| 1 | L1₹4.9 CrAccepted-AOC 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | ₹4.9 Cr Quoted ₹5.0 Cr | L1 | Accepted-AOC Being Lowest bid |
| 2 | L2₹5.3 Cr+₹32.8 L (6.61%)Rejected-Finance D 89 SHASTRI NAGAR MEERUT 250004 | MEERUT | UTTAR PRADESH | 250004 | ₹5.3 Cr+₹32.8 L (6.61%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹5.3 Cr+₹33.9 L (6.84%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹5.3 Cr+₹33.9 L (6.84%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹5.5 Cr+₹49.3 L (9.93%)Rejected-Finance 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | ₹5.5 Cr+₹49.3 L (9.93%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹5.7 Cr+₹72.4 L (14.6%)Rejected-Finance | ₹5.7 Cr+₹72.4 L (14.6%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹6.4 Cr
EMD Value
₹6.4 L
Closing Date
6 Jan 2023, 6:00 pmClosed
CHIEF ENGINEER BAREILLY ZONE
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt
ADDN ALTN CUM SPECIAL REPAIR CERTAIN MD ACCN AT MEERUT
2022_MES_562257_1
CEBZ/MRT/T-16 OF 2022-2023
Open Tender
Civil Works
Item Rate
365 days
MEERUT
AS PER NIT
8 documents required · 8 mandatory
₹3,000
Yes
GE NORTH MEERUT
₹6.4 L
Yes
4 Feb 2023
11 Nov 2022
14 Jan 2023
11 Nov 2022
6 Jan 2023
23 Dec 2022
Amount
SCHEDULE 'A' PART-I (B/R WORK)
Demolition of brick work in cement mortar including all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles incl rubbish off the premises complete all as specified and as directed.
M&L for brick work with old size fly ash bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as specified and directed.
M&L for brick work with old size sub class 'B' bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) but except bricks complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floor and paving n. exc 15 cm thickness (below or above ground level) incl rubbish off the premises complete all as specified and as directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 25 mm thick plain cement concrete 1:2:4 type B-1 (20 mm graded stone aggregate) as in sub-base of floors, complete all as specified and directed.
M&L for Non-skid coloured ceramic tiles 7 to 8 mm thick square/ rectangular), area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set & jointed in net cement slurry and pointed in white or coloured cement to match laid over with and including 15mm thick screed bed in CM 1:6 complete as specified and directed.
M&L for Non-skid coloured ceramic tiles 7 to 8 mm thick square/ rectangular), area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set & jointed in net cement slurry and pointed in white or coloured cement to match laid over with and including 15mm thick screed bed in CM 1:6 complete as specified and directed.
All as per item No 09 above but as in skirting over with and including 10 mm thick screed bed in CM 1:4 complete as specified and directed.
M&L for glazed ceramic coloured tiles of size 450X300X7mm on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, over with and including rendering 10mm thick in cement mortar (1:4) , complete all as specified and directed.
Dismantling stone slab/ tiles of any description or any thickness laid, bedded and pointed in any mortar on roof including rubbish off the premises complete all as specified and directed.
M&L for 16-18 mm thick black granite stone slab machine cut, as in cooking platform, windows cills and the like laid over and including 15 mm thick screed bed in cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement and with admixture or pigment to match the shade of granite stone including grinding and polishing complete all as specified & directed.
M&L for 16-18 mm thick black granite stone slab machine cut, as in vertical surface like skirting/dado, jambs, pillars fixed over and including 10mm thick rendering or backing screed in cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement and with admixture or pigment to match the shade of granite stone including grinding and polishing complete all as specified & directed.
M&L for Machine cut pre-polished kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and over and including 15mm thick screed bedding in CM 1:6 complete all as specified and directed.
M&L for Machine cut pre-polished Kota stone slab 20-25mm thick, factory made bull nosed exposed edges as in riser of steps, skirting, dado and pillar over including rubbing and polishing complete with and including rendering 10mm thick in cement mortar 1:4 , complete all as specified and directed.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) n.exc 1.50 sqm each and removing from site including making good disturbed portions of wall with new or old bricks, lintel, cills etc in CM 1:4 complete all as specified and directed.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) exc 1.50 sqm but n.exc 4.0 sqm each and removing from site including making good disturbed portions of wall with new or old bricks, lintel, cills etc in CM 1:4 complete all as specified and directed.
S&F for factory made double extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fasts/ lugs/SS dash fasteners of required dia and length, complete all as specified & directed. Note:- (i) (MS hold fasts/ lugs or SS dash fasteners shall deem to be included in quoted rate) (ii) For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable (iii) Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be admissible.
S&F for factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length, complete all as specified & directed. Note:- (i) (MS hold fasts/ lugs or SS dash fasteners shall deem to be included in quoted rate) (ii) For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable (iii) Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be admissible.
S & F for 30mm thick factory made single extruded WPC (Wood Polymer Composite) solid Moulded WPC door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
S&F factory made solid wire gauzed PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing wire gauzed i.e. panel will be of wire gauze in lieu of single side prelam PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly → supplied and fitted to chowkats complete all as specified and directed.
S&F for built in steel cup board with pressed steel frame of size 75 mmx 45 mmx 1.25 mm thick with pressed steel shutter 1 mm thick Godraj pattern fixed to masonary wall by hold fast out of 25x3mm flat iron including MS hanging rod of 10 mm dia with bracket fixed on inner side of one leaf of shutter and on other leaf provision of MS peg set of 3 pegs, locking arrangement including spary painting with two coats of synthetic enamel paint over a coat of red oxide primer to all around on steel surface of frame and shutter and making good distrubed portion in CM 1:3 or PCC 1:2:4, type B0 using 12.5 mm graded stone aggregate complete all as specfied and directed.
S&F powder coated anodised aluminium windows sliding type (3 shutter type) with sash bars, aluminium sections weighing 0.55 Kg/mtr (minium) incl stainless steel mosquito proofing wire mesh fixed with , clips, frame , necessary joining cleats, glazing clips, neoprene rubber gasket with aluminium beading, suitable anodized aluminium fittings such as hinges , handles including powder coated aluminium frame one or more rebates, grill etc and S&F 5.5 mm thick black sheet glass, complete all as specified and directed.
S&F 18/19 mm thick WPC (Wood Polymer Composite) solid board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with SS screws to WPC frame work in cupboards/kitchen cabinets rebated or flat edged, fancy handles, magnetic lock & brass knob as per requirement, complete all as specified and directed.
S&F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for preparation of newly or previously untreated steel surfaces of any description not otherwise described over exceeding 10cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide complete all as specified and directed.
M&L stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or stainless steel wire staples complete all as specified and directed.
S&F 30 mm flap (when open) continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specified and directed.
S&F 125 mm size aluminium alloy handles, cast type anodized complete all specified and as directed.
S&F 150 mm size aluminium alloy handles, cast type anodized complete all specified and as directed.
S&F aluminium anodized barrel tower bolts 150 mm long, extruded section, complete all specified and as directed.
S&F 300 mm long aluminium alloy anodised sliding door bolt 300 mm long, bolt type with bright bolt not less than 12mm dia with and including a minimum of 06 bolts with nuts (04 on bolt plate and 02 on staple plate), complete all as specified and directed.
S&F butt hinges 100mm size, heavy weight, cold rolled mild steel and fixed complete all as specified and directed.
S&F aluminium anodized barrel tower bolts 200 mm long, extruded section, complete all specified and as directed.
S&F mild steel plain black sheet 1.00mm thick in hearths; covering to door shut ters; covering to door chowkats frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. complete all as specified and directed.
S&F mild steel 150mm size helical door spring including roller and roller plate fixed with screws to wooden chowkat or welded to steel frame, complete complete all specified and as directed.
M&L for 30 mm thick stone dressed true and square, in one length not less than 60cm and n. exc 120cm in copings, window cills, chajjas, sunshades, etc., punched dressed on exposed faces and self faced on the embedded unexposed beds and joints; exposed edges rounded or chamfered as directed, set, jointed and pointed in cement mortar 1:4, complete all as specified and directed.
Taking down cement plaster of any description, thickness on brick, stone, concrete surfaces including racking out joints, hacking for key, scrubbing down with water, removal of rubbish and cleaning, etc complete as directed and specified.
M&L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and fair, complete all as specified and directed.
M&L for 15 mm thick rendering using ready mix plaster bags in cement mortar 1:4 with using water proofing compound @ 3% by weight of cement or as per manufacturer’s instructionson fair faces of brick work or concrete external wall surfaces, finished even & smooth without using extra cement, complete all as specified and directed. (Note:- (i) Water Proofing compound shall be measured and paid seprately under respective item (ii) Contractor will procure and deposit ready mix bags for 100% quantity as per contract to Engr-in-Charge within 15 days of Work Order)
Supply only Water Proofing compound ISI marked, complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortar 1:3 as on concrete surfaces on ceiling, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of surfaces after complete removal of existing treatment by mechanical manner, complete all as specified and directed .
M&L for applying one coat of primer using roller, complete all as specified and directed.
M&L for applying two coat of oil bound distemper using roller, complete all as specified and directed.
M&L for preparing newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for preparing old plastered surfaces and applying one coat of white wash on ceiling complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) incl removing rubbish off the premises complete all as specified and as directed.
Use & waste for form work to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports, overhangs, etc. for rough finished surfaces of concrete complete all as specified and directed.
M & L for RCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as spd and directed.
M & L for precast reinforced cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles set in cement mortar 1:6 incl all necessary form work and finishing exposed concrete surface complete all as spd and directed.
Cutting chases, pinning in. brick work and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth complete all as spd and directed.
S&F TMT reinforcement bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F TMT reinforcement bars 6-8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections complete all as specified and directed.
S&F 20 mm dia CPVC pipes SDR 11 & with plain CPVC SDR 11 fittings, fixed to walls and ceilings or laid in floors, complete all as specified and directed.
S&F 25 mm dia CPVC pipes SDR 11 & with plain CPVC SDR 11 fittings, fixed to walls and ceilings or laid in floors, complete all as specified and directed.
Dismantling water tank of capacity exc 250 ltrs but not exc. 500 Ltrs complete all as specified and directed.
S&F rotational moulded polyethene water storage tank (White Color and Triple Layer ) ( cylinderical verticle with closed top) hoisted and fixed in position all as specified in SSR Part-I. (Cap 500 ltrs capacity). complete all as specified and directed.
S&F 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms) complete all as specified and directed.
S&F in repairs 15 mm dia bib tap chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, 140 mm over all length of cover plate, complete all as specified and directed.
S&F in repair 15 mm dia Angle Valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair vitreous china squatting pan of orrissa pattern long pan size 580 x 440 mm white with "P"or "S" trap size 100 mm dia front or back inlet and integral foot rest any pattern (excluding flushing cistern and flush pipe) including provn of lime concrete bedding (1:2:5), minimum 150mm all round and finish just below level of rim of pan complete all as specified and directed.
S&F Wash basins, Vitreous China (flat back or angle back type) including pedestal size 550x400mm, including fixing acessories like brackets, rig bolts, 32 mm dia waste coupling and cutting for and pinning in ends of brackets or erecting stand but excluding of fixing of supply and waste pipe complete all as specifed and directed.
S&F PVC low level flushing cistern 10 litre, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including flushing pipe & fixtures such as rawl plugs, complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) floor trap plain with grating jointing with solvent cement, complete all as specified and directed.
S&F in repair 125/110 mm bore PVC (SWR) gully trap plain with grating jointing with solvent cement, complete all as specified and directed.
S&F 15 mm dia PVC connection with PTMT nuts of length 450 mm complete all as specified and directed.
S&F stainless steel kitchen or laboratory sink of 1.00 mm thickness, overall size 495x420mm with bowl size 410x330x160 mm, including waste pipe & SS coupling, washers, including bedding in cement mortar on to dwarf wall or fixing cantilever brackets and connecting union to pipe etc complete all as specified and as directed.
S&F in repair 125mm size brass CP shower rose with or without swivel joints complete all as specified and as directed.
S&F in repair CP brass Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed.
S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed.
S&F in repair PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to wall and floor with necessary fitting as in waste and rain water pipe complete all as specified and as directed.
S&F in repair PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints fixed to wall and floor with necessary fitting as in waste and rain water pipe complete all as specified and as directed.
S&F 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S&F 75 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F 110 mm bore PVC (SWR) junction single, (single T), equal or unequal complete all as specified and directed.
S&F 110 mm bore PVC (SWR) 'S' trap complete all as specified and directed.
S&F Stack clamps made out of 50 mm x 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed.
S&F 15 mm dia gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F 20 mm dia gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed.
S&F in repairs brass chromium plated central hole wall basin mixer fancy type with or without lettered, 15mm for mixing hot & cold water with long screwd shanks and fly nut capstan head or unions and screwed to walls complete all as specified and as directed. Make:- Cera Cat Part No F-2002461, Pearl Cat Part No ARI-013, Hindware Cat Part No- F-74 0009
S&F 15mm dia chromium plated fancy type wall mixer with over head shower for mixing hot & cold water screwed, fixing and connection to pipes complete all as specified and as directed. Make:- Cera Cat Part No F-1017401, Pearl Cat Part No ARI-015, Hindware Cat Part No- F-74 0022
S&F 15mm dia chromium plated fancy type sink mixer with swinging spout (wall mounted model) fixing and connection to pipes complete all as specified and as directed. Make:- Cera Cat Part No F 2004501, Pearl Cat Part No ARI-011, Hindware Cat Part No- F 330023
S&F sheet glass shelf assembly consisting of not less than 5.5 mm thick sheet glass shelf 12 cm wide with CP bracket gaurd and railling 60 cm long complete all as specified and directed.
S&F fancy type glass corner 250mmx250mm of 6 to 7mm thick toughned glass with CP railing fixed with fancy type screws complete all as specified and directed.
S&F in repair chromium plated brass tubular towel rail 20 mm dia, 'D' type 60cm long between flanges complete all as specified and directed.
S&F Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type waste pipes of 32 mm dia suitable for wash basin/sinks complete all as specified and directed.
Supply & fix in repair 50 mm wide rubber beading for doors of required size complete all as specified & directed.
S&F in repair stainless steel plate rack of size 750mm x 600mm made out of 0.80 mm thick sheet including taking out existing wooden plate rack complete all as specified and as direcetd.
Supply & fix in repair 25 mm dia stainless steel decorated curtain rod of 0.80 mm thickness with brackets and rings complete all as specified & directed.
M&L for providing & injecting chemical emulsion for post construction ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in a portion with cement mortar (1:2) to match the existing apron complete all as specified and as directed.
M&L for post construction anti-termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor, complete all as specified and as directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
S&F for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and ountersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for dubbing out average 20 mm thick on irregular faces of wall and on ceiling in cement mortar 1:4, complete all as specified and directed.
Material & labour for sunken slab treatment comprising of the following :- (a) Taking out/ down old existing sunken slab treatment and cleaning the old RCC surfaces of sunken slab including removal of the rubbish from the site of work to a distance n.exc. 250mm compete all as specified and directed. (b) Material & labour for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) over cleaned sunken slab surfaces. (c) Material & labour for applying bituminous priming coat/tack coat over PCC surfaces @ 0.30 Kg per square metre of surfaces. (d) Material & labour for applying bitumin grade 85/25 over priming coat @ 1.20 Kg per Square metre. (e) Material & labour for 25mm thick plastering in CM 1:4 using water proofing compound (WPC) @ 200 ml per bag of cement. on wall of sunken floor (f) Material & labour for suitable thickness of PCC 1:5:10 type E-2 (using 40mm graded broken brick aggregate) for filling in the sunken portion of slab up to its floor level. (g) Supply & fix of 32mm dia GI pipe medium grade, 450m long (for draining out the water) complete all as specified and as directed.
M & L for cutting of bushes small trees ( Peepal small plants etc) trunks shrubs of any dia and girth from roof projection, chajjas, wall junction parapet etc at any height by necessary demoliton of brick work etc if requried and making good distrubed surfaces to match with existing finihes with and incl material and labour in CM 1:4 mixed with WPC /PCC 1:3:6 type B0 (12.5 mm graded stone aggregate) / Brick work in CM 1:4 as required at site and complete all as specified and as directed.
Taking down old existing water proofing treatment from the top of RCC/Arch slab, incl taking down existing PCC padding or plaster and hacking the top of RCC slab, cleaning with water and disposal of rubbish complete all as specified and directed.
M&L for 50 mm thick (average thickness) PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in padding on roof finished the surface even and fair without using extra cement complete all as specified and directed.
M&L for 10 mm thick plaster on roofs in cement mortar 1:4 mixed with using water proofing liquid @ 200 ml per 50 kg of bag of cement including finishing the surface even and smooth without using extra cement for laying water proofing treatment, complete all as specified and directed. Note:- Water proofing liquid shall be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed.
Surface Preparation: The surface to receive the treatment shall be thoroughly free of laitance, scales, oil or any other loose material. It should be made free of any sharp objects. Cleaning of PCC shall be done with wire brushing to attain smooth levelled surface. Cracks shall be rectified, filled using dual shrinkage compensated Repair Mortar and dried for 72 hours before laying the liquid applied membrane. (a) Grout: Providing Chemical injection treatment in the form of pressure grouting to the construction joint and cracked portion at 1m c/c by injecting cement slurry mixed with dual shrinkage compensated cementitious grout Injection grout additive, in the required consistency through the pre fixed PVC nozzles in the 18 mm dia holes, fixing of PVC nozzles with instant setting cement. Angle fillets/Coving: Providing and making of fillet, 50mm x 50mm on sharp corner of terrace with cement sand polymer mortar (add “multipurpose mortar”, 10% by weightofcement). First apply the bonding coat of Multi-Purpose Polymer 5-10% diluted in water and add to cement slurry. Apply the bonding slurry and apply the polymer mortar over the sharp edges. Note: Grouting will be done when and where ever required.
(b) Treatment of pipe entry points: Preparing the inside surface of core and PVC /MS Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Packing the gap using free flowable non shrink cement polymer based grout up to the surface of the bore while the bonding agent is in tacky state. the periphery of PVC pipe should be sealed with Hybrid PU Sealant or dual shrinkage compensated Micro concrete Note: Will be done when and where ever required (c ) Application of Asian Paints two component Epoxy Primer (Resin & Hardener) on the cleaned surface for bonding of Polyurethane with the existing concrete surface. 33 % water dilution is recommended with the pure mixed primer. The primer mixing ratio will be 1:3(Resin:Hardner) Supplying, providing and applying waterproofing treatment to Podium area with single component highly elastomeric seamless cold applied modified PU coating complete as per manufacturer’s specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of 1mm. The coating shall have a dual combination of 280% elongation. Material coverage 1.2kg /sq.mt. (Note: Contractor will deposit 100% CA quantity to the Engr-in-Charge within 15 days after placing work order No 1.”
M&L repair to overhang portion of chajja, facia, dropwall etc. for continuous work by providing PCC(1:2:4) Type B-0 and finished with CM(1:3) after taking down of damaged portion of RCC work by maintaining same level and finished the surface to match with the existing surface by providing same finish complete all as specified and directed. (Height of work to be considered upto 3.5m and upto 7.00 mtr from FFL of Ground Floor.) (Note : Wherever reinforcement is required to be provided will be paid separately under relevant item and contractor have to inform the department one day in advance after binding of reinforcement for measurement otherwise no payment will be considered on this account).
M&L PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in coping, bed blocks and like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for repairing existing RCC structure work by guniting to damaged edges bottom of beams, chajja, facia, slab 40 mm to 60 mm thick and part of RCC members in cement mortar 1:3 and depositing material/mortar with spray gun under a pressure of 20 to 30 N/Sqcm including scaffolding and supplying wire mesh 50mmx50mm of 2 mm dia including cutting, welding and placing in position complete all as specified and directed.
M&L for applying 3 mm thick (averaging) wall care putty for making smooth surface, complete all as specified and directed.
M&L for providing plain cement concrete 1:2:4 type B-2, (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
S&F pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with hot dip galvanized self tapping screws, neoprene and EPDM washers, fixed as per manufacturer's instructions complete all as pecified and directed .
S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc including notching, drilling, fittings, riveting and / or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing fittings angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing conf to Fe-410-w (Gde-E -250) quality A complete all as specified and directed.
M&L preparation of newly plastered or unplastered surface and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 sqm using rolled to painting, complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for drain etc incl rubbish off the premises complete all as specified and as directed.
PATH/HARD-STANDING AND AREA DRAINAGE
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. nexc10 sq m on plan and getting out soft/loose soil complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out, returning, filling and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm thick watering and removing surplus soil to a distance not exc. 50 m and making good surface as in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Removing excavated material n exc. 50m in soil and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base unde floor/paving, complete all as specified and directed.
M&L for river dry sand cushioning n.exc 25 mm thick for inter locking tiles/ filling under floors including watering and consolidation complete all as specified and directed.
M&L for cement concrete coloured interlocking paver blocks of 60mm thickness, M-35 Grade, factory made with casting in rubber moulds & compacting on a vibro table assembly and cured in curing tank for atleast 14 days and then air dried before use, paver block confirming to IS 15658 -2006, approved design, shape, size and colour of top layer, complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) solid blocks exceeding 10 cm in width and shape as directed, set and jointed in cement mortar 1:6, complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) in surface channel/drains etc complete all as specified and directed .
SEWAGE DISPOSAL
M & L for providing plain cement concrete type D-2, 1:4:8, (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for concrete (1:4:8 type D2) bed to drain pipes for 150 mm including packing under, and haunching against the sides of pipes after they are laid and tested including all necessary shuttering and supports to concrete and for laying beds to falls.complete all as specified and directed.
M&L for concrete (1:4:8 type D2) bed to drain pipes for 200 mm including packing under, and haunching against the sides of pipes after they are laid and tested including all necessary shuttering and supports to concrete and for laying beds to falls.complete all as specified and directed.
S&F 150mm dia salt glazed stoneware drain pipes, laid in trenches and jointed with collars in cement and sand mortar 1:1, including demolition & breaking up drain pipe and removal upto 3.0 KM outside MD land, complete all as specified and directed. (Note:-Excavation & earth work shall be measured separately)
S&F 200mm dia salt glazed stoneware drain pipes, laid in trenches and jointed with collars in cement and sand mortar 1:1, including demolition & breaking up drain pipe and removal upto 3.0 KM outside MD land, complete all as specified and directed. (Note:-Excavation & earth work shall be measured & paid separately)
Extra for forming fair finished drain or channel, 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred, stopped ends, complete all as specified and directed.
M&L for preparing newly plastered surfaces and applying three coats of white wash on wall surfaces, complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150 mm dia pipe complete all as specified and directed.
SCHEDULE 'A' PART-II (E/M WORK)
Taking down carefully copper/aluminium point wiring light, fan, socket or power point complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings, bell push, bell buzzer etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces complete all as specified and directed.
Taking down unserviceable main switch, DBs with MCBs any size and capacity including making good disturbed surface of wall complete all as specified and directed.
Taking down energy meter by disconnecting electric connection of any type, any capacity, note down meter number, qtr No and reading of meter for each qtr while taking down energy meter and depositing to MES store yard for keeping in safe custody complete all as specified and directed.
Taking down and disconnecting ceiling fan of any size, sealing cable end, dismentalling blades, make one set of three blades and depositing to MES store yard for keeping in safe custody complete all as specified and directed.
M&L for point wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed steel terminal box for mounting fittings i.e, normal piano switch / sockets incl cover plate with frame and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: -
One light point / bulb/security light point controlled by one, one way switch 5/6 Amperes single pole.
One fan point controlled by one, one way switch 5/6 Amps.
One 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch.
One 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch.
One Bell point controlled by one, one way switch 5/6 Amps.
One two way point controlled by two, two way switches 5/6 Amps.
M&L for power point wiring of copper cable FRLS grade,multi stranded 2.5 Sqmm size for 15/16 Amps socket outlet on independent board with 2.5 Sqmm size of copper cable FRLS-H grade,multi stranded earth conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed steel terminal box for mounting fittings i.e, normal piano switch / sockets incl cover plate with frame and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 2.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed.
Supply and fixing switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed.
Supply & fixing switch piano flush type, 05 / 06 Amps single pole, two way 240 volts complete all as specified & directed.
Supply and fixing socket outlet 5 pin, 05 / 06 Amps flush type 240 volts complete all as specified & directed.
Supply & fixing of socket outlet 3 pin, 05 / 06 Amps and 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified & directed .
Supply and fix in switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed.
Supply and fixing bell push flush type , 5 amps , 240 volts complete all as specified and directed.
Supply and fixing ding dong bell,AC , 230 volts ,Single pole complete all as specified and directed.
Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate complete all as specified and directed.
Supply and fixing decorative wall mounted LED tube light fitting 20 watt, PF>0.9, LPW>100 and all specifications as per IS, with polycarbonate housing and integrated electronic driver with all accessories and fixing material complete all as specified and directed. Make- Havells, Cat Part- LUMILINEPLUSBS20WLED 865SPCSS/ Crompton Cat Part - LCTLN-20-CDL/ Wipro Model- Garnet /Bajaj Cat Part-BCLSB20WWH
Supply and fixing decorative LED tube light fitting 10 watt, PF>0.9, LPW >100 and all specifications as per IS, wall mounted with extruded polycarbonate ,integrated lamp & driver with opal diffuser and decorative end plates complete with all accessories and fixing material complete all as specified and directed. Make- Havells, Cat part- LUMILINEPLUSBS10WLED 865SPCSS/ Crompton Cat part - LCTLN-10-CDL/ Wipro model-Garnet/ Bajaj Cat Part-BCLSB10WWH
Supply and fix decorative wall light fixture made up of polycarbonate body with and including 10 watt led lamp complete all as specified and directed.
Supply and fix LED lamp 9/10 watt suitable for batten/angular holder, complete all as specified and directed.
S&F 35/36 Watt LED security light fitting PF>0.9, LPW >100 and all specifications as per IS, energy saving & environmental friendly long life luminaire with high power LEDs as light source and electronic driver with die cast aluminium housing IP 66 protection with lens embedded PC cover including security light brackets made of 32 mm dia GI pipe medium grade upto 0.9 mtr long bend to shape at 100-120 degree including flat iron clamps and suitable nuts and bolts grouted in wall including all material required for fitting complete all as specified and directed. Make- Havells, Cat Ref- ENDURAPEARLLSL35W LED757SASYTOPCMP/ Crompton- Cat Ref TRP-400-35-57-SL-LM-NSR/ C&S, Cat Ref INDUS-E/35W/ Bajaj Cat part No.ENXTP35LWHPOPCSD
Supply & fixing of ceiling rose, 3 terminal , PVC/polycarbonate isolated body complete all as specified & directed.
M&L for sub main wiring alongwith earthwire for two single core 6 sqmm size sub main wiring with one single core 6 sqmm size earthwire drawn into and including one run 25 mm or higher dia PVC conduit fixed concealed. PVC insulated PVC unsheathed multi-stranded copper conductor cable FRLS in and including PVC conduit medium grade ISI marked, fixed concealed of size as mentioned below complete with all conduit all accessories / fittings as required at site and connecting of earthwire to common earth dolly complete all as specified and directed. Note :- Three run of 6 sqmm copper cable and one run of conduit shall be measured as one unit.
Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as specified and directed.
Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 4 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as specified and directed.
Supply and fixing MCB, SP, AC, 240 volts "C" series capacity of 06 to 32 Amps, 10kA and making connections complete all as specified & directed.
Supply & fixing MCB, DP (Double Pole), AC, 240 volts, B series capacity 32 Amps to 40 Amps 10kA and making connections complete all as specified & directed.
Supply and fix MCCB 4 pole, 100 Amps 25 kA with fixed overload and fixed short circuit setting Ics= 100% Icu complete all as specified & directed.
Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with the inbuilt provison for fixing of 1 No MCCB and 12 Nos MCB's inside of DB, with metal door and flush to wall including grouting and cutting in existing wall and making good disturbed surface with two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed.
Material and labour for earthing with galvanised steel earth plate electrided 600 X 600 X 6 mm thick buried in ground (earth pit not less than 2.25 mtr depth below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth lead wire 4.0 mm dia by means of bolts nuts chek nuts and washers of galvanized iron or steel earth lead wire protected by and including 15 mm dia GI pipe medium grade pipe for protection and 20 mm dia GI pipe (medium grade) for watering and connected to control switch as directed including necessary earth work as in soft/loose soil, concrete pit in PCC (1:3:6) type c1, pre cast RCC 1:1:5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 100 mm CC both way and 2 No, lifting handle made of 12mm dia TMT bar and set in cement mortor (1:4), funnel wire nesh, char-coal or coke and salt in alternate layer, testing etc complete all as specifide in electrical plate No. 3 of SSR Pt-1 all as specified and directed. Note:- (i) If the desired earth resistance is not found within permissible limit, shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 Sqmm and 15mm dia GI pipe medium grade upto 7.5 m is included in the rate quoted for this item.
Supply and fixing Exhaust fan metal body with sturdy steel bird cage,double ball bearing and heavy duty motor copper winding, metal blades and fixing accessories 230 Volt and 300 mm sweep with and including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring complete all as specified and directed. Make- Usha- Model- Aeroclean pro , Havells- Model- Ventil Air DSP, Crompton- Model-Transair/ Bajaj Model-FRESHEE 300MM
Supply and fixing ceiling fan with blades, down rod, electronic regulator and accessories, 230 volts, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE with brushless direct current motor (BLDC) including connection with flat 3 core copper wire 1.5 sqmm from celing rose to connector, complete all as specified and directed. Make- Havells Model- ES-50 , Crompton, Model- HS Plus, Make- Orient, Model- Energy Star
Supply and fixing Exhaust fan plastic body with louvers and fixing accessories, 230 volts, 250 mm sweep including connection with flat 3 core copper wire 1.5 sqmm from celing rose to connector, complete all as specified and directed.
Supply and fix 15mm bore pipe/tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floorscomplete all as specified and directed.
Supply and fix stop valve cast copper alloy screwed both end for iron pipe with crutch or butterfly handle 15 mm dia pipe complete all as specified and directed.
Supply and fix Bib taps cast copper alloy screwed both end for iron pipe with crutch or butterfly handle 15 mm dia pipe complete all as specified and directed.
Supply Install and testing water heater vertical storage type 25 Ltrs capacity having stainless steel inner tank with glass enamelled coating BEE 5 star rating, closed /ventilated type, 240 volts, glass coated heating element complete with all accessories, fixing arrangement with suitable size of fastner, nuts, bolts and washers including 02 nos PVC connection inlet & outlet pipe 450 mm long suitable for 'hot' & 'cold' water etc and making good disturbed surface with plaster in CM 1:4 complete all as specified and directed. Make- Havells Model- Monza DX/ Crompton, Model- AMICA/ Bajaj Model-SHAKTI NEO-25 LTR /Usha Model-Misty Digital
Supply, Install , testing and commissioning as in replacement single phase two wire, single source directly connected BIS marked IS 16444 Digital Energy Meter 10 to 60 Amps, 240 volts, accuracy Class 1.0 with GPRS/4G module for connectivity with HES & having LCD type display callibration LED, optical communication port, push button for scroll and having features for load disconnection through internal latching relay, complete all as specified and directed.
Material & Labour for Configration of server to prepare the consumer database, tariff creation,setting of load limit, meter allotment, billing along with Mobile apps facility & training to staff complete all as specified and directed.
Transaction charges for recharge transaction complete all as specified and directed.
Supply of VPN IPV6 static SIM CARD Charges as directed.
EXTERNAL ELECTRIFICATION
Taking down defective/old LT services cable/ UG cable PVC insulated armoured XLPE with aluminium conductor 1100 volt grade of any size and capacity from trenches/floors/poles complete all as specified and directed.
Supply and laying in trenches / ducts, passing through GI pipe / fixing on poles 1100 volts grade, 25 Sqmm 4 core, electric power cable (heavy duty), XLPE insulated armoured heavy duty and PVC sheathed galvanised steel strip or wire armoured with stranded aluminium conductor including commissioning and testing complete all as specified and directed.
M&L river washed and screeened dry fine sand filling in trenches below and above / around under ground cable for cable protection including punniing around cable complete all as specified and directed. (Note: Punned thickness shall be measured.)
M & L for laying sub class 'B' brick laid flat with width equal to length of brick as in protection covers over cables complete all as specified and directed.
Supply, laying and fixing 40 mm bore galvanised steel tubes light grade, with all fittings, laid in trenches for cable protection complete all as specified and directed.
Note:- Excavation & Earth Work shall be measured under respective items here-in-before.
Note : Tenderers may note that amount of credit Rs 922444.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
mohanlal gupta
Shree Construction Co.
yash enterprises
S. K. CONSTRUCTION
M/S Chhavi Constructions Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .