| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L1 | Accepted-AOC AOC | |
| 2 | L2₹34.5 L+₹39,388 (1.15%)Rejected-Finance WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹35.8 L+₹1.7 L (4.88%)Rejected-Finance WARD NO 26 OLD 36 NEW NEAR FIRE BRIGADE OFFICE RCP TAL COLONY ROAD SURATGARH 335804 SRI GANGANAGAR RAJ | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹36.3 L+₹2.2 L (6.37%)Rejected-Finance N A | NA | NA | 121004 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹36.4 L+₹2.2 L (6.52%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹87,600
Closing Date
4 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Uday Shankar Roy
GE AF SURATGARH
ADDN/ALTN TO ENGINE BAY BUILDING AT AF STN SURATGARH
2024_MES_657846_1
8179/E8
Open Tender
Civil Works
Item Rate
180 days
SURATGARH
As per tender documents
10 documents required · 10 mandatory
₹500
GE AF SURATGARH
₹87,600
Yes
2 Sept 2024
5 Jun 2024
6 Jul 2024
5 Jun 2024
4 Jul 2024
20 Jun 2024
Amount
BOQ (ADDN/ALTN TO ENGINE BAY BUILDING AT AF STN SURATGARH)
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any type of mortar, complete all as specified and directed.
M&L for glazed ceramic tiles of size 350mmx250mmx7mm /450mmx350mmx7mm thick on vertical surfaces, set & joined in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed.
M&L for 25mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
M&L for Udaipur green marble 18mm to 20mm thick, prepolished, as in window & ventilator cills in single length andincluding screed bed or bedding layer of 15mm thick in CM 1:6, complete all as specified and directed.
Demolition of cement concrete unreinforced in groundfloors and pavings not exc 15cm thickness below or above ground level etc, complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub bases, complete all as specified and directed.
M&L for Machine pressed PU coated precast concrete interlocking paver block any shape , size and pigment confirming to IS 15658-2006 of 80mm thickness, M-35 Grade with grey cement and pigments, complete all as specified and directed.
M&L for 25mm thick Sand filling under floors or in foundation including watering and consolidation, complete all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment of soil under existing floors using emulsion @ one litre per litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors, complete all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Anti-termite TreatmentAlong the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed.
Taking down cement plaster on stone walls including raking out joints, hacking for key, scrubbing down with water, complete all as specified and directed.
M&L for rendering 10mm thick plaster on brick or concrete surfaces in cement mortor 1:6 finished the surface even and smooth without extra cement as intrnal surfaces of wall, complete all as specified and directed.
M&L for rendering 15mm thick on concrete or brick masonry surfaces or surface other than fair face of brickwork in cement mortor 1:4 as in external surfaces of wall, complete all as specified and directed.
M&L for rough cast plaster over 10mm rendering in CM 1:6, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls / ceiling and applying two coats of oil bound distemper on a coat of 1.5-2mm thick wall putty, complete all as specified and directed.
M&L for applying two coats of exterior acrylic emulsion (weather proof treatment) over a coat of primer, in camouflaging patterns , including preparation of new surfaces like brooming down or steel wire brushing scraping down smoke soot, moulds mass and efflorescent salt and trading oil and greasy spots, complete all as specified and directed.
M&L for preparing old painted surfaces by washing, rubbing down and stopping of distempered and painted surfaces and applying a two coat of oil bound distemper over a coat of 1.5mm-2mm wall putty surfaces of walls and ceiling complete all as specified and directed by Engineer-in-charge.
Taking down door chowkhat or frame including shutter area not exc 1.50 sqm each and removing to store, complete all as specified and directed.
Taking down door chowkhat or frame including shutter area exc 1.50 sqm and not exc 4.00 sqm and removing to store, complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection flooring, complete all as specified and directed.
S&F for designer Gypsum ceiling board of size 595mmx595mmx12mm thick as in ceiling, fixed with screws on GI grid frame work of size 600mmx600mm, GI T-section of size 25mmx25mmx1.25mm, GI L-section 25mmx25mm x1.25mm, hanging arrangements with roof with GI wire not less than 2.00mm dia, complete all as specified and directed by Engineer-in-Charge.
S&F for hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40mmx3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, complete all as specified and directed.
M&L for brick work with subclass B bricks, straight curved on plan exc 6m mean radius in cement mortar 1:6, complete all as specified and directed.
Returning filling in soil including spreading, levelling and well ramming in layers not exc 25cm thick in layer etc, complete all as specified and directed.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, Windows ( sliding two or three track / openable), ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket, handle ,lock, etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, complete all as specified and directed.
S&F in repair aluminium (extruded section body) door closer hydraulically regulated, designation No.2, universal type, suitable for door shutter of 701mm to 850mm in width & of weight between 36 to 60 kg, complete all as specified and directed.
S&F for aluminium chequered grills as on aluminium windows, weight not exc .0.50 kg/sqm and fixed including taking down of old unservicable grill, complete all as specified and directed by Engineer in charge.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugaed steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
S&F for mild steel plates, plain or chequered, in 5mm thick or over in thickness in available sizes, Fe 410-W (Gde E-250) quality, complete all as specified and directed.
S&F for stucural steel work in tubular/square tube/angles/ I sections as in trusses piers including special shaped washer , gusset/bearing plate etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade ST-240, complete all as specified and directed.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5m in depth and getting out, complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description applying two coats of synthetic enamel ordinary tint over coat of red oxide primer of any description exc 10 cm girth, not otherwise described, complete all as specified and directed
Surface excavation not exc 30cm deep and avereging 15cm deep in soft/loose soil and getting out, complete all as specified and directed.
Removing excavated material not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and directed.
M&L for 100mm thick, PCC 1:4:8 type D-2 (using 40mm graded stone aggregate), as in sub base under floor, complete all as specified and directed.
M&L for forming embankments including raising (or lowering) earth, spreading in layers not exc. 30cm thick; watering, well ramming and finishing to required size, shape,etc., not exc. 1.5m high from base, complete all as specified and directed.
M&L for hardcore of gauge not exc 63mm, deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface in broken stones or boulders, complete all as specified and directed.
M&L for two coats of exterior acrylic emulsion (weather proof treatment), in camouflaging patterns , including preparation of old surfaces like brooming down or steel wire brushing scraping down smoke soot, moulds mass and efflorescent salt and trading oil and greasy spots complete all specified and directed.
M&L for machine cut kota stone slab 18mm to 20mm thick as in flooring/stair case landing, laid over & including 15mm thick cement screed base in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing, complete all specified and directed.
Excavation over area not exc 1.5m deep and getting out in soft / loose soil, complete all specified and directed.
M&L for reinforcement cement concrete M25 Design mix (with 20 mm graded stone aggregates) in beams, cantilevers, bressummers, lintel over 1.5m span, complete all specified and directed.
M&L for reinforcement cement concrete M25 Design mix (with 20mm graded stone aggregates) in slabs supported on walls, beams, and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all specified and directed.
M&L fpr reinforced cement concrete , Design Mix, Type M-25 (using 20mm graded stone aggregate) Walls, retaining walls,basement walls, ballast walls and the like; anythickness; above top of footings including attached pilasters and buttresses complete all as specified.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work n. exceeding 200mm thick (horizontal or sloping) for rough finished surface of concrete, complete all specified and directed.
Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for rough finished surface of concrete, complete all specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.for rough finished surfaces of concrete, complete all specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, complete all specified and directed.
S&F Mild steel TMT reinforcement bars 10mm dia and over cut to length and bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in reinforcement complete all specified and directed..
Ditto all as item No 52 above but 8mm dia and over upto and including 10mm dia as in stirrups, spacers and binders. complete all specified and directed.
S&F for 1mm thick steel rolling shutters,without ball bearing,as specified including top cover,an-choring rod,hasp and staple and one shop coat of primer erected in position as indicated but gear operated type with bevel gear box including shaft and crank handle complete all as specified and directed by Engineer-in Charge. Note :- (Replace New rolling shutter in place old Manual/Gear operated rolling shutter) Rolling Shutter Including all parts as per IS code 6248-1979 1. Crank Handle 2. Pluge Boalts 3. Crank stand 4. Guide Rail 5. Crank driving Wheel 6. Upper Box 7. Lower Box 8. Crank Fitting 9. Slats 10. Slats Cap 11. Bottom Slats 12, Sealing Belts 13. Limit Knob 14. All Bearing of any size complete. (Measurment of Rolling in width including side guid rails and in height from Botoom slats(bottom plat) upto botoom of hood cover/below the slats shaft tube)
S&F for 8mm thick hollow printed coloured PVC sheet wall lining/panelling including frame work (sample kept in GE office) made of 1mm thick PVC sheet in strips and channels feathered at the edges for fixing of wall lining inclusive of solvent cement and fixing at site , complete all as specified and directed by the Engineer-in-Charge
Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power)complete including fixture and fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings, wooden terminal boxes, plastic laminated sheet cover, including taking down of DB’s, meter board any type, complete all as specified and directed.
Dismantling and taking down fluorescent tube light single/double of any wattage or size fitting for repair or replacement of burnt/worn out accessories or carrying to MES store(Accessories or components to be provided free for replacment by department), complete all as specified and directed
Taking down unserviceable sub main wiring of any type/size including wires, conduits/batten etc, complete all as specified and directed
Taking down unserviceable DB's box including MCB's of any size/rating, complete all as specified and directed.
M&L for point wiring (concealed) in and including rigid non metallic PVC heavy duty conduit, 20mm dia as per site requirement for concealed conduit wiring with 1.5 sqmm FRLS PVC insulated unsheathed multi stranded copper conductor cable with flush type metal boxes modular type suitable for fixing modular switches, sockets, fan regulator etc with white or any colour cover plate with and including PVC insulated unsheathed multi stranded copper conductor cable of 1.5 Sqmm as an earth wire connected to common earth and earth dolly as per IS specification & as specified for one light /fan /buzzer/socket point controlled by one modular switch. (a) One light point/ceiling fan/exhaust fan controlled by one switch. Note: Metal flush box and other modular accessories except switches, sockets, and fan regulators shall be deemed included in the rate quoted.
All as per Srl item No 57 here-in-before but one 5 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size, complete all as specified and directed.
All as per Srl item No 57 here-in-before but for one 5 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size, complete all as specified and directed.
All as per Srl item No 57 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 sqmm stranded copper conductor FRLS cable PVC insulated including earth wire 2.5 sqmm copper conductor FRLS cable connected to earth dolly, complete all as specified and directed
All as per Srl item No 57 here-in-before but for one power point (for AC/Geyser) out let with 4.0 sqmm stranded copper conductor FRLS cable PVC insulated including earth wire 4.0 sqmm copper conductor FRLS cable connected to earth dolly, complete all as specified and directed.
S&F for modular switch one way 6 Amps one module, complete all as specified and directed.
S&F for modular socket 6 and 16 Amps 3 & 6 Pin combined 02 module, complete all as specified and directed.
S&F for modular socket 6 Amps 5 Pin combined 02 module, complete all as specified and directed
S&F for modular switch one way 16 Amps, one module, complete all as specified and directed
S&F of ceiling rose, surface type, 65mmx50mm, 3 terminal complete all as specified and as directed by Engr-in-Charge.
S&F of lamp holder, PVC/polycarbonate type, insulated body with back plate of batten fitting, complete all as specified and as directed by Engr-in-Charge.
S&F of LED bulb 09 watt, complete all as specified and directed
S&F for LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose, complete all as specified and directed
S&F for LED bulkhead luminaire 10 watt, wall/surface mounted complete with LED lamp 10 watt, all accessories, pre-wired including providing flexible copper wire, twin core cable PVC insulated sheathed, complete all as specified and directed .
S&F for LED 2'x2'size backelite panel light 36 Watt environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaries with high brightness SMD LEDs as light source 28 Watt with nominal system lumen output of 2800 lumens and a minimum system efficacy of 100 lm/W. The luminarie shall have a rated system lifetime of 50,000 burning hours at L70. The luminarie should have a color temperature of 6500K and CRI > 70. The luminarie shall meet IP 66 rating and IK 09 rating with THD < 20% and PF >0.9, complete all as specified and directed.
S&F for 50 Watt LED Flood light Warm type (yellow) with pressure die cast aluminium housing & toughened glass with IP-65 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 120 lumen/Watt (Minimum lumen output of luminarie should be 15000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of Yellow 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report, complete all as specefied and directed by Engr-in-charge.
S&F for LED building security light 30 watt, 230V with lens and toughen glass top.The luminarie should have a color temperature of 6500K, IP 65 complete PF > 0.95 with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20/25 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener, complete all as specified and directed
Taking down carefully Service/Unserviceable Flood light fitting any size/watt from wall/Structure and repair/replacement of worn out parts and carbon cleaning of fittings,cover,copper wire/aluminium wire,clamps ,nuts and bolts, mounting bracket/wall and re assembling the same after repair,testing and refixing in wall including provision of necessery T & P like ladder/Boom Vehicle, tools ets as required for taking down and refixing of flood light, complete all as specified and directed
Taking down wall mounted fans of any sweep and any size including cable connections and disconnecting of fan blades and removing the fan with blades deposit to store yard as it is in working condition for further hanging in its original position or any other position including as per direction of Engineer-in-Charge including it's fitting and fixtures after carrying out service includes cleaning, greasing and oiling, painting of fan with one coat of synthetic enamel spraying painting including marking of MES number with black paint after preparation of surface reassembling the fan etc including testing, complete all as specified and as directed by Engr- in-charge. Note :- Any damage has to be made good by the contractor to make the item functional after testing.
Taking down exhaust fans of any sweep and any size including cable connections and removing the exhaust fan with blades deposit to store yard as it is in working condition for further fixing in its original position or any other position as per direction of Engineer-in-Charge including it's fitting and fixtures after carrying out service i.e. cleaning, greasing and oiling, painting of exhaust fan with one coat of synthetic enamel spraying painting including marking of MES number with black paint after preparation of surface reassembling the fan etc including testing, complete all as specified and as directed . Note :- Any damage has to be made good by the contractor to make the item functional after testing.
S&F for Wall fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers, complete all as specified and as directed.
M&L for submain wiring with two single core 6.0 sqmm PVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit of size not less than 25mm dia, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 6.0 Sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed. Note- (a) The two runs of single core cable and specified earth continuity conductor and PVC conduit with fitting acessories will be measured as one run. (b) Cost of cutting, chasing and make good to existing surfaces are deemed to be including in the quoted rate by the contractor.
M&L for submain wiring with two single core 2.5 sqmm PVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit of size not less than 25mm dia, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 2.5 Sqmm multistranded copper conductor cable as continuous earth wire, complete all as sepcified and as directed. Note- (a) The two runs of single core cable and specified earth continuity conductor and PVC conduit with fitting acessories will be measured as one run. (b) Cost of cutting, chasing and make good to existing surfaces are deemed to be including in the quoted rate by the contractor.
M&L for submain wiring with two single core 1.5 sq mm PVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit of size not less than 25mm dia, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 1.5 Sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed. Note- (a) The two runs of single core cable and specified earth continuity conductor and PVC conduit with fitting acessories will be measured as one run. (b) Cost of cutting, chasing and make good to existing surfaces are deemed to be including in the quoted rate by the contractor.
S&F in replacement sheet metal enclosures single pole and neutral earth enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps, 240 volts, complete all as specified and directed.
S&F of sheet metal enclosure for distribution board SPN (when MCBs to be used) 12 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail, complete all as specified and as directed by Engr-in-Charge.
S&F of sheet metal enclosure for distribution board SPN (when MCBs to be used) 8 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail, complete all as specified and as directed by Engr-in-Charge.
S&F of sheet metal enclosure for distribution board SPN (when MCBs to be used) 4 way Single door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed by Engr-in-Charge.
S&F of MCB SP, 6-32A,10KA complete all as specified and as directed . Make:- Legrand cat part No. : 4085 87-95 or equivalent in ABB/Schneider.
S&F of MCB SPN, 32A ,10KA, complete all as specified and as directed . Make: Legrand cat part No. : 4086 17 or equivalent in ABB/Schneider.
S&F of vertical MCB DB TPN 4 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V including provision for mounting MCCB upto 200 Amps rating complete all as directed by Engr-in-Charge.
S& F of MCCB four pole 200 Amps with breaking capacity 16KA , 415 Volts, thermal & magnetic release including making all incoming/ outgoing connections outgoing electrical connection with suitable size of copper lugs etc. complete all as specified and directed by Engineer in Charge.
S&F of MCB TP (three poles), 63 Amps, breaking capacity 10 KA 'C' curve confirming to IS-8828, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc, complete all as specified and directed
S&F of MCB TP (three poles), 40 to 100 Amps, breaking capacity 10 KA 'C' curve confirming to IS-8828, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc, complete all as specified and directed
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge, 8 mesh per liner inch, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with XPM JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified and directed.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17(R) of tender documents.
Gill Construction Co
M/s Shubham Enterprises
Gaurav India Corporations
SRI SAI CONSTRUCTION COMPANY
M/S VISHNU ENTERPRISES
Bhawani Enterprises
H S BUILDERS
M/s JUGAL KISHORE MISHRA AND SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .