| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.7 L+₹2.0 L (5.05%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹41.7 L+₹3.0 L (7.87%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹42.4 L+₹3.7 L (9.53%)Rejected-Finance JAISALMER | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹44.7 L+₹6.0 L (15.5%)Rejected-Finance GANDHI CHOWK MANIPURA JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
29 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Jaisalmer
GE Army Jaisalmer - 345001
REPAIR TO PLINTH PROTECTION, HARD STANDING, CLEANING OF SEWAGE LINE, SEPTIC TANK, SOAKAGE WELL AND CERTAIN MISC BR WORKS IN ASCON NODES AND CERTAIN AREA UNDER AGE BR-I AT GE (A) JAISALMER
2023_MES_602093_1
8309/23-24/E8
Open Tender
Civil Works
Item Rate
270 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹98,000
Yes
5 Apr 2024
8 Jun 2023
1 Jul 2023
8 Jun 2023
29 Jun 2023
22 Jun 2023
Amount
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-charge.
M&L for 100 mm thick Cement concrete 1:4:8 Type D2 using 40mm graded stone aggregate as in flooring or mass concrete complete all as specified and directed by Engineer-in-charge.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in flooring complete all as specified and directed by Engineer-in-charge.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning including removing the existing paver blocks including removing of debries out side MD land complete all as specified and directed. Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement.
M&L for non skid ceramic tiles colour 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed by Engineer-in-charge.
Demolition of brickwork or stone/ boulder masonry/block masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework complete all as specified and as directed by Engr-in-charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) but except stone complete all as specified & directed by Engineer-in-charge. Note :- Serviceable stone obtained from demolition shall be used.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses complete all as specified & directed by Engineer-in-charge.
M & L for Keyed pointing to random or polygonal rubble, uncoursed or brought upto coursein cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L, for precast cement concrete block masonry 1:3:6 type C1 (using 20mm graded stone aggeregate) with solid blocks, exc 10 cm in width and setting in mortar, complete in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing in cement mortar 1:6 & finished the surface even & fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces and applying two coats of cement based paint over a primer complete all as specified and as directed by Engr-in-Charge.
Dismantling of posts or struts (wood, steel or RCC ) any section including taking out embeded portion and making good distrubed ground on concrete , brick work, masonry etc and removing of demolished materials out side MD land complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description specifically provided for gates, staircase railings, framed truss etc complete all as specified and directed by Engineer-in-Charge.
M&L Mild framed works such as angles, tees , channels, etc as in fenching posts large and small gates and grills , gratings and chainlink fenching etc, including hanging gates in pillar with proper pintle hinges, stops, hand made sliding bolts ,etc complete all as specified and directed by Engineer-in-Charge.
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
Dismantling fencing wire mesh, any type complete all as specified & directed by Engineer-in-charge.
Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed by Engineer-in-charge. Note :-Fixing only chain link fencing, steel round bars for protection will measured and paid separately.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc including provision of binding wire complete as specified & directed by Engineer-in-charge. Note :-Supply only chain link fencing will measured and paid separately.
S & F for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confiorming to round bars Fe-410-W (Gde.E-250) quality A- or Fe 290 (Gde-E-165) complete all as specified & directed by Engineer-in-Charge.
S&F mild steel flat iron for securing of chain link fencing conforming to Fe 290 Gde E-165 in post and strut in fencing including fabrication i.e. cutting tops drilling holes notching for wire welding etc. complete all as specified & directed by Engineer-in-Charge.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 15cm but not.exc 22.5 cm long,diameter of neck n exc12 mm complete all as specified & directed by Engineer-in-Charge.
M&L for Preparation of new steel surfaces of any description over 10cm width or girth and application of two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified & directed by Engineer-in-Charge.
S&F steel rolling shutter (thickness of lath 1.25mm thick) without ball bearing as specified including top hood cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete push pull or manual type and including taking down existing rolling shutter of any thickness complete all as specified & directed by Engineer-in-charge.
S&F Steel rolling shutter (thickness of lath 1.25mm thick) without ball bearing as specified including top hood cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete gear operated type with bevel gear box and crank handle and including taking down existing rolling shutter of any thickness complete all as specified & directed by Engineer-in-charge.
S&F Ball bearing for rolling shutters of any description push pull type or gear operated type complete all as specified & directed by Engineer-in-charge.
M&L for 35mm thick precast cement concrete louvers and jallies type C-0 (1:3:6) using 12.50mm graded aggregate (measured solid), including all mouldings but excluding frame, set in cement mortar 1:4 including dismantling Trellis work (Jafri) one way, including taking as under of battens in trellis (posts and rails measured separately) complete all as specified and directed by Engineer-in-charge.
M& L for PCC 75mm thick type B0 1:3:6 (40mm graded stone aggregate laid in alternative as in plinth protection including finished the surface even and fair without using extra cement and filling the joints with mastic filling ie one part of bitumen 85/25 & 3 parts of sand by weight complete all as specified and directed by Engineer-in-charge.
S&F Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet/ semi corrugated 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws including dismantling (AC corrugated , semi corrugated etc) AC sheets in roof coverings complete all as specified & directed by Engineer in charge.
S &F Rolled sections Fe-410- W(Gde- E-250) quality- Bas in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified & directed by Engineer in charge.
Cleaning of septic tank, man holes and inspection chamber etc. by means of removing the silt, sludge, excreta etc. or other materials, manually or mechanically and depositing the same, where directed at a distance not exceeding 150m including excavation of pits of required size to accommodate the foul materials taken out from septic tank, manholes, soakage pits and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required and as directed by Engineer-in-Charge. Note for item No. 1.00 :- (i) Depth of silt, sludge, excreta, etc shall only be measured and paid. (ii) Dewatering/pumping out of foul water shall be measured and paid separately.
Pumping out foul water from soakage wells/septic tank mechanically and removing sludge of capacity 10 users complete all as directed by Engineer-in-charge.
---- ditto --- all as per item No. 33.00 above but 20 users
---- ditto --- all as per item No. 33.00 above but 50 users
---- ditto --- all as per item No. 33.00 above but 100 users
---- ditto --- all as per item No. 33.00 above but 250 users
Cleaning of choked sewage line of 100-200 mm bore of pipe including drains by rodding and well flushing with water, taking out waste materials any quantity and depositing where directed including covering the same with at least 30cm thick layer of soil all as directed by Engineer-in-Charge.
---- ditto --- all as per item No. 38.00 above but 250-600 mm bore sewage line
Cleaning of manholes not exceeding 1.5m deep by means of removing the silt, sludge, etc & bailing out foul water complete manually or mechanically and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required and as directed by Engineer-in-Charge.
Cleaning of manholes exceeding 1.5m but not exceeding 3m depth by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required and as directed by Engineer-in-Charge.
Pumping out of water / liquid from soak wells of any capacity or size and discharge the same to nallah / drains through hose pipe or by other means upto distance of 250 mtr. Including removing old brick bats/Slucisy material from the soak well and refilling the same after washing brick bats with water etc complete in all respect complete all as specified and directed by Engr-in-Charge.
Cleaning of floor trap, gully trap in any size by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Blockage of WC/EWC/Urinal/WHB in any type floor by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deep for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound in sealed pack complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick on stone masonry surface in cement mortar 1:4 including water proofing compound and finished even & smooth without using extra cement complete all as specified & directed by Engineer-in-charge. Note :-Supply only water proofing compound shall be measured and paid separately.
M&L for rendering 15 mm thick on stone masonry surfaces or surfaces other than fair faces of brick work or on one side of lathing in cement mortar 1:4 & finished the surface even & fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10 mm thick plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces of walls and finishing the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete reinforced of any description and in any position not other wise specifically provided and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm bore pipe complete all as specified and directed by Engineer-in-Charge.
--- ditto --- all as per item No. 55.00 above but of 200mm bore.
--- ditto --- all as per item No. 55.00 above but of 300mm bore.
M & L for 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars including demolition of existing pipes of any descriptioncomplete all as specified and directed by Engineer-in-Charge. Note :- Excavation and earth work shall be measured and paid separately.
M & L for 200mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars including demolition of existing pipes of any description complete all as specified and directed by Engineer-in-Charge. Note :- Excavation and earth work shall be measured and paid separately.
M & L for 300mm dia Reinforced concrete pipes, class N-3, laid and jointed complete with collars including demolition of existing pipes of any description complete all as specified and directed by Engineer-in-Charge. Note :- Excavation and earth work shall be measured and paid separately.
S&F in repair 100mm bore cast iron cowl (sand cast) all as specified & directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls and including taking down existing pipe of any description complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls and including taking down existing pipe of any description complete all as specified and directed by Engineer-in-Charge.
S&F in repair, 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F in repair, 125mm/110mm dia PVC (SWR) gully trap, setting & jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F in repair, PVC (SWR) bends of 75mm bore setting & jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F in repair, PVC (SWR) bends of 110mm bore setting & jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F in repair, PVC (SWR) cowl of 75mm bore setting & jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F in repair, PVC (SWR) cowl of 110mm bore setting & jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F 110mm PVC (SWR) WC connector with lip ring to fit WC outlet complete all as specified & directed by Engineer-in-charge.
M/S OM VISHNU ENGINEERING & CONSTRUCTION COMPANY
M/s Shri Inder Construction Company
JASOL MAA ENTERPRISES
BHAGWATI CONSTRUCTION
Leelashah Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .