Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC 21 KAWARDHA COLLECTORATE ROAD KAWARDHA KABIRDHAM CHHATTISGARH 491995 | KABIRDHAM | CHHATTISGARH | 491995 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.6 L+₹2.8 L (13.7%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹26.1 L+₹5.3 L (25.7%)Rejected-Finance 10 2 NARAYAN BAG INDORE M P | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹26.4 L+₹5.6 L (27.0%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹26.6 L+₹5.8 L (28.1%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School , Mhow - 453441
REPAIR MAINT OF LT NETWORK SYSTEM AND CONNECTED WORKS UNDER GE MAINT INF SCHOOL MHOW
2023_MES_623889_1
8606/GE(MIS)/MHOW
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
INFANTRY SCHOOL MHOW
All as per Tender document
7 documents required · 7 mandatory
₹500
Garrison Engineer (Maint) Inf School
₹50,000
Yes
6 Dec 2023
18 Oct 2023
17 Nov 2023
18 Oct 2023
15 Nov 2023
1 Nov 2023
Amount
M&L for dismantaling carefully old cracked /unserviceable PCC poles /MS pole / struts of any type a,size and height by disconnecting electrical connection including concrete foundation etc complete all as specified and directed by Engineer-in-Charge .
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying cable, pole foundation etc complete all as specified.
All as per item No 02 above depth exceeding 1.5m but not exceeding 3.0m
M&L for Plain cement concrete 1:2:4 type B2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified
M&L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified
M&L for plain cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as in roof kerbs or pole coping of size 300x300 mm ,chamfered on edges including necessary formwork complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M&L for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete. Note :- Thickness shall be measured after punning
M&L for old size sub class ‘B’ bricks, laid in trenches as a cable covers complete.
S&F steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall complete.
S&F steel tubes, galvanised, light grade, ISI marked 80mm bore for protection of cable under floor, road and on wall complete.
M&L for Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally complete all as specified and directed. Note : Excavation & earth work and PCC shall be measrued and paid separately under relevant item. Make : India Tube and Co, Kalinga tubes, The National tubing company, India Electric Poles Mfg Co
Supply and laying cable with copper conductor PVC round sheathed (flexible) industrial cable of size 10 sqmm including necessary copper lugs complete all as specified
Supply and laying cable with copper conductor PVC round sheathed (flexible) industrial cable of size 4 sqmm including necessary copper lugs complete all as specified
Supply and fix in replacement of Battery parallel plate type of capacity 12 V, 180 AH. Make:- Exide, Amron or other equivalent as approved by GE
M&L for Repair/servicing of Battery charger including replacement of step down transformer 240/12 V, fuse of required size and checking and calibration of voltmeter, Ammeter all as specified and directed by Engineer-in-charge.
M&L for attending external electric complaints by opening / disconnecting the electrical connection of defective / burnt out underground LT cable of any size & any core from main switch / DB / junction box / LT panel / L T O/H line etc. and taking out the required length of cable from existing loop and remove/ cut the defective cable,replace the same with new cable as per existing size including providing necessary thimbles / connectors at cable end and reconnecting the cable in previous location with existing main switch / DB / Junction box / LT panel / OH line etc. and make electic connection as functionable in all repspects including testing on completion all as specified and directed by Engineer-in-charge.
Note:- (A) The quoted rate shall be inclusive of the following: (i) Necessary earth work excavation as required for finding/attemding faullt /in any type of soil, returning filling and removing extra soil. (ii) Existing bricks, sand,GI protection pipe etc. shall be removed carefully and stacked neatly near site and re- laid the same in position after attending fault/defect. (iii) Distrubed surface of road, floor etc. shall be make good to match with existing surface. (iv) Required numbers of electrician and helper shall be deployed for attending complaints regulerly on daily basis and contractor shall collect the complaints details from complaint cell of AGE E/M No.1 and same shall be rectified/ attanded within an hour and report shall be submitted to Engineer-in-charge or their authorised representative. (B) Please note that payment shall be made to contractor one time only for this items. if any fault/ default occured again on the same location/ DB/junction box/panel during currency of contract, the same shall be rectified by the contractor without any extra cost to Govt. in terms of condition 46 of IAFW 2249 of Genral condition of contracts. (C) Additional bricks,sand,GI pipe etc. as required for cable protection and cushioning shall be measured and paid separetely under relevant item.
M&L for dismantling / disconnecting / removing the faulty / burnt out overhead conductor of any type / size from insulator of HT / LT pole any type by making proper shutdown from department and removing of tree / branches if any fell on Over Head Line, loose the binding wire in each insulators and disconnecting cable connection as required, remove the burnt / damage conductor / earth wire and making necessary joint with new ACSR conductor of suitable size as per existing as directed, restretching all loose spans of ACSR conductors, earth wire etc. with insulator and providing binding wire of existing size to tigheting and making LT/HT cable in existing position and make electric connection as functionable in all respects including testing on completion allas specified and directed by Engineer in charge.
NOTE: (a) The quoted rate shall be inclusive of the following:- (i) Tools and plants such as ladder,rope, cutter, axes, knife etc. as required for cutting and removing tree/branches if any fall on OH line. (ii) Insulator,binding wire etc. as required in addition to existing shall be provided by the contractor. (iii) Required numbers of Elecrician and helper shall be deployed for attending complaint regularly on daily basis and contractor shall collect the complaint details from complaint cell of AGE E/M No. 1 (b) Additional ACSR conductor and earth wire shall be measured and paid separetely under relevant items.
S&F in replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S&F in replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
M&L for Painting of transformer of capacity up to 750 KVA, 11/.433 KV by applying two coats of synthetic enamelled paint over a coat of primer by using spraying machine including preparation of transformer surface and removal of rusted portion complete all as specified and directed.
M&L for Tracing out fault upto 11KV underground cable of any size by using fault tracing machine and rectifying the same by cutting and removing defective cable ,providing necessary cable of same size and jointing with existing cable all as specified and directed by Engineer-in-Charge to restore the electric supply complete all as specified and directed by Engineer-in-Charge. Note: (i). Joint kit shall be measured and paid separately. (ii) Earth work eacavation shall be measured and paid separately. However, width of trenches shall be allowed for payment as per authorized width as given in SSR part I for each size of cable. (iii) All other necessary arrangements suitable for locating the faults such as fault checking instrument etc shall deemed to be included in the unit quoted rate . (iv) T&P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account. (v) Cable required, if any shall be measured and paid for separately.
M&L for trimming /pruning of tree branches touching to the LT over head line or near to the LT over head line as per direction of Engineer-in- charge complete including removing the tree branches from site complete all as specified and directed . NOTE : (a) A written shut down shall be obtained from concerned JE / AGE E/M before carrying out the trimming work in hand by contractor (b) Approximate span between poles shall be 30 to 50m. (c) T & P such as ladder , rope, cutter , axes and other related material shall be provided by the contractor.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm.
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable UG cable for the following sizes. Note: Earth work, excavation, sand cusioning, bricks for protection, GI pipe etc shall be measured and paid separately under relevant items of this schedule .
16 sqmm 4.0 core
25 sqmm 3.5 core
35 sqmm 3.5 core
50 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 Sqmm 3.5 core.
120 Sqmm 3.5 core.
185 Sqmm 3.5 core.
240 Sqmm 3.5 core.
S&F in repairs Aluminium lugs suitable for cable of following size
16 sqmm 4 core
25 sqmm 3.5 core
35 sqmm 3.5 core
50 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 Sqmm 3.5 core.
120 Sqmm 3.5 core.
185 Sqmm 3.5 core.
240 Sqmm 3.5 core.
S&F in replacement of MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA
S&F in replacement of MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA
S&F in replacement of MCCB 3 pole, 415 volts, adjustable type 160 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 3 pole, 415 volts, adjustable type 200 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 3 pole, 415 volts, adjustable type 250 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 3 pole, 415 volts, adjustable type 350 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 3 pole, 415 volts, adjustable type 400 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 4 pole, 415 volts, adjustable type 250 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 4 pole, 415 volts, adjustable type 350 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 4 pole, 415 volts, adjustable type 400 Amps with breaking capacity 36 KA
S&F in replacement of pin type porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade.
All as per item No 38 above but 150mm height, 150mm dia for 11000 volts grade.
S&F in replacement of shackle type porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 75 mm and max dia 90 mm suitable for working pressure 1100 volts grade.
All as per item No 40 above but 150mm height, 150mm dia for 11000 volts grade.
S&F in replacement of disc insulator, porcelain, vitreous 145 mm high and 255,, dia ball and socket type, white, brown or green suitable for single disc asst for tension with tension clamps for conductors, working pressure 11000 volts grade.
M&L for replacement of broken over head conductor of any type and length as required at site supply and fix ACSR conductor of size and type as per existing complete all as specified and directed .
M&L for Restringing of loose over head conductor / GI earth wire of any size and type after untyeing binding wire from insulators / cross arms to achieve permissible sag limit of over head line including new binding wire of proper size and pruning of tree branches of concerned spans and jointing of jumpers properly complete all as specified and directed at site. Note:- (i) Each span shall consist of 3 phase , 4-wire over head line. (ii) The distance of one span between poles shall be 30 to 50 metre .
S&F in repalcement of straight through joint ( Epoxy joint) for following size PVC insulated and sheathed aluminium conductor cable complete for following sizes :-
2 /4 core 10 sqmm to 25 sqmm
3.5 core 25 to 35 sqmm
3.5 core 50 sq mm
3.5 core 70 sq mm
3.5 core 95 sq mm
3.5 core 120 sqmm to 150 sqmm
3.5 core 185 sqmm
S&F in repalcement of 11 KV (E) straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cabe of size 50 to 95 sqmm.
All as per Sl item No 46 above but for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE aromoured aluminium conductor cable of size 50 sqmm to 95 sqmm.
All as per Sl item No 46 above but for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE aromoured aluminium conductor cable of size 50 sq mm to 95 sq mm.
M&L for repairing damaged /corroded portion of existing LT panel board of any size by providing and welding MS sheet of existing thickness, replacing hinges, aldrop bolt as required and made for proper locking system and painting internal and external surface of LT panel with one coat of synthetic enamel paint of approved colour all as specified & directed by Engineer-in-charge.
M&L for Maintenance of indoor sub stations, including cleaning of premises and surroundings upto 5m from outer face of wall, checking the oil level of transformers, cleaning and dusting out of transformers, panel boards, cleaning of earth pits to keep free from vegetation and spray Glphosate 41% chemical by using spraying machine etc complete all as directed by Engineer-in-Charge . Note:- Glphosate 41% chemical shall be measured and paid separately under respective item .
All as per item No 51 here in before but for out door sub station including levelling of loose filled aggregate in proper manner around substation
Supply only Glphosate 41% chemical
S&F in repairs mild steel galvanised stay assembly set complete comprising of 20mm dia, 400mm long stay bow, 1800 mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, GI stay wire of 7/8 SWG upto required length including loop type insulator of vitreous porcelain, small size with overall dimensions 90x140mm, clearance of hole 25.5mm, all as shown in electrical plate No.1 of MES Schedule part I 2009 complete all as directed.
M&L for replacement of blown out DO fuse, 33/ 11 KV grade of any capacity .Note: Each pocket consisting of 20 pieces.
M&L for replacement of Danger notice plate of size 20x15 cm for LT cable and 25x20cm for HT cable with 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size complete all as directed by Engineer-in-charge.
M&L for preparing surface of street light ,steel tubular swaged/ swan neck pole of any type and painting with two coats of aluminium paint over a coat primer from top to bottomincluding painting to cross arms /FI clamps/street light brackets of any type including making painting alternative bay with blak and yellow strip with synthethic enemelled paint up to 1.5 meter height from ground level and writing of pole numbers with black paint on poles complete all as specified
M&L for preparation of old painted surface of LT PCC street light pole up to 1.50 m height from top of PCC foundation block and painting the pole in alternative strips with black and white Radiant paint (each strip 30cm high) and including writing pole nos. and applying one coat of cement base paint on exposed surface of PCC coping and foundation blocks complete all as specified and as directrd by Engineer-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode of size 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
Supply, fabrication, installation, testing and commissioning of out door type LT panel board of size 1500mm x 1200 mm x 500 mm cubical type,made out of 3.00mm thick CRCA sheet , factory made,with slanting top ,minimum 10 Cm projection all around, fedder pillar type,fabricated with 50x50x6mm angle iron frame work with front and back side openable single hinged door / shutter with locking arrangments, floor mounting type, busbars made of copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours,bus bar shall be properly supported/mounted on epoxy insulators ,all live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provision for connecting suitable earth strips,painting with one coat of anti corrosive coating and finally epoxy polyester powder coating, and confirming relavent IS, comprising the adequate arrangement to supply & fix the following accessories,including connecting cable glands,enamelled danger notice plate of 1.60mm thick miled steel sheet of size 200mm x 150 mm and cable lugs,fixing of earth lead to earth terminal of panel including necessary earth work excavation , PCC foundation etc as required at site complete all as specified and directed by Engineer-in-Charge.Note:- Quoted rate shall inclusive for all following accessories
Incoming
(a) Copper strip bus bar - 800 Amps rating wrapped with PVC Sleeves colour code and provn of making holes, nincl nut bolts etc at both end. - 04 Nos .
(b) MCCB 4 pole 400 Amps, 415 volt, 36 KA - 01 No ( incoming)
(e )ON/OFF LED Neon type indication lamp with toggle switch - Set of 03
Out going:-
(a) MCCB 4 pole 250Amp, 415 volt, 25 KA - 01 No
(b) MCCB 4 pole 200 Amp, 415 volt, 25 KA - 02 Nos
(c) MCCB 4 pole 100 Amp, 415 volt, 25 KA - 04 Nos
ENVIRO TECH SERVICES
S.S. Engineers
MODI CORPORATION
Ms Kailash Chandra Babulal
Vending Services And Solutions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .