Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹93 L
EMD Value
₹93,000
Closing Date
5 Apr 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC-I ALIGARH
LAL DIGGI ALIGARH
Jawan Nagar Panchayat
2023_DVVNL_789217_2
EDCA-63/2022-23
Open Tender
Electrical Works
Turn-key
30 days
EDD-III
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
DVVNL Agra Web Site
₹93,000
6 Apr 2023
30 Mar 2023
5 Apr 2023
30 Mar 2023
5 Apr 2023
30 Mar 2023
Amount
PCC Pole 8.5 Mtr. Long
ST Pole 11 Mtr. Long
Stone Pad
M.S. Top Channal (125X65X2240mm) with clamp
Dropper Channal (100X50X2028mm) with clamp
MS Tee-off channal with clamp and B&N
V-Type Steel cross arm with clamp
11 KV Pin Insulator with Pin complete
11 KV Disc Insulator with fitting
F-Bracket for fitting Top Channal
Phase wire ACSR Weasal Conductor
Danger Plate with clamp N&B
Danger Board with clamp
Barbed wire GI
Earthing complete
Stay Complete with concreating
PG Clamp for Dog
Bold & Nut warshel clamp
Concreting of Pole
Number Plate
Aluminium Tape
Aluminium Paint
Red Oxide Paint
Cable ABC 3X95+1X70+1X16 Sq.mm.
ABC LT 3.5x95+1x25+1x16 Sq.mm.
11 KV XLPE Cable 3X185 Sq.mm.
11 KV Cable Jointing kit 3x185 Sq.mm. O/D
GI Pipe 6" Dia
HDPE Pipe (160mm dia for underground laying of 3*185 Sq.mm. 11 KV XLPE cable (Pipe to be laid by HDD Method.)
Eye Hook
Piercing Connector
LT Insulator Pearsing connector
Suspension clamp with Eye Hook
Distribution Box with clamp
End Clamp
Dead End Clamp
11/0.4 KV 250 KVA Transformer
11/0.4 KV 63 KVA Transformer
PVC Cable AL 3.5x240 Sq.mm.
PVC Cable AL 3.5x70 Sq.mm.
LT XLPE Cable 1x240 Sq.mm.
Al. Lug 240 Sq.mm.
Body and neutral earthing of following L.T. distribution Transformers installed by digging of pit up to water level depth (approx. 100’) and then inserting 1-1/4" dia G.I. pipe of "B" grade, conforming to the requirement of IS specification and then connecting the top of the inserted pipe and transformer body through GI strip of size 50x6 mm with the help of nut and bolt or through gas welding, as per direction of supervising engineer including the cost of arrangement of all material, labourer, T&P, carrier etc. required for proper completion of work.
250 KVA Transformer
Construction of following Transformer of Plinth of size 5’x5x4’ above ground level and one ft. below the ground level of 9”. After excavation of 4” earth, brick ballast shall be provided and rammering will be done properly after that a retaining wall of 9” width by first class brick in ratio 1:4 of cement and sand shall be made. The earth shall be filled up to one ft. below the top of the plinth. After this brick ballast shall be provided up to 6” from the earth level and proper rammering shall be done. One No. jall of 12 mm M.S. tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement, sand and stone ballast shall be laid on the top of the Plinth. The 12 mm thick plastering shall be done all around the plinth in 1:4 ratio of cement and sand. The contractor shall be responsible to complete the work as per direction of Supervising Engineer. It including the cost of all material, labour T&P, carrier etc. required for proper completion of work.
250 KVA Transformer
FABRICATION & ERECTION OF FENCING AND CONSTRUCTION OF RETAINING WALL AROUND FOLLOWING CAPACITY T/F The complete 11/0.4 KV Substation shall be provided with two meter height fencing and retaining wall around the substation. One No. Gate with proper locking arrangement for entry of personnel shall also be provided. The fencing shall be made of 50x25 mm x10 SWG rectangular welded mesh of wire mesh in length. Wire mesh shall be fixed on panels made of 50x50x6 mm M.S. Angle. The wire mesh on panels will be supported by 25x3 mm M.S. flat on all the bracings diagonally and 50x6 M.S. Flat horizontally at the center of the panel. The panel will be joined by bolts & nuts of appropriate size with each other and on the main support on corners including supply of all material, labour, carrier and T & P etc. required for proper completion of work. The painting of complete fencing shall also be done with one coat of red oxide primer and two coat of synthetic green paint. For construction of retaining wall around the fencing, excavation of earth shall be done in foundation in ordinary soil including disposal of surplus earth at some suitable distance. The dimension of excavation shall be 1m wide, 0.45 m deep and suitable length as per wire mesh. After excavation of earth a cement concreted pad shall be laid in foundation. Concreting shall be done with Ist class brick ballast, coarse sand and cement in proportion of 8:4:1. First class brickwork shall also be done in foundation and super structure in 1:6 Cement and coarse sand including necessary cutting and moulding of bricks in foundation depth of wall 0.30 m, thickness of wall 0.35 m & superstructure brick work thickness of wall 0.23 m & depths 0.30 m including supply of all material, labour, carrier and T & P etc. required for proper completion of work.
250 KVA Transformer
Demounting & carriage of following capacity transformer due to overloaded including the work of its loading & unloading, dragging etc. and also including the cost of labour and T&P etc. required for proper completion of work.
25 KVA Transformer
100 KVA Transformer
Dismantling and removal of existing conductor/cable/GI Wire from the various area preparing their coils and then stacking in the respective JE’s (Store) as per direction of Supervising Engineer. It includes the work of cartage, cost of labour, T&P carrier etc. required for proper completion of work.
ACSR Weasal conductor (Scrap)
Laying of HDPE pipe underground minimum 3 Mtr. below by HDD method trund less alongwith laying of 11 KV 3*185 Sq.mm. XLPE cable in HDPE Pipe.
Cable laying charges alongwith cost of bricks and send for cable loop and DP structor and also GI pipe.
KHAN ENTERPRISES
Vivek Electricals
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .