Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹23.5 L
EMD Value
₹23,500
Closing Date
4 Dec 2026, 2:00 pm7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Superintending Engineer
Superintending Engineer, E.U.D.C.-1, 57, George Town, Prayagraj
Refer to Tender Description
2026_PVVNV_1210819_1
70/SE/EUDC-I-PRA/2026-27
Open Tender
Electrical Works
Lump-sum
180 days
EUDD, Naini Prayagraj
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Account Number-0012002100504911
₹23,500
20 Nov 2026
20 Nov 2026
4 Dec 2026
20 Nov 2026
4 Dec 2026
20 Nov 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | Shifting of 33 Kv Line of Trivenipuram, New Jhunsi & Ustapur Mahmoodabad Feeder Due to Construction of Low Height Subway (LHS) by Indian Railways Under Jurisdiction of Executive Engineer, E.U.D.D. Naini, Prayagraj. | - | - | - | - |
| 1 | Carriage, Erection and vertical installation of double pole structure using 13/11-meter long Steel Tubular Poles (STP) for 1 Work includes excavation of pits, grouting, Earthing, Muffing, plinthing with cement concrete mix (1:4:8), painting and firm erection of poles in line with UPPCL standard construction drawings. The scope further includes supply & installation of all requisite components such as MS top channel (125x65x2240 mm), MS Channel T-off (125x65x1300mm),MS Channel Dropper (100x50x2028 mm), pin insulators with GI pins, Disc Insulator as per requirements, MS bracing angles, GI clamps, base clamps, stone pad, nut Barbed wire with danger board and number plate at each Pole. All associated hardware like GI nuts & bolts, washers, fuse wire (HT & LT side of required size) and welding where necessary will be arranged and installed by the contractor only ST Pole will be provided by department. The work shall comply with REC construction practices, UPPCL technical standards, and all site-specific requirements ensuring complete structural and electrical safety. | 3 | No. | - | - |
| 2 | Carriage, Erection and vertical installation of Four pole structure using 13/11-meter long Steel Tubular Poles (STP) for 1 Work includes excavation of pits, grouting, Earthing, Muffing, plinthing with cement concrete mix (1:4:8), painting and firm erection of poles in line with UPPCL standard construction drawings. The scope further includes supply & installation of all requisite components such as MS top channel (125x65x2240 mm), MS Channel T-off (125x65x1300mm),MS Channel Dropper (100x50x2028 mm), pin insulators with GI pins, Disc Insulator as per requirements, MS bracing angles, GI clamps, base clamps, stone pad, nut and bolts, Barbed wire with danger board and number plate at each Pole. All associated hardware like GI nuts & bolts, washers, fuse wire (HT & LT side of required size) and welding where necessary will be arranged and installed by the contractor only ST Pole will be provided by department. The work shall comply with REC construction practices, UPPCL technical standards, and all site-specific requirements ensuring complete structural and electrical safety. | 1 | No. | - | - |
| 3 | Supply, fabrication, and erection of protective cradle guarding for 33 kV overhead line at road/line crossings as per REC Construction Standard M-6 and UPPCL norms, comprising 7/3.15 mm/7/4.00 mm HDG steel bearer wires, 8 SWG GI cross-lacing wires, galvanized MS channel cross-arms (100×50×6 mm), turnbuckles, clamps, and continuous earthing bonded to pole earth electrodes at both ends, complete in all respects. (all required material will be provided by the contractor) | 500 | Mtr. | - | - |
| 4 | Erection & grouting of stay Rod with Cement, Sand and Bricks ballast in ratio 1:4:8 and fastening the stay wire with pole and stay rod nuzzling. (all required material including Stay set will be provided by the contractor) | 10 | No. | - | - |
| 5 | Laying of 33 kV 3x300 sq. mm XLPE cable by Horizontal Directional Drilling (HDD) method with HDPE Pipe & Installation of Cable Route Markers. (Only 33 kV 3x300 sq. mm XLPE cable provided by the department and HDPE pipe of PN6 PE80, Dia 160 mm with clamp and all other material will be provided by the contractor). The entire work must be executed in accordance with UPPCL technical standards and REC construction guidelines for 33 kV Cable installations. | 1,100 | Mtr. | - | - |
| 6 | Hanging of 33 KV XLPE cable of size 3x300 sq.mm (as per site condition) on existing or newly constructed 13/11 Meter long STP pole. The cable shall be fixed using stay wire and MS stay clamps suitable for the respective pole type, ensuring secure anchoring and maintaining standard clearance. Stay clamps with GI bolts, nuts, and washers shall be arranged and installed by the contractor only. 33 KV XLPE cable of size 3x300 sq. mm and stay wire will be provided by department. Cable alignment shall be straight and sag-free, and all bends shall follow minimum bending radius norms as per IS:1255. The contractor shall ensure mechanical protection, tagging, and safety precautions throughout the execution. Work shall be carried out in accordance with UPPCL specifications and REC construction guidelines. | 100 | Mtr. | - | - |
| 7 | Fixing of 33 kV heat shrinkable type cable termination kits for XLPE insulated 3-core 3x300 sq.mm aluminum conductor cable. Kits shall conform to VDE-0278 / IEEE-48-1975 /IS:13573-1992 / ESI STD 09-13 and other relevant international standards. The scope includes preparation of cable ends, crimping of lugs, and application of stress control tubing, insulation sleeves, earthing arrangement, anti-tracking components, and final sealing. End Termination kits of Raychem/3M shall be installed complete with all necessary accessories and testing in accordance with UPPCL norms. The contractor shall supply the jointing kits with a minimum guarantee period of 2 years from the date of ERP measurement. All materials including lugs, sealing components, jointing kits, and tools shall be arranged by the contractor. | 12 | No. | - | - |
| 8 | Fixing of 33 kV heat shrinkable type straight-through jointing kits for XLPE insulated 3-core 3x300 sq.mm aluminum conductor cable. Kits shall conform to VDE-0278 / IEEE-48-1975 / IS:13573-1992 / ESI STD 09-13 and other relevant international standards. The scope includes preparation of cable ends, crimping of lugs, application of stress control tubing, insulation sleeves, earthing arrangement, anti-tracking components, and final sealing. Straight-through kits of Raychem/3M shall be installed complete with all necessary accessories and testing in accordance with UPPCL norms. The contractor shall supply the jointing kits with a minimum guarantee period of 2 years from the date of ERP measurement. All materials including lugs, sealing components, straight-through jointing kits, and tools shall be arranged by the contractor. | 2 | No. | - | - |
| 9 | Hosting of 33 kV, 3x300 sq.mm XLPE insulated HT cable on single pole support using a 3 Meter long, 6-inch diameter G.I. pipe (Class B), ensuring mechanical protection and safe routing of the cable. The work includes securely clamping the G.I. pipe to the pole using galvanized iron clamps with nuts, bolts, and washers. Scope also includes proper jumpering of the cable from pipe exit to terminal point using aluminum lugs and insulated crimping. All required materials including aluminum lugs, G.I. pipe, mounting clamps, nuts, bolts, and all fastening accessories shall be arranged and installed by the contractor. The entire work must be executed in accordance with UPPCL technical standards and REC construction guidelines for 33 kV installations. | 12 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
T-No-70 Railway 33 Kv Line Shifting.docx
Tender Documents • 0.13 MB
BOQ_2300577.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .