| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹29.7 L+₹3.7 L (14.3%)Rejected-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-AOC Neither lowest nor competitive | |
| 3 | L3₹34.7 L+₹8.7 L (33.7%)Rejected-AOC | L3 | Rejected-AOC Neither lowest nor competitive | |
| 4 | L4₹39.6 L+₹13.6 L (52.4%)Rejected-AOC | L4 | Rejected-AOC Neither lowest nor competitive | |
| 5 | L5₹41.9 L+₹16.0 L (61.5%)Rejected-AOC BARIYAWAN BARIYAWAN BARIYAWAN BARIYAWAN AMBEDKAR NAGAR UTTAR PRADESH 224210 | AMBEDKAR NAGAR | UTTAR PRADESH | 224210 | L5 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
27 Jan 2021, 6:00 pmClosed
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
REPAIR /REPCEMENT OF OLD UNSV CFL/FTL FITTINGS WITH LED FITTINGS AND FIXTURES AND OTHER MISC WORK AT RRRC ICHHAMATI LINE MYNAMATI LINE TRG AREA DK-I DK-II AND ADJOINING AREA UNDER GE (CENTRAL) DELHI CANTT
2021_MES_408831_1
GE/C-70/2020-21
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
120 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹98,000
Yes
6 Mar 2021
1 Jan 2021
29 Jan 2021
1 Jan 2021
27 Jan 2021
15 Jan 2021
1 Jan 2021 - 15 Jan 2021
Amount
Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed
Supply and fix in replacement LED batten luminaire surface mounted 2 feet system wattage of 12 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. (Mirror light)
Supply and fix in replacement LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complerte all as specifed and directed by Engineer-in-Charge.
Supply and Fixing in replacement LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complerte all as specifed and directed by Engineer-in-Charge. .
Supply and Fixing in replacement LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complerte all as specifed and directed by Engineer-in-Charge. .
Supply and fix in replacement LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complerte all as specifed and directed by Engineer-in-Charge.
Supply and fix in replacement surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and Fix in replacement 45W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
S & F electronic driver with high voltage protection upto 380 Volt AC suitable for LED recessed mount 2"x2", 36/40 watt including connecting complete with connected accessories at given site complete all as specified and directed by engr-in-charge. Make:as per sample
S & F electronic driver with high voltage protection upto 380 Volt ACdriver suitable for LED surface mounted 12/15 watt ceiling light including connecting complete with connected accessories at given site complete all as specified and directed by engr-in-charge. Make:as per sample
S & F electronic driver with high voltage protection upto 380 Volt AC suitable for LED building security light, 30 watt including connecting complete with connected accessories at given site complete all as specified and directed by engr-in-charge.
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by engr-in-charge. .
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 1.5 sqmm (nominal dia) FRLS 1100 Volts in existing PVC concealed conduit incl new M S steel terminal boxes of wall thickness not less than 1.6mm including 3 mm thick laminated top sheet cover including using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for the follwing point controlled by one No one way switch all as specified and directed by Engr-in-Charge.
One light/fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 14 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board.
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 1.5 sqmm (nominal dia) FRLS 1100 Volts in new PVC concealed conduit in new M S steel terminal boxes of wall thickness not less than 1.6mm including 3 mm thick laminated top sheet cover including using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one follwing point controlled by one No one way switch all as specified and directed by Engr-in-Charge.
One light/ fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 16 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by engr-in-charge. .
M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge..
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge. .
M&L in replacement socket outlet 6 Amp flush button type complete all as specified and directed by Engineer in charge.
M&L in replacement regulator electronic switch type 5 steps suitable for 1200/1400 mm sweep 230 volts complete all as specified and directed by Engineer in charge.
M&L in replacement regulator electronic socket type 5 steps suitable for 1200/1400 mm sweep 230 volts complete all as specified and directed by Engineer in charge.
M&L in replacement bell electric (dingdong) 230 volt, SP complete all as specified and directed by Engineer in charge.
M&L in replacement Buzzer, AC, 230 Volts, single pole, complete all as specified and directed by Engineer in charge.
M/L in replacement insulated body, angle holder (metal ring) with back plate ISI marked complete all as specified and directed by Engineer in charge.
S&F ceiling rose surface PVC 65x50 mm type with three terminalscomplete all as specified and directed by Engineer in charge..
M&L in replacement modular stepped type electronic fan regulator 120W, 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 3 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
All as above item No 38 but with single pole MCB 'C' series 20 Amps.
Supply and fix M&L in replacement MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting
Supply and fix M&L in replacement MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
Supply and fix M&L in replacement MCCB 63 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
Supply and fix M&L in replacement MCB SPN 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix M&L in replacement MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix M&L in replacement MCB SPN 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix M&L in replacement MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S & F exhaust fan 230 mm in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor from ceiling rose to fan, length as per requirement at site.
S & F exhaust fan M&L in replacemen declared BER by BOO 300 mm in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor from ceiling rose to fan, length as per requirement at site.
Supply and fixing Ventilating Fan in replacemen declared BER by BOO 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm complete all as specified and directed by engr-in-charge.
Supply and fixing Ventilating Fan in replacemen declared BER by BOO 200 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm complete all as specified and directed by engr-in-charge.
Supply and fix in repair Sub main wiring complete with two runs of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through new PVC conduit (concealed) complete all as specified and directed by engr-in-charge. Note: Three runs of 1.5 sqmm cable shall be measured as one RM.
Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing conduit/ surface on walls complete all as specified and directed by engr-in-charge. Note: Three runs of 4 sqmm cable shall be measured as one RM.
Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through new PVC conduit (concealed) complete all as specified and directed by engr-in-charge. Note: Three runs of 4 sqmm cable shall be measured as one RM.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing conduit in walls complete all as specified and directed by engr-in-charge. Note: Three runs of 6 sqmm cable shall be measured as one RM.
S & F PVC Gang box surface type heavy duty suitable for single switch 5 Amps complete all as specified and directed by Engineer-in-charge
S & F PVC Gang box surface type heavy duty suitable for single 5 Amps switch & socket complete all as specified and directed by Engineer-in-charge
S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer-in-charge
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 10 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 3 core PVC insulated of size 40/.0076 ll as specified and directed by Engr-in-Charge.
M & L in replacement for only twin core PVC insulated unarmoured cable 10 Sqmm Flat 1100 Volts with Aluminium multi stranded conductor complete all as specified and directed by Engr-in-Charge.
M & L in replacement for only twin core PVC insulated unarmoured cable 6 Sqmm Flat 1100 Volts with Aluminium multi stranded conductor complete all as specified and directed by Engr-in-Charge.
S & F hole fastner madeup of MS 6" long with complete nut bolt all as specified.Make:as per sample
S & F hole fastner madeup of MS 4" long with complete nut bolt all as specified.Make:as per sample
S&F GI Pipe bracket bent to shape drilled welded made out of light grade GI pipe 32/40mm dia 1.5 mtr long and fixing on the wall where as directed by the Engr-in-Charge for fixing of building security light fitting including MS clamps, nuts, bolts and washers complete all as specified by the Engr-in-Charge .
S&F in replacement plug top, 3 pin, 10/20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer-in-charge
S&F in replacement socket 3 10/20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer-in-charge
M & L in replacement plug top 3 pin, 5 Amp all as specified and directed by Engr-in-charge.
M & L in replacement plug top 3 pin, 15 Amp all as specified and directed by Engr-in-charge.
M & L in replacement tape roll 25mm size 25 mtr length all as specified and directed by Engr-in-charge.
S & F in replacement switch socket combination 15 Amp all as specified and directed by Engr-in-charge.
S & F in replacement switch socket combination 5 Amp all as specified and directed by Engr-in-charge.
Supply & fixing in replacement exhaust fan motor capacity 1/4 HP 230 volts suitable for 300 mm size exhaust fan complete all as directed.
Supply & fixing in replacement PVC fresh air fan blade suitable for 250/200 mm size with all fixing accessories complete all as spd and directed.
Supply and fix in replacement wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed.
S&F in replacement garden light ABS plastic with 10 Watt LED bulb, poles, service wire and cement work etc all as specified and directed. Make :- As per sample
Supply and fixing in replacement LED Bollard integral decorative with PMMA diffuser 10 watt of height 0.6 meter with IP 65 protection suitable for single phase 230 volts 50 HZ AC Supply including LED bulb complete all as specified and directed.
Note :- Total amount of Sch of credit is 126205.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
M/s Adhikari construction co.
Pall Associates
M/s S.G. BUILDERS
m/s VK construction company
New Era Engineers
somyaenterprises
DHAIRYAE ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .