Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC ok | |
| 2 | L2₹7.6 L+₹2.0 L (36.2%)Rejected-AOC LOKMAT BHAWAN A WING 808 WARDHA ROAD RAMDASPETH NAGPUR 440010 | NAGPUR | MAHARASHTRA | 440010 | L2 | Rejected-AOC ok | |
| 3 | L3₹8.2 L+₹2.6 L (46.7%)Rejected-AOC 142 JAGJIVANRAM NAGAR GAROBA MAIDAN NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | L3 | Rejected-AOC ok |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
17 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AF Sonegaon, Nagpur
Bldg No. P-51, 44 wing Air Force Station, Sonegaon, Nagpur 440 005
REPAIR AND MAINT OF SECURITY / STREET LIGHTS AND DAY TO DAY MAINT OF E/M STORES FITTINGS AND FIXTURES AT SONEGAON NAGPUR
2020_MES_380269_1
8354/E8
Open Tender
Civil Works
Item Rate
180 days
Sonegaon
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE (I) AF Sonegaon, Nagpur
₹15,000
Yes
18 Nov 2020
23 Sept 2020
19 Oct 2020
23 Sept 2020
17 Oct 2020
5 Oct 2020
23 Sept 2020 - 3 Oct 2020
60 days
Amount
Taking down carefully unserviceable street light fitting, high pressure, sodium vapour lamp type, 70 to 250 watts from poles,DSS & MT R &S hanger after disconnecting supply and sealing the cable ends for carrying out repair/maintenance at site/work shop and refixing the same on pole, connecting up and testing complete all as specified and directed. Note : (i) Spares required for repair of the fitting shall be measured and paid seperately under the item No. 2,3,4,5,6& 7 here in after as "Supply only". However, the labour cost for taking down spares & fixing shall deemed to be included in the quoted rate. (ii) Unserviceable spare parts shall be contractors property as per Sch of Credit.
Supply only the spares required for replacement of spares during the process of repair of the light fitting vide SI item No 1 here in before complete all as specified and directed.
Open construction ballast 70 watts copper wound for HPSV/metal healide lamp.
Ignitor for HPSV lamp suitable for 70 to 250 watt.
Condenser 15/20 mfd.
Condenser 33 mfd.
Holder Screw type for tubular HPSV/HPMV lamp 70 to 250watts
Open construction ballast 150 watts copper wound for HPSV/MH lamp.
Open construction ballast 250 watts copper wound for HPSV/MH lamp.
S & F HPSV 70W lamp, tubular type/suitable for posttop latern complete all as specified and directed.
S & F HPSV 150W lamp, tubular type complete all as specified and directed.
S & F HPSV 250W lamp, tubular type complete all as specified and directed.
S & F Matal Hallide Lamp 150 W, tubular, clear complete all as specified and directed.
S & F Matal Hallide Lamp 250 W, tubular, clear complete all as specified and directed.
Taking down carefully unserviceable Flood light fitting, MH type, 400 watts from high mast 12 mts long pole, Watch Towers including repaire of watch tower pannel wiring & DSS hanger/MTR&S hanger/ Tubular Poles, after disconnecting supply and sealing the cable ends for carrying out repair/maintenance at site/work shop and refixing the same on high mast 12 mts long pole, Watch Towers & Tubular Poles, connecting up and testing complete all as specified and directed. Note : (i) Spares required for repair of the fitting shall be measured and paid seperately under the item No 9 here in after as "Supply only". However, the labour cost for taking down spares & fixing shall deemed to be included in the quoted rate. (ii) Unserviceable spare parts shall be contractors property as per Sch of Credit.
Supply only the spares required for replacement of spares during the process of repair of the light fitting vide SI item No 8 here in before complete all as specified and directed.
Ballast for Metal hallide lamp 400 watts.
Super imposed lgnitor for MH lamp suitable for 400W MH lamp.
Matal Hallide Lamp 400 W, tubular, clear.
Taking down carefully unserviceable Security/post top latern light fitting, CFL Type, 2 x 18 watts inbuilt ballast, L type lamp from wall/pole after disconnecting supply and sealing the cable ends for carrying out repair/maintenance at site/work shop and refixing the same on watch tower/Pole, connecting up and testing complete all as specified and directed. Note : (i) Spares required for repair of the fitting shall be measured and paid seperately under the item No 11 here in after as "Supply only". However, the labour cost for taking down spares & fixing shall deemed to be included in the quoted rate. (ii) Unserviceable spare parts shall be contractors property as per Sch of Credit.
Supply only the spares required for replacement of spares during the process of repair of the light fitting vide SI item No 10 here in before complete all as specified and directed.
Open construction VPIT ballast, copper wound for CFl 18 Watt. Make-118CFL bajaj/CG.
CFL 18 watts 4pin type S type make.
Holder4pin type for CFL 18 watts fittings.
Post top latern outer glass cover for existing fitting.
M & L for painting of Steel tubular poles of any size with two coats of aluminum paint including painting to cross arms and clamps etc including preparation of surfaces by scrubbing and cleaning with wire brush and renumbering the existing number of the pole as existing complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in soft/loose soil complete all as specified and as directed.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
M & L for providing dry river sand as in sand cusioning for underground cable protection including punning down sand in layers complete all as specified & directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supplying and laying common burnt clay sub class ‘B’ bricks of size 230 mm x 113 mm x 75 mm, laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed.
M & L road cutting of size 30 cm width x 45 cm depth for laying of cables incl making good the road with necessary returning fillingand bituminious portion with concret and bituminious mixture and cemented portion with PCC in 1:2:4 , 15 cm thick from top and matching the surfaces with existing all as directed.Near to logestic section
Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc for protection of cables complete all as specified and directed
Supplying, laying, testing and Commissioning cable XLPE insulated aluminium conductor,stranded, armoured, PVC sheathed, LT 1100 volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed of following sizes.
50 sqmm, 3.5 core
25 sqmm, 3.5 core
16 sqmm, 4 core
10 sqmm, 2 core
M & L for writing Pole No on PCC/steel poles with white synthetic enamelled paint on black background, size of lettter shall be 50 mm or less complete all as specified and directed.
S&F repairs LED street light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 90 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron braket or GI pipe in angle complete all as specified and directed. make-CG cat no LSTN-90CDL-A,PHILIPS,WIPRO
S&F repairs LED Flood light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 150 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron braket or GI pipe in angle complete all as specified and directed. make-CG cat no LFLN-150CDL-A,PHILIPS,WIPRO
M&L for Rectification of cable faults including provision of straight through cable joint LT Epoxy complete with resine and hardner for cable of size 70 Sqmm 3.5 core complete all as specified and directed Make:- M-Seal / Denson / Rachem
M&L for Rectification of cable faults including provision of straight through cable joint LT Epoxy complete with resine and hardner for cable of size 35 Sqmm 3.5 core complete all as specified and directed Make:- M-Seal / Denson / Rachem
M&L for Rectification of cable faults including provision of straight through cable joint LT Epoxy complete with resine and hardner for cable of size 25 Sqmm 4 core complete all as specified and directed Make:- M-Seal / Denson / Rachem
M & L for scrapping down rusted, fallen paint from the Electrical LT pannel situated at 44WING/TXR Area including rail/channel of base using mechanical scrapers, brushes, sand paper etc and removing the old paint to the complete outer surfaces and repainting external surfaces with black/yellow (strip) colour with applying a coat of red xide zinc chrome primer on the both internal & external portion where base metal is exposed, painting spray one coat of synthetic enamel paint for outdoor type panel including MCCB's specific cabinet complete all as specified and directed.
S&F Isolator TPN 415 volts 63 Amp AC with necessary connection in existing pannel/DB BOX.
S&F Isolator DP 240 volts 40 Amp AC with necessary connection in existing pannel/DB BOX.
S&F MCCBs four pole 415 volts. 16 KA ,100 Amp AC in existing panel board with modification /fabrication of existing panel boardas directed by E-in-Charge.
Taking down unserviceable switches, sockets,ceiling rose,fan condencers, regulator etc from site and supllying and fix in Repairs as under :-
S & F in repairs Modular switches 1way 6A ,1 module make - Anchor Roma or equivalent of Leader/Legrand
S & F in repairs Modular switches 1way 10A ,1 module make - Anchor Roma or equivalent of Leader/Legrand
S & F in repairs Socket , 6A-2/3 pin Combined 2 Module ,make - Anchor Roma or equivalent of Leader/Legrand
S & F in repairs Socket , 6A/16A -2/3 pin Combined 2 Module make - Anchor Roma or equivalent of Leader/Legrand
S & F in repairs Switch, 16A 1way ,1 module make - Anchor Roma or equivalent of Leader/Legrand
S & F in repairs SPN 240V ,DB 2Way make -: HPL/Legrand/Havells
S & F in repairs SPN 240V ,DB 4Way make -: HPL/Legrand/Havells
S & F in repairs SPN 415V ,DB 8Way make -: HPL/Legrand/Havells
switch piano type single pole one way, 5 Amps complete all as specified and directed.
switch piano type single pole one way, 15 Amps complete all as specified and directed.
Bell push piano type 5 Amps single pole on way complete all as specified and directed.
Bell/buzzer AC 230 Volts single pole complete all as specified and directed.
Switch socket combination piano type multi purpose, 2 in 1,3Pin,5& 15 Amp flush type complete all as specified and directed.
Switch socket outlet piano type , 3 pin 16 Amps all as specified and directed.
Switch socket outlet piano type,3 pin, 5 Amps, flush type, complete all as specified and directed.
Switch socket combination piano type, 5 pin, 5 Amps, flush type, multi purpose complete all as specified and directed.
Ceiling fan condencer 2.5 mfd Make-Epcos
Ceiling fan condencer 4 mfd Make-Epcos
Ceiling fan regulator electronic type AC 240 Volts, 50 Hz, single phase to be fixed in existig connection
Ceiling rose 2/3pin
Electrtonic ballast 36/40Watt Suitable for Tube Light 36/40 CFL/FTL Make-CG cat No-EBN136D/EBN 136 DN/Philips/Wipro
Electrtonic ballast for Tube Light T-5 28Watt CFL/FTL Make-CG cat No-ECLR136D/Philips/Wipro
Electrtonic ballast18 Watt for CFL 18Watt cap CFL/FTL Make-CG cat No-ECLR136D/Philips/Wipro
VPIT Copper ballast 36/40Watt Suitable for Tube Light 36/40 CFL/FTL Make-CG cat No-SFB7540/Philips/Wipro
Tube light starter suitable for 36/40 watt Make- CG cat No-FSU,Phillips
CFL lamp 4pin 1X36watt Pin Type for existing light fitting Make- CG cat No-4P 6500K/2700K/4000K,Phillips
CFL lamp 4pin 1X18watt CFL lamp for existing light fitting
FTL 36Watt Super saver tube rod make-CG/Philips/wipro
FTL 40Watt Super Brite tube rod make-CG/Philips/wipro
T5 28Watt 6500K/4000K/2700K tube rod make-CG/Philips/wipro
Insulation Tape roll size
Aluminium cable Lugs size 95Sqmm
Aluminium cable Lugs size 70Sqmm
Aluminium cable Lugs size 50Sqmm
Aluminium cable Lugs size 35Sqmm
Aluminium cable Lugs size 25Sqmm
M & L in repairs highly durable surface mounted LED batten constructed of fire retardant plastic & decirative end caps light fitting 18W complete all as directed Make-CG LCTL-18-CDL/Philips/Wipro
M & L in repairs highly durable surface mounted LED batten constructed of fire retardant plastic & decirative end caps light fitting 09W complete all as directed Make-CG LCTL-9-CDL/Philips/Wipro
LED 9W Make-9W-DF-CDL /Philips/Wipro
MCB DP 40A
Isolator SPN 40A
Isolator DP 63A
Isolator TP 63A
Isolator TPN 63A,415V AC
Isolator DP 32A
HT DO fuse siitable for 11KV 15A
MCB 6A to 32A SP 240V AC
supply only copper wire 1.5Sqmm single core complete all as specified & directed Make-: Plaza/Finolex
supply only copper wire 2.5Sqmm single core complete all as specified & directed.Make-: Plaza/Finolex
supply only copper wire 4.0Sqmm single core complete all as specified & directed.Make-: Plaza/Finolex
Supply & fix in repairs MCCB 3Pole 415V Fixed type 63A with breaking capacity16KA complete all as specified and directed.
Supply & Fix in repairs MCCB 4Pole 415V 125A with breaking capacity16KA complete all as specified and directed.
Supply 1100V grade heavy cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape & overall PVC sheathed 10Sqmm 2 core multi stranded nominal cross section in Service Connections.
Supply 1100V grade heavy cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape & overall PVC sheathed 6Sqmm 2 core multi stranded nominal cross section in Service Connections.
Taking down/shown carefully Ceiling fans any type & sizes & dismantling complete fan including strip opening, cutting & burnt copper welding, removing burnt sleeves, insulating papers cotton/Glass tapes, U/S bearings etc examine complete parts thoroughly , oiling, greasing all parts and complete overhauling fan incl replacement of small parts such as split pin, nut bolt screw and assembling complete All as directed by Eng-In-charge.
ditto as per item no 85 but for Exhaust fan any type capacity upto 450MM.
Rewinding of fan motor of C/Fan 1200 mm with suitable gauge of super enamelled copper wire including suitable Fan Bearing ,Capacitor varnishing, paper insulating, sleeving, glass typing, baking complete all as directed
Rewinding of fan motor of E/Fan Upto 450 mm with suitable gauge of super enamelled copper wire including suitable Fan Bearing ,Capacito varnishing, paper insulating, sleeving, glass typing, baking complete all as directed
M & L Painting of ceiling fans complete, in situ with synthetic enamel paint white/Brown by spraying including filling cavities with filler, one coat after cleaning all dust etc all as directed by eng-in-charge .
Taking down carefully storage type electric water heater (geysers) of capacity upto 25 Ltrs including repairs/replacement of washers, glands of all taps/valves to ensure water tightness and worn out minor parts including refixing in the position after testing and comprising the following task at different locations as directed by Engineer-in-Charge. (a) Inspecting the geysers checking the function of thermostat, dead weight high pressure release valve, ferule plug and indicator lamps etc. (b) Check and correct earth continuity of electrical item. (c) Preparation of surfaces by scarping out the existing paint completely and applying two coats of synthetic enamel white paint to the outer shell of geysers.
S & F inrepaire / replacement heating element upto 2 KW range
S&F in repair base apparatus plate complete with provision of inlet, outlet connections thermo state pocket, drain plug for fixing the heating elements complete all as specified
S&F in repair the insulating material (glass wool) upto 15Ltrs capacity geysers
Supply & Fix in repairs MCCB 4Pole 415V 200A with breaking capacity36KA complete all as specified and directed.
SRI JD CORPORATION
karambir constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .