Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.9 CrAdmitted-Finance | -16.84% | ₹4.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹5.2 Cr+₹25.5 L (5.18%)Admitted-Finance | -12.85% | ₹5.2 Cr+₹25.5 L (5.18%) | L2 | Admitted-Finance |
| 3 | L3₹5.2 Cr+₹31.3 L (6.35%)Admitted-Finance | -13.31% | ₹5.2 Cr+₹31.3 L (6.35%) | L3 | Admitted-Finance |
| 4 | L4₹5.3 Cr+₹40.3 L (8.18%)Admitted-Finance | -10.89% | ₹5.3 Cr+₹40.3 L (8.18%) | L4 | Admitted-Finance |
| 5 | L5₹5.5 Cr+₹61.6 L (12.5%)Admitted-Finance | -8.51% | ₹5.5 Cr+₹61.6 L (12.5%) | L5 | Admitted-Finance |
Tender Value
₹6 Cr
EMD Value
₹12 L
Closing Date
6 Jan 2020, 6:00 pmClosed
Project Director(Housing) RUDSICO
4-Sa-24, Jawahar Nagar, Jaipur-302004
Const. of Main building and outer development (Rain water harvesting, Internal road, Cycle shed, horticulture, outer electrification etc.) at ITI Campus, Gogunda (Udaipur)
2019_RUDSI_173027_1
NIT 06/2019-20 SN 01
Open Tender
Civil Works
Percentage
540 days
Gogunda (Udaipur)
Please refer Tender doucments
2 documents required · 2 mandatory
₹5,000
Executive Director, RUDSICO
₹12 L
Yes
9 Jan 2020
18 Dec 2019
7 Jan 2020
18 Dec 2019
6 Jan 2020
18 Dec 2019
Amount
Part I NON BSR Items
SITC of Solar Photo Voltaic Power Plant of 1 KW capacity at ITI Buidling with C-Si Module minimum 240Wp, Multi Crystalline silicon terrestrial high power solar cells shall be used in solar photo voltaic module as per IEC 61215/ IS: 14286 & IEC 61730- latest standard & each PV module must be 60 Cells and from reputed Indian manufacturer only. PV module must be warranted for output wattage which should not be less than 90% at the end of 10 years. The solar module shall have a front cover on high transmission (Greater than 91%) tempered and textured glass 3.2 mm thick with anodized aluminum alloy frame material to protect the silicon cells damage. The fill factor of module shall not be less than 0.70 modules alignment & tilt angle shall be calculated to provide the best annual energy output. Make: TATA BP , MOSERBAER ,BHEL,REIL, LANCO, TOPSUN, PV POWER, JAIN IRRIGATION, SUNGRACE, WAREE, CANDIAN SOLAR.
SITC OF Module Connector Pair suitable for standerd PV module matching with item no.1
SITC of Module Mounting Structure at ITI Building with as per following : The solar panel module mounting structure 12MMS shall be made of hot dipped galvanized MS angles and as per panel module size.all nut & bolts shall be of high quality stainless steel SS 304 Grade. The minimum clearance of the lowest part of module structure & ground level be designed to allow easy replacement of any module. The structure design and materials with any alternate option also can be considered but need to avail approval from our expert team for civil and structural engineering wing( the bidder should visit the site before qouting rates , no extra cost will be given for civil work after award of order and permission for grouting fastners at roof top will never be granted in any case )
SITC of 1 Core 4 Sq.mm Cu PVC / XLPE Cable Havell's, KEI, , Polycab
SITC of 3 Core 16 Sq.mm Cu XLPE Arm. Cable (AJB to MJB ) Havell's, KEI, , Polycab
SITC of 3.5 Core 150 Sq.mm Al XLPE Arm. Cable (AC DB To Metering Panel)Havell's, KEI, , Polycab
SITC of 3.5 Core 70 Sq.mm Al XLPE Arm. Cable (Metering panel To LT Bus Bar)Havell's, KEI, , Polycab
SITC of Solar Grid Connected Inverter 10KW-3-Ph AC O/P The Power conditioning unit Central inverter and shall be supplied as integrated of separate units. Maximum power point tracker (MPPT) shall be integrated into PCU & should be microprocessor/micro controller based to minimized power losses. The efficiency of MPPT shall not be less than 98% & should be suitably designed to meet array capacity. The encloser for PCU shall comply with IP 21 and suitable for indoor application. PCU shall be having provision of cooling with suitable fan. Local instrumentation shall be provided on PCU with standard protective device. The DC distribution board shall be provided in between PCU and solar array with suitable rating. The. The inverter is designed in such a way that it will synchronize with the utility (grid) power with respect to the voltage and frequency of Grid and it corrects itself according to he grid parameters within its settable limits. The inverter will sense the array power and grid power if both are available it starts and stops automatically in the morning and evening respectively. including PCU Accessories( Data Logging and Remote communication) and Communication cable and accessories as per site requirement. Supply & Instillation of PC for On line Monitoring of System performance and daily Generation output to be integrated with PCU. PC- Monitor - 19" TFT samsung, dell, HP with Intel Dual Core Processor , with RAM 4GB , hard disc 360 GB (dell, compaq,HP) and HP/ CANON Laser Black & white Printer with Min 1000 PPT. 01. Inverter: 10 KW 400V 02. Qty: 1 nos. 03. Automatic Start Up & Shut Down : Provided. 04. Inverter operation logic :- 05. (A) 1st Priority : Solar (B) 2rd Priority : Grid Make: SMA, Kaco,Delta, Sangrow .
P & F of custom built civil foundation work for mounting steel structure of solar PV module array ( as per item no. 3 of BOQ i.e. 20 nos. ) at ITI Roof. Height without any transportation system only through mannual labour . The work includes cost of cement mortar concrete and RCC frame , labour , finishing complete. the pillors made for supporting the struture may be of designed size as per site requirement.(CIVIL Foundation - The Size of Foundation 600MMX600MMX400MM so consider accordingly Approx 6 pillors for each structure)
SITC of AC Distribution Board / Metering Panel Required Standrad Powder Coated CRCA sheet Box with required size, 1 nos. MCCB 250 Amp 35 KA 4pole for incommer and 4 nos100 Amp 4 pole outgoing (all adjustable and of make Siemens, GE, L&T, Schneider ) MCCB , Digital Meter, LED indicator and Required accessories and detail drewing as provided by engineer in charge.
SITC of copper tube Lightning Arrestor
Supply & fiixing MS Cable tray Size ( 300mm x50mmx1.6mm) with GI Sheet Cover of 22 gaugae .
Supply & laying G.I Strip ( 32MMx6MM)
Supply & Fixing ISI marked (IS:13849) Portable Fire Exitnguisher, ABC type,finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of 10 KG capacity.
Installation and Fixing of LED solar Bollard lights , Solar panel : 4 Watt, Battery : 6V, 4.5Ah , LED : 12md ,height 2.5 feet post, Back up : 7-8 Hours including all labour & Fittings charges with two year defect liability
Supply & Installation of Solar street light (Including civil work as per attached drawing) – having MS powder coated body encases Solar PV panel poly-crystalline, comprising of Lithium battery with in-built BMS, high brightness LED light, driver efficiency more than 90%, High efficiency charge controller with automatic dimming functionality (with 12m PIR motion sensor) compliant to IP-65 automatic Dusk to Dawn operation, working temperature 0 C to 55C, with battery overcharging and battery deep discharging protection. Indications should include GREEN LED for battery charging and RED LED for battery low (one blink every 2 second) and Solar panel dirty indication (two blinks every 2 second). Light should be properly packed in Litlon (1 inch thick or better) to avoid any damage during transit 12Watt LED Material: Aluminium Alloy Solar Panel: Monocrystalline, Max Power 18V/35W LED Power: Bridgelux 12W Battery : Li ion 14Ah Lumens : 1360 - 1560 , View angle- 120⁰ Install Height : 4 - 6m Charge time : 6 - 8 hours Discharge time : 8 - 12 hours Backup : 2 - 3 days warranty period : - One year onsite Warranty
Providing and fixing 40mm thick sand stone with embossing approved design letters, logo minimum 20 mm thik
Providing And fixing Glow back light Sign Board of aprroved design and size.
Providing fixing S.S steel name plates of approved design and logos directions complete
designing or naming Painting charges on wall or surface as per approved design including all material .
Supply and fixing Water cooler Stainless steel IS 304 of 80 litre capacity, auto shut off, stand with inbuilt R.O system, all fixtures complete. Make -Blue star, USHA or as approved by Engineer in charge.
Providing and fixing superior grade Green/white acadamic Class room board or as approved by engineer in charge.
Aakar Constructions
M/s. Ganesh Narayan Sharma, Jaipur
Girraj const. co.
M/s Radheyshyam Bhalla
M/s Hawamahal Construction
M/s Hawamahal Construction
M/s. Ganesh Narayan Sharma, Jaipur
Girraj const. co.
Aakar Constructions
M/s Radheyshyam Bhalla
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
Tendernotice_2.pdf
PDF • 4.02 MB
TB_Gogunda.pdf
Tender Documents • 0.88 MB
Gschedule_Gogunda.pdf
Tender Documents • 0.49 MB
BOQ_304500.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .