| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹14.1 L+₹1.6 L (12.4%)Rejected-Finance | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹14.1 L+₹1.6 L (12.5%)Rejected-Finance | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | L4₹14.2 L+₹1.6 L (12.9%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical As per WLR Earnest money not uploaded as per NIT and being unenlisted Earnest money required to be deposited |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
28 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
8600REPAIR AND MAINT OF COOLING AND HEATING APPLIANCES WITH CONNECTED ITEMS IN WEST AREA UNDER GE M AF JALAHALLI
2021_MES_479156_1
8600/E8
Open Tender
Electrical and Maintenance Works
Item Rate
242 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT PUBLIC FUND ACCOUNT
₹32,000
7 Dec 2021
1 Oct 2021
30 Oct 2021
1 Oct 2021
28 Oct 2021
16 Oct 2021
1 Oct 2021 - 8 Oct 2021
60 days
Amount
Material and labour for servicing/cleaning of complete indoor and out door unit of Split Type Air conditioner of 1.0/1.5 TR capacity by means of adding cleaning solution with water. The cleaning of the condensor and chiller tubes shall be done with use of nylon brushes till the scaling is removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition and specified and as directed by Engineer-in-Charge. Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch 'A'.
All as per item no.-1 but here-in-before for Split Type Air conditioner 2.0 TR capacity.
All as per item no.-1 but here-in-before for Window Type Air conditioner 2.0 TR capacity.
Material and labour for servicing / cleaning of complete Water cooler/ Deep freezer of upto 400 Ltr capacity by cleaning the outer side by means adding cleaning solution with water. The cleaning of condensor and chiller tubes is done with use of nylon brushes till the scaling is removed for water cooler & deep freezer the inner tank should be cleaned using bleaching powder and keeping the inner tank clean from bacterial and descaling and ensuring its serviceability all as specified and as directed by Engineer-in-Charge. Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch 'A'.
All as per item no.-4 but here-in-before for Refrigerator upto 340 Ltr capacity .
Material and labour for Taking out unserviceable Receprocating type compressor of Split Type AC 1.5 Ton capacity, from site and replace and refixing with new reciprocating compressor sealed unit in position including with checking Pressure testing / leak arresting , vaccumising with dry nitrogen gas/ oil charging and recharging of refrigerant gas R-22a of required quantity, bracing of discharge and suction line for Split AC 1.5 TR any make serviceable including replacing the unserviceable strainers and capillary tubes, additinal inner/outer copper tubing and all connected accessories as per site require, leak testing, transportation for workshop and after repair of existing complete all as directed by the Engineer-in-charge.
All as per item no-7 above but here-in-before for Split Type AC 2 Ton capacity
Material and labour Taking out unserviceable Rotary type compressor of Split Type AC 1.5 Ton capacity, from site and replace and refixing with new rotary type compressor sealed unit in position including with checking Pressure testing / leak arresting , vaccumising with dry nitrogen gas / oil charging and recharging of refrigerant gas R-22a of required quantity, bracing of discharge and suction line for Split AC 1.5 TR any make serviceable including replacing the unserviceable strainers and capillary tubes, inner /outer additional copper tubing and all connected accessories as per site require leak testing, transportation for workshop and after repair of existing complete all as directed by the Engineer-in-charge.
All as per item No-9 above but here-in-before for Split Type AC 2 Ton capacity
Material and labour for Taking out unserviceable Reciprocating/Rotary type compressor of Window Type AC 1.5/2.0TR Ton capacity, from site and replace and refixing with new rotary type compressor sealed unit in position including with checking Pressure testing / leak arresting , vaccumising with dry nitrogen gas / oil charging and recharging of refrigerant gas R-22a/ 134a of required quantity, bracing of discharge and suction line for window type AC 1.5 TR any make serviceable including replacing the unserviceable strainers and capillary tubes, additional inner/ outer copper tubing and all connected accessories as per site require leak testing, transportation for workshop and after repair of existing complete all as directed by the Engineer-in-charge.
All as per item no.-11 above but here-in-before for Water cooler of any make and capacity
All as per item no.-11 above but here-in-before for Refrigerator of any make and capacity
All as per item no.-11 above but here-in-before for Deep freezer of any make and capacity.
Material and labour for Gas charging with 134a for Refrigerator and Water coolers in position including leak testing to achieve desired suction pressure and temperature (or any other cooling applainces also)
Material and labour for Gas charging with R-22a for split type AC in position including leak testing to achieve desired suction pressure and temperature (or any other cooling applainces also)
Supply and fixing Condenser blower motor for Outdoor Split type type AC 1.5 / 2 TR capacity.
Supply and fixing Condenser blower motor of water cooler / deep freezer of any capacity, make and model
Supply and fixing Blower motor of indoor unit of split AC 1.5/2TR.
Supply and fixing out door unit of Split AC of capacity 1.5 TR .
Supply and fixing out door unit of Split AC of capacity 2.0 TR .
Supply and fixing Fan Blade suitable for 1.5 / 2 Ton Split Type Air conditioner
Supply and fixing Fan Blade suitable for Water Cooler of any capacity / Make
Supply and fixing thermostat for water cooler / refrigerator / deep freezer / Window type ACs of any capacity and make.
Supply and fixing relay for any type of AC / water cooler /refrigerator/deep freezer of any capacity & make.
Supply and fixing OLP for any type of A/C/water cooler /refrigerator/deep freezer of any capacity & make.
Supply and fixing PCB suitable for split /window type A/C 2/1.5 TR of any make.
Supply and fixing wiring kit suitable for split type A/C 2/1.5 TR of any make.
Supply and fixing wiring kit suitable for water cooler/refrigerator/deepfreezer /Window type ACs of any capacity and make.
Supply and fixing starting capacitor 80/ 100 mfd for airconditioner .
Supply and fixing starting capacitor 120 mfd for airconditioner .
Supply and fixing Running capacitor 45 mfd for Split type Air conditioner 1.5 Ton Capacity
Supply and fixing Running Capacitor capacitor 60 mfd for Air conditioner 2 Ton Capacity
Supply and fixing Running capacitor 36 mfd for air conditioner of any capacity & water cooler of any capacity
Supply and fixing auto swing motor for inside unit of split A/C of capacity 2/1.5 TR of any make
Supply and fixing remote control system of split / window type A/C of capacity 2/1.5 TR .
Supply and fixing PVC air filter for split type A/C of any capacity & make .
Supply and fixing contactor suitable for 2/1.5 TR of any make
Supply and fixing Brass angle valve 5/8 inch for split AC 1.5/2TR capacity.
Supply and fixing Brass angle valve 3/8 inch for split AC 1.5/2TR capacity.
Supply and fixing Copper tubing 5/8" dia for extending refrigerant piping including brazing/adopter and accessories.
Supply and fixing Copper tubing 3/8" dia for extending refrigerant piping including brazing/adopter and accessories.
Supply and fixing Puff insulation to suction pipe of split AC.
Supply and fixing Bi-metal for refrigerator
Supply and fixing timer for refrigerator
Supply and fixing PVC ball valves,float valve for water cooler of any capacity & make
Supply and fixing brass chromium plated push button tap outer/Inner thread suitable for water cooler of any type of size 15 mm complete .
Supply and fixing PCB suitable for capacity upto 5 KVA Voltage stabiliser
Supply and fixing Transformer Suitable for up to capacity 5 KVA Voltage stabiliser
Supply and fixing door lock for refrigerator/Deep freezer any capacity
Supply and fixing baffle tray for refrigerator any capacity
Supply and fixing crisper tray for refrigerator any capacity
Supply and fixing condensor coil for 1.5 Ton Split AC
Supply and fixing condensor coil for 2.0 Ton Split AC
Supply and fixing condensor coil for refrigerator of any capacity
Supply and fixing Evaporator coil for refrigerator of any capacity
Supply and fixing indoor unit for 1.5 Ton Split AC.
Supply and fixing indoor unit for 2.0 Ton Split AC.
Supply and fixing plug top 15 Amp,3 pin conforming to revent IS.
Supply and fixing plug top 5 Amp,3 pin conforming to revent IS.
Material and labour for replacement Water heater coil of geyser 25/50 ltr capacity, any type, any make , of 1.5 KW all as per existing make / model / size conforming to relevant IS and make serviceable with replacing worn-out fasteners and defective components and testing, transportation etc including taking down the geysers and refixing the same after repairs complete all as specified and directed by Engineer -in-Charge.
All as per item no.-60 above but here-in-before for 2.0 KW any type
Supply and fixing thermostat for any type /make/capacity of Geyser/ solar Water heater.
Supply and fixing water inlet & outlet assembly of any type /make of geyser 50 Ltrs capacity complete. .
All as per item no.-63 above but here-in-before for 25 Ltrs capacity complete.
Supply and fixing pressure release valve 15mm dia with new one for any type /make/capacity of geyser .
Supply and fixing PVC flexible connection of 15mm dia with check with new one suitable for cold/hot water connection of geysers
Material and labour for GI tubing 15mm dia medium grade in short length with all fittings complete to walls, or laid on roofs including taking down existing unserviceable pipes.
Supply and fixing stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends with iron pipes of 15mm bore and washers etc including taking down existing unserviceable stop valves complete
Supply and fixing 20 mm Non return valves, cast copper alloy, for GI Pipes pipe all as directed
Material and labour for Taking the copper or steel container carefully from the geyser, of capacity 25/50 Ltrs descaling, rectifying leakage by braising, resetting the insulating (glass wool), testing for the required pressure replacing rubber gaskets, worn-out fasteners etc. and re-fixing with new copper geyser tank as per site require and make serviceable complete all as directed by Engineer in charge.
Material and labour for Removing & Taking down Solar water heater of any type & make and capacity, after disconnecting the electric and water connections plugging the inlet and outlet as required at the building , repairing the solar water heater by removing unservicable parts such as , thermostat,heating element, pressure release valves, rubber gaskets,inlet/outlet connections ,testing for the required pressure, refixing the same in position with nuts and washers after make serviceable condition complete all as directed by engineer in charge.
Material and labour for PVC insulated copper cable flexible 3 core of size 2.5 sq mm. rubber insulated
Material and labour for PVC insulated copper cable flexible 3 core of size 4 sq mm. rubber insulated
Supply and fixing heating element 3 KW, 230V for solar water heater for 200 LPD capacity
All as per item no.-74but here-in-before for 2 KW, 230V for solar water heater for 100 LPD
Supply and fixing Toughened glass 1010 x 2020 x 5 mm including taking down old / broken toughned glass carefully bydisconnecting all connections and make serviceable complete all as directed.
Material and labour for Cleaning of storage tank of solar water heaters of any capacity in position with liquid soap solution, flushing with fresh potable water, sweeping with clean dry cloth and make serviceable after resetting of float valve to maintain the correct level of water in the tank and writting the date of tank cleaning clearly in white letters all as specified by Engineer in charge.
Supply and fixing MCB Single pole, 240 volts 6 to 32 Amps 10 KA rupturing capacity for Acs and Geysers of various ratings.
Supply and fixing base plate of Geyser/Water Heater with flange with nut-bolt and washer of 25 / 50 Ltrs Capacity all as directed
Supply and fixing Indicator Lamp of RED / GREEN Suitable for Water Heater/Geyser
Supply and fixing of Single pole and neutral Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps, 240 Volts, AC,50 HZ, completete all as directed and specified, including taking down old unserviceable plug socket and taken for schedule of credit.complete all as specified and directed.
Supply and fixing of Solar collector panel of any capacity of solar water heater complete.
Supply and fixing of Annode rods for any capacity of solar water heater complete.
Supply and fixing of Rubber pipe for any capacity of solar water heater complete.
Supply and fixing Copper washer for any capacity of solar water heater.
Material and labour for GI tubing 20mm dia medium grade in short length with all fittings complete to walls, or laid on roofs including taking down existing unserviceable pipes.
Repair/Maintenance of isolation stabiliser three phase of capacity 05 KVA and dismantling of existing burnt copper winding with insulation and rewinding with existing transformer and re-fixing, testing complete all as specified and directede . Note:- Cost of all required spare parts for making fully function of isolation stabilzer are deemed included to included in quoted rates of items
Repair/Maintenance of isolation stabiliser three phase of capacity 10 KVA and dismantling of existing burnt copper winding with insulation and rewinding with existing transformer and re-fixing, testing complete all as specified and directede . Note:- Cost of all required spare parts for making fully function of isolation stabilzer are deemed included to included in quoted rates of items
JM Engineering
PLATINUM CONSTRUCTIONS
ANAND REFRIGERATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .