Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.7 LAdmitted-Finance | -31.51% | ₹7.7 L | L1 | Admitted-Finance |
| 2 | L2₹8.1 LAdmitted-Finance | -28.00% | ₹8.1 L | L2 | Admitted-Finance |
| 3 | L3₹8.8 LAdmitted-Finance | -22.00% | ₹8.8 L | L3 | Admitted-Finance |
| 4 | L4₹8.8 LAdmitted-Finance AJMER | RAJASTHAN | 305001 | -21.33% | ₹8.8 L | L4 | Admitted-Finance |
| 5 | L5₹10.7 LAdmitted-Finance | -5.00% | ₹10.7 L | L5 | Admitted-Finance |
Tender Value
₹11.2 L
EMD Value
₹22,480
Closing Date
24 Apr 2026, 11:00 amClosed
EE PHED RURAL DN BHILWARA
BHILWARA
BAMBOLA
2026_PHCJA_551246_2
NIT NO 04-06/2026-27 EE PHED RURAL DN BHILWARA
Open Tender
Civil Works
46 days
BHILWARA
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
EE PHED RURAL DN BHILWARA
₹22,480
Yes
4 May 2026
10 Apr 2026
24 Apr 2026
10 Apr 2026
24 Apr 2026
10 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283- 2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. | - | - | - | - | BI01010001010000000000000515BI0100001112 |
| 2 | Up to 5.5 KW (7.5 HP) & head above 120 mtr. | - | P.KW | - | - | BI01010001010000000000000515BI0100001113 |
| 3 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. | - | - | - | - | BI01010001010000000000000515BI0100001114 |
| 4 | Above 5 HP and up to 10 HP | - | Each | - | - | BI01010001010000000000000515BI0100001115 |
| 5 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. | - | - | - | - | BI01010001010000000000000515BI0100001116 |
| 6 | 3 core 6.0 Sq.mm | - | Mtr | - | - | BI01010001010000000000000515BI0100001117 |
| 7 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. | - | - | - | - | BI01010001010000000000000515BI0100001118 |
| 8 | 16.0 Sq.mm, 4 core | - | Mtr | - | - | BI01010001010000000000000515BI0100001119 |
| 9 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .
Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
Supply may be in coil or straight length in 6 M/12 M. | - | - | - | - | BI01010001010000000000000515BI0100001120 |
| 10 | HDPE PE-80 PN-6 | - | - | - | - | BI01010001010000000000000515BI0100001121 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
5A.pdf
Tender Documents • 1.60 MB
BOQ_982398.xls
BOQ • 0.33 MB