Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical 0 VILL JULEHRA SARDHANA SARDHANA MEERUT MEERUT UTTAR PRADESH 250342 | MEERUT | UTTAR PRADESH | 250342 | Rejected-Technical Incomplete Document |
Tender Value
₹21.2 L
EMD Value
₹21,200
Closing Date
7 Mar 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
SE, EDC-1, Meerut
ETN0-95/EDC-MT/2024-2025
2025_PVVNL_1012469_1
ETNo.95/EDC-MT/2024-25
Open Tender
Electrical Works
Lump-sum
180 days
Under EDD-KITHORE
ETN0-95/EDC-MT/2024-2025
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER
₹21,200
20 Mar 2025
1 Mar 2025
7 Mar 2025
1 Mar 2025
7 Mar 2025
1 Mar 2025
Amount
Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. :-
PCC Pole/STP Pole
Line material such as Cross arms, pin, pin insulator, Disc, Stay rod, Stay wire ACSR conductor, GI Wire, MS angle iron & MS Channel, TPMO, Fuse set etc.
Metering cubical & double pole CT/PT Unit etc.
10 KVA to 100 KVA T/F including complete related material required for transformer.
250/400 KVA T/F including complete related material required for transformer.
HT/LT XLPE Cable of various size.
ABC cable of various size.
Erection of PCC pole/STP Pole with grouting after digging a pit of size 1.6 mtr deep in all type of Soil including back filling of the pole with proper ramming after completion of work (as per UPPCL Respo).
Fabrication and fixing of all HT/LT line accessories (as per UPPCL Respo).
Erection of Double pole on PCC pole 8.5 mtr/STP Pole 11 mtr long with grouting after digging a pit of size 1.6 mtr deep in all type of Soil for each pole including back filling of the pole with proper ramming after completion of work. (as per UPPCL Respo).
Fabrication and fixing of MS angle and MS channel, fixing all accessories, Fuse set, pin insulators on D/P Pole. (as per UPPCL Respo).
Mounting/Installation of Metering cubical & double pole CT/PT Unit etc.
Mounting/Installation of 10 to 100 KVA T/F with proper jumpering of HT side and fixing of cable on LT side of T/F. (as per UPPCL Respo).
Making of New 250/400 KVA T/F Plinth of size 6'x6'x3' (feet) (as per UPPCL Respo).
Fencing of 250/400 KVA T/F (as per UPPCL Respo).
Mounting/Installation of 250/400 KVA T/F with proper jumpering of HT side and fixing of cable on LT side of T/F. (as per UPPCL Respo).
Making a section pole to exist pole after fabrication & fixing of T channel fixing of all accessories. (as per UPPCL Respo).
Erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming.
Laying lifting stringing & proper sagging of ACSR conductor for 3 phase, 3 wire line including binding & jumpering properly. (as per UPPCL Respo).
Guarding of line with G.I. wire having 2 no. horizontal wire & 3 Mtr distance of SWG G.I. wire after fabrication of guard cross arms of & fixing the same in supports. (as per UPPCL Respo).
Laying of XLPE Cable of various size by pit of the size 1.5 in the trench and road crossing in the air (as per UPPCL Respo).
Laying of XLPE Cable of various size by Trenchless boring (as per UPPCL Respo).
Filling of Jointing Kit Indoor/Outdoor of various size (as per UPPCL standard).
Laying of ABC Cable of various size including fixing of all ABC accessories on support (as per UPPCL Respo).
Fixing of Distribution box including fixing the cable from transformar and consumer service cable (as per UPPCL Respo).
Earthing of each pole/ Transformers properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with GL wire. (as per UPPCL Respo).
Chemical earthing of T/F (Neutral and body) with GI Pipe 32mm Dia. (as per UPPCL Respo).
Providing and fixing G.I Pipe 6 dia (As Per Direction of Supervising Engineer).
Providing and fixing of Holding Clamp (As Per Direction of Supervising Engineer).
Providing and fixing of LT Clamp (As Per Direction of Supervising Engineer).
Providing and fixing of J Hook (As Per Direction of Supervising Engineer).
Providing and fixing of Piercing Clamp (As Per Direction of Supervising Engineer).
Providing and fixing of Dead and Clamp(As Per Direction of Supervising Engineer).
Providing and fixing of MS Nut and Bolts(As Per Direction of Supervising Engineer).
Cutting & chopping tree branches near side of line for making the clearance between line and tree.
M/s Sigma Electricals (BID ID -5024620)
BHARDWAJ ENTERPRISES (BID ID -5023218)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .