Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC NEAR SWAMI SAMARTH MANDIR GROUND FLOOR 28 1 1 D SHIVRAJ NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | L1 | Accepted-AOC AWARDED AS LOWEST BIDDER | |
| 2 | L2₹22.4 L+₹2.5 L (12.6%)Rejected-AOC | L2 | Rejected-AOC SECOND LOWEST BIDDER (L2) | |
| 3 | L3₹23.0 L+₹3.1 L (15.6%)Rejected-AOC | L3 | Rejected-AOC THIRD LOWEST BIDDER (L3) | |
| 4 | L4₹27.2 L+₹7.3 L (36.6%)Rejected-AOC | L4 | Rejected-AOC FOURTH LOWEST BIDDER (L4) | |
| 5 | L5₹27.3 L+₹7.4 L (37.2%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L5 | Rejected-AOC FIFTH LOWEST BIDDER (L5) |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
7 Dec 2023, 6:00 pmClosed
GERD PASHAN PUNE
GERD PASHAN PUNE
REPAIR TO VARIOUS UTILITY SERVICES INCLUDING INTERNAL AND EXTERNAL ELECTRIFICATION AND OTHER CONNECTED WORK AT NMRL AMBERNATH
2023_MES_628577_1
GERD/PSN/TOKEN/39 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
9 documents required · 9 mandatory
₹500
GERD PASHAN PUNE
₹54,000
Yes
16 Jan 2024
16 Nov 2023
9 Dec 2023
16 Nov 2023
7 Dec 2023
30 Nov 2023
16 Nov 2023 - 23 Nov 2023
Amount
Taking down cement plaster on brick/ concret surfaces and removing debris from site complete all as specified and as directed by Engr-in-Charge.
supply and Fix in repair PVC inslated unsheathed copper cable 1.5 sqmm x3 core from pole junction box to street light complete all as specfied and directed.
Supply, install, testing in repair Automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of Natual light the sensor along with and including suitable power contactor made MCB and support terminals to be enclosed in pole/ wall mountable , enclouser made of rust proof electric shock proof, termite proof and FR grade special moulding compound SMC Junction box confirming to Ip 54 class protection the contactor/Relay, MCB complete control wiring to take enough load 12 KW load equally distributed over 3 phase contactor rating 40 amps4 pole and MCB complete all as specfied and directed.
Supply and Fix in repair Polymer based dropout fuse unit complete set suitable and including for 22 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning all as per the directions of Engr-in-charge.
Material and labour for straight through joint kit,heat shrinkable,type,for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core, upto 185 sqmm, 22 KV comple all as specfied and directed by Engineer-in-charge.
Material and labour for outdoor type end termination joint kit, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, 185 sqmm, 22 KV complete all as specfied and directed. by Engr-in-charge.
Material and labour for Indoor type end termination joint kit, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, 185 sqmm, 22 KV complete all as specfied and directed by Engr-in-charge.
Material and labour for indoor type22KV Touch proof termination joint kit heat shrinkable, type for in RMU unit cable connection including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core,upto 185 sqmm, 22 KV complete all as specfied and directed by Engr-in-charge. Note: The rate shall be including permision of MSEDCL Replacing Touch proof in RMU.
supply and fix GI strip of size 32x6mm size from Earth pit to RMU/VCB/ LT panel connected continuty earthing complete all as specfied and directed.
Excavation in trenches in hard dense soil not exceeding 1.5 meter wide and not exceeding 1.5 metre deep for taking out/laying of HT/ LT under ground cable and getting out complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50 meter depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed.
Material and labour for dry crushed stone sand filling in trenches to required width at bottom and top of cable as in cushioning including spreading leveling and consolidation complete all as specified directed. Note : Punned thickness shall only be measured and paid.
Supplying and laying Bricks; common burnt clay building bricks, sub-class 'B’ for cable protection complete all as specified and directed by the Engr-in-Charge.
Material and labour for 150 mm dia RCC pipe class NP-2 with collors, complete, fixed laid in trenches for cable protection complete all as specified and directed NOTE :-(Excavation and earth work where required shall be measured and paid separately).
On load filteration of transformer oil by continuous circulation of transformer oil through mechanical filters to achive the desired dielectric strength of 35 KV for one minute at 4 mm gap complete all as specified and directed. Note: 1.Oil samples are to collected from top and bottom of oil tank and test results to be recorded for each sample before and after filteration.
Supply and topping up transformer oil of dielectric strength 50 KV at 4 mm gap of sphere at transformers of various capacity installed in various locations complete all as specified and directed. Notes : (a) New Transformer oil will be filled in the transformer only after filteration and dehydration of existing transformer oil of the transformer. (b) Transformer oil shall be supplied in sealed barrel with test result and test certificate. Make of Transformer oil: Savitha/ Mech/ Gandhar/ Power oil
Material and labour for preparation of old painted steel surface of 6 pole structure HTsteel tublar poles 11 mtr long above GL/coping including cross arms,channels,Flat iron,Clamps in LT/HT OH line by scraping with wire brush/ sand paper and applying one coat of aluminium paint including writing pole number with synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of old painted steel surface of LT steel tublar poles 8.5/9 mtr long above GL/coping including cross arms,channels,Flat iron,Clamps in LT OH line by scraping with wire brush/ sand paper and applying one coat of aluminium paint including writing pole number with synthetic enamel paint complete all as specified and directed.
Disconnecting the platform mounted indoor/outdoor type transformer of capacity 250 to 315 KVA situated at various sub station 22/ 0.433 KV 3 phase under NMRLarea of any make and transporting to workshop for repairs/ rewinding. Dismantling the transformer and accessories, drain out insulating oil, taking out the core assembly, taking out the defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/LT coil with existing guage of copper super enamelled wire/ copper strip of existing size, providing new insulation, sleeves for outlet connections including tap changer switch connection on all 3 phase, opening the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning. The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop complete all as specified and directed Notes : (i) Copper winding wire/strip will be measured and paid separately as supply only. (ii) Insulating oil for topping up will be measured and paid separately. (iii) Transportation of transformer for repair and re-installation including connection on HT & LT side, testing and commissioning is deemed to included in quoted rates. Spares which are required to be renewed shall be measured and paid separately as " supply only".
Supply only super enamelled copper winding wire of various gauges or existing specifications for repair and rewinding of transformers HT coil with insulation including necessary class of insulation complete all as specified and directed.
Supply only DPC copper strip of various gauges or existing specifications for repair and rewinding of transformers LT coil with insulation including necessary class of insulation complete all as specified and directed.
Disconnecting the transformer outdoor type from HT/ LT system carefully lifting by crane, shifting one place to another place with in 2 KM radius refixing and connecting HT/LT side for charging transformer 250 KVA complete and tested on available electric load complete all as specified and directed.
Supply only LT bushings with brass studs suitable for existing specification complete all as specified and directed.
Supply only gasket set complete to transformer all as specified and directed.
Supply only oil level indicator set complete all as specified and directed.
supply only breather assembly complete all as specified and directed.
Supply only HT bushing with stud 22 KV of existing specification complete all as specified and directed.
Material and labour for servicing, opening, draw out HT Breakers complete from its position and thorough inspection of complete opearating mechnical system, electrical system of AC/DC and complete mechanical repair of breakers including cleaning, oiling and greasing to all spares, Checking by draw out mechanism/arrangement of HT breakers and inspection of isolating Contacts, and decarburizing the male /female contacts, jaws complete and Checking of alignment with spout and setting of contact gaps including disconnecting and making HT incoming/ Outgoing connections complete all as specified and directed. Note :- (i) Removal of moisture from breaker by using vaccum cleaner and heating arrangement deemed to be included in quoted rate (ii) Major spare parts are to be paid separately under supply only items here in after, however cost of minor spares shall be deemed to be included in the rate quoted.
(a) Supply only Control contactor complete all as specified and directed.
(b) Supply only Control terminals complete all as specified and directed.
(c) Supply only Tripping Coil 30V DC complete all as specified and directed.
(d) Supply only Control switches complete all as specified and directed
Supply and Fix in repair MCCB 4 Pole, 415 V,with adjustable thermal magnetic release, 400 Amps with breaking capacity 36 KA, overload and short circuit protection including spreader terminals and Rotary Handles complete all as specified and directed.
Supply and Fix in repair MCCB 4 Pole, 415 V,with adjustable thermal magnetic release, 250 Amps with breaking capacity 35 KA, overload and short circuit protection including spreader terminals and Rotary Handlescomplete complete all as specified and directed.
supply and fix in repair flame proof switch socket combination suitable for 2P+ E 16 Amps 230 volt incuding plug top LM-6 mateials CMRI test certicate complete all as specified and directed.
Supply and fix in repair flame proof switch socket combination suitable for 4P+ E 32 Amps 430 volt incuding plug top LM-6 mateials CMRI test certicate complete all as specified and directed.
Suppy and fix in repair flame proof LM -6 Rotary On/Off switch 16 Amp, SP complete all as specified and directed
Material and labour for cutting of existing roads/ plinth up to 30 cm wide and 30 cm in depth for removal/ laying of pipe complete all as specified and directed.
Material and labour for PCC 1:4:8 type D-2 by using 40 mm graded crushed stone aggregate as in filling of road/ plinth cuttings and making good disturbed surface complete all as specified and directed.
Material and labour for PCC 1:3:6 type C-2 by using 40 mm graded crushed stone aggregate as in foundations of Poles and making good disturbed surface complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-2 by using 40 mm graded crushed stone aggregate as in foundations of Poles and making good disturbed surface complete all as specified and directed.
Material and labour for spreading stone aggregates/hard core of gauage not exc 25mm, deposited, spreading and leveling in layers not exc 15 cm thick including leveling and ramming to true surface complete all Specified and as directed by Engr in Charge.
Supply and fix in repair air termination single pointed aluminium rod of 12 mm dia 300 mm long fixed to aluminium strip 25 x 3 mm including drilling holes, nuts, bolts washers for resting/ supporting of air terminals etc.,complete all as specified and directed. Note : (i) Epoxy base insulator and PCC block only will be measured and paid separately (ii) Unit rate quoted is deemed to be inclusive cost of one lead joint and 2 Nos GI nuts, bolts washers, screws and necessary T&P and machining work required at site. (iii) Quated Rate is deeemed to include for site clearance including removing hurbs/ shrub and trimming of tree where ever required. (iv) Rate quoted shall also deemed include for working in any height i.e lighting protection of admin building NMRL and All safety equipment and risk cover of man power deployed and nothing extra shall be admissible.
Taking down / dismantling existing perished aluminium strip of size 25 x 3.15 mm from any height of roof top / on walls of conventional type lightening protection network system complete all as specifiec and as directed.
Re-fixing of serviceable aluminium strip of size 25 x 3.15 mm obtained from sl item No 45 above at any type of building/ magzine/ lab at any height on walls and jointing the system of conventional type lightening protection network and making good the disturbed surface of walls / roof top to match with existing surface complete all as specified and as directed.
Material and labour for aluminium strip of size 25x3.15 mm fixed on wall on insulator and PCC block with epoxy based insulator of 35mm size at distance / interval not more than 1.0 metre for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut and bolt, gutties, screws etc complete all as specified and directed. Note: PCC Block work, Insulator will be measured and paid separetly
Supply and fix PCC block of size 150x150x150mm in PCC 1:3:6 Type C1 with 20mm graded aggregate for fixing on roof conductor / air terminal rod / GI Strip etc complete all as specified and directed by Engr-in-charge
Material and labour for epoxy base insulator of suitable size 35 mm height fixed on PCC blocks / on wall on MS angle / on towers with and including nut bolts and washers etc complete all as specified and directed by Engineer-in-Charge
Taking down / dismantling existing perished GI strip of size 32 x 6 mm from walls / buried in to ground of conventional type lightening protection network system complete all as specified and as directed.
Re-Fixing serviceable GI strip of size 32 x 6 mm as obtained from sl item No 50 above, at any type of building/ magzine/ lab at any height including any type on walls and jointing the system of conventional type lightening protection network and making good the disturbed surface of walls / roof top to match with existing surface complete all as specified and as directed.
All as per Ser item 47 above but GI strip of size 32 x 6 mm
Material and labour for disconnecting and taking down old unserviceable point wiring any type and any conduit alongwith accessories switches, switch sockets, ceiling rose, switch board and main switch board etc., complete and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge
Material and labour for point wiring with 1.5 Sqmm size, PVC insulated and unsheathed 1100 volts grade single core multistrand copper conductor FRLS cable drawn into & including PVC casing capping of suitable size with all fittings and accessories with PVC box fixed with CP screws and cup washers for mounting fitting like switches, sockets and fan regulators etc; including one contineous run of PVC insulated green colour 1.5 sq mm multi stranded copper conductor cable earth wire and connected to common earth dolly for one light /fan point controlled by one; one way switch complete all as specified and directed .
Material and labour for point wiring with 1.5 Sqmm size, PVC insulated and unsheathed 1100 volts grade single core multistrand copper conductor FRLS cable drawn into & including PVC conduit of size not less than 19mm dia with all fittings and accessories with PVC box fixed with CP screws and cup washers for mounting fitting like switches, sockets and fan regulators etc; including one continous run of PVC insulated green colour 1.5 sq mm multi stranded copper conductor cable earth wire and connected to common earth dolly complete all as specified and directed for the following :- (a) one light /fan point controlled by one; one way switch.
(b) one 3 pin socket out let 5 Amp on independent point.
(c) one 3 pin socket out let 5 amp point on the same board with other switches.
All as per Ser item 55 above but with 2.5sq mm size pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board including one continuos run of PVC insulated green in colour 2.5 sqmm multistranded copper conductor earth wire connecting to earth dolly complete all as specified and directed.
Supply and fix Modular socket 2/3pin complete all as specified and directed.
Supply and fix Modular Switch 1Way 10Amps complete all as specified and directed
Supply and fix Modular Fan Regulator 120w complete all as specified and directed
Supply and fix Modular Metal box 3 module complete all as specified and directed
Supply and fix Modular Metal box 4 module complete all as specified and directed
Supply and fix Modular Metal box 6 module complete all as specified and directed
Supply and fix Modular cover Plate with frame 3 Module complete all as specified and directed
Supply and fix Modular cover Plate with frame 4 Module complete all as specified and directed
Supply and fix Modular cover Plate with frame 6 Module complete all as specified and directed
Supply and fix in repair 36 watt 2x2 LED edge light fitting suitable for Armstrong celing complete all as specified and directed.
supply only LED 20 watt 4 feet tube rod complete all as specified and as directed.
Taking down existing unserviceable Flame proof tube light fitting 2x36 watt fixed on wall/ celing at any hight carring out necessary repairs cleanning of cover and glass repair interal wiring and holder for fixing LED retrofitt tube light and refixing to the position complete all as specified and directed by Engg in charge.
Supply and fix SMC junction boxes of inside dimensions 300 mm x 200 mm x 105 mm complete with provn of MS clamp to fix to Swaged pole and having MCB SP 6 to 32 Amps, 'C' curve duly fixed on din rail -01 along with RYBN terminals etc complete all as specified and directed
Supply and fix in repairs Digital Microprocessor based soft starter having IP 45 12.5/15KW , 3phase 415 volt 50HZ for suqirrel cage induction pump motor incuding protection for instantaneous over current by pass overload motor overload, phase inbalance, phase sequence , No control power, starter Ready, starter tripped, motor not running, supply falut and led indication for relay running/ starting falut code complete all as specified and directed.
Supply and fix flame proof/ weather proof LED Well Glass light fitting suitable for 60watt with lumens out put not less than 6000 lumens , body made out of LM6 epoxy painted with reflector, heat resistant Clear toughend , Type A with LED Chip including necessary fixing arrangement complete all as specified and directed.
Material and labour for earthing with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground, earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 Metre below normal ground level connected to galvanised strip 32 x 6 mm by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No. 03 of SSR Part I connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 using 20 mm stone aggregate chamber including necessary formwork / mould for fair and even surfaces, precast RCC 1:2:4 type B0 using 12.5mm stone aggregate including rainforcement chamber cover slab, GI funnel, with GI watering pipe 20 mm bore medium gde, wire mesh, protection pipe 40 mm bore GI pipe light gde for earth lead upto 7.50 meter long including testing and salt charcoal complete all as specified and directed by Engineer-in-Charge. Note : (i) GI strip beyond 7.5 mtr will be measured and paid sepeartely. (ii) Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE & PMG / user. Test results are to be written in letters of 20mm height in white colour on black paint back ground. (iii) The earth resistance should be less than 2 Ohm.
Material and labour for special factory made earthing electrode comprising of Hot dipped galvanised MS flat inserted in to GI pipe of 82 mm bore (outer), 3 metre length, filled with non magnetic anti corrosive material specially developed for ground resistance enhancement power around the electrode to retain moisture conforming to IS 3043 including necessary boring in ground of 150 mm dia in any type of strata connecting to test point including excavation/ earth work in any strata, PCC 1:3:6 type C1, using 20 mm graded stone aggregate 1:2:4 type B0 using 125 mm graded stone aggregate precast chamber cover slab with GI strip 32 mm x 6 mm upto 7.5 mtr complete and connecting to test point complete (the earth resistance shall be less than 3 Ohms). The Contractor shall improve the earthing resistance with in the permissile limit with out any extra cost.
Taking down unserviceable/ Serviceable LT cables size 185 sqmm to 400 sqmm removing lugs from switch gears and cable glands from old panels all incoming/out going connection removing / burned cables from Panel/ trenches for tracing out fault with LT megger for reuse complete all as specified and directed.
Material and labour for Hi-Pot Testing ( High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the 22 KV faulty UG XLPE cable for rectifying defects and test report to be submitted complete all as specified and directed. Note: Contractor should attend the complaint within 12 hours from receiving complaints from departments/users by any communication system.
Supply and laying, testing and commissioning of XLPE insulated, (E) armoured heavy duty electric cable with aluminium conductor, 22000 volts grade, cross-sectional area 185 sq. mmx 3 Core complete all as specified and directed Note :- Excavation & Earth work, brick protection sand cushioning shall be measured and paid separately.
Labour only for relaying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade taken from trenches in various size 185sqmm to 400qmm 3.5core including new gland and new Alumium lugs (before connecting approval shall be taken from Engieer in charge) complete all as specified and directed.
Supply and Fix in repair Electronic Digital flow meter with battery Back up type input power supply 220 VAC/24VDC, Output 4-20mA+HARD,Flow rate disply 5 digit LCD, Totaliser Display 10 digit LCD, Low velocity .033 m/s, High Velocity 15 m/s, (MModbus) Accuracy +/- 0.5 of FSD , IP 67 Optional IP 68 complete all as specified and directed. Note: The contractor shall obtain requisite permission from MIDC for executing the item and shall also submit calibration test report. The rate quoted is demed to include for the above provision.
Supply and fix LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose at any height complete all as specified and directed.
Supply and fix switch Piano 6 Amps complete all as specified and directed. Make : Anchor/ Vinay
Supply and fix SwitchSocket 6 Amps complete all as specified and directed. Make : Anchor/ Vinay
Supply and fix Switch socket 16 Amps complete all as specified and directed. Make : Anchor/ Vinay
Supply and fix Electronic Step Regulator 120watt complete all as specified and directed. Make : Anchor/ Vinay
Supply and install testing and commissioning of LT octogonal pole7 metre long with foudation bolt & nut with base plate 220x200mmx16mm ) complete all as specified and directed.
Supply and fix GI Bracket single arm for HT/LT pole, with 25 mm dia GI Pipe light grade up to 1.5 Metere length complete all as specified and directed.
Supply and fix in repair of LED street light /road way luminaries 60 watts with pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket complete all as specified and as directed.
Supply and Fix Lead Acid battery 12 volt 180 AH with brass terminals complete all as specified and directed by Engr in charge
SOURABH ENGINEERS
Minal Engineers
Borole Electricals
cooltech engineering services
Shree Ayyappa Engineering
SKS Electricals
shakti engineering and electrical works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .