & L for 15 mm thick rendering in CM (1:6) on vertical surfaces of fair faces of brick walls, surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M & L for 15 mm thick rendering in CM (1:4) on vertical surfaces of fair faces of brick walls finished even and smooth without using extra cement with using water proofing compound (WPC will be measured and paid separately), complete all as specified and directed.
M & L for 5 mm thick rendering in CM (1:3) on ceiling surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
M&L newly plastered surfaces of wall and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick wall care putty, complete all as specified and directed.
M&L for newly plastered surfaces of walls applying two coat of cement base paint over a coat of primer, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed.
M&L for preparation of old previously treated surfaces of ceiling and applying two coats of white wash, complete all as specified and directed.
M&L for complete removal of existing treatment from previously treated wall surfaces and applying two coat of cement base paint over a coat of primer, complete all as specified and directed.
M&L for complete removal of existing treatment from previously treated wall surfaces and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick wall care putty, complete all as specified and directed.
M&L for old painted wooden surfaces and applying one coat of synthetic enamel paint (ordinary tint) of any description, over 10 cm in width or girth, not otherwise described, complete all as specified and directed.
M & L Granite 20 mm thk (Telephonic black) work (table rubbed and polished) in steps, jambs, pillars, window-cills, Wash basin platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
M&L joint free non skid ceremic tiles 7 to 8mm thk (square/ rectangular) area of each tile exc. 0.06sqm but not exc. 0.11sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles, laid over and including 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes, complete all as specified and directed.
M&L joint free glazed ceramic coloured tiles of approved quality ISI marked (350x250x7 mm / 450x 350 x 7 mm / 450 x 300 x 7 mm thick) as in vertical surfaces such as skirting dados etc set jointed in neat cement slurry and pointed in coloured cement to match with the tiles, laid over and including 1:4 cement plaster 10 mm thick on brick work and concrete surface, complete all as specified and directed.
S&F as in repairs PVC low/high level flushing cristern white 10 ltrs capacity incl PVC inlet pipe with brass check low level full both sides alongwith PVC flush pipe 32mm dia jointed to WC and handle incl brackets fixed in repairs, complete all as specified and directed. Note Removing existing flushing system of CI or any other quality incl brackets.
S&F in repair bib taps cast copper ailoy but fancy type, half turn, chromium plated, screwed down, screwed for iron pipe or for brass furrule and fixed for 15mm dia pipe, complete all as specified and as directed.
S&F in repair stop valves (Concealed type) cast copper alloy but fancy type, half turn, chromium plated screwed down, high pressure, screwed both ends for iron pipe or for union fixed in repair for 15 mm dia GI pipe, complete all as specified and directed.
S&F in repair stop valves cast copper alloy but fancy type, half turn, chromium plated scrawed down, high pressure, screwed both ends for iron pipe or for union fixed in repair for 15 mm dia GI pipe, complete all as specified and directed.
S&F in repair vitreous china squatting pan ORRISA PATTERN size 580x440mm white with integral foot rests excluding flushing cistem & flush pipe, fixed in repairs incl P or S trap, complete all as specified and directed.
S&F in repair Vitreous China urinals, half stall type, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in white cement; fixing with brackets, flush pipe, grating and Union for discharge pipe, complete all as specified and directed.
S & Fixed in repair Vitreous china wash basin white oval type size 560x410 mm including waste pipe and plug and porcelain stopper alongwith 32mm dia CP brass waste coupling and PVC waste pipe, complete all as specified and directed.
S&F in repair Pillar taps fancy type cast copper alloy, half turn with capastan heads, chromium plated, screwed down high pressure, with or without lettered HOT or Cold with long screwed shanks and fly nuts, screwed for iron/ CPVC pipe and fixed 15 mm dia of pipe, complete all as specified and directed.
S&F in Repair Chromium plated shower rose with or without swivel joints, 125 mm size, including fixing to steel pipe or union, complete all as specified and directed.
S&F PVC (SWR) floor trap 75 mm out let dia, plain with grating including jointing with solvent cement, complete all as specified and directed.
Taking up or down 15 mm bore galvanised iron tubing and connection including cleaning for refixing or removal, complete all as specified and directed.
Taking up or down 20 mm bore galvanised iron tubing and connection including cleaning for refixing or removal, complete all as specified and directed.
Taking up or down 25 mm bore galvanised iron tubing and connection including cleaning for refixing or removal, complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick walls, complete all as specified and directed.
S & F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors as in concealed/surface of 15 mm bore pipe complete all as specified and directed.
S & F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors as in concealed/surface of 20 mm bore pipe complete all as specified and directed.
S & F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors as in concealed/surface of 25 mm bore pipe complete all as specified and directed.
Demolition & breaking up drain pipes (SWG, AC, RCC etc) set in CM int dia of pipe 100 mm with all fittings, complete all as specified and directed.
Demolition & breaking up drain pipes (SWG, AC, RCC etc) set in CM int dia of pipe 75 mm with all fittings, complete all as specified and directed.
S/F PVC pipes (SWR) single socketed in any length with rubber ring joints laid in trenches or in floor for 110 mm dia pipe, complete all as specified and directed.
S/F PVC pipes (SWR) single socketed in any length with rubber ring joints laid in trenches or in floor for 75 mm dia pipe, complete all as specified and directed.
S&F PVC (SWR) bend 110 mm bore, any radius, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
S&F PVC (SWR) 110 mm bore single Junction 'T', equal or unequal, incl jointing to waste pipe with solvent cement, complete all as specified and directed.
S&F PVC (SWR) bend 75 mm bore, any radius, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
M&L brick work with pulverized fuel Ash-lime bricks (old size fly ash bricks), straight or curved on plan exc 6 m mean radius, built in CM 1:6, complete all as specified and directed.
M&L cement concrete type 25 mm thick B1, 1:2:4 mix using 20mm graded stone aggregates as in levelling course in floor and roof tops etc, complete all as specified and directed.
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed 20 mm thk in CM 1:6 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and wax polishing, complete all as specified and directed.
M & L Marble work 18 to 20mm thick (table rubbed and polished) in floors for border work in kota stone flooring, and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble of any shade over 20 mm thick screed bed in cement mortar (1:6), complete all as specified and directed. Note : Shade and tint of marble shall be as approved by GE.
M&L Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar, laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and wax polishing complete, laid over and including 10 mm thick plasteing in cement mortar (1:4) as a backing etc, complete all as specified and as directed.
M & L joint free Non-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles, laid over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
M & L joint free Non-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in vertical surfaces such as skirting etc set jointed in neat cement slurry and pointed in coloured cement to match with the tiles, laid over and including 1:4 cement plaster 10 mm thick on brick work and concrete surface, complete all as specified and directed.
Dismantling of Textile old roof coverings of any thickness including plastering, concrete padding including brick tiles or terracing tiles and removed spoil/rubbish out side MD land, complete all as specified and directed. Note :- (a) The surface shall be wire brushed and clean to receive the PCC/plastering. (b) Any mechanical item such as dish TV antena, Solar panel system incl its water tank and other accessory shall be removed and refixed after necessary repair work. The rate for the same shall be deemed included in this item.
M&L for rendering 10mm thick in CM 1:3 on concrete surfaces / slabs finished even and smooth without using extra cement with admixture of integral water proofing compound @ 3% by weight of cement for filling depressions if any to receive water proofing treatment (WPC shall be measured & paid seperately), complete all as specified and directed.
M&L for applying bitumen primer @0.30 Ltr/sqm evenly over plastered suface, complete all as specified and directed.
M&L for applyng a tack coat of hot blown bitumen 85/25 grade @1.2 kg per Sqm including cleaning surface, complete all as specified and directed.
M&L for polymeric water proofing membrane consisting of 90-100 micron thick central core of HMHDPE film with standard weight not less than 3 Kg/Sqm, laid with 100 mm side lap/end lap on prepared surface as per manufacturer's instructions and under strict supervision of manufacturer's technical representative, complete all as specified and directed.
M & L 40mm thick brick tiles laid on cement mortar mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement over 20 mm thk screed bed of cement mortar in CM 1:4 with WPC @ 3% by weight of cement, complete all as specified and directed. (Note :- WPC shall be measured and paid separatly)
Supply only ISI marked approved integral water proofing compound, complete all as specified and directed.
Closing bolt holes etc. with metal putty in old corrugated steel sheets or Aluminium sheeting by sealing with one bitumen and one curved GI washer on either side and 6mm self tapping screw, incl removing old tapping screw and all set in stiff white lead, complete all as specified and directed.
M&L Bitumastic gola, with 80/25 bitumen and coarse sand mixture 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surface, complete all as specified and directed.
Taking down & refixing Shutters in same opening of any description exc 1 sq. m and n exc 2 sq. m each after easing and adjusting etc, complete all as specified and directed.
Taking down of chowkat with shutter without taking off shutters from the frame not exceeding 1.50 Sqm each and removal from site, complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site, complete all as specified and directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel Sqm tube & fixed in position as per manufacturer's instruction, complete all as specified and directed.
S&F factory made solid PVC moulded door shutter, 28 to 30 mm thick (stile) with 2, 4 or 6 raised panels designed with 2 mm thick moulded PVC sheet on the front face and 2 mm plain coloured PVC sheet on back face, supplied and fixed to frame at site as per specification and drawing with wood free EPS core, complete all as specified and directed.
S & F pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc, complete all as specified and directed.
M & L for PCC 1:3:6 type C-0 using 12.5mm graded stone aggregate as in filling back side of pressed steel door/window frames, complete all as specified and directed.
S&F glazed/wire gauged/skeleton shutter 35 mm thick out of (well kiln seasoned) 2nd class hard wood (hollock) the size of rails and style as per IS chemically pressure treated in factory gainst termite infestation prepared to receive wire gauge (without sash bars) edges of frame chamfered or rounded fitted with cut and mitered beads, complete all as specified and directed. (Note : Wire gauge/glazing to be measured and paid separately).
S&F of 40 mm thick flush shutters, solid core construction, with particle board core and ply wood face panels, commercial type on both sides, complete all as specified and directed.
M&L for preparation of new wood base surfaces applying one coat of pink primer and over it two coats of synthetic enamel paint (ordinary tint) of any description, over 10 cm in width or girth, not otherwise described, complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint (ordinary tint) of any description, over 10 cm in width or girth, not otherwise described over one coat of red oxide primer, complete all as specified and directed.
S&F for 100mm long mild steel butt hinges, heavy weight cold rolled mild steel and fixed, complete all as specified and directed.
S&FAluminium anodised barrel tower bolt of extruded section 150mm long, complete all as specified and directed.
S&F for 200 mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed.
S&F extruded aluminium alloy handle fabricated type anodised 100 mm long, complete all as specified and directed.
S&F 150 mm long aluminium anodised handles, cast type, complete all as specified and directed.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and directed.
S&F mild steel 300 mm ordinary rat tail rod pattern springs including roller & roller plate, complete all as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 140mm, complete all as specified and directed.
S&F Aluminium powder coated anodised frame for ventilator incl joining cleats & rubber beading for fixing for glass, wire mesh etc, complete all as specified and directed.
Supply and Fixing sheet glass 3 mm thick frosted ordinary quality and glazing with oil putty or glazing pins/spring clips with metal frames, complete all as specified and directed.
S&F galvanized mild steel wire cloth with 0.56 mm nominal dia of wire and average width of aperture 1.18 mm, complete all as specified and directed.
Dismantling water storage tank of any description of capacity exc. 250 ltr but n.exc. 500 ltr, complete all as specified and directed.
S&F 500 ltr capacity rotational moulded polyethylene water storage tanks with all fittings of GI (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and directed.
S&F in repair 20 mm dia float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 15mm - 142 gms / 20mm -210 gms / 25mm - 455 gms /40 mm - 690 gms / 50 mm - 1240 gms), complete all as specified and directed.
S&F in repairs gun metal globe or gate valves of 20mm dia pipes with iron wheel head screwed both ends for iron pipe or for unions, fixed in repairs etc, complete all as specified and as directed
M&L for PCC (1:4:8) type D-2 (using 40mm graded stone agg) 75 mm thick as in sub base, sub floor etc, complete all as specified and directed.
S&F stainless steel tubular curtain rods, 25 mm dia, with fixing brackets and one pair of decorative end caps etc, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan socket or power) complete fittings such as switches, sockets, ceiling rose, pendents, regulators etc complete as ordered and removing retrieved materials and making good the disturbed surface of wall, floors, ceiling etc, complete all as specified and directed.
Material and labour for point wiring, using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with FRLSH PVC insulated and unsheathed stranded copper conductor cable 1.5 sqmm single core conforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primer with top cover 3 mm thick bakelight laminated sheet with brass screws and Cup washer with all assessories including FRLSH PVC insulated and unsheathed stranded copper conductor cable 1.5 sqmm single core in green colour as earth wire connected to earth dolly, complete all as specified and directed for the following: - (a) One light/fan/exhaust fan point controlled by 1 No. one way 5/6 Amp switch.
(b) One 2pin/3pin socket outlet 5 amps on independent board with cable 1.5 sqmm.
(c) One 2 pin/3 pin 5 Amps socket outlet on same board with other switches.
Material and labour for point wiring, using approved colour coding (Phase-red, Neutral-black, Earth-green) complete for one socket outlet 15 Amp on independent board with FRLSH PVC insulated and unsheathed stranded copper conductor cable 2.5 sqmm single core conforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537 (part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primer with top cover 3 mm thick bakelight laminated sheet with brass screws and Cup washer with all assessories including FRLSH PVC insulated and unsheathed stranded copper conductor cable 2.5 sqmm single core in green colour as earth wire connected to earth dolly, complete all as specified and directed.
Material and Labour for switch piano flush type 5A, SP one way, 240 Volts AC, complete all as specified and directed.
Material and Labour for socket 5 pin 5 Amps flush type, 240 volts AC, complete all as specified and directed.
M & L for switch piano flush type single pole one way 15 Amps, 240 volts AC, complete all as specified and directed.
Material and Labour for socket outlet 6 pin 15/5 Amps flush type, 240 volts AC, complete all as specified and directed.
Material and Labour for ceiling rose 3 terminals ISI marked, 240 Volts AC, complete all as specifed and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type aluminium die cast housing with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC die cast aluminium housing with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as spedified and directed.
Supply and fixing in replacement exhaust fan, steel body AC single phase 230 V of size 300 MM sweep with blades and frame and louvers, making good of disturbed surface, complete including submitting the old one to MES store, complete all as specified and directed.
Supply and fixing in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor including submit the old one to MES store, complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole & neutral and current carrying capacity 6 to 32 AMP in the MCB DB complete with connection testing and commissioning, complete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 AMP, in the MCB DB complete with connection testing and commissioning, complete all as specified and directed.
S & F MCB DB SPN 4 Way with 100 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing including taking down old u/s MCB DB SPN 4 Way, complete all as specified and directed.
S & F MCB DB SPN 8 Way with 100 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing including taking down old u/s MCB DB SPN 8 Way, complete all as specified and directed.
S & F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with two single core FRLSH PVC insulated and unsheathed stranded copper conductor cable 4 sqmm as current carrying conductor and neutral cable, voltage rating 1100 volt, ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with standard accessories along with one run of FRLSH PVC green colour insulated, unsheathed, stranded copper conductor cable of size 4 sqmm as earth cable, complete all as specified and directed. Note: Two run of single core FRLSH PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
S & F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with two single core FRLSH PVC insulated and unsheathed stranded copper conductor cable 6 sqmm as current carrying conductor and neutral cable, voltage rating 1100 volt, ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with standard accessories along with one run of FRLSH PVC green colour insulated, unsheathed, stranded copper conductor cable of size 6 sqmm as earth cable, complete all as specified and directed. Note: Two run of single core FRLSH PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete including fixing on GI tubing, complete all as specified and directed. Note: GI tubing shall be measured and paid under respective item of Schedule 'A'.
Supply and fixing LED flood light fitting 120 watt, 230 V AC, outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistance complete with driver and lamp including all fixing arrangements on metalic sheets, complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed.
S&F sheet metal enclosure with a two pin and earth plug and socket complete including one single pole MCB 20 A 10 KA C series flush into walls and making good disturbed surfaces, complete all as specified and directed.
S&F sheet metal enclosure 2 way single door IP-43 with complete including one single pole neutral MCB 6A 10 KA C series flush into walls and making good disturbe surfaces, complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections 4 sqmm multi stranded, complete all as specified and directed.
M&L for GI tubing medium grade 15 mm bore, fixed on walls/poles, with all necessary fitting as required at site, complete all as specified and directed.
M&L for GI tubing medium grade 40 mm fixing in upright position of size 1.0/1.2 mtr embedded in PCC foundation for fixing of post top lantern, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded mechanically crushed stone aggregate) for mass filling in coping of pole including form work, complete all as specified and directed.
M & L for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized earth lead wire 4.0 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed. NOTE: (i) The unit rate includes earth wire and protection pipe up to (maximum 7.5 metre from earth plate) earth point/test point.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc, complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm
Removing of excavated material n, exc 50 mtr away and depositing where directed at a level n, exc 1.5 mtr above the starting point complete all as directed.
Supplying and laying pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), laid flat perpendicular to the cable adjoining each other as in protection to UG cables, complete all as specified and directed.
M&L for fine sand free from sharp material as in filling in trenches for cable protection incl necessary punning and consolidation as reqd, complete all as specified and directed. (Note: Depth of sand shall be measured after punning).
M&L for PCC 1:4:8 type D-2 using 40mm graded mechanically crushed stone aggregate for mass filling in pole pit and foundation etc, complete all as specified and directed.
Supply, Laying, jointing and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable, heavy duty, with 25 Sqmm, 4 core aluminium conductor, 1100 Volts grade, complete all as specified and directed.
Supply, fixing & jointing 40 mm bore galvanised iron water tubes 'light grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed to poles/walls or laid under roads/drain/nallah/floor etc including flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
ARTI ENTERPRISES
Bikarma Enterprise
Anjali Constructions
G S CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .