Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
22 Jul 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tata Power Delhi Distribution Limited
Two Year Rate Contract for 11kV & LT associated works in PAN Tata Power-DDL, Delhi
200001967
TPDDL/ENGG/ENQ/200001967/26-27
Delhi
a) The bidder should have an average annual turnover of Rs. 30 lakhs in last three financial years (FY 24- 25, FY 23-24, FY 22-23). Copy of audited Balance Sheet and P&L Account to be submitted in this regard.
b) The bidder must have executed similar jobs for maintenance/ commissioning of 11 kV and LT network in any utility/companies for a total value of Rs. 30 Lac or one single order of Rs. 15 lacs or two orders of Rs. 8 lacs each or three order of Rs 5 lac each during last 3 financial years. Copy of work order / completion certificate to be submitted in this regard.
c) The bidder should have satisfactory performance certificates from at least 2 reputed companies (one from each company) for similar work or higher rating work. The work against these issued certificates should be completed in last seven years from the date of bid submission. In case the bidder has a previous association with Tata Power DDL for similar products and services, the performance feedback for that bidder by Tata Power-DDL’s User Group shall only be considered irrespective of performance certificates issued by any third organization."
d) The bidder must have all statutory compliance like valid PAN no., ESI registration, EPF registration, GSTN etc. The bidder must submit the copy of all these registrations.
e) The bidder should have Valid Electrical Contractor License issued by Govt of NCT of Delhi to execute the electrical works in Delhi. Copy of valid Electrical Contractor License issued by Govt. of NCT Delhi needs to be submitted by bidder. In case bidder is not having this License, Bidder shall submit an undertaking that in case they are the successful bidder, same shall be obtained by them before award of contract by TPDDL.
₹5,000
₹5 L
1 Jul 2026
1 Jul 2026
22 Jul 2026
S. No. New Item Description UOM Quantity (Q) Unit Price (Rs.) (A) GST (B) All Inc. Price (C) = (A)+(B) All Inc value (D) =(C)*(Q)
1 Installation/Erection of 11 Mtr. PSCC Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 20000
2 Installation/Erection of 9 Mtr. PSCC Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 5000
3 Installation/Erection of 13 m long Rail Pole including loading and unloading, excavation, fixing of base plate, grounting, refilling, disposing & removal of malba, flooding with water, ramming/ compacting of foundation as per Tata Power-DDL specifications and drawing including removal & disposal of malba as per instruction of EIC. Scope of work also includes Pole Indexing, Painting of Pole (In Black & Yellow Strips/Zebra), Painting of Pole with one cote of red oxide and two coats of AL Paint (paint to be supplied by BA of ISI Mark/superior quality). The scope of work excludes, providing & laying of cement concrete. EA 10
4 Painting of Pole In Black & Yellow Strips/Zebra as per Tata Power-DDL specifications and indexing/numbering of Poles as per GIS format, scope also include site survey for GIS indexing and supply of ISI Marked good quality paint. (this item shall be paid for old poles only and where this not mentioned in scope) EA 25000
5 Pole indexing/numbering as per GIS format and Tata Power-DDL specifications including site survey for GIS indexing and supply of ISI Marked good quality paint. (this item shall be paid for old poles only and where this not mentioned in scope) EA 25000
6 Brick betting for Pole foundation including supply of consumables and stengthening as per Tata Power-DDL specification/drawing (Price per pole/foundation) EA 25000
7 Welding of Transformers as per requirement after installation, testing and commissioning (minimum no. of points for weld shall be 4 no. and 5 No. for single phase & three phase transformer each respectively and maximum no. of welds shall be as per requirement/recommendation of project incharge) EA 1000
8 Installation, Testing and Commissioning of 11kV CT PT Unit on existing structure as per Tata Power-DDL specification including installation of Pipe, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection EA 50
9 Installation, Testing and Commissioning of 11kV Metering Cubicle on existing structure as per Tata Power-DDL specification including loading, unloading, shifting /transportation from site/tent. Scope of work excludes earthing, jumpering / connection. EA 200
10 Installation of 11 kV 3- Phase AB/G.O Switch on existing structure including alignment as per Tata Power-DDL specification and drawing EA 1000
11 Installation of 11kV D.O Fuse Single Phase including Fuse Link on existing structure as per Tata Power-DDL specification and drawing EA 500
12 Installation of 11kV D.O. Fuse 3 Phase(Price per Set) including Fuse Link on existing structure as per Tata Power-DDL specification and drawing ST 2500
13 Installation of 11kV LA Single Phase on existing structure as per Tata Power-DDL specification and drawing EA 8000
14 Installation of HT Aluminium Bus Bar mounted on 11 kV insulator with re-openable insulation/cover for holding T-off connector/ termination kits as per Tata Power-DDL specification and drawing EA 500
15 Installation of 11kV Pin Insulator with hardware/PIN as per Tata Power-DDL specification & drawing EA 20000
16 Installation of 11kV Disc Insulator with all hardware fittings as per Tata Power-DDL specification & drawing. EA 1000
17 Installation of Anti-Climbing Device for 11Mtr/9 Mtr Pole as per Tata Power-DDL specification and drawing. EA 25000
18 Installation of HT/LT Danger Board as per Tata Power-DDL specification & Drawing. EA 25000
19 Installation of 2 line cross arm on 9M/11M pole as per Tata Power-DDL specification and drawing. EA 5000
20 Installation of V cross arm on 11 mtr pole as per Tata Power-DDL specification and drawing. EA 2000
21 Fixing of LT Complete Stay Set as per Tata Power-DDL specifications and drawing. The scope of work includes excavation for all type of soils/RCC/Bituminous/ Rocky/ Rajasthani tiles etc., breaking of asphalt, fixing of Base Plate,Anchor road, Tension screw, Egg insulator, back filling removal & disposing of malba as per instruction of EIC etc. but excludes stringing of GI Wire, fabrication works and providing and laying of cement concrete. ST 2000
22 Fixing of HT Complete Stay Set as per Tata Power-DDL specifications and drawing. The scope of work includes excavation for all type of soils/RCC/Bituminous/ Rocky/ Rajasthani tiles etc. , breaking of asphalt, fixing of Base Plate,Anchor road, Tension screw, Egg insulator, back filling removal & disposing of malba as per instruction of EIC etc. but excludes stringing of GI Wire, fabrication works and providing and laying of cement concrete. ST 3500
23 Installation of Outdoor Type Distribution Box with MCCB for 6.3/0.24kV Single Phase Transformer on existing structure as per Tata Power-DDL specification and drawing. EA 20
24 Installation of Outdoor Type Distribution Box with MCCB for 6.3/0.24kV,10kVA Single Phase Transformer on existing structure as per Tata Power-DDL specification EA 2
25 Installation of Outdoor Type Distribution Box with MCCB for 6.3/0.24kV,16kVA Single Phase Transformer on existing structure as per Tata Power-DDL specification EA 2
26 Installation of Outdoor Type Distribution Box with MCCB for 11/0.4kV,25kVA Single Phase Transformer on existing structure as per Tata Power-DDL specification EA 2
27 Installation testing and commissioning of LT ACB 400 Amps with enclosure on existing structure as per Tata Power-DDL specification and drawing. EA 2500
28 Installation testing and commissioning of LT ACB 800 Amps with enclosure on existing structure as per Tata Power-DDL specification and drawing. EA 50
29 Installation testing and commissioning of LT ACB 1250 Amps with enclosure on existing structure as per Tata Power-DDL specification and drawing. EA 50
30 Installation testing and commissioning of LT ACB 2000 Amps with enclosure on existing structure as per Tata Power-DDL specification and drawing. EA 10
31 Installation of LT Distribution Box with bus bars for LT Service connection as per Tata Power-DDL specification and drawing. EA 10000
32 Erection of Feeder Pillar Type - A /B as per Tata Power-DDL specification and drawing on existing Structure/foundation. Scope of work exclude construction of foundation (brick work, concreting etc) and earthing. EA 700
33 Erection of Service Pillar as per Tata Power-DDL specification and drawing on existing Structure/foundation. Scope of work exclude construction of foundation (brick work, concreting etc) and earthing EA 500
34 Installation of 415 V, 3 Phase ICTPN/ MCCB based street light switch Unit including taping there of as required (cable dressing & one end cable termination) EA 500
35 Installation of Eye hook (Bolt type) as per Tata Power-DDL specification and drawing EA 10000
36 Installation of Dead End Clamp for HT/LT AB Cable as per Tata Power-DDL specification and drawing EA 3000
37 Installation of Suspension Clamp for HT/LT AB Cable as per Tata Power-DDL specification and drawing EA 3000
38 Installation of Insulated Piercing Connector as per Tata Power-DDL specification and drawing EA 40000
39 Installation of Clamps & Connectors (Wedge, PG etc.)as per Tata Power-DDL specification and drawing EA 3000
40 Installation of Palm connector as per Tata Power-DDL specification and drawing EA 500
41 Installation of Service main Anchor(Wall corner clamp) as per Tata Power-DDL specification and drawing EA 500
42 Earthing by boring in ordinary soil upto water level (up to 3 Mtr.depth) with fixing of earth Pipe and connecting GI Stay wire 7/8 or 7/10 SWG as per Tata Power-DDL Earthing Philosophy (Each pit resistance will be measured and recorded and shall be within 1-3 ohm). Scope excludes supply of earth pipe, laying of GI Wire and crimping of Lugs. EA 200
43 Earthing by boring in ordinary soil upto water level (above 3m to 6 Mtr.depth) with fixing of earth Pipe and connecting GI Stay wire 7/8 or 7/10 SWG as per Tata Power-DDL earthing philosophy (Each pit resistance will be measured and recorded and shall be within 1-3 ohm). Scope excludes supply of earth pipe, laying of GI Wire and crimping of Lugs. EA 20000
44 Earthing by boring in ordinary soil upto water level (above 6m to 9 Mtr.depth) with fixing of earth Pipe and connecting GI Stay wire 7/8 or 7/10 SWG as per Tata Power-DDL earthing philosophy (Each pit resistance will be measured and recorded and shall be within 1-3 ohm). Scope excludes supply of earth pipe, laying of GI Wire and crimping of Lugs. EA 5000
45 Earthing by boring in ordinary soil upto water level (above 9m to 15 Mtr.depth) with fixing of earth Pipe and connecting GI Stay wire 7/8 or 7/10 SWG as per Tata Power-DDL earthing philosophy (Each pit resistance will be measured and recorded and shall be within 1-3 ohm). Scope excludes supply of earth pipe, laying of GI Wire and crimping of Lugs. EA 1000
46 Installation of GI Strip 50X6 mm for earthing of equipments including welding and painting of joints with black colour as per Tata Power-DDL specification and supply of consumable as required. M 20000
47 Sagging/Stringing/Drawing of GI wire 7/10 or 7/8 SWG for earting of equipments/structure as per Tata Power-DDL specification and drawing. M 800000
48 Sagging/Stringing/Drawing of GI wire 4/6/8 SWG including Jumpering & making of connection hooks etc. as per Tata Power-DDL specification and drawing M 40000
49 Making & Fixing of Guard Lace of G.I. Wire 4/6/8 SWG for HV/LV Line (price per lacing) as per Tata Power-DDL specification & drawing EA 5000
50 Installation of 40 mm dia GI Pipe for earth wire/Cable protection as per Tata Power-DDL specification & drawing M 200
51 Laying of HUME - up to 200mm dia and sealing of the same for Laying LT/HT Cables. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe.as per Tata Power-DDL specification & drawing (Excavation is excluded) M 200
52 Installation of HDPE Pipe - 40 mm dia and sealing of the same for wire/Cable protection. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe as per Tata Power-DDL specification & drawing M 5000
53 Sagging & Stringing of Wolf Conductor including Jumpering & making of connection hooks etc as per Tata Power-DDL specification & drawing M 2000
54 Sagging & Stringing of Dog Conductor(Bare/ Insulated) including Jumpering & making of connection hooks etc as per Tata Power-DDL specification & drawing M 50000
55 Sagging & Stringing of Rabbit (Bare/insulated) Conductor including Jumpering & making of connection hooks etc.as per Tata Power-DDL specification & drawing M 10000
56 Laying ,testing & commissioning of 11kV Armoured XLPE AL Cable/CCD Cable of size 3CX400/ 3X300 sqmm (Single Run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 20000
57 Laying, testing & commissioning of 11kV Armoured XLPE AL Cable/CCD Cable of size 3CX400/ 3X300 sqmm (Double RUN) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 10000
58 Laying testing & commissioning of 11kV Armoured XLPE AL Cable of size 3CX150 sqmm in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 200
59 Laying testing & commissioning of 11kV Armoured XLPE AL Cable 3CX400/ 3CX300 sqmm in trenchless duct as per Tata Power-DDL specification & drawing. Scope of work exclude fixing/laying of HDPE pipe.Also provide ABD to EIC M 100000
60 Stringing of 11kV, XLPE insulated, AL Conductor AB Cable 3CX95+1CX95 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 500
61 Stringing of 11kV, XLPE insulated, AL Conductor AB Cable 3CX150+1CX150 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 100000
62 Stringing of 11kV, XLPE insulated, AL Conductor AB Cable 1CX95+1CX55 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 200
63 Stringing of 11kV, XLPE insulated, AL Conductor AB Cable 1CX150+1CX155 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 10000
64 Installation of Straight Through Jointing Kit for 11kV XLPE insulated, AL conductor AB Cable 1CX95sqmm as per Tata Power-DDL specification & drawing EA 20
65 Installation of Straight Through Jointing Kit for 11kV XLPE insulated, AL conductor AB Cable 1CX150sqmm as per Tata Power-DDL specification & drawing EA 200
66 Installation of Outdoor End Termination Kit of 1CX95 sqmm (Single) for 11kV XLPE insulated AL AB Cable as per Tata Power-DDL specification & drawing EA 50
67 Installation of Outdoor End Termination Kit of 1CX150 sqmm (Single) for 11kV XLPE insulated AL AB Cable as per Tata Power-DDL specification & drawing EA 1000
68 Stringing of 1.1 kV XLPE insulated AL conductor AB Cable of size 4C X 70 + 1C X 75 SQMM + 1 X 16 sqmm as per Tata Power-DDL specification including testing of cable M 500
69 Stringing of 1.1 kV XLPE insulated AL conductor AB Cable of size 3C/4C X 150 + 1C X 155 SQMM + 1 X 16 sqmm as per Tata Power-DDL specification including testing of cable M 300000
70 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 2CX10 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 100000
71 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 2CX25 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 100000
72 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 4CX25 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 200000
73 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 4CX50 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 100000
74 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 4CX95 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 30000
75 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 4CX150 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 50000
76 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 4CX300 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 100000
77 Stringing/Laying of 1.1kV XLPE insulated PVC sheathed AL conductor Cable of size 1CX95 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 5000
78 Stringing/Laying of 1.1kV XLPE insulated PVC sheathed AL conductor Cable of size 1CX185 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 1000
79 Stringing/Laying of 1.1kV XLPE insulated PVC sheathed AL conductor Cable of size 1CX300 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 30000
80 Stringing/Laying of 1.1kV XLPE insulated PVC sheathed AL conductor Cable of size 1CX630 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 60000
81 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 2CX16 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 10000
82 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 2CX25 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 100000
83 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 4CX25 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 5000
84 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 4CX50 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 3000
85 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 4CX95 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 10000
86 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 4CX150 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 3000
87 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 4CX300 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 50000
88 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX150 sqmm in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
89 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX300 sqmm in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
90 Installation of Straight Through Joint KIT for LT AB Cable 1CX70 sqmm as per Tata Power-DDL specification and drawing EA 20
91 Installation of Straight Through Joint KIT for LT AB Cable 1CX150 sqmm as per Tata Power-DDL specification and drawing EA 20
92 Crimping and Fixing/connecting to terminal of AL Lugs 4 sqmm as per Tata Power-DDL specification and drawing EA 1000
93 Crimping and Fixing/connecting to terminal of AL Lugs 10 sqmm as per Tata Power-DDL specification and drawing EA 1000
94 Crimping and Fixing/connecting to terminal of AL Lugs 25 sqmm as per Tata Power-DDL specification and drawing EA 50000
95 Crimping and Fixing/connecting to terminal of AL Lugs 35 sqmm as per Tata Power-DDL specification and drawing EA 200
96 Crimping and Fixing/connecting to terminal of AL Lugs 50 sqmm as per Tata Power-DDL specification and drawing EA 20000
97 Crimping and Fixing/connecting to terminal of AL Lugs 70 sqmm as per Tata Power-DDL specification and drawing EA 200000
98 Crimping and Fixing/connecting to terminal of AL Lugs 95 sqmm as per Tata Power-DDL specification and drawing EA 50000
99 Crimping and Fixing/connecting to terminal of AL Lugs 150 sqmm as per Tata Power-DDL specification and drawing EA 20000
100 Crimping and Fixing/connecting to terminal of AL Lugs 185 sqmm as per Tata Power-DDL specification and drawing EA 500
101 Crimping and Fixing/connecting to terminal of AL Lugs 300 sqmm as per Tata Power-DDL specification and drawing EA 50000
102 Crimping and Fixing/connecting to terminal of AL Lugs 400 sqmm as per Tata Power-DDL specification and drawing EA 5000
103 Crimping and Fixing/connecting to terminal of AL Lugs 630 sqmm as per Tata Power-DDL specification and drawing EA 20000
104 Glanding armored 1.1 kV XLPE AL Cable - 2CX2.5/16/25 sqmm, including making hole in base plate and dressing of cable as per Tata Power-DDL specification and drawing EA 5000
105 Glanding armored 1.1 kV XLPE AL Cable - 4CX25 sqmm, including making hole in base plate and dressing of cable as per Tata Power-DDL specification and drawing EA 5000
106 Glanding armored 1.1 kV XLPE AL Cable - 4CX50 sqmm, including making hole in base plate and dressing of cable as per Tata Power-DDL specification and drawing EA 1369
107 Glanding armored 1.1 kV XLPE AL Cable - 4CX95 sqmm, including making hole in base plate and dressing of cable as per Tata Power-DDL specification and drawing EA 3000
108 Glanding armored 1.1 kV XLPE AL Cable - 4CX150 sqmm, including making hole in base plate and dressing of cable as per Tata Power-DDL specification and drawing EA 1000
109 Glanding armored 1.1 kV XLPE AL Cable - 4CX300 sqmm, including making hole in base plate and dressing of cable as per Tata Power-DDL specification and drawing EA 1000
110 Glanding armored 1.1 kV XLPE AL Cable - 1CX300 sqmm, including making hole in base plate and dressing of cable, as per TPDDL specification and drawing. EA 2000
111 Glanding armored 1.1 kV XLPE AL Cable - 1CX630 sqmm, including making hole in base plate and dressing of cable , as per TPDDL specification and drawing. EA 2000
112 Providing connection of service cable, 1 phase in LV distribution box / IPC, , as per TPDDL specification and drawing. EA 5000
113 Providing connection of service cable, 3 phase in LV distribution box / IPC, , as per TPDDL specification and drawing. EA 5000
114 Mounting of Cable (below 70 sqmm) at Pole, after passing through suitable size of GI Pipe proper clamping and fixing cleating arrangement along with clamping of terminations as per Tata Power-DDL specification and drawing . Scope of work exclude supply and erection of Cleat set ST 500
115 Mounting of Cable (above 70 and below 150 sqmm) at Pole, after passing through suitable size of GI Pipe proper clamping and fixing cleating arrangement along with clamping of terminations as per Tata Power-DDL specification and drawing Scope of work exclude supply and erection of Cleat set ST 1000
116 Mounting of Cable (above 150 sqmm) at Pole, after passing through suitable size of GI Pipe proper clamping and fixing cleating arrangement along with clamping of terminations as per Tata Power-DDL specification and drawing Scope of work exclude supply and erection of Cleat set ST 5000
117 Supply, Installation/laying of HDPE Pipe - 125 mmdia (PN-6 PE-80) and sealing of the same for wire/Cable protection as per Tata Power-DDL specification and drawing. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 5000
118 Supply, Installation/laying of HDPE Pipe - 140 mmdia (PN-4 PE-80) and sealing of the same for wire/Cable protection as per Tata Power-DDL specification and drawing .Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 1000
119 Supply, Installation/laying of HDPE Pipe - 140 mmdia (PN-4 PE-63) and sealing of the same for wire/Cable protection as per Tata Power-DDL specification and drawing. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 1000
120 Supply, Installation/laying of HDPE Pipe - 160 mmdia (PN-4 PE-80) and sealing of the same for wire/Cable protection. as per Tata Power-DDL specification and drawing. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 1000
121 Supply, Installation/laying of HDPE Pipe - 160 mmdia (PN-4 PE-63) and sealing of the same for wire/Cable protection as per Tata Power-DDL specification and drawing. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 10000
122 Supply, Installation/laying of HDPE Pipe - 200 mmdia (PN-4 PE-80) and sealing of the same for wire/Cable protection as per Tata Power-DDL specification and drawing. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 1000
123 Making Trenchless ducts with 160 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 2000
124 Making Trenchless ducts with 160 mm dia HDPE pipe (single run) casing using HDD machine including supply of pipe as per IS 4984, PN4 Class PE63 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 20000
125 Making Trenchless ducts with 160 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 10000
126 Making Trenchless ducts with 160 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 2000
127 Making Trenchless ducts with 160 mm dia HDPE pipe (double run) casing using HDD machine including supply of pipe as per IS 4984, PN4 Class PE63 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 20000
128 Making Trenchless ducts with 160 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 2000
129 Making Trenchless ducts with 200 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE80(Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
130 Making Trenchless ducts with 200 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE80(Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
131 Making Trenchless ducts with 200 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
132 Making Trenchless ducts with 200 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
133 Making Trenchless ducts with 200 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE63(Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
134 Making Trenchless ducts with 200 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE63(Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
135 Making Trenchless ducts with 200 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE63 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
136 Making Trenchless ducts with 200 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE63 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
137 Making Trenchless ducts with 125 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 5000
138 Making Trenchless ducts with 125 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 20000
139 Making Trenchless ducts with 125 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE63 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 1000
140 Making Trenchless ducts with 125 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE63 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 1000
141 Making Trenchless ducts with 160 mm dia HDPE pipe (single run) casing Manually including supply of HDPE pipe as per IS 4984, PN4 Class PE80 as per Tata Power-DDL specification and drawing M 5000
142 Making Trenchless ducts with 160 mm dia HDPE pipe (single run) casing manually including supply of pipe as per IS 4984, PN4 Class PE63 as per Tata Power-DDL specification and drawing M 10000
143 Making Trenchless ducts with 160 mm dia HDPE pipe (single run) casing Manually including supply of HDPE pipe as per IS 4984, PN6 Class PE80 as per Tata Power-DDL specification and drawing M 5000
144 Making Trenchless ducts with 160 mm dia HDPE pipe (double run) casing Manually including supply of HDPE pipe as per IS 4984, PN4 Class PE80 as per Tata Power-DDL specification and drawing M 2000
145 Making Trenchless ducts with 160 mm dia HDPE pipe (double run) casing manually including supply of pipe as per IS 4984, PN4 Class PE63 as per Tata Power-DDL specification and drawing M 5000
146 Making Trenchless ducts with 160 mm dia HDPE pipe (double run) casing Manually including supply of HDPE pipe as per IS 4984, PN6 Class PE80 as per Tata Power-DDL specification and drawing M 2000
147 Making Trenchless ducts with 125 mm dia HDPE pipe (single run) casing Manually including supply of HDPE pipe as per IS 4984, PN6 Class PE80 as per Tata Power-DDL specification and drawing M 5000
148 Making Trenchless ducts with 125 mm dia HDPE pipe (double run) casing Manually including supply of HDPE pipe as per IS 4984, PN6 Class PE80 as per Tata Power-DDL specification and drawing M 5000
149 Making Trenchless ducts with 200 mm dia HDPE pipe (single run) casing Manually including supply of HDPE pipe as per IS 4984, PN4 Class PE80 as per Tata Power-DDL specification and drawing M 500
150 Making Trenchless ducts with 200 mm dia HDPE pipe (Double run) casing Manually including supply of HDPE pipe as per IS 4984, PN4 Class PE80 as per Tata Power-DDL specification and drawing M 500
151 Installation of Pre - fabricated Hot dip Galvanized Steel Structure of different sections as per approved drawing and specification of Tata Power-DDL. Scope also includes minor modification/fabrication required as per site condition/ for proper fitting. KG 400000
152 Fabrication and erection of MS Steel Structure including painting (one coat of red oxide & two coats of synthetic/aluminium paint) as per Tata Power-DDL specification / drawing. Scope also includes supply of ISI marked paint. KG 1500000
153 Fabrication & Installation including applying 1 coat of red oxide & 2 coats of synthetic enamel paint(ISI marked), grouting of Jalli/Mesh as per Tata Power-DDL specifications and drawing. Scope of work does not include supply and laying/installation of cement cocrete, brick work, supporting MS Steel Structure and shall be paid as a separate item KG 300000
154 Fixing of GI Nut & Bolts as per Tata Power-DDL specification / drawing. KG 80000
155 Supply, Fabrication & Installation including applying 1 coat of red oxide & 2 coats of synthetic enamel paint(ISI marked), grouting of Jalli/Mesh as per Tata Power-DDL specifications and drawing. Scope of work excluding supply and laying/installation of cement cocrete, brick work, supporting MS Steel Structure and shall be paid as a separate item KG 300000
156 Supply and Installation of Pre - fabricated Hot dip Galvanized Steel Structure of different section as per Tata Power-DDL approved drawing and specification. KG 2000000
157 Supply and Fixing of GI Bolts & Nuts as per Tata Power-DDL specification / drawing. KG 200000
158 Erection of Switch TPN INCOMER (IC) 63 A 415V as per Tata Power-DDL specification / drawing. EA 200
159 Erection of Switch TPN INCOMER (IC) 100 A 415V as per Tata Power-DDL specification / drawing. EA 200
160 Erection of Switch TPN INCOMER (IC) 200 A 415V as per Tata Power-DDL specification / drawing. EA 200
161 Installation of single arm GI pipe bracket for fixing of fitting including bending of Pipe EA 500
162 Installation, Testing and Commissioning of 11kV 3-way Ring Main Unit (O/D) on existing structure as per Tata Power-DDL specification including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 500
163 Installation, Testing and Commissioning of 11kV 3-way Ring Main Unit (I/D) on existing structure as per Tata Power-DDL specification including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 100
164 Installation, Testing and Commissioning of 11kV 4-way O/D Ring Main Unit on existing structure as per Tata Power-DDL specification including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 500
165 Installation, Testing and Commissioning of 11kV 4-way I/D Ring Main Unit on existing structure as per Tata Power-DDL specification including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 100
166 Installation, Testing and Commissioning of 11kV 1-way Ring Main Unit on existing structure as per Tata Power-DDL specification including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 100
167 Trimming of tree branches (per branches) EA 5000
168 Installation of line spacers as per TPDDL specification and drawing. EA 1000
169 Installation of Shackle insulator as per TPDDL specification and drawing. EA 1000
170 Installation of Template for Transformer maintenance Record EA 1000
171 Installation of Bird Cap as per Tata Power-DDL specification / drawing. EA 10000
172 Making of hole at consumer premises for LT Armoured cable support angle EA 2000
173 Grouting of service cable support angle at consumer premises EA 2000
174 Supply and Installation of Tape PVC adhesive 19MMX10M as per Tata Power-DDL specification / drawing. EA 10000
175 Supply, Fabrication and Erection of Aluminum flat 25X1.5 mm and marking cable number, sizes etc for cable tag as per Tata Power-DDL specification / drawing. EA 5000
176 Installation of one lamp point in indoor substation including the supply of 1 lamp holder , 2 board , 1 no. 5 A switch ,8 meter betten and 20 mtr 1cx2.5 sq mm copper pvc insulated wire and other consumables excluding the supply of lamp EA 500
177 Supply, Fabrication and Erection of Feeder identification tag(HT/LT) with marking of Cable/feeder details for over head Cable. As per TPDDL specification & drawing.Marking shall be done with reflective paint. EA 500
178 Supply & Installation of Tie Plastic size 9mmX265mm EA 5000
179 Supply & Installation of Tie Plastic size 4.6mmX286mm EA 2000
180 Installation of Tie Plastic EA 10000
181 Installation of Steel Strap 20mm (Price per Mtr.) as per Tata Power-DDL specification / drawing. M 10000
182 Installation of Buckle for Steel Strap as per Tata Power-DDL specification / drawing. EA 20000
183 Providing and Fixing of Steel Shuttering for excavation of pit for loop in/loop out of Cable M2 400
184 Supply and Fixing of cable Route marker including transportation from site/tent, excavation, refilling, disposing of malba, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing. Scope excludes providing & laying of cement concrete and shall be paid as separate item EA 20000
185 Fixing /installation of Cable Trench Cover as per Tata Power-DDL specification / drawing. EA 2000
186 Making of hole for penetration of Cable from Substation (11 kV/ grid 33 kV or 66 kV) wall and sealing of the cable (Price per hole) as per Tata Power-DDL specification / drawing. EA 500
187 Installation of Fire Extinguisher as per Tata Power-DDL specification / drawing by means of proper hooks clamps etc. as required including providing of grouting material (cement etc.) and painting of hooks/clamps. Scope exclude supply of hook/clamp EA 1000
188 Installation of Fire Bucket as per Tata Power-DDL specification / drawing including supply of sand by means of proper hooks clamps etc. as required (price per bucket). Scope exclude supply of hooks/clamps/MS stand EA 1000
189 Fixing of Rubber Mat as per Tata Power-DDL specification / drawing. EA 500
190 Fixing of First Aid/ Shock treatment Chart as per Tata Power-DDL specification / drawing. EA 500
191 Motorization of RMU (Installation of motor in Existing RMU Schneider / Abb/or any other make including required connection) EA 50
192 Installation of FRTU including GPRS router with proper earthing as per Tata Power-DDL specification / drawing. EA 50
193 Making of plinth foundation for GI octagonal pole up to 9 meter mtr as per Tata Power-DDL specifications and drawing. EA 2000
194 Installation of GI octagonal pole of 10 &11 mtr including foundation bolts and all other required accessories including suitable arm bracket. This excludes making of foundation and S&I of overhead bracket EA 200
195 Making of plinth foundation for GI octagonal pole from 10 meter to 11 mtr as per Tata Power-DDL specifications and drawing. EA 200
196 Excavation of cable trench upto 1075 mm depth & 450 mm width in Ordinary Soil as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 20000
197 Excavation of cable trench upto 1075 mm depth & 450 mm width in Brick Work as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 50000
198 Excavation of cable trench upto 1075 mm depth & 450 mm width in Foot-Path of Tile/Rajasthani Stone/Ordinary Cement as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 10000
199 Excavation of cable trench upto 1075 mm depth & 450 mm width in Ordinary Bitumenous Road as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 10000
200 Excavation of cable trench upto 1075 mm depth & 450 mm width in Dense Carpeted Bitunenous Road up to 200 thick as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI / HDPE Pipe. For each additional cable 50% will be payable against above activity M 15000
201 Excavation of cable trench upto 1075 mm depth & 450 mm width in Dense Carpeted Bitunenous Road 201mm to 300 mm as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 5000
202 Excavation of cable trench upto 1075 mm depth & 450 mm width in Rocky Area as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 5000
203 Excavation of cable trench upto 1075 mm depth & 450 mm width in RCC up to depth of 300 mm road as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 2000
204 Excavation of cable trench upto 975 mm depth & 450 mm width in Ordinary Soil as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 20000
205 Excavation of cable trench upto 975 mm depth & 450 mmwidth in Brick work as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 1000
206 Excavation of cable trench upto 975 mm depth & 450 mm width in Foot-Path of Tile/Rajasthani Stone/Ordinary Cement as per Tata Power-DDLdrawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 1000
207 Excavation of cable trench upto 975 mm depth & 450 mmwidth in Ordinary Bitumenous Road as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI / HDPE Pipe. For each additional cable 50% will be payable against above activity M 20000
208 Excavation of cable trench upto 975 mm depth & 450 mm width in Dense Carpeted Bitunenous Road up to 200 mm as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 35000
209 Excavation of cable trench upto 975 mm depth & 450 mm width in Dense Carpeted Bitunenous Road 201mm to 300 mm as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 30000
210 Excavation of cable trench upto 975 mm depth & 450 mm width in Rockey Area as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 1000
211 Excavation of cable trench upto 975 mm depth & 450 mm width in RCC up to depth of 300 mm road as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 1000
212 Digging (150 cm x 60 cm) test pit in Soft Soil for locating lillo and identifying faulty cable. Scope also includes back filling, ramming, leveling and removal of malba after jointing. (If it is used in trenchless, only unsucessful test pit will be payable) EA 500
213 Digging (150 cm x 60 cm) test pit in Bricks/Foothpath for locating lillo and identifying faulty cable. Scope also includes back filling, ramming, leveling and removal of malba after jointing. (If it is used in trenchless, only unsucessful test pit will be payable) EA 500
214 Digging (150 cm x 60 cm) test pit in Carpet Road for locating lillo and identifying faulty cable. Scope also includes back filling, ramming, leveling and removal of malba after jointing. (If it is used in trenchless, only unsucessful test pit will be payable) EA 500
215 Digging (150 cm x 60 cm) test pit in CC/Dence Carpeted bituminous for locating lillo and identifying faulty cable.Scope also includes back filling, ramming, leveling and removal of malba after jointing. (If it is used in trenchless, only unsucessful test pit will be payable) EA 1000
216 Breaking of Asphalt/Concrete for Pole / Stay/ Earthing Pit including supply of blasting material if any required M2 10000
217 Cutting/dismantling of RCC/PCC/Carpet road up to 450mm depth for excavation of pit for Installation of Pole/Stay set etc. (Depending upon site conditions) EA 1000
218 Cutting/dismantling of RCC/PCC/Carpet road above 450 mm depth for excavation of pit for Installation of Pole/Stay set etc. (Depending upon site conditions) EA 500
219 Demolishing cement concrete manually/ by mechanical means including disposal of material as per direction of Engineer-in-charge M3 5000
220 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material as per direction of Engineer-in-charge. M3 5000
221 Removal & disposal of Debris of other agency (Not applicable where removal and desposal is mentioned in the item rate) M3 5000
222 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqmm on plan including disposal of excavated earth for all kinds of soil M2 200
223 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth as per direction of EIC for all kinds of soil. M3 1000
224 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed by EIC for all kinds of soil M3 500
225 Filling available excavated earth (excluding rock) trenches, plinth, sides of foundations etc. layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming watering M3 5000
226 Supplying and filling in plinth with Jamuna sand under floors including, watering, ramming, consolidating and dressing complete. M3 500
227 Supplying & filling of earth or ordinary soil excavated and brought from outside without any contents of inorganic materials boulders, etc. M3 1000
228 Supply and laying of sand in substation cable trench (where it is not included in the scope) M3 1000
229 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size). M3 1000
230 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (Zone - III) : 4 graded stone aggregate 20 mm nominal size) M3 5000
231 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size). M3 1000
232 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (Zone - III) : 6 graded stone aggregate 20 mm nominal size). M3 1000
233 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (Zone - III) : 8 graded stone aggregate 40 mm nominal size). M3 1000
234 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size) M3 500
235 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work upto plinth level b) 1:2:4 (1cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size. M3 500
236 Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. M2 500
237 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) M3 500
238 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) M3 500
239 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) M3 200
240 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) M3 1000
241 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all levels. Thermo-Mechanically TrEAted bars. KG 4000
242 15 mm cement plaster on the rough side of single or half brick wall of mix for all heights: 1:4 (1 cement: 4 fine sand) M2 2000
243 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) M2 1000
244 15 mm cement plaster on the rough side of single or half brick wall of mix for all heights: 1:4 (1 cement: 4 coarse sand) M2 2000
245 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) M2 1000
246 12 mm cement plaster of mix for all heights: 1:4 (1 cement: 4 fine sand) M2 2000
247 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) M2 1000
248 12 mm cement plaster of mix for all heights: 1:4 (1 cement: 4 coarse sand) M2 1000
249 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) M2 2000
250 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement- 12 mm cement plaster M2 1000
251 6 mm cement plaster of mix for all heights: 1:3 (1 cement: 3 fine sand) M2 1000
252 Neat cement punning as per Tata Power-DDL specifcation. Scope includes supply of cement M2 2000
253 Transportation of various items from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area - Trolla with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like, Rail Pole, PCC Pole, HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately. EA 500
254 Transportation of various items from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area - Full body Truck with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately EA 1000
255 Transportation of various items from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area - Tempo 709 with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately EA 5000
256 Transportation of various items from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area - Tempo 407 with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately EA 5000
257 Transportation of various items from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area - Three wheeler/Vikram with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately EA 5000
258 Loading, transportation and Unloading of PSCC Pole up to 9m long from Tata Power-DDL store/site to other site or vice versa (above 6 km ) - price per Pole. EA 1000
259 Loading, transportation and Unloading of PSCC Pole above 9m long from Tata Power-DDL store/site to other siteor vice versa (above 6 km) - price per Pole. EA 1000
260 Loading, transportation and Unloading of Rail Pole from Tata Power-DDL store/site to other site or vice versa (up to 6 km) - price per Pole. EA 20
261 Loading, transportation and Unloading of Rail Pole from Tata Power-DDL store/site to other site or vice versa (above 6 km) - price per Pole. EA 20
262 Dismantling of 11 Mtr. PCC Pole(Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 3km /BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 2000
263 Dismantling of 11 Mtr. PCC Pole(Broken Pole) after digging the pit and taking out the pole, refilling the pit with loose earth and ramming. Scope also includes removal & disposal of malba along with dismantled part of pole at proper location as per instruction of EIC EA 10000
264 Dismantling of 9 Mtr. PCC Pole(Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 3km /BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 2000
265 Dismantling of 9 Mtr. PCC Pole(Broken Pole) after digging the pit and taking out the pole, refilling the pit with loose earth and ramming. Scope also includes removal & disposal of malba along with dismantled part of pole at proper location as per instruction of EIC EA 10000
266 Dismantling of steel tublar Pole after digging the pit and taking out the pole as per Tata Power-DDL practice, transportation and staking of pole at proper place in safe position within 3 km/BA site store and refilling pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 200
267 Dismantling of M.S Rail Pole after digging the pit and taking out the pole as per Tata Power-DDL practice, transportation and staking of pole at proper place in safe position within 3 km/BA site store and refilling pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 40
268 Dismantling of existing 11/0.4kV, 990/1000kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
269 Dismantling of existing 11/0.4kV, 630kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 500
270 Dismantling of existing 11/0.4kV, 500kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 150
271 Dismantling of existing 11/0.4kV, 400kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 300
272 Dismantling of existing 11/0.4kV, 315kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 300
273 Dismantling of existing 11/0.4kV, 250kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 800
274 Dismantling of existing 11/0.4kV, 160kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 800
275 Dismantling of existing 11/0.4kV, 100kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 800
276 Dismantling of existing 11/0.4kV, 63kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 500
277 Dismantling of existing 11/0.4kV, 25kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
278 Dismantling of existing 11/0.4kV, 16kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
279 Dismantling of existing 6.3/0.24kV, Three 16 kVA single Phase Distribution Transformer(DT Bank) including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
280 Dismantling of existing 6.3/0.24kV, Three 10 kVA single Phase Distribution Transformer(DT Bank) including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
281 Dismantling of existing 6.3/0.24kV, Three 25 kVA single Phase Distribution Transformer(DT Bank) including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
282 Dismantling of existing 6.3/0.24kV, 25kVA Single Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
283 Dismantling of existing 6.3/0.24kV, 16kVA Single Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
284 Dismantling of existing 6.3/0.24kV, 10kVA Single Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 500
285 Dismantling of existing 11/0.4kV, 630kVA thee phase Package sub station including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 10
286 Dismantling of existing 11/0.4kV, 400 kVA thee phase Package sub station including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 10
287 Dismantling of 11kV, CT/PT Unit along with HT metering system and HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
288 Dismantling of Metering Cubicle including removal HT/LT lead, earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
289 Dismantling of LT Distribution Box suitable for 400/500 kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 100
290 Dismantling of LT Distribution Box suitable for 315kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 100
291 Dismantling of LT Distribution Box suitable for 250kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
292 Dismantling of LT Distribution Box suitable for 160kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
293 Dismantling of LT Distribution Box suitable for 100kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
294 Dismantling of LT Distribution Box suitable for 63kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
295 Dismantling of LT Distribution Box suitable for 25kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
296 Dismantling of LT Distribution Box suitable for 16kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
297 Dismantling of ACB-400A including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
298 Dismantling of ACB-800A including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 50
299 Dismantling of ACB-1250A including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 50
300 Dismantling of ACB-2000A and above including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
301 Dismantling of Feeder Pillar Type -A/B including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
302 Dismantling of Service Pillar including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
303 Dismantling of LT Distribution Box with accessories including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
304 Dismantling of Moulded Bus Bar Box including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
305 Dismantling of 11 kV Single Panel from Kiosk/Indoor/ Outdoor including their safe removal and dragging out. The scope of work also includes the removal of all the Electric/Earth connections but exclude loading/unloading. EA 100
306 Dismantling of 11 kV RMU (Smart/Non-smart) from Kiosk/Indoor/ Outdoor including their safe removal and dragging out. The scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store . EA 400
307 Dismantling of ACSR Wolf conductor, recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 5000
308 Dismantling of ACSR DOG conductor from over head line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 500000
309 Dismantling of ACSR Rabbit conductor from over head line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 200000
310 Dismantling of ACSR Racoon conductor from over head line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 100000
311 Dismantling of ACSR Weasel/Squirell and other smaller size conductor from over head line , recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 100000
312 Dismantling of HT AB Cable 3CX95+1CX95 sqmm from over head line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 100000
313 Dismantling of HT AB Cable 3CX150+1CX150 sqmm from over head recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store M 100000
314 Dismantling of HT AB Cable 1CX95+1CX55 sqmm from over head line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 50000
315 Dismantling of HT AB Cable 1CX150+1CX155 sqmm from over head recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store M 50000
316 Dismantling of LT AB Cable 3C X 70 + 1C X 75 SQMM + 1 X 16sqmm from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store M 50000
317 Dismantling of LT AB Cable 3C/4C X 150 + 1C X 55 SQMM + 1 X 16sqmm from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store M 100000
318 Dismantling of existing LT/HTPVC/ XLPE/Armoured Cable of size up to 35sqmm including making of coil, rebound on drum, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 500000
319 Dismantling of existing LT/HTPVC/ XLPE/Armoured Cable of size above 35 to 70sqmm including making of coil, rebound on drum, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 100000
320 Dismantling of existing LT/HTPVC/ XLPE/Armoured Cable of size above 70 to 150sqmm including making of coil, rebound on drum, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 20000
321 Dismantling of existing LT/HTPVC/ XLPE/Armoured Cable of size above 150sqmm including making of coil, rebound on drum, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 20000
322 Dismantling of 11 kV GOAB Switch including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
323 Dismantling of 11 kV Three Phase DD Fuse Unit (price per set) including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
324 Dismantling of 11 kV Single Phase DD Fuse Unit including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
325 Dismantling of LA including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 5000
326 Dismantling of Anti Climbing Device including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 5000
327 Dismantling of Danger Board including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 5000
328 Dismantling of HT AL Bus bar mounted on 11kV insulator with re-openable insulation cover including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 50
329 Dismantling of 11kV Pin Insulator with Pin including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 5000
330 Dismantling of 11kV Disc Insulator with Hardware including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
331 Dismantling of Suspension Clamp including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 2000
332 Dismantling of Dead End Clamp including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
333 Dismantling of Eye Hook including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 3000
334 Dismantling of Insulated Piercing Connectors including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 5000
335 Dismantling of Clamps and Connectors- Mini Wedge connector/C Wedge connector/PG Clamp/T Clamp including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
336 Dismantling of the G.I.Wire 7/8 SWG as per standard practice of Tata Power-DDL including recoiling loading, transportation, unloading and staking at a proper place in safe position/BA site store M 20000
337 Dismantling of the G.I.Wire 7/10 SWG as per standard practice of Tata Power-DDL including recoiling loading, transportation, unloading and staking at a proper place in safe position/BA site store M 40000
338 Dismantling of the G.I.Wire 4 SWG as per standard practice of Tata Power-DDL including recoiling loading, transportation, unloading and staking at a proper place in safe position/BA site store M 50000
339 Dismantling of the G.I.Wire 6 SWG as per standard practice of Tata Power-DDL including recoiling loading, transportation, unloading and staking at a proper place in safe position/BA site store M 10000
340 Dismantling of the G.I.Wire 8 SWG as per standard practice of Tata Power-DDL including recoiling loading, transportation, unloading and staking at a proper place in safe position/BA site store M 50000
341 Dismantling of the G.I.Wire 16 SWG as per standard practice of Tata Power-DDL including recoiling loading, transportation, unloading and staking at a proper place in safe position/BA site store M 100
342 Dismantling of Steel Structure and Nuts and Bolt including loading, transportation, unloading and staking of dismanled material at a proper place in safe position/BA site store KG 500000
343 Dismantling of Cable Route Marker after digging the pit and taking out, transportation and stacking at a proper place in safe position BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 200
344 Dismantling/Removal of all hardware fittings & Insulator etc. from LT Single Pole including loading, transportation, unloading and staking of dismanled material at a proper place in safe position/BA site store (price per Pole) EA 1000
345 Dismantling/Removal of all hardware fittings & Insulator etc. from HT Single Pole including loading, transportation, unloading and staking of dismanled material at a proper place in safe position/BA site store (price per Pole) EA 1000
346 Dismantling/Removal of all hardware fittings & Insulator etc. from Double Pole Structure including loading, transportation, unloading and staking of dismanled material at a proper place in safe position/BA site store (price per DP) EA 500
347 Dismantling/Removal of all hardware fittings & Insulator etc. from Triple Pole Structure including loading, transportation, unloading and staking of dismanled material at a proper place in safe position/BA site store (price per TP Structure) EA 100
348 Dismantling/Removal of all hardware fittings & Insulator etc. from Four Pole Structure including loading, transportation, unloading and staking of dismanled material at a proper place in safe position/BA site store EA 50
349 Dismantling of ICTPN/MCCB based Switches of all sizes in the I/D S/STN. Includingtheir safe removal and stacking at tent site. EA 200
350 Dismantling of existing Street Light fixture and loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 2000
351 Dismantling of Fencing structure and loading, transportation, unloading and staking at a proper place in safe position/BA site store M2 5000
352 Dismantling of motor from Existing RMU Schneider / Abb/any other make including removal of all connections EA 50
353 Dismantling of FRTU including GPRS router and earthing as per Tata Power-DDL specification / drawing. EA 200
354 Dismantling of UPS & GPRS router for the FPI sites EA 100
355 Installation, testing and commissioning of 12 meter high mast light along with installation of flood light and all other activities associated or incidental thereto as per tpddl specification & drawing EA 10
356 Installation, testing and commissioning of 16 meter high mast light along with installation of flood light and all other activities associated or incidental thereto as per tpddl specification & drawing EA 10
357 Installation, testing and commissioning of 20 meter high mast light along with installation of flood light and all other activities associated or incidental thereto as per tpddl specification & drawing EA 10
358 Installation, testing and commissioning of 990/1000 kVA packaged substation as per tpddl specification & drawing EA 20
359 Installation, testing and commissioning of 630 kVA packaged substation as per tpddl specification & drawing EA 20
360 Installation, testing and commissioning of 400 kVA packaged substation as per tpddl specification & drawing EA 20
361 Transportation of PSS from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area. Scope of work also include loading and unloading with crane. EA 80
362 Installation, Testing (Insulation resistance , Voltage/Turn Ratio , Magnetizing Current and series lamp Test ) and Commissioning of 6.3/0.24 kV, 50 kVA 1-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 200
363 Installation of HDPE Pipe - 32mmdia and sealing of the same for wire/Cable protection as per tpddl specification. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 5000
364 Laying ,testing & commissioning of 11kV Armoured XLPE AL Cable of size 1CX630 sqmm in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 2000
365 Dismantling of existing 6.3/0.24kV, 50kVA Single Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 50
366 Dismantling of existing fencing & then installation of same fencing which includes- dismantling of civil work, de-grouting of fencing legs from tow wall, de-welding of jali/ mesh etc.,Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials, civil work including grouting of fencing legs, welding of jail/ mesh, cutting , painting with primer/ paint. RM 500
367 Installation testing and commissioning of ACDB for 630 KVA DT for single incoming on existing structure as per tpddl specification & drawing. EA 10
368 Installation testing and commissioning of ACDB for 630 KVA DT for double incoming on existing structure as per tpddl specification & drawing. EA 50
369 Installation testing and commissioning of ACDB for 990 KVA DT for single incoming on existing structureas per tpddl specification & drawing. EA 10
370 Installation testing and commissioning of AC DB for 990 KVA DT for double incoming on existing structure as per tpddl specification & drawing. EA 50
371 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 2CX16 sqmm as per Tata Power-DDL specification & drawing m 300000
372 Stringing/Laying of 1.1kV XLPE insulated PVC sheathed AL conductor Cable of size 2CX25 sqmm as per Tata Power-DDL specification & drawing m 1000
373 Connections of Street Light Fitting with 2C*25 Sqmm cable as per tpddl specification & drawing. EA 1000
374 Laying ,testing & commissioning of 11kV Co-extruded cable of size 3CX400 sqmm along with trenchless without HDPE pipe for Double run. (This item includes the Trenchless activity with HDD Machine along with supply of bentonite powder) as per tpddl specification & drawing M 200000
375 Providing & Laying C.C in brick ballast in 1:6:12 (1 Cement : 6 Coarse Sand : 12 Brick aggregate) mix M3 5000
376 Supplying and applying pre tested and approved water based concrete curing compound to concrete/ masonry surface, all as per manufacturer’s specification and direction of Engineer-in-charge. Non pigmented wet curing compound M2 2000
377 Supplying, laying & spreading machine crushed 20 mm good quality blue colour stone aggregates including compacting the same. M3 1000
378 Installation/Erection of 11 Mtr. spun Pole -1000kG including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete, Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) EA 20
379 Installation/Erection of 11 Mtr. spun Pole-750kG including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete, Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) EA 20
380 Installation/Erection of 11 Mtr. spun Pole-500 kG including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete, Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) EA 100
381 Installation/Erection of 11 Mtr. spun Pole-250 kG including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete, Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) EA 20
382 Cage Welding for single phase & three phase transformers (each) after installation, testing and commissioning and shall be as per requirement/recommendation of project incharge EA 100
383 Installation, Testing and Commissioning of 11kV 5-way I/D Ring Main Unit on existing structure as per Tata Power-DDL specification & drawing including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 50
384 Installation, Testing and Commissioning of 11kV 5-way O/D Ring Main Unit on existing structure as per Tata Power-DDL specification & drawing including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 50
385 Installation, Testing and commissioning of 11kV Pole Mounted Breaker Unit on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection. EA 100
386 Installation, Testing and commissioning of 11kV trip saver Unit on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection. EA 50
387 Installation, Testing and commissioning of 11kV intellirupter unit on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection. EA 50
388 Installation, Testing and commissioning of 11kV auto reclosure Unit on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection. EA 100
389 Installation, Testing and commissioning of 11kV sectionaliser Unit on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection. EA 100
390 Installation, testing and commissioning of 400 kVA compact substation (CSS) as per Tata Power-DDL specification & drawing EA 6
391 Installation, testing and commissioning of 250 kVA unitised substation (USS) as per Tata Power-DDL specification & drawing EA 6
392 Installation, testing and commissioning of 400 kVA unitised substation (USS) as per Tata Power-DDL specification & drawing EA 6
393 Installation, testing and commissioning of 630 kVA unitised substation (USS) as per Tata Power-DDL specification & drawing EA 10
394 Route surveying of the cable route with the help of Geograhic Position Rradar (GPR)/any better geo scanning device for cables, OFC, sewer, water or any other services to ensure safety of these services/utilities while cable laying.The map after GPR survey to be submitted to Tata Power-DDL for review and approval. it is imperative that any damage to the utilities shall be on BA's account. BA should liason with Civic agencies ,IGL, DJB, Telecom , Gail and arrange to coduct the GPR for the Cable and other infrastructure and to identify the safe route for cable laying . M 800000
395 Supply, testing and installation of earthing with earth enhancement material (of approved make) through 40mm dia 3 Mtr long Heavy Class GI Pipe, earth clamp, earth pit chamber, cover and connection arrangement for connection to equipment. This includes backfilling and site restoration. The work shall be done as per TPDDL specification and drawings/design where in the resistance is not achieved through normal earthing. Prior approval is required from Engineer in charge. Scope excludes supply of GI pipe. EA 100
396 Providing services for shoring with planks for excavation depth more than 1.8M in joint pits/trench. SQM 200
397 Laying ,testing & commissioning of 11kV Armoured XLPE AL Cable of size 1CX630 sqmm in excavated trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC.(from grid substation to RMU) M 5000
398 Painting on MS Steel Structure/surface (one coat of red oxide & two coats of synthetic/aluminium paint) as per Tata Power-DDL specification / drawing. Scope also includes supply of ISI marked paint as per Tata Power-DDL specification & approved make. M2 2000
399 Installation of SMC/Nylon cleat - single hole type (as per Tata Power-DDL specification & drawing), along with GI hardware (25 mm X 6 mm) clamps for fixing cable. EA 5000
400 Installation of SMC/Nylon cleat - four hole type (as per Tata Power-DDL specification & drawing), along with GI hardware (25 mm X 6 mm) clamps for fixing cable. EA 5000
401 Supply, installation of SMC/Nylon cleat - single hole type (as per Tata Power-DDL specification & drawing), along with GI hardware (25 mm X 6 mm) clamps for fixing cable. EA 2000
402 Supply, installation of SMC/Nylon cleat - four hole type (as per Tata Power-DDL specification & drawing), along with GI hardware (25 mm X 6 mm) clamps for fixing cable. EA 2000
403 Installation, Testing and Commissioning of 11kV metering cubicle with RMU on existing structure as per Tata Power-DDL specification including grouting, loading, unloading, shifting/transportation from site/tent to place of installation. This item does not include earthing, jumpering/connection and construction of the foundation.if required, to be done shall be paid separately. EA 20
404 Sign writing on Pole/pipe/cable/Sub Station and other equipment (not installed by BA) at suitable height as per requirement and direction of engineer in charge with synthetic enamel paint of berger/asian or approved make including preparation of back ground with two or more coats of yellow paint with primer to ensure uniform surface in following sizes. All tools, tackles and other equipments for carrying out the work are to be arranged by the BA. (This item shall be paid only for already erected pole/old Pole). For new pole & ITC of the pole is in bidder scope then this item shall not be payable. EA 500
405 Rectification/Straightening of tilted pole in all respect including New Gen Hydra/ Crane as the case may be. EA 200
406 String of 1.1 KV XLPE insulated AL conductor AB Cable of size 2Cx25 Sqmm + 1Cx25sqmm as per TPDDL specification including testing of cable M 2000
407 SITC of BOBIN Insulator as per tpddl specification & drawing EA 200
408 Supply & Installation of copper wire 3cx4 sqmm including all assecessries used for termination also. M 200
409 Supply & Installation of thimble 4 mm copper EA 200
410 Dismantling of 11kV Auto Reclosure Unit from existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. EA 50
411 Dismantling of 11kV Sectionalizer Unit from existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. EA 50
412 Dismantling of 11kV Pole mounted breaker from existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. EA 10
413 Dismantling of 11kV trip saver Unit on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. EA 20
414 ITC-Animal guard on DT HT bushing as per tpddl specification and drawing EA 2000
415 ITC-SMC/Nylon cleat on LV cable of DT as per TPDDL specification and drawing EA 500
416 Fixing of Bird spike with suitable cap as per TPDDL specification and drawing EA 10000
417 Installation of RFID tag as per TPDDL specification and drawing for 11 kv cable laying EA 20
418 ITC of monkey scare as per TPDDL specification and drawing EA 200
419 SITC of Safety awareness board that shall be installed on fencing of all 11 KV substations & other relevant locations as per TPDDL drawing. EA 2000
420 Fixing of insulation sleeve/Polypro/Polyolefin as per TPDDL specification and drawing M 5000
421 Mounting of CCD Cable at Pole, after passing through suitable size of GI Pipe with proper clamping and fixing of cleating arrangement along with clamping of terminations as per Tata Power-DDL specification and drawing. Scope of work exclude supply and erection of Cleat set. Scope of work includes painting on (CCD) i.e. co-extruded 11 KV cable with fire retardant paint as per TPDDL specification and drawing, up to 2 meter from termination end, as per instruction of engineer in charge. EA 500
422 Supplying & Installation, testing and commissioning of 12 meter high mast light with 6 luminaries of 200W LED (1 complete set) along with installation of flood light and all other activities associated or incidental thereto as per tpddl specification & drawing ST 10
423 Supplying &Installation, testing and commissioning of 16 meter high mast light with 9 luminaries of 200W LED (1 complete set) along with installation of flood light and all other activities associated or incidental thereto as per tpddl specification & drawing ST 10
424 Supplying & Installation, testing and commissioning of 20 meter high mast light with 12 luminaries of 200W LED along with installation of flood light and all other activities associated or incidental thereto as per tpddl specification & drawing ST 10
425 ITC-Cantilever based GO mechanism EA 100
426 Making Trenchless ducts with Coextruded cable (single run) casing Manually including laying of Cable M 5000
427 Installation of Outdoor Type Distribution Box with MCCB, 63A on existing structure as per Tata Power-DDL specification and drawing. EA 100
428 Installation of Outdoor Type Distribution Box with MCCB, 100A on existing structure as per Tata Power-DDL specification and drawing. EA 100
429 Installation of Outdoor Type Distribution Box with MCCB, 125A on existing structure as per Tata Power-DDL specification and drawing. EA 100
430 Installation of Outdoor Type Distribution Box with MCCB, 250A on existing structure as per Tata Power-DDL specification and drawing. EA 100
431 Installation of Outdoor Type Distribution Box with MCCB, 400A on existing structure as per Tata Power-DDL specification and drawing. EA 100
432 Installation of Outdoor Type Distribution Box with MCCB, 500A on existing structure as per Tata Power-DDL specification and drawing. EA 100
433 Installation of 100/125/150 mm dia GI Pipe for Cable protection as per Tata Power-DDL specification & drawing M 5000
434 Laying of GI Pipe -100/125/150/ 200mm dia and sealing of the same for Laying LT/HT Cables. Scope aIso includes providing and laying all required consumable etc. for sealing of Pipe as per Tata Power-DDL specification & drawing (Excavation is excluded) M 5000
435 Installation of HDPE Pipe - 25 mm dia and sealing of the same for wire/Cable protection. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe as per Tata Power-DDL specification & drawing M 40000
436 Laying testing & commissioning of 11kV Armoured XLPE AL Cable/CCD Cable 3CX400/ 3X300 sqmm in already laid GI Pipe/Hume Pipe/ HDPE/ PVC Pipe (Any Size) as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude fixing of HDPE Pipe, Hume Pipe, GI Pipe, PVC Pipe M 30000
437 Stringing/Laying of 1.1kV XLPE insulated PVC sheathed AL conductor Cable of size 1CX2.5/4/16/25 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 2000
438 Crimping and Fixing/connecting to terminal of AL Lugs 16 sqmm as per Tata Power-DDL specification and drawing EA 1000
439 Only Testing of 11kV any Switchgear panels(RMU/Autoreclosure/Pole mounting Breaker etc.) on existing structure as per Tata Power-DDL specification Scope of work excludes earthing, jumpering/connection and construction of foundation EA 100
440 Supply & Fixing of Epoxy resin hardner "M-seal- Pidilite Mark" as per Tata Power-DDL specification / drawing, including consumable(300gm / hole to be use) Price per one hole EA 1000
441 Fixing of cable Route marker including transportation from site/tent, excavation, refilling, disposing of malba, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing. Scope excludes providing & laying of cement concrete and shall be paid as separate item EA 1000
442 Supply and Fixing /installation of Cable Trench Cover as per Tata Power-DDL specification / drawing. EA 500
443 Assistance for installation of FRTU as per Tata Power-DDL specification / drawing. EA 20
444 Transportation of various items from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area - E-RICKSHAW with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately EA 1000
445 Loading of HT panel,Transformer, LT board, Cable drum with crane or tripode Per truck/tempo (Price per HT panel,Transformer, LT board, Cable drum) EA 2000
446 Unloading of HT panel,Transformer, LT board, Cable drum with crane or tripode Per truck/tempo (Price per HT panel,Transformer, LT board, Cable drum ) EA 2000
447 Dismantling of upto 150 mm Dia GI Pipe including loading, transportation, unloading and staking at a proper place in safe position/BA site store M 5000
448 Transportation of USS from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area. Scope of work also include loading and unloading with crane. EA 30
449 Laying ,testing & commissioning of 11kV Armoured XLPE AL Cable of size 1CX630 sqmm in existing s/s trench/already laid HDPE/Hume/RCC/GI pipe. M 5000
450 Connections of Street Light Fitting with 2C*2.5 Sqmm cable as per tpddl specification & drawing. EA 500
451 Laying ,testing & commissioning of 11kV Co-extruded cable of size 3CX400 sqmm along with trenchless without HDPE pipe for Triple run. (This item includes the Trenchless activity with HDD Machine along with supply of bentonite powder) as per tpddl specification & drawing M 40000
452 Assistance of DT smart meter Installation. The work shall be done under supervision of Protection team. EA 200
453 Dismantling of 11kV Intellirupter Unit on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. EA 50
454 Removal of dense vegetation/grass etc as per the direction of Engineer incharge M2 1000
455 Installation/Erection of 11 Mtr. Bundled Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 400
456 Installation/Erection of 9 Mtr. Bundled Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 200
457 Interlocking Paver Block Providing & laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction ,of approved size,design & shape ,laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand,filling the joints with line sand. all complete as per direction of Engineer in charge M2 2000
458 Installation of Flying stay including supply material EA 100
459 Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and paint all complete. KG 20000
460 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and paint all complete. KG 200000
461 De-watering of pole pit with the help of pump/submersible motor. (This service shall be given after HOD - DP Approval) EA 1000
462 SITC of 16 mm Al wire for earthing M 1000
463 SITC of 16 mm Al Lug for earthing EA 1000
464 SITC of Jubliee clamp EA 1000
465 Installation of flat type eye hook EA 100
466 Dismantling of 11 Mtr. Spun Pole(Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 3km /BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 50
467 Dismantling of 11 Mtr. Spun Pole(Broken Pole) after digging the pit and taking out the pole, refilling the pit with loose earth and ramming. Scope also include crushing of broken Pole and removal & disposal of malba at proper location as per instruction of EIC EA 50
468 Dismantling of 9 Mtr. Spun Pole(Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 3km /BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 50
469 Dismantling of 9 Mtr. Spun Pole(Broken Pole) after digging the pit and taking out the pole, refilling the pit with loose earth and ramming. Scope also include crushing of broken Pole and removal & disposal of malba at proper location as per instruction of EIC EA 50
470 Dismantling of 11 Mtr. bundled Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 3km /BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 100
471 Dismantling of 11 Mtr. bundled Pole (Broken Pole) after digging the pit and taking out the pole, refilling the pit with loose earth and ramming. Scope also include crushing of broken Pole and removal & disposal of malba at proper location as per instruction of EIC EA 200
472 Dismantling of 9 Mtr. bundled Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 3km /BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 100
473 Dismantling of 9 Mtr. bundled Pole (Broken Pole) after digging the pit and taking out the pole, refilling the pit with loose earth and ramming. Scope also include crushing of broken Pole and removal & disposal of malba at proper location as per instruction of EIC EA 100
474 Making , covering and heat shrinking of cable end by suitable size breakout with earth stip and socketing for cable sizes of 1.1 kV 4X25, 4X50, 4X95, 4X150 and 4X300 sq. mm . EA 100
475 SITC of 70 Watts LED Lamp fittings complete with associated material & Clamps including Bending of pipe (wherever required etc.) as per Tata Power-DDL specification / drawing & approved makes & model. Type test reports to be submitted for GTP approval. EA 200
476 SITC of 150 Watts LED Lamp fittings complete with with associated material & Clamps including Bending of pipe (wherever required etc.) as per Tata Power-DDL specification / drawing & approved makes & model. Type test reports to be submitted for GTP approval. EA 100
477 SITC of 250 Watts LED Lamp fittings complete with with associated material & Clamps including Bending of pipe (wherever required etc.) as per Tata Power-DDL specification / drawing & approved makes & model. Type test reports to be submitted for GTP approval. EA 50
478 SITC of 400 Watts LED Lamp fittings complete with with associated material & Clamps including Bending of pipe (wherever required etc.) as per Tata Power-DDL specification / drawing & approved makes & model. Type test reports to be submitted for GTP approval. EA 50
479 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX25/50/95 sqmm in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
480 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX25/50/95 sqmm (Double run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
481 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX25/50/95 sqmm (Triple run)) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
482 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX25/50/95 sqmm (Quadruple run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
483 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX150 sqmm(Double run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
484 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX150 sqmm( Triple run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
485 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX150 sqmm(Quadruple run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 50000
486 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX300 sqmm(Double run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
487 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX300 sqmm( Triple run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
488 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX300 sqmm(Quadruple run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 50000
489 Supply & Painting on co-extruded 11 KV cable with fire retardant paint as per TPDDL specification and drawing, on exposed parts as per instruction of engineer in charge (per meter length ) M 2000
490 Installation of FRP Fencing(upto height -2050 mm) of substations/RMU as per Tata Power-DDL specification and drawing excluding civil work RM 2000
491 Supply of FRP fencing Pallas/Door as per Tata Power-DDL specification & drawing Sq M 1000
492 Installation of Hybrid Fencing(MS posts & FRP Pallas/Doors) including applying 1 coat of red oxide & 2 coats of synthetic enamel paint(ISI marked) for MS structure, grouting of FRP pallas as per Tata Power-DDL specifications and drawing. Scope of work excluding supply and laying/installation of cement cocrete, brick work, supporting MS Steel Structure and shall be paid as a separate item RM 2000
493 Painting of existing Mesh/jalli Structure both sides with two coats of synthetic paint after surface claening \as per Tata Power-DDL specification / drawing. Scope also includes supply of ISI marked & Approved make of paint. M2 10000
494 Providing heavy labour for shifting of Switchgear Pannel etc. for installation, dragging with chain block, tripod, required accessories, safety PPE etc. (price per Transformer/ Switchgear panel) for distance upto 10 metre EA 200
495 Providing heavy labour for shifting of Switchgear Pannel etc. for installation, dragging with chain block, tripod, required accessories, safety PPE etc. (price per Transformer/ Switchgear panel) for distance more than 10 metre EA 200
496 Supply, Installation/laying of HDPE Pipe -75 mmdia (PN-6 PE-80) and sealing of the same for wire/Cable protection as per Tata Power-DDL specification and drawing. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 2000
497 Installation of 70 Watts street light Fixture/HPMV/HPSV or equivalent alternative LED Lamp fittings complete with Clamps as per Tata Power-DDL specification / drawing. Scope also includes installation of Single arm GI Bracket including bending of pipe EA 2000
498 Installation of 150 Watts street light Fixture/HPMV/HPSV or equivalent alternative LED Lamp fittings complete with Clamps including as per Tata Power-DDL specification drawing. Scope also includes installation of Single arm GI Bracket including bending of pipe EA 3000
499 Installation of 250 Watts street light Fixture/HPMV/HPSV or equivalent alternative LED Lamp fittings complete with Clamps as per Tata Power-DDL specification / drawing. Scope also includes installation of Single arm GI Bracket including bending of pipe EA 2000
500 Installation of 400 Watts street light Fixture/HPMV/HPSV or equivalent alternative LED Lamp fittings complete with Clampsas per Tata Power-DDL specification / drawing. Scope also includes installation of Single arm GI Bracket including bending of pipe EA 1000
501 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 990/1000kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification and drawing including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side. EA 200
502 Installation of GI octagonal pole of up to 5 mtr including foundation bolts and all other required accessories including suitable arm bracket. This excludes making of foundation and S&I of overhead bracket EA 1000
503 Installation of GI octagonal pole of length (upto 9 mtr & more than 5 mtr) including foundation bolts and all other required accessories including suitable arm bracket. This excludes making of foundation and S&I of overhead bracket EA 1000
504 Supply & Installation of MCB-6-amp Double pole [ ISI Marked] EA 100
505 Supply & Laying of 1.1KV 3Cx1.5 sq.mm unarmoured cable M 500
506 SITC of 25 mm Dia Flexible pipe for 3x1.5 sqmm wiring in pipe M 500
507 Excavation Up to 1.5m Lift Including Dewatering M3 200
508 Supply & Installation of GI octagonal pole of up to 5 mtr including foundation bolts and all other required accessories including suitable arm bracket. This excludes making of foundation and S&I of overhead bracket EA 1000
509 Supply & Installation of HDPE Pipe -40 mm dia and sealing of the same for wire/Cable protection as per tpddl specification. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 2000
510 Laying of PVC 50 mm dia and sealing of the same for Laying LT Cables. Scope aIso includes providing and laying all required consumables etc. for collar fixing and sealing of Pipe as per Tata Power-DDL specification & drawing (Excavation is excluded) M 1000
511 Supply & installation of PVC special type of sleeve 3M per pole for 4C*25sqmm cable in pole junction box as per tata power-ddl specification & drawing M 50
512 Supply & Installation of HDPE Pipe -50 mm dia and sealing of the same for wire/Cable protection as per tpddl specification. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 2000
513 Installation of 40/50/75 mm dia GI Pipe for earth wire/Cable protection as per Tata Power-DDL specification & drawing M 1000
514 Laying testing & commissioning of 11kV Armoured XLPE AL Cable/CCD cable in S/Sth. Trench/Tray as per Tata Power-DDL specification & drawing including testing of cable. Scope of work excludes Painting on CCD cable with fire retardant paint as per TPDDL specification, M 10000
515 Making of new foundation for 3-way/4-way/ 5 way RMU (Non-smart) RMU including excavation for foundation and supply of raw material i.e. sand,badarpur, cement, bricks and removal of malba if any as per siterequirement including labour required for the same (PCC 1:4:8/ as persite requirement). Scope of work includes MS steel structure for foundation as per Tata Power-DDL specification / drawing. EA 500
516 Making of new foundation for 3-way/4-way/ 5 way RMU (Smart) RMU including excavation for foundation and supply of raw material i.e. sand,badarpur, cement, bricks and removal of malba if any as per siterequirement including labour required for the same (PCC 1:4:8/ as persite requirement). Scope of work includes MS steel structure for foundation as per Tata Power-DDL specification / drawing. EA 500
517 Making of new foundation for 1-way RMU (Non-smart) & RN2C including excavation for foundation and supply of raw material i.e. sand,badarpur, cement, bricks and removal of malba if any as per siterequirement including labour required for the same (PCC 1:4:8/ as per site requirement). Scope of work includes MS steel structure for foundation as per Tata Power-DDL specification / drawing. EA 200
518 Making foundation for USS as per Tata Power-DDL drawing & specification including supply of all materials EA 20
519 SITC of fireball EA 50
520 Installation/Erection of 9 Mtr. PSCC Pole (Manually ) including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 1000
521 Installation ,testing of single phase DT manually EA 100
522 Dismantling of Single phase DT manually EA 100
523 Installation of Pre-Cast RMU Plinth as per Tata power DDL specification & drawing.Scope excludes loading,unloading & transportation. EA 300
524 Installation of Pre-Cast DT Plinth block(500 mm height) as per Tata power DDL specification & drawing.Scope includes loading,unloading & transportation. EA 1000
525 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m) having 50 no rounds per 6 metre length, upto 3m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) /Spring core (2.5mm thick) wire of high tensile strength of 165 KG/ sq.mm with tape (0.52 mm thick) and weight 43.478gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) M 2000
526 Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 KG per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately) :-Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire M 10000
527 Installation/Erection of 09 Mtr. PSCC Square Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 500
528 Installation/Erection of 11 Mtr. PSCC Sqare Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 100
529 SITC of Hume pipe of 600mm dia and 2 m length for installation of pole including transportation ,installation,loading and unloading, EA 300
530 Installation/Erection of 9M Two Piece Spun Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, backfilling, flooding with water, ramming/compacting of foundation, setting up & removal of mounting arrangement after installation of upper piece including fixing nuts and bolts complete as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brickbat filling, providing & laying of cement concrete. EA 100
531 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 1600 kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification and drawing including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side. EA 30
532 Installation of Top Hamper Clamp as per TPDDL specification & drawings EA 500
533 Installation of Post Insulator as per TPDDL specification & drawings EA 1000
534 Installation of pre fabricated angle (Slotted angle) EA 1000
535 Installation of FRP Cross Arm as per TPDDL specification & drawings EA 1000
536 Installation, Testing (Insulation Resistance , Voltage/Turn Ratio, , Magnetizing Current and Series Lamp Test) and Commissioning of 6.3/0.24 kV, 10kVA Single Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side. EA 5
537 Installation, Testing (Insulation Resistance , Voltage/Turn Ratio, , Magnetizing Current and Series Lamp Test) and Commissioning of 6.3/0.24 kV,, 16kVA Single Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side. EA 20
538 Installation, Testing (Insulation Resistance , Voltage/Turn Ratio, , Magnetizing Current and Series Lamp Test) and Commissioning of 6.3/0.24 kV, 25kVA Single Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side. EA 75
539 Installation, Testing (Insulation Resistance , Voltage/Turn Ratio, , Magnetizing Current and Series Lamp Test) and Commissioning of 6.3/0.24 kV three single phase transformers(DT Bank) of 10 KVA , on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 2
540 Installation, Testing (Insulation Resistance , Voltage/Turn Ratio, , Magnetizing Current and Series Lamp Test) and Commissioning of 6.3/0.24 kV three single phase transformers(DT Bank) of 16 KVA , on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 2
541 Installation, Testing (Insulation Resistance , Voltage/Turn Ratio, , Magnetizing Current and Series Lamp Test) and Commissioning of 6.3/0.24 kV three single phase transformers(DT Bank) of 25 KVA , on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 2
542 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp test ) and Commissioning of 11/0.4kV, 16kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side. EA 50
543 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 25kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 100
544 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 63kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 200
545 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 100kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 300
546 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 160kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 300
547 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 250kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 300
548 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 315kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 200
549 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 400kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 400
550 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 500kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 400
551 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 630kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 300
552 Laying of PVC Pipe -160/150/ 200 mm dia and sealing of the same for Laying LT/HT Cables. Scope aIso includes providing and laying all required consumables etc. for collar fixing and sealing of Pipe as per Tata Power-DDL specification & drawing (Excavation is excluded) M 250
553 Laying ,testing & commissioning of 11kV Co-extruded cable of size 3CX400 sqmm along with trenchless without HDPE pipe for Single run. (This item includes the Trenchless activity with HDD Machine along with supply of bentonite powder) as per tpddl specification & drawing M 200000
554 Indoor Termination of 11 kV Armoured XLPE, AL Cable 3CX300 sqmm including consumable as per Tata Power-DDL specification & drawing EA 100
555 Outdoor Termination of 11 kV Armoured XLPE, AL Cable 3CX300 sqmm including consumable as per Tata Power-DDL specification & drawing EA 100
556 Indoor Termination of 11 kV Armoured XLPE, AL Cable 3CX400 sqmm including consumable as per Tata Power-DDL specification & drawing EA 1000
557 Outdoor Termination of 11 kV Armoured XLPE, AL Cable 3CX400 sqmm including consumable as per Tata Power-DDL specification & drawing EA 1000
558 Installation of Straight Through Joint KIT of 11kV XLPE Armoured Cable 3Cx400 sqmm including consumable as per Tata Power-DDL specification & drawing EA 3000
559 Installation of Straight Through Joint KIT of 11kV XLPE Armoured Cable 3Cx300 sqmm including consumable as per Tata Power-DDL specification & drawing EA 20
560 Installation of Straight Through Joint KIT of 11kV XLPE Armoured Cable 3Cx150 sqmm including consumable as per Tata Power-DDL specification & drawing EA 20
561 Installation of Straight Through Joint Kit for 1.1 kV XLPE AL Cable 4CX25 sqmm as per Tata Power-DDL specification and drawing EA 100
562 Installation of Straight Through Joint Kit for 1.1 kV XLPE AL Cable 4CX50 sqmm as per Tata Power-DDL specification and drawing EA 20
563 Installation of Straight Through Joint Kit for 1.1 kV XLPE AL Cable 4CX95 sqmm as per Tata Power-DDL specification and drawing EA 20
564 Installation of Straight Through Joint Kit for 1.1 kV XLPE AL Cable 4CX150 sqmm as per Tata Power-DDL specification and drawing EA 20
565 Installation of Straight Through Joint Kit for 1.1 kV XLPE AL Cable 4CX300 sqmm as per Tata Power-DDL specification and drawing EA 500
566 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Hard Rock (Blasting prohibited) M3 129.6
567 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary or hard rock M3 21.6
568 Disposal of all debris/rubbish/malba/surplus excavated earth/similar unserviceable, dismantled or waste materials arising out of demolition and construction activities, by mechanical means, including loading, transporting, unloading to authorized Construction and Demolition (C&D) waste recycling plant or approved municipal dumping ground as per the directions of TPDDL Engineer-in-charge, for all leads including all lifts involved. Bidder solely shall be responsible for identifying such area and bear all costs involved, TPDDL shall not be liable for the same. Bidder shall clear the site thoroughly of such unwanted materials and rubbish etc. left out of his work and dress the site to the satisfaction of the TPDDL Engineer-in-Charge in all respects before the final handing over. Nothing additional shall be paid on account of disposal of waste material to construction and demolition (C&D) waste recycling plant. M3 129.6
569 Supply & Installation of GI octagonal 8 mtr Pole including foundation bolts and all other required accessories including suitable arm bracket. This excludes making of foundation and S&I of overhead bracket EA 1000
570 Supply & Installation of GI octagonal 9 mtr Pole including foundation bolts and all other required accessories including suitable arm bracket. This excludes making of foundation and S&I of overhead bracket EA 1000
S. No. New Item Description UOM Quantity (Q) Unit Price (Rs.) (A) GST (B) All Inc. Price (C) = (A)+(B) All Inc value (D) =(C)*(Q)
1 Installation/Erection of 11 Mtr. PSCC Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 20000
2 Installation/Erection of 9 Mtr. PSCC Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 5000
3 Installation/Erection of 13 m long Rail Pole including loading and unloading, excavation, fixing of base plate, grounting, refilling, disposing & removal of malba, flooding with water, ramming/ compacting of foundation as per Tata Power-DDL specifications and drawing including removal & disposal of malba as per instruction of EIC. Scope of work also includes Pole Indexing, Painting of Pole (In Black & Yellow Strips/Zebra), Painting of Pole with one cote of red oxide and two coats of AL Paint (paint to be supplied by BA of ISI Mark/superior quality). The scope of work excludes, providing & laying of cement concrete. EA 10
4 Painting of Pole In Black & Yellow Strips/Zebra as per Tata Power-DDL specifications and indexing/numbering of Poles as per GIS format, scope also include site survey for GIS indexing and supply of ISI Marked good quality paint. (this item shall be paid for old poles only and where this not mentioned in scope) EA 25000
5 Pole indexing/numbering as per GIS format and Tata Power-DDL specifications including site survey for GIS indexing and supply of ISI Marked good quality paint. (this item shall be paid for old poles only and where this not mentioned in scope) EA 25000
6 Brick betting for Pole foundation including supply of consumables and stengthening as per Tata Power-DDL specification/drawing (Price per pole/foundation) EA 25000
7 Welding of Transformers as per requirement after installation, testing and commissioning (minimum no. of points for weld shall be 4 no. and 5 No. for single phase & three phase transformer each respectively and maximum no. of welds shall be as per requirement/recommendation of project incharge) EA 1000
8 Installation, Testing and Commissioning of 11kV CT PT Unit on existing structure as per Tata Power-DDL specification including installation of Pipe, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection EA 50
9 Installation, Testing and Commissioning of 11kV Metering Cubicle on existing structure as per Tata Power-DDL specification including loading, unloading, shifting /transportation from site/tent. Scope of work excludes earthing, jumpering / connection. EA 200
10 Installation of 11 kV 3- Phase AB/G.O Switch on existing structure including alignment as per Tata Power-DDL specification and drawing EA 1000
11 Installation of 11kV D.O Fuse Single Phase including Fuse Link on existing structure as per Tata Power-DDL specification and drawing EA 500
12 Installation of 11kV D.O. Fuse 3 Phase(Price per Set) including Fuse Link on existing structure as per Tata Power-DDL specification and drawing ST 2500
13 Installation of 11kV LA Single Phase on existing structure as per Tata Power-DDL specification and drawing EA 8000
14 Installation of HT Aluminium Bus Bar mounted on 11 kV insulator with re-openable insulation/cover for holding T-off connector/ termination kits as per Tata Power-DDL specification and drawing EA 500
15 Installation of 11kV Pin Insulator with hardware/PIN as per Tata Power-DDL specification & drawing EA 20000
16 Installation of 11kV Disc Insulator with all hardware fittings as per Tata Power-DDL specification & drawing. EA 1000
17 Installation of Anti-Climbing Device for 11Mtr/9 Mtr Pole as per Tata Power-DDL specification and drawing. EA 25000
18 Installation of HT/LT Danger Board as per Tata Power-DDL specification & Drawing. EA 25000
19 Installation of 2 line cross arm on 9M/11M pole as per Tata Power-DDL specification and drawing. EA 5000
20 Installation of V cross arm on 11 mtr pole as per Tata Power-DDL specification and drawing. EA 2000
21 Fixing of LT Complete Stay Set as per Tata Power-DDL specifications and drawing. The scope of work includes excavation for all type of soils/RCC/Bituminous/ Rocky/ Rajasthani tiles etc., breaking of asphalt, fixing of Base Plate,Anchor road, Tension screw, Egg insulator, back filling removal & disposing of malba as per instruction of EIC etc. but excludes stringing of GI Wire, fabrication works and providing and laying of cement concrete. ST 2000
22 Fixing of HT Complete Stay Set as per Tata Power-DDL specifications and drawing. The scope of work includes excavation for all type of soils/RCC/Bituminous/ Rocky/ Rajasthani tiles etc. , breaking of asphalt, fixing of Base Plate,Anchor road, Tension screw, Egg insulator, back filling removal & disposing of malba as per instruction of EIC etc. but excludes stringing of GI Wire, fabrication works and providing and laying of cement concrete. ST 3500
23 Installation of Outdoor Type Distribution Box with MCCB for 6.3/0.24kV Single Phase Transformer on existing structure as per Tata Power-DDL specification and drawing. EA 20
24 Installation of Outdoor Type Distribution Box with MCCB for 6.3/0.24kV,10kVA Single Phase Transformer on existing structure as per Tata Power-DDL specification EA 2
25 Installation of Outdoor Type Distribution Box with MCCB for 6.3/0.24kV,16kVA Single Phase Transformer on existing structure as per Tata Power-DDL specification EA 2
26 Installation of Outdoor Type Distribution Box with MCCB for 11/0.4kV,25kVA Single Phase Transformer on existing structure as per Tata Power-DDL specification EA 2
27 Installation testing and commissioning of LT ACB 400 Amps with enclosure on existing structure as per Tata Power-DDL specification and drawing. EA 2500
28 Installation testing and commissioning of LT ACB 800 Amps with enclosure on existing structure as per Tata Power-DDL specification and drawing. EA 50
29 Installation testing and commissioning of LT ACB 1250 Amps with enclosure on existing structure as per Tata Power-DDL specification and drawing. EA 50
30 Installation testing and commissioning of LT ACB 2000 Amps with enclosure on existing structure as per Tata Power-DDL specification and drawing. EA 10
31 Installation of LT Distribution Box with bus bars for LT Service connection as per Tata Power-DDL specification and drawing. EA 10000
32 Erection of Feeder Pillar Type - A /B as per Tata Power-DDL specification and drawing on existing Structure/foundation. Scope of work exclude construction of foundation (brick work, concreting etc) and earthing. EA 700
33 Erection of Service Pillar as per Tata Power-DDL specification and drawing on existing Structure/foundation. Scope of work exclude construction of foundation (brick work, concreting etc) and earthing EA 500
34 Installation of 415 V, 3 Phase ICTPN/ MCCB based street light switch Unit including taping there of as required (cable dressing & one end cable termination) EA 500
35 Installation of Eye hook (Bolt type) as per Tata Power-DDL specification and drawing EA 10000
36 Installation of Dead End Clamp for HT/LT AB Cable as per Tata Power-DDL specification and drawing EA 3000
37 Installation of Suspension Clamp for HT/LT AB Cable as per Tata Power-DDL specification and drawing EA 3000
38 Installation of Insulated Piercing Connector as per Tata Power-DDL specification and drawing EA 40000
39 Installation of Clamps & Connectors (Wedge, PG etc.)as per Tata Power-DDL specification and drawing EA 3000
40 Installation of Palm connector as per Tata Power-DDL specification and drawing EA 500
41 Installation of Service main Anchor(Wall corner clamp) as per Tata Power-DDL specification and drawing EA 500
42 Earthing by boring in ordinary soil upto water level (up to 3 Mtr.depth) with fixing of earth Pipe and connecting GI Stay wire 7/8 or 7/10 SWG as per Tata Power-DDL Earthing Philosophy (Each pit resistance will be measured and recorded and shall be within 1-3 ohm). Scope excludes supply of earth pipe, laying of GI Wire and crimping of Lugs. EA 200
43 Earthing by boring in ordinary soil upto water level (above 3m to 6 Mtr.depth) with fixing of earth Pipe and connecting GI Stay wire 7/8 or 7/10 SWG as per Tata Power-DDL earthing philosophy (Each pit resistance will be measured and recorded and shall be within 1-3 ohm). Scope excludes supply of earth pipe, laying of GI Wire and crimping of Lugs. EA 20000
44 Earthing by boring in ordinary soil upto water level (above 6m to 9 Mtr.depth) with fixing of earth Pipe and connecting GI Stay wire 7/8 or 7/10 SWG as per Tata Power-DDL earthing philosophy (Each pit resistance will be measured and recorded and shall be within 1-3 ohm). Scope excludes supply of earth pipe, laying of GI Wire and crimping of Lugs. EA 5000
45 Earthing by boring in ordinary soil upto water level (above 9m to 15 Mtr.depth) with fixing of earth Pipe and connecting GI Stay wire 7/8 or 7/10 SWG as per Tata Power-DDL earthing philosophy (Each pit resistance will be measured and recorded and shall be within 1-3 ohm). Scope excludes supply of earth pipe, laying of GI Wire and crimping of Lugs. EA 1000
46 Installation of GI Strip 50X6 mm for earthing of equipments including welding and painting of joints with black colour as per Tata Power-DDL specification and supply of consumable as required. M 20000
47 Sagging/Stringing/Drawing of GI wire 7/10 or 7/8 SWG for earting of equipments/structure as per Tata Power-DDL specification and drawing. M 800000
48 Sagging/Stringing/Drawing of GI wire 4/6/8 SWG including Jumpering & making of connection hooks etc. as per Tata Power-DDL specification and drawing M 40000
49 Making & Fixing of Guard Lace of G.I. Wire 4/6/8 SWG for HV/LV Line (price per lacing) as per Tata Power-DDL specification & drawing EA 5000
50 Installation of 40 mm dia GI Pipe for earth wire/Cable protection as per Tata Power-DDL specification & drawing M 200
51 Laying of HUME - up to 200mm dia and sealing of the same for Laying LT/HT Cables. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe.as per Tata Power-DDL specification & drawing (Excavation is excluded) M 200
52 Installation of HDPE Pipe - 40 mm dia and sealing of the same for wire/Cable protection. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe as per Tata Power-DDL specification & drawing M 5000
53 Sagging & Stringing of Wolf Conductor including Jumpering & making of connection hooks etc as per Tata Power-DDL specification & drawing M 2000
54 Sagging & Stringing of Dog Conductor(Bare/ Insulated) including Jumpering & making of connection hooks etc as per Tata Power-DDL specification & drawing M 50000
55 Sagging & Stringing of Rabbit (Bare/insulated) Conductor including Jumpering & making of connection hooks etc.as per Tata Power-DDL specification & drawing M 10000
56 Laying ,testing & commissioning of 11kV Armoured XLPE AL Cable/CCD Cable of size 3CX400/ 3X300 sqmm (Single Run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 20000
57 Laying, testing & commissioning of 11kV Armoured XLPE AL Cable/CCD Cable of size 3CX400/ 3X300 sqmm (Double RUN) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 10000
58 Laying testing & commissioning of 11kV Armoured XLPE AL Cable of size 3CX150 sqmm in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 200
59 Laying testing & commissioning of 11kV Armoured XLPE AL Cable 3CX400/ 3CX300 sqmm in trenchless duct as per Tata Power-DDL specification & drawing. Scope of work exclude fixing/laying of HDPE pipe.Also provide ABD to EIC M 100000
60 Stringing of 11kV, XLPE insulated, AL Conductor AB Cable 3CX95+1CX95 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 500
61 Stringing of 11kV, XLPE insulated, AL Conductor AB Cable 3CX150+1CX150 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 100000
62 Stringing of 11kV, XLPE insulated, AL Conductor AB Cable 1CX95+1CX55 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 200
63 Stringing of 11kV, XLPE insulated, AL Conductor AB Cable 1CX150+1CX155 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 10000
64 Installation of Straight Through Jointing Kit for 11kV XLPE insulated, AL conductor AB Cable 1CX95sqmm as per Tata Power-DDL specification & drawing EA 20
65 Installation of Straight Through Jointing Kit for 11kV XLPE insulated, AL conductor AB Cable 1CX150sqmm as per Tata Power-DDL specification & drawing EA 200
66 Installation of Outdoor End Termination Kit of 1CX95 sqmm (Single) for 11kV XLPE insulated AL AB Cable as per Tata Power-DDL specification & drawing EA 50
67 Installation of Outdoor End Termination Kit of 1CX150 sqmm (Single) for 11kV XLPE insulated AL AB Cable as per Tata Power-DDL specification & drawing EA 1000
68 Stringing of 1.1 kV XLPE insulated AL conductor AB Cable of size 4C X 70 + 1C X 75 SQMM + 1 X 16 sqmm as per Tata Power-DDL specification including testing of cable M 500
69 Stringing of 1.1 kV XLPE insulated AL conductor AB Cable of size 3C/4C X 150 + 1C X 155 SQMM + 1 X 16 sqmm as per Tata Power-DDL specification including testing of cable M 300000
70 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 2CX10 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 100000
71 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 2CX25 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 100000
72 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 4CX25 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 200000
73 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 4CX50 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 100000
74 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 4CX95 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 30000
75 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 4CX150 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 50000
76 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 4CX300 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 100000
77 Stringing/Laying of 1.1kV XLPE insulated PVC sheathed AL conductor Cable of size 1CX95 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 5000
78 Stringing/Laying of 1.1kV XLPE insulated PVC sheathed AL conductor Cable of size 1CX185 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 1000
79 Stringing/Laying of 1.1kV XLPE insulated PVC sheathed AL conductor Cable of size 1CX300 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 30000
80 Stringing/Laying of 1.1kV XLPE insulated PVC sheathed AL conductor Cable of size 1CX630 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 60000
81 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 2CX16 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 10000
82 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 2CX25 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 100000
83 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 4CX25 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 5000
84 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 4CX50 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 3000
85 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 4CX95 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 10000
86 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 4CX150 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 3000
87 Laying of LT, XLPE, GI wire Armoured, AL Cable of size 4CX300 sqmm in S/Sth. Trench/Trenchless duct/Tray/GI Pipe/Hume Pipe as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude laying of Hume Pipe, GI Pipe, PVC Pipe and Tray M 50000
88 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX150 sqmm in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
89 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX300 sqmm in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
90 Installation of Straight Through Joint KIT for LT AB Cable 1CX70 sqmm as per Tata Power-DDL specification and drawing EA 20
91 Installation of Straight Through Joint KIT for LT AB Cable 1CX150 sqmm as per Tata Power-DDL specification and drawing EA 20
92 Crimping and Fixing/connecting to terminal of AL Lugs 4 sqmm as per Tata Power-DDL specification and drawing EA 1000
93 Crimping and Fixing/connecting to terminal of AL Lugs 10 sqmm as per Tata Power-DDL specification and drawing EA 1000
94 Crimping and Fixing/connecting to terminal of AL Lugs 25 sqmm as per Tata Power-DDL specification and drawing EA 50000
95 Crimping and Fixing/connecting to terminal of AL Lugs 35 sqmm as per Tata Power-DDL specification and drawing EA 200
96 Crimping and Fixing/connecting to terminal of AL Lugs 50 sqmm as per Tata Power-DDL specification and drawing EA 20000
97 Crimping and Fixing/connecting to terminal of AL Lugs 70 sqmm as per Tata Power-DDL specification and drawing EA 200000
98 Crimping and Fixing/connecting to terminal of AL Lugs 95 sqmm as per Tata Power-DDL specification and drawing EA 50000
99 Crimping and Fixing/connecting to terminal of AL Lugs 150 sqmm as per Tata Power-DDL specification and drawing EA 20000
100 Crimping and Fixing/connecting to terminal of AL Lugs 185 sqmm as per Tata Power-DDL specification and drawing EA 500
101 Crimping and Fixing/connecting to terminal of AL Lugs 300 sqmm as per Tata Power-DDL specification and drawing EA 50000
102 Crimping and Fixing/connecting to terminal of AL Lugs 400 sqmm as per Tata Power-DDL specification and drawing EA 5000
103 Crimping and Fixing/connecting to terminal of AL Lugs 630 sqmm as per Tata Power-DDL specification and drawing EA 20000
104 Glanding armored 1.1 kV XLPE AL Cable - 2CX2.5/16/25 sqmm, including making hole in base plate and dressing of cable as per Tata Power-DDL specification and drawing EA 5000
105 Glanding armored 1.1 kV XLPE AL Cable - 4CX25 sqmm, including making hole in base plate and dressing of cable as per Tata Power-DDL specification and drawing EA 5000
106 Glanding armored 1.1 kV XLPE AL Cable - 4CX50 sqmm, including making hole in base plate and dressing of cable as per Tata Power-DDL specification and drawing EA 1369
107 Glanding armored 1.1 kV XLPE AL Cable - 4CX95 sqmm, including making hole in base plate and dressing of cable as per Tata Power-DDL specification and drawing EA 3000
108 Glanding armored 1.1 kV XLPE AL Cable - 4CX150 sqmm, including making hole in base plate and dressing of cable as per Tata Power-DDL specification and drawing EA 1000
109 Glanding armored 1.1 kV XLPE AL Cable - 4CX300 sqmm, including making hole in base plate and dressing of cable as per Tata Power-DDL specification and drawing EA 1000
110 Glanding armored 1.1 kV XLPE AL Cable - 1CX300 sqmm, including making hole in base plate and dressing of cable, as per TPDDL specification and drawing. EA 2000
111 Glanding armored 1.1 kV XLPE AL Cable - 1CX630 sqmm, including making hole in base plate and dressing of cable , as per TPDDL specification and drawing. EA 2000
112 Providing connection of service cable, 1 phase in LV distribution box / IPC, , as per TPDDL specification and drawing. EA 5000
113 Providing connection of service cable, 3 phase in LV distribution box / IPC, , as per TPDDL specification and drawing. EA 5000
114 Mounting of Cable (below 70 sqmm) at Pole, after passing through suitable size of GI Pipe proper clamping and fixing cleating arrangement along with clamping of terminations as per Tata Power-DDL specification and drawing . Scope of work exclude supply and erection of Cleat set ST 500
115 Mounting of Cable (above 70 and below 150 sqmm) at Pole, after passing through suitable size of GI Pipe proper clamping and fixing cleating arrangement along with clamping of terminations as per Tata Power-DDL specification and drawing Scope of work exclude supply and erection of Cleat set ST 1000
116 Mounting of Cable (above 150 sqmm) at Pole, after passing through suitable size of GI Pipe proper clamping and fixing cleating arrangement along with clamping of terminations as per Tata Power-DDL specification and drawing Scope of work exclude supply and erection of Cleat set ST 5000
117 Supply, Installation/laying of HDPE Pipe - 125 mmdia (PN-6 PE-80) and sealing of the same for wire/Cable protection as per Tata Power-DDL specification and drawing. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 5000
118 Supply, Installation/laying of HDPE Pipe - 140 mmdia (PN-4 PE-80) and sealing of the same for wire/Cable protection as per Tata Power-DDL specification and drawing .Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 1000
119 Supply, Installation/laying of HDPE Pipe - 140 mmdia (PN-4 PE-63) and sealing of the same for wire/Cable protection as per Tata Power-DDL specification and drawing. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 1000
120 Supply, Installation/laying of HDPE Pipe - 160 mmdia (PN-4 PE-80) and sealing of the same for wire/Cable protection. as per Tata Power-DDL specification and drawing. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 1000
121 Supply, Installation/laying of HDPE Pipe - 160 mmdia (PN-4 PE-63) and sealing of the same for wire/Cable protection as per Tata Power-DDL specification and drawing. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 10000
122 Supply, Installation/laying of HDPE Pipe - 200 mmdia (PN-4 PE-80) and sealing of the same for wire/Cable protection as per Tata Power-DDL specification and drawing. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 1000
123 Making Trenchless ducts with 160 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 2000
124 Making Trenchless ducts with 160 mm dia HDPE pipe (single run) casing using HDD machine including supply of pipe as per IS 4984, PN4 Class PE63 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 20000
125 Making Trenchless ducts with 160 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 10000
126 Making Trenchless ducts with 160 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 2000
127 Making Trenchless ducts with 160 mm dia HDPE pipe (double run) casing using HDD machine including supply of pipe as per IS 4984, PN4 Class PE63 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 20000
128 Making Trenchless ducts with 160 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 2000
129 Making Trenchless ducts with 200 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE80(Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
130 Making Trenchless ducts with 200 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE80(Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
131 Making Trenchless ducts with 200 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
132 Making Trenchless ducts with 200 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
133 Making Trenchless ducts with 200 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE63(Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
134 Making Trenchless ducts with 200 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE63(Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
135 Making Trenchless ducts with 200 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE63 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
136 Making Trenchless ducts with 200 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE63 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 500
137 Making Trenchless ducts with 125 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 5000
138 Making Trenchless ducts with 125 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN6 Class PE80 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 20000
139 Making Trenchless ducts with 125 mm dia HDPE pipe (single run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE63 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 1000
140 Making Trenchless ducts with 125 mm dia HDPE pipe (double run) casing using HDD machine including supply of HDPE pipe as per IS 4984, PN4 Class PE63 (Providing parabolic graph icluded in the scope) as per Tata Power-DDL specification and drawing M 1000
141 Making Trenchless ducts with 160 mm dia HDPE pipe (single run) casing Manually including supply of HDPE pipe as per IS 4984, PN4 Class PE80 as per Tata Power-DDL specification and drawing M 5000
142 Making Trenchless ducts with 160 mm dia HDPE pipe (single run) casing manually including supply of pipe as per IS 4984, PN4 Class PE63 as per Tata Power-DDL specification and drawing M 10000
143 Making Trenchless ducts with 160 mm dia HDPE pipe (single run) casing Manually including supply of HDPE pipe as per IS 4984, PN6 Class PE80 as per Tata Power-DDL specification and drawing M 5000
144 Making Trenchless ducts with 160 mm dia HDPE pipe (double run) casing Manually including supply of HDPE pipe as per IS 4984, PN4 Class PE80 as per Tata Power-DDL specification and drawing M 2000
145 Making Trenchless ducts with 160 mm dia HDPE pipe (double run) casing manually including supply of pipe as per IS 4984, PN4 Class PE63 as per Tata Power-DDL specification and drawing M 5000
146 Making Trenchless ducts with 160 mm dia HDPE pipe (double run) casing Manually including supply of HDPE pipe as per IS 4984, PN6 Class PE80 as per Tata Power-DDL specification and drawing M 2000
147 Making Trenchless ducts with 125 mm dia HDPE pipe (single run) casing Manually including supply of HDPE pipe as per IS 4984, PN6 Class PE80 as per Tata Power-DDL specification and drawing M 5000
148 Making Trenchless ducts with 125 mm dia HDPE pipe (double run) casing Manually including supply of HDPE pipe as per IS 4984, PN6 Class PE80 as per Tata Power-DDL specification and drawing M 5000
149 Making Trenchless ducts with 200 mm dia HDPE pipe (single run) casing Manually including supply of HDPE pipe as per IS 4984, PN4 Class PE80 as per Tata Power-DDL specification and drawing M 500
150 Making Trenchless ducts with 200 mm dia HDPE pipe (Double run) casing Manually including supply of HDPE pipe as per IS 4984, PN4 Class PE80 as per Tata Power-DDL specification and drawing M 500
151 Installation of Pre - fabricated Hot dip Galvanized Steel Structure of different sections as per approved drawing and specification of Tata Power-DDL. Scope also includes minor modification/fabrication required as per site condition/ for proper fitting. KG 400000
152 Fabrication and erection of MS Steel Structure including painting (one coat of red oxide & two coats of synthetic/aluminium paint) as per Tata Power-DDL specification / drawing. Scope also includes supply of ISI marked paint. KG 1500000
153 Fabrication & Installation including applying 1 coat of red oxide & 2 coats of synthetic enamel paint(ISI marked), grouting of Jalli/Mesh as per Tata Power-DDL specifications and drawing. Scope of work does not include supply and laying/installation of cement cocrete, brick work, supporting MS Steel Structure and shall be paid as a separate item KG 300000
154 Fixing of GI Nut & Bolts as per Tata Power-DDL specification / drawing. KG 80000
155 Supply, Fabrication & Installation including applying 1 coat of red oxide & 2 coats of synthetic enamel paint(ISI marked), grouting of Jalli/Mesh as per Tata Power-DDL specifications and drawing. Scope of work excluding supply and laying/installation of cement cocrete, brick work, supporting MS Steel Structure and shall be paid as a separate item KG 300000
156 Supply and Installation of Pre - fabricated Hot dip Galvanized Steel Structure of different section as per Tata Power-DDL approved drawing and specification. KG 2000000
157 Supply and Fixing of GI Bolts & Nuts as per Tata Power-DDL specification / drawing. KG 200000
158 Erection of Switch TPN INCOMER (IC) 63 A 415V as per Tata Power-DDL specification / drawing. EA 200
159 Erection of Switch TPN INCOMER (IC) 100 A 415V as per Tata Power-DDL specification / drawing. EA 200
160 Erection of Switch TPN INCOMER (IC) 200 A 415V as per Tata Power-DDL specification / drawing. EA 200
161 Installation of single arm GI pipe bracket for fixing of fitting including bending of Pipe EA 500
162 Installation, Testing and Commissioning of 11kV 3-way Ring Main Unit (O/D) on existing structure as per Tata Power-DDL specification including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 500
163 Installation, Testing and Commissioning of 11kV 3-way Ring Main Unit (I/D) on existing structure as per Tata Power-DDL specification including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 100
164 Installation, Testing and Commissioning of 11kV 4-way O/D Ring Main Unit on existing structure as per Tata Power-DDL specification including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 500
165 Installation, Testing and Commissioning of 11kV 4-way I/D Ring Main Unit on existing structure as per Tata Power-DDL specification including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 100
166 Installation, Testing and Commissioning of 11kV 1-way Ring Main Unit on existing structure as per Tata Power-DDL specification including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 100
167 Trimming of tree branches (per branches) EA 5000
168 Installation of line spacers as per TPDDL specification and drawing. EA 1000
169 Installation of Shackle insulator as per TPDDL specification and drawing. EA 1000
170 Installation of Template for Transformer maintenance Record EA 1000
171 Installation of Bird Cap as per Tata Power-DDL specification / drawing. EA 10000
172 Making of hole at consumer premises for LT Armoured cable support angle EA 2000
173 Grouting of service cable support angle at consumer premises EA 2000
174 Supply and Installation of Tape PVC adhesive 19MMX10M as per Tata Power-DDL specification / drawing. EA 10000
175 Supply, Fabrication and Erection of Aluminum flat 25X1.5 mm and marking cable number, sizes etc for cable tag as per Tata Power-DDL specification / drawing. EA 5000
176 Installation of one lamp point in indoor substation including the supply of 1 lamp holder , 2 board , 1 no. 5 A switch ,8 meter betten and 20 mtr 1cx2.5 sq mm copper pvc insulated wire and other consumables excluding the supply of lamp EA 500
177 Supply, Fabrication and Erection of Feeder identification tag(HT/LT) with marking of Cable/feeder details for over head Cable. As per TPDDL specification & drawing.Marking shall be done with reflective paint. EA 500
178 Supply & Installation of Tie Plastic size 9mmX265mm EA 5000
179 Supply & Installation of Tie Plastic size 4.6mmX286mm EA 2000
180 Installation of Tie Plastic EA 10000
181 Installation of Steel Strap 20mm (Price per Mtr.) as per Tata Power-DDL specification / drawing. M 10000
182 Installation of Buckle for Steel Strap as per Tata Power-DDL specification / drawing. EA 20000
183 Providing and Fixing of Steel Shuttering for excavation of pit for loop in/loop out of Cable M2 400
184 Supply and Fixing of cable Route marker including transportation from site/tent, excavation, refilling, disposing of malba, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing. Scope excludes providing & laying of cement concrete and shall be paid as separate item EA 20000
185 Fixing /installation of Cable Trench Cover as per Tata Power-DDL specification / drawing. EA 2000
186 Making of hole for penetration of Cable from Substation (11 kV/ grid 33 kV or 66 kV) wall and sealing of the cable (Price per hole) as per Tata Power-DDL specification / drawing. EA 500
187 Installation of Fire Extinguisher as per Tata Power-DDL specification / drawing by means of proper hooks clamps etc. as required including providing of grouting material (cement etc.) and painting of hooks/clamps. Scope exclude supply of hook/clamp EA 1000
188 Installation of Fire Bucket as per Tata Power-DDL specification / drawing including supply of sand by means of proper hooks clamps etc. as required (price per bucket). Scope exclude supply of hooks/clamps/MS stand EA 1000
189 Fixing of Rubber Mat as per Tata Power-DDL specification / drawing. EA 500
190 Fixing of First Aid/ Shock treatment Chart as per Tata Power-DDL specification / drawing. EA 500
191 Motorization of RMU (Installation of motor in Existing RMU Schneider / Abb/or any other make including required connection) EA 50
192 Installation of FRTU including GPRS router with proper earthing as per Tata Power-DDL specification / drawing. EA 50
193 Making of plinth foundation for GI octagonal pole up to 9 meter mtr as per Tata Power-DDL specifications and drawing. EA 2000
194 Installation of GI octagonal pole of 10 &11 mtr including foundation bolts and all other required accessories including suitable arm bracket. This excludes making of foundation and S&I of overhead bracket EA 200
195 Making of plinth foundation for GI octagonal pole from 10 meter to 11 mtr as per Tata Power-DDL specifications and drawing. EA 200
196 Excavation of cable trench upto 1075 mm depth & 450 mm width in Ordinary Soil as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 20000
197 Excavation of cable trench upto 1075 mm depth & 450 mm width in Brick Work as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 50000
198 Excavation of cable trench upto 1075 mm depth & 450 mm width in Foot-Path of Tile/Rajasthani Stone/Ordinary Cement as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 10000
199 Excavation of cable trench upto 1075 mm depth & 450 mm width in Ordinary Bitumenous Road as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 10000
200 Excavation of cable trench upto 1075 mm depth & 450 mm width in Dense Carpeted Bitunenous Road up to 200 thick as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI / HDPE Pipe. For each additional cable 50% will be payable against above activity M 15000
201 Excavation of cable trench upto 1075 mm depth & 450 mm width in Dense Carpeted Bitunenous Road 201mm to 300 mm as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 5000
202 Excavation of cable trench upto 1075 mm depth & 450 mm width in Rocky Area as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 5000
203 Excavation of cable trench upto 1075 mm depth & 450 mm width in RCC up to depth of 300 mm road as per Tata Power-DDL drawing and specification for laying of 11kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 2000
204 Excavation of cable trench upto 975 mm depth & 450 mm width in Ordinary Soil as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 20000
205 Excavation of cable trench upto 975 mm depth & 450 mmwidth in Brick work as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 1000
206 Excavation of cable trench upto 975 mm depth & 450 mm width in Foot-Path of Tile/Rajasthani Stone/Ordinary Cement as per Tata Power-DDLdrawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 1000
207 Excavation of cable trench upto 975 mm depth & 450 mmwidth in Ordinary Bitumenous Road as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI / HDPE Pipe. For each additional cable 50% will be payable against above activity M 20000
208 Excavation of cable trench upto 975 mm depth & 450 mm width in Dense Carpeted Bitunenous Road up to 200 mm as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 35000
209 Excavation of cable trench upto 975 mm depth & 450 mm width in Dense Carpeted Bitunenous Road 201mm to 300 mm as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 30000
210 Excavation of cable trench upto 975 mm depth & 450 mm width in Rockey Area as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 1000
211 Excavation of cable trench upto 975 mm depth & 450 mm width in RCC up to depth of 300 mm road as per Tata Power-DDL drawing and specification for laying of 1.1kV one Cable. Scope of work excludes laying of HUME/PVC pipe/GI/ HDPE Pipe. For each additional cable 50% will be payable against above activity M 1000
212 Digging (150 cm x 60 cm) test pit in Soft Soil for locating lillo and identifying faulty cable. Scope also includes back filling, ramming, leveling and removal of malba after jointing. (If it is used in trenchless, only unsucessful test pit will be payable) EA 500
213 Digging (150 cm x 60 cm) test pit in Bricks/Foothpath for locating lillo and identifying faulty cable. Scope also includes back filling, ramming, leveling and removal of malba after jointing. (If it is used in trenchless, only unsucessful test pit will be payable) EA 500
214 Digging (150 cm x 60 cm) test pit in Carpet Road for locating lillo and identifying faulty cable. Scope also includes back filling, ramming, leveling and removal of malba after jointing. (If it is used in trenchless, only unsucessful test pit will be payable) EA 500
215 Digging (150 cm x 60 cm) test pit in CC/Dence Carpeted bituminous for locating lillo and identifying faulty cable.Scope also includes back filling, ramming, leveling and removal of malba after jointing. (If it is used in trenchless, only unsucessful test pit will be payable) EA 1000
216 Breaking of Asphalt/Concrete for Pole / Stay/ Earthing Pit including supply of blasting material if any required M2 10000
217 Cutting/dismantling of RCC/PCC/Carpet road up to 450mm depth for excavation of pit for Installation of Pole/Stay set etc. (Depending upon site conditions) EA 1000
218 Cutting/dismantling of RCC/PCC/Carpet road above 450 mm depth for excavation of pit for Installation of Pole/Stay set etc. (Depending upon site conditions) EA 500
219 Demolishing cement concrete manually/ by mechanical means including disposal of material as per direction of Engineer-in-charge M3 5000
220 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material as per direction of Engineer-in-charge. M3 5000
221 Removal & disposal of Debris of other agency (Not applicable where removal and desposal is mentioned in the item rate) M3 5000
222 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqmm on plan including disposal of excavated earth for all kinds of soil M2 200
223 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth as per direction of EIC for all kinds of soil. M3 1000
224 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed by EIC for all kinds of soil M3 500
225 Filling available excavated earth (excluding rock) trenches, plinth, sides of foundations etc. layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming watering M3 5000
226 Supplying and filling in plinth with Jamuna sand under floors including, watering, ramming, consolidating and dressing complete. M3 500
227 Supplying & filling of earth or ordinary soil excavated and brought from outside without any contents of inorganic materials boulders, etc. M3 1000
228 Supply and laying of sand in substation cable trench (where it is not included in the scope) M3 1000
229 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size). M3 1000
230 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (Zone - III) : 4 graded stone aggregate 20 mm nominal size) M3 5000
231 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size). M3 1000
232 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (Zone - III) : 6 graded stone aggregate 20 mm nominal size). M3 1000
233 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (Zone - III) : 8 graded stone aggregate 40 mm nominal size). M3 1000
234 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size) M3 500
235 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work upto plinth level b) 1:2:4 (1cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size. M3 500
236 Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. M2 500
237 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) M3 500
238 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) M3 500
239 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) M3 200
240 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) M3 1000
241 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all levels. Thermo-Mechanically TrEAted bars. KG 4000
242 15 mm cement plaster on the rough side of single or half brick wall of mix for all heights: 1:4 (1 cement: 4 fine sand) M2 2000
243 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) M2 1000
244 15 mm cement plaster on the rough side of single or half brick wall of mix for all heights: 1:4 (1 cement: 4 coarse sand) M2 2000
245 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) M2 1000
246 12 mm cement plaster of mix for all heights: 1:4 (1 cement: 4 fine sand) M2 2000
247 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) M2 1000
248 12 mm cement plaster of mix for all heights: 1:4 (1 cement: 4 coarse sand) M2 1000
249 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) M2 2000
250 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement- 12 mm cement plaster M2 1000
251 6 mm cement plaster of mix for all heights: 1:3 (1 cement: 3 fine sand) M2 1000
252 Neat cement punning as per Tata Power-DDL specifcation. Scope includes supply of cement M2 2000
253 Transportation of various items from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area - Trolla with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like, Rail Pole, PCC Pole, HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately. EA 500
254 Transportation of various items from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area - Full body Truck with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately EA 1000
255 Transportation of various items from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area - Tempo 709 with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately EA 5000
256 Transportation of various items from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area - Tempo 407 with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately EA 5000
257 Transportation of various items from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area - Three wheeler/Vikram with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately EA 5000
258 Loading, transportation and Unloading of PSCC Pole up to 9m long from Tata Power-DDL store/site to other site or vice versa (above 6 km ) - price per Pole. EA 1000
259 Loading, transportation and Unloading of PSCC Pole above 9m long from Tata Power-DDL store/site to other siteor vice versa (above 6 km) - price per Pole. EA 1000
260 Loading, transportation and Unloading of Rail Pole from Tata Power-DDL store/site to other site or vice versa (up to 6 km) - price per Pole. EA 20
261 Loading, transportation and Unloading of Rail Pole from Tata Power-DDL store/site to other site or vice versa (above 6 km) - price per Pole. EA 20
262 Dismantling of 11 Mtr. PCC Pole(Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 3km /BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 2000
263 Dismantling of 11 Mtr. PCC Pole(Broken Pole) after digging the pit and taking out the pole, refilling the pit with loose earth and ramming. Scope also includes removal & disposal of malba along with dismantled part of pole at proper location as per instruction of EIC EA 10000
264 Dismantling of 9 Mtr. PCC Pole(Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 3km /BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 2000
265 Dismantling of 9 Mtr. PCC Pole(Broken Pole) after digging the pit and taking out the pole, refilling the pit with loose earth and ramming. Scope also includes removal & disposal of malba along with dismantled part of pole at proper location as per instruction of EIC EA 10000
266 Dismantling of steel tublar Pole after digging the pit and taking out the pole as per Tata Power-DDL practice, transportation and staking of pole at proper place in safe position within 3 km/BA site store and refilling pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 200
267 Dismantling of M.S Rail Pole after digging the pit and taking out the pole as per Tata Power-DDL practice, transportation and staking of pole at proper place in safe position within 3 km/BA site store and refilling pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 40
268 Dismantling of existing 11/0.4kV, 990/1000kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
269 Dismantling of existing 11/0.4kV, 630kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 500
270 Dismantling of existing 11/0.4kV, 500kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 150
271 Dismantling of existing 11/0.4kV, 400kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 300
272 Dismantling of existing 11/0.4kV, 315kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 300
273 Dismantling of existing 11/0.4kV, 250kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 800
274 Dismantling of existing 11/0.4kV, 160kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 800
275 Dismantling of existing 11/0.4kV, 100kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 800
276 Dismantling of existing 11/0.4kV, 63kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 500
277 Dismantling of existing 11/0.4kV, 25kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
278 Dismantling of existing 11/0.4kV, 16kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
279 Dismantling of existing 6.3/0.24kV, Three 16 kVA single Phase Distribution Transformer(DT Bank) including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
280 Dismantling of existing 6.3/0.24kV, Three 10 kVA single Phase Distribution Transformer(DT Bank) including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
281 Dismantling of existing 6.3/0.24kV, Three 25 kVA single Phase Distribution Transformer(DT Bank) including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
282 Dismantling of existing 6.3/0.24kV, 25kVA Single Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
283 Dismantling of existing 6.3/0.24kV, 16kVA Single Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
284 Dismantling of existing 6.3/0.24kV, 10kVA Single Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 500
285 Dismantling of existing 11/0.4kV, 630kVA thee phase Package sub station including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 10
286 Dismantling of existing 11/0.4kV, 400 kVA thee phase Package sub station including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 10
287 Dismantling of 11kV, CT/PT Unit along with HT metering system and HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
288 Dismantling of Metering Cubicle including removal HT/LT lead, earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
289 Dismantling of LT Distribution Box suitable for 400/500 kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 100
290 Dismantling of LT Distribution Box suitable for 315kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 100
291 Dismantling of LT Distribution Box suitable for 250kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
292 Dismantling of LT Distribution Box suitable for 160kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
293 Dismantling of LT Distribution Box suitable for 100kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
294 Dismantling of LT Distribution Box suitable for 63kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
295 Dismantling of LT Distribution Box suitable for 25kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
296 Dismantling of LT Distribution Box suitable for 16kVA 3-Phase Distribution Transformer including their safe removal. Scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
297 Dismantling of ACB-400A including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
298 Dismantling of ACB-800A including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 50
299 Dismantling of ACB-1250A including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 50
300 Dismantling of ACB-2000A and above including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 20
301 Dismantling of Feeder Pillar Type -A/B including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
302 Dismantling of Service Pillar including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
303 Dismantling of LT Distribution Box with accessories including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
304 Dismantling of Moulded Bus Bar Box including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 200
305 Dismantling of 11 kV Single Panel from Kiosk/Indoor/ Outdoor including their safe removal and dragging out. The scope of work also includes the removal of all the Electric/Earth connections but exclude loading/unloading. EA 100
306 Dismantling of 11 kV RMU (Smart/Non-smart) from Kiosk/Indoor/ Outdoor including their safe removal and dragging out. The scope of work also includes removal of all the Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store . EA 400
307 Dismantling of ACSR Wolf conductor, recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 5000
308 Dismantling of ACSR DOG conductor from over head line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 500000
309 Dismantling of ACSR Rabbit conductor from over head line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 200000
310 Dismantling of ACSR Racoon conductor from over head line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 100000
311 Dismantling of ACSR Weasel/Squirell and other smaller size conductor from over head line , recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 100000
312 Dismantling of HT AB Cable 3CX95+1CX95 sqmm from over head line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 100000
313 Dismantling of HT AB Cable 3CX150+1CX150 sqmm from over head recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store M 100000
314 Dismantling of HT AB Cable 1CX95+1CX55 sqmm from over head line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 50000
315 Dismantling of HT AB Cable 1CX150+1CX155 sqmm from over head recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store M 50000
316 Dismantling of LT AB Cable 3C X 70 + 1C X 75 SQMM + 1 X 16sqmm from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store M 50000
317 Dismantling of LT AB Cable 3C/4C X 150 + 1C X 55 SQMM + 1 X 16sqmm from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store M 100000
318 Dismantling of existing LT/HTPVC/ XLPE/Armoured Cable of size up to 35sqmm including making of coil, rebound on drum, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 500000
319 Dismantling of existing LT/HTPVC/ XLPE/Armoured Cable of size above 35 to 70sqmm including making of coil, rebound on drum, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 100000
320 Dismantling of existing LT/HTPVC/ XLPE/Armoured Cable of size above 70 to 150sqmm including making of coil, rebound on drum, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 20000
321 Dismantling of existing LT/HTPVC/ XLPE/Armoured Cable of size above 150sqmm including making of coil, rebound on drum, loading, transportation, unloading and staking at a proper place in safe position/BA site store M 20000
322 Dismantling of 11 kV GOAB Switch including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
323 Dismantling of 11 kV Three Phase DD Fuse Unit (price per set) including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
324 Dismantling of 11 kV Single Phase DD Fuse Unit including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
325 Dismantling of LA including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 5000
326 Dismantling of Anti Climbing Device including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 5000
327 Dismantling of Danger Board including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 5000
328 Dismantling of HT AL Bus bar mounted on 11kV insulator with re-openable insulation cover including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 50
329 Dismantling of 11kV Pin Insulator with Pin including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 5000
330 Dismantling of 11kV Disc Insulator with Hardware including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
331 Dismantling of Suspension Clamp including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 2000
332 Dismantling of Dead End Clamp including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
333 Dismantling of Eye Hook including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 3000
334 Dismantling of Insulated Piercing Connectors including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 5000
335 Dismantling of Clamps and Connectors- Mini Wedge connector/C Wedge connector/PG Clamp/T Clamp including loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 1000
336 Dismantling of the G.I.Wire 7/8 SWG as per standard practice of Tata Power-DDL including recoiling loading, transportation, unloading and staking at a proper place in safe position/BA site store M 20000
337 Dismantling of the G.I.Wire 7/10 SWG as per standard practice of Tata Power-DDL including recoiling loading, transportation, unloading and staking at a proper place in safe position/BA site store M 40000
338 Dismantling of the G.I.Wire 4 SWG as per standard practice of Tata Power-DDL including recoiling loading, transportation, unloading and staking at a proper place in safe position/BA site store M 50000
339 Dismantling of the G.I.Wire 6 SWG as per standard practice of Tata Power-DDL including recoiling loading, transportation, unloading and staking at a proper place in safe position/BA site store M 10000
340 Dismantling of the G.I.Wire 8 SWG as per standard practice of Tata Power-DDL including recoiling loading, transportation, unloading and staking at a proper place in safe position/BA site store M 50000
341 Dismantling of the G.I.Wire 16 SWG as per standard practice of Tata Power-DDL including recoiling loading, transportation, unloading and staking at a proper place in safe position/BA site store M 100
342 Dismantling of Steel Structure and Nuts and Bolt including loading, transportation, unloading and staking of dismanled material at a proper place in safe position/BA site store KG 500000
343 Dismantling of Cable Route Marker after digging the pit and taking out, transportation and stacking at a proper place in safe position BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 200
344 Dismantling/Removal of all hardware fittings & Insulator etc. from LT Single Pole including loading, transportation, unloading and staking of dismanled material at a proper place in safe position/BA site store (price per Pole) EA 1000
345 Dismantling/Removal of all hardware fittings & Insulator etc. from HT Single Pole including loading, transportation, unloading and staking of dismanled material at a proper place in safe position/BA site store (price per Pole) EA 1000
346 Dismantling/Removal of all hardware fittings & Insulator etc. from Double Pole Structure including loading, transportation, unloading and staking of dismanled material at a proper place in safe position/BA site store (price per DP) EA 500
347 Dismantling/Removal of all hardware fittings & Insulator etc. from Triple Pole Structure including loading, transportation, unloading and staking of dismanled material at a proper place in safe position/BA site store (price per TP Structure) EA 100
348 Dismantling/Removal of all hardware fittings & Insulator etc. from Four Pole Structure including loading, transportation, unloading and staking of dismanled material at a proper place in safe position/BA site store EA 50
349 Dismantling of ICTPN/MCCB based Switches of all sizes in the I/D S/STN. Includingtheir safe removal and stacking at tent site. EA 200
350 Dismantling of existing Street Light fixture and loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 2000
351 Dismantling of Fencing structure and loading, transportation, unloading and staking at a proper place in safe position/BA site store M2 5000
352 Dismantling of motor from Existing RMU Schneider / Abb/any other make including removal of all connections EA 50
353 Dismantling of FRTU including GPRS router and earthing as per Tata Power-DDL specification / drawing. EA 200
354 Dismantling of UPS & GPRS router for the FPI sites EA 100
355 Installation, testing and commissioning of 12 meter high mast light along with installation of flood light and all other activities associated or incidental thereto as per tpddl specification & drawing EA 10
356 Installation, testing and commissioning of 16 meter high mast light along with installation of flood light and all other activities associated or incidental thereto as per tpddl specification & drawing EA 10
357 Installation, testing and commissioning of 20 meter high mast light along with installation of flood light and all other activities associated or incidental thereto as per tpddl specification & drawing EA 10
358 Installation, testing and commissioning of 990/1000 kVA packaged substation as per tpddl specification & drawing EA 20
359 Installation, testing and commissioning of 630 kVA packaged substation as per tpddl specification & drawing EA 20
360 Installation, testing and commissioning of 400 kVA packaged substation as per tpddl specification & drawing EA 20
361 Transportation of PSS from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area. Scope of work also include loading and unloading with crane. EA 80
362 Installation, Testing (Insulation resistance , Voltage/Turn Ratio , Magnetizing Current and series lamp Test ) and Commissioning of 6.3/0.24 kV, 50 kVA 1-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 200
363 Installation of HDPE Pipe - 32mmdia and sealing of the same for wire/Cable protection as per tpddl specification. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 5000
364 Laying ,testing & commissioning of 11kV Armoured XLPE AL Cable of size 1CX630 sqmm in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 2000
365 Dismantling of existing 6.3/0.24kV, 50kVA Single Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/BA site store EA 50
366 Dismantling of existing fencing & then installation of same fencing which includes- dismantling of civil work, de-grouting of fencing legs from tow wall, de-welding of jali/ mesh etc.,Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials, civil work including grouting of fencing legs, welding of jail/ mesh, cutting , painting with primer/ paint. RM 500
367 Installation testing and commissioning of ACDB for 630 KVA DT for single incoming on existing structure as per tpddl specification & drawing. EA 10
368 Installation testing and commissioning of ACDB for 630 KVA DT for double incoming on existing structure as per tpddl specification & drawing. EA 50
369 Installation testing and commissioning of ACDB for 990 KVA DT for single incoming on existing structureas per tpddl specification & drawing. EA 10
370 Installation testing and commissioning of AC DB for 990 KVA DT for double incoming on existing structure as per tpddl specification & drawing. EA 50
371 Laying/stringing of LT 1.1 kV XLPE insulated PVC sheathed AL conductor GI wire Armoured Cable of size 2CX16 sqmm as per Tata Power-DDL specification & drawing m 300000
372 Stringing/Laying of 1.1kV XLPE insulated PVC sheathed AL conductor Cable of size 2CX25 sqmm as per Tata Power-DDL specification & drawing m 1000
373 Connections of Street Light Fitting with 2C*25 Sqmm cable as per tpddl specification & drawing. EA 1000
374 Laying ,testing & commissioning of 11kV Co-extruded cable of size 3CX400 sqmm along with trenchless without HDPE pipe for Double run. (This item includes the Trenchless activity with HDD Machine along with supply of bentonite powder) as per tpddl specification & drawing M 200000
375 Providing & Laying C.C in brick ballast in 1:6:12 (1 Cement : 6 Coarse Sand : 12 Brick aggregate) mix M3 5000
376 Supplying and applying pre tested and approved water based concrete curing compound to concrete/ masonry surface, all as per manufacturer’s specification and direction of Engineer-in-charge. Non pigmented wet curing compound M2 2000
377 Supplying, laying & spreading machine crushed 20 mm good quality blue colour stone aggregates including compacting the same. M3 1000
378 Installation/Erection of 11 Mtr. spun Pole -1000kG including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete, Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) EA 20
379 Installation/Erection of 11 Mtr. spun Pole-750kG including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete, Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) EA 20
380 Installation/Erection of 11 Mtr. spun Pole-500 kG including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete, Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) EA 100
381 Installation/Erection of 11 Mtr. spun Pole-250 kG including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete, Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) EA 20
382 Cage Welding for single phase & three phase transformers (each) after installation, testing and commissioning and shall be as per requirement/recommendation of project incharge EA 100
383 Installation, Testing and Commissioning of 11kV 5-way I/D Ring Main Unit on existing structure as per Tata Power-DDL specification & drawing including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 50
384 Installation, Testing and Commissioning of 11kV 5-way O/D Ring Main Unit on existing structure as per Tata Power-DDL specification & drawing including grouting, loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection and construction of foundation EA 50
385 Installation, Testing and commissioning of 11kV Pole Mounted Breaker Unit on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection. EA 100
386 Installation, Testing and commissioning of 11kV trip saver Unit on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection. EA 50
387 Installation, Testing and commissioning of 11kV intellirupter unit on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection. EA 50
388 Installation, Testing and commissioning of 11kV auto reclosure Unit on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection. EA 100
389 Installation, Testing and commissioning of 11kV sectionaliser Unit on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site/tent. Scope of work excludes earthing, jumpering/connection. EA 100
390 Installation, testing and commissioning of 400 kVA compact substation (CSS) as per Tata Power-DDL specification & drawing EA 6
391 Installation, testing and commissioning of 250 kVA unitised substation (USS) as per Tata Power-DDL specification & drawing EA 6
392 Installation, testing and commissioning of 400 kVA unitised substation (USS) as per Tata Power-DDL specification & drawing EA 6
393 Installation, testing and commissioning of 630 kVA unitised substation (USS) as per Tata Power-DDL specification & drawing EA 10
394 Route surveying of the cable route with the help of Geograhic Position Rradar (GPR)/any better geo scanning device for cables, OFC, sewer, water or any other services to ensure safety of these services/utilities while cable laying.The map after GPR survey to be submitted to Tata Power-DDL for review and approval. it is imperative that any damage to the utilities shall be on BA's account. BA should liason with Civic agencies ,IGL, DJB, Telecom , Gail and arrange to coduct the GPR for the Cable and other infrastructure and to identify the safe route for cable laying . M 800000
395 Supply, testing and installation of earthing with earth enhancement material (of approved make) through 40mm dia 3 Mtr long Heavy Class GI Pipe, earth clamp, earth pit chamber, cover and connection arrangement for connection to equipment. This includes backfilling and site restoration. The work shall be done as per TPDDL specification and drawings/design where in the resistance is not achieved through normal earthing. Prior approval is required from Engineer in charge. Scope excludes supply of GI pipe. EA 100
396 Providing services for shoring with planks for excavation depth more than 1.8M in joint pits/trench. SQM 200
397 Laying ,testing & commissioning of 11kV Armoured XLPE AL Cable of size 1CX630 sqmm in excavated trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC.(from grid substation to RMU) M 5000
398 Painting on MS Steel Structure/surface (one coat of red oxide & two coats of synthetic/aluminium paint) as per Tata Power-DDL specification / drawing. Scope also includes supply of ISI marked paint as per Tata Power-DDL specification & approved make. M2 2000
399 Installation of SMC/Nylon cleat - single hole type (as per Tata Power-DDL specification & drawing), along with GI hardware (25 mm X 6 mm) clamps for fixing cable. EA 5000
400 Installation of SMC/Nylon cleat - four hole type (as per Tata Power-DDL specification & drawing), along with GI hardware (25 mm X 6 mm) clamps for fixing cable. EA 5000
401 Supply, installation of SMC/Nylon cleat - single hole type (as per Tata Power-DDL specification & drawing), along with GI hardware (25 mm X 6 mm) clamps for fixing cable. EA 2000
402 Supply, installation of SMC/Nylon cleat - four hole type (as per Tata Power-DDL specification & drawing), along with GI hardware (25 mm X 6 mm) clamps for fixing cable. EA 2000
403 Installation, Testing and Commissioning of 11kV metering cubicle with RMU on existing structure as per Tata Power-DDL specification including grouting, loading, unloading, shifting/transportation from site/tent to place of installation. This item does not include earthing, jumpering/connection and construction of the foundation.if required, to be done shall be paid separately. EA 20
404 Sign writing on Pole/pipe/cable/Sub Station and other equipment (not installed by BA) at suitable height as per requirement and direction of engineer in charge with synthetic enamel paint of berger/asian or approved make including preparation of back ground with two or more coats of yellow paint with primer to ensure uniform surface in following sizes. All tools, tackles and other equipments for carrying out the work are to be arranged by the BA. (This item shall be paid only for already erected pole/old Pole). For new pole & ITC of the pole is in bidder scope then this item shall not be payable. EA 500
405 Rectification/Straightening of tilted pole in all respect including New Gen Hydra/ Crane as the case may be. EA 200
406 String of 1.1 KV XLPE insulated AL conductor AB Cable of size 2Cx25 Sqmm + 1Cx25sqmm as per TPDDL specification including testing of cable M 2000
407 SITC of BOBIN Insulator as per tpddl specification & drawing EA 200
408 Supply & Installation of copper wire 3cx4 sqmm including all assecessries used for termination also. M 200
409 Supply & Installation of thimble 4 mm copper EA 200
410 Dismantling of 11kV Auto Reclosure Unit from existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. EA 50
411 Dismantling of 11kV Sectionalizer Unit from existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. EA 50
412 Dismantling of 11kV Pole mounted breaker from existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. EA 10
413 Dismantling of 11kV trip saver Unit on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. EA 20
414 ITC-Animal guard on DT HT bushing as per tpddl specification and drawing EA 2000
415 ITC-SMC/Nylon cleat on LV cable of DT as per TPDDL specification and drawing EA 500
416 Fixing of Bird spike with suitable cap as per TPDDL specification and drawing EA 10000
417 Installation of RFID tag as per TPDDL specification and drawing for 11 kv cable laying EA 20
418 ITC of monkey scare as per TPDDL specification and drawing EA 200
419 SITC of Safety awareness board that shall be installed on fencing of all 11 KV substations & other relevant locations as per TPDDL drawing. EA 2000
420 Fixing of insulation sleeve/Polypro/Polyolefin as per TPDDL specification and drawing M 5000
421 Mounting of CCD Cable at Pole, after passing through suitable size of GI Pipe with proper clamping and fixing of cleating arrangement along with clamping of terminations as per Tata Power-DDL specification and drawing. Scope of work exclude supply and erection of Cleat set. Scope of work includes painting on (CCD) i.e. co-extruded 11 KV cable with fire retardant paint as per TPDDL specification and drawing, up to 2 meter from termination end, as per instruction of engineer in charge. EA 500
422 Supplying & Installation, testing and commissioning of 12 meter high mast light with 6 luminaries of 200W LED (1 complete set) along with installation of flood light and all other activities associated or incidental thereto as per tpddl specification & drawing ST 10
423 Supplying &Installation, testing and commissioning of 16 meter high mast light with 9 luminaries of 200W LED (1 complete set) along with installation of flood light and all other activities associated or incidental thereto as per tpddl specification & drawing ST 10
424 Supplying & Installation, testing and commissioning of 20 meter high mast light with 12 luminaries of 200W LED along with installation of flood light and all other activities associated or incidental thereto as per tpddl specification & drawing ST 10
425 ITC-Cantilever based GO mechanism EA 100
426 Making Trenchless ducts with Coextruded cable (single run) casing Manually including laying of Cable M 5000
427 Installation of Outdoor Type Distribution Box with MCCB, 63A on existing structure as per Tata Power-DDL specification and drawing. EA 100
428 Installation of Outdoor Type Distribution Box with MCCB, 100A on existing structure as per Tata Power-DDL specification and drawing. EA 100
429 Installation of Outdoor Type Distribution Box with MCCB, 125A on existing structure as per Tata Power-DDL specification and drawing. EA 100
430 Installation of Outdoor Type Distribution Box with MCCB, 250A on existing structure as per Tata Power-DDL specification and drawing. EA 100
431 Installation of Outdoor Type Distribution Box with MCCB, 400A on existing structure as per Tata Power-DDL specification and drawing. EA 100
432 Installation of Outdoor Type Distribution Box with MCCB, 500A on existing structure as per Tata Power-DDL specification and drawing. EA 100
433 Installation of 100/125/150 mm dia GI Pipe for Cable protection as per Tata Power-DDL specification & drawing M 5000
434 Laying of GI Pipe -100/125/150/ 200mm dia and sealing of the same for Laying LT/HT Cables. Scope aIso includes providing and laying all required consumable etc. for sealing of Pipe as per Tata Power-DDL specification & drawing (Excavation is excluded) M 5000
435 Installation of HDPE Pipe - 25 mm dia and sealing of the same for wire/Cable protection. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe as per Tata Power-DDL specification & drawing M 40000
436 Laying testing & commissioning of 11kV Armoured XLPE AL Cable/CCD Cable 3CX400/ 3X300 sqmm in already laid GI Pipe/Hume Pipe/ HDPE/ PVC Pipe (Any Size) as per Tata Power-DDL specification & drawing including testing of cable. Scope of work exclude fixing of HDPE Pipe, Hume Pipe, GI Pipe, PVC Pipe M 30000
437 Stringing/Laying of 1.1kV XLPE insulated PVC sheathed AL conductor Cable of size 1CX2.5/4/16/25 sqmm as per Tata Power-DDL specification & drawing including testing of cable M 2000
438 Crimping and Fixing/connecting to terminal of AL Lugs 16 sqmm as per Tata Power-DDL specification and drawing EA 1000
439 Only Testing of 11kV any Switchgear panels(RMU/Autoreclosure/Pole mounting Breaker etc.) on existing structure as per Tata Power-DDL specification Scope of work excludes earthing, jumpering/connection and construction of foundation EA 100
440 Supply & Fixing of Epoxy resin hardner "M-seal- Pidilite Mark" as per Tata Power-DDL specification / drawing, including consumable(300gm / hole to be use) Price per one hole EA 1000
441 Fixing of cable Route marker including transportation from site/tent, excavation, refilling, disposing of malba, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing. Scope excludes providing & laying of cement concrete and shall be paid as separate item EA 1000
442 Supply and Fixing /installation of Cable Trench Cover as per Tata Power-DDL specification / drawing. EA 500
443 Assistance for installation of FRTU as per Tata Power-DDL specification / drawing. EA 20
444 Transportation of various items from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area - E-RICKSHAW with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately EA 1000
445 Loading of HT panel,Transformer, LT board, Cable drum with crane or tripode Per truck/tempo (Price per HT panel,Transformer, LT board, Cable drum) EA 2000
446 Unloading of HT panel,Transformer, LT board, Cable drum with crane or tripode Per truck/tempo (Price per HT panel,Transformer, LT board, Cable drum ) EA 2000
447 Dismantling of upto 150 mm Dia GI Pipe including loading, transportation, unloading and staking at a proper place in safe position/BA site store M 5000
448 Transportation of USS from Tata Power-DDL store/site to other site or vice versa in Tata Power-DDL operational area. Scope of work also include loading and unloading with crane. EA 30
449 Laying ,testing & commissioning of 11kV Armoured XLPE AL Cable of size 1CX630 sqmm in existing s/s trench/already laid HDPE/Hume/RCC/GI pipe. M 5000
450 Connections of Street Light Fitting with 2C*2.5 Sqmm cable as per tpddl specification & drawing. EA 500
451 Laying ,testing & commissioning of 11kV Co-extruded cable of size 3CX400 sqmm along with trenchless without HDPE pipe for Triple run. (This item includes the Trenchless activity with HDD Machine along with supply of bentonite powder) as per tpddl specification & drawing M 40000
452 Assistance of DT smart meter Installation. The work shall be done under supervision of Protection team. EA 200
453 Dismantling of 11kV Intellirupter Unit on existing structure as per Tata Power-DDL specification & drawing including loading, unloading, shifting/transportation from site/tent. EA 50
454 Removal of dense vegetation/grass etc as per the direction of Engineer incharge M2 1000
455 Installation/Erection of 11 Mtr. Bundled Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 400
456 Installation/Erection of 9 Mtr. Bundled Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 200
457 Interlocking Paver Block Providing & laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction ,of approved size,design & shape ,laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand,filling the joints with line sand. all complete as per direction of Engineer in charge M2 2000
458 Installation of Flying stay including supply material EA 100
459 Supply and installation of Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and paint KG 20000
460 Supply and installation of Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and paint KG 200000
461 De-watering of pole pit with the help of pump/submersible motor. (This service shall be given after HOD - DP Approval) EA 1000
462 SITC of 16 mm Al wire for earthing M 1000
463 SITC of 16 mm Al Lug for earthing EA 1000
464 SITC of Jubliee clamp EA 1000
465 Installation of flat type eye hook EA 100
466 Dismantling of 11 Mtr. Spun Pole(Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 3km /BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 50
467 Dismantling of 11 Mtr. Spun Pole(Broken Pole) after digging the pit and taking out the pole, refilling the pit with loose earth and ramming. Scope also include crushing of broken Pole and removal & disposal of malba at proper location as per instruction of EIC EA 50
468 Dismantling of 9 Mtr. Spun Pole(Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 3km /BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 50
469 Dismantling of 9 Mtr. Spun Pole(Broken Pole) after digging the pit and taking out the pole, refilling the pit with loose earth and ramming. Scope also include crushing of broken Pole and removal & disposal of malba at proper location as per instruction of EIC EA 50
470 Dismantling of 11 Mtr. bundled Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 3km /BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 100
471 Dismantling of 11 Mtr. bundled Pole (Broken Pole) after digging the pit and taking out the pole, refilling the pit with loose earth and ramming. Scope also include crushing of broken Pole and removal & disposal of malba at proper location as per instruction of EIC EA 200
472 Dismantling of 9 Mtr. bundled Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 3km /BA site store and refilling the pit with loose earth and ramming including removal and dispsal of malba at proper location as per instruction of EIC. EA 100
473 Dismantling of 9 Mtr. bundled Pole (Broken Pole) after digging the pit and taking out the pole, refilling the pit with loose earth and ramming. Scope also include crushing of broken Pole and removal & disposal of malba at proper location as per instruction of EIC EA 100
474 Making , covering and heat shrinking of cable end by suitable size breakout with earth stip and socketing for cable sizes of 1.1 kV 4X25, 4X50, 4X95, 4X150 and 4X300 sq. mm . EA 100
475 SITC of 70 Watts LED Lamp fittings complete with associated material & Clamps including Bending of pipe (wherever required etc.) as per Tata Power-DDL specification / drawing & approved makes & model. Type test reports to be submitted for GTP approval. EA 200
476 SITC of 150 Watts LED Lamp fittings complete with with associated material & Clamps including Bending of pipe (wherever required etc.) as per Tata Power-DDL specification / drawing & approved makes & model. Type test reports to be submitted for GTP approval. EA 100
477 SITC of 250 Watts LED Lamp fittings complete with with associated material & Clamps including Bending of pipe (wherever required etc.) as per Tata Power-DDL specification / drawing & approved makes & model. Type test reports to be submitted for GTP approval. EA 50
478 SITC of 400 Watts LED Lamp fittings complete with with associated material & Clamps including Bending of pipe (wherever required etc.) as per Tata Power-DDL specification / drawing & approved makes & model. Type test reports to be submitted for GTP approval. EA 50
479 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX25/50/95 sqmm in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
480 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX25/50/95 sqmm (Double run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
481 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX25/50/95 sqmm (Triple run)) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
482 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX25/50/95 sqmm (Quadruple run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
483 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX150 sqmm(Double run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
484 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX150 sqmm( Triple run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
485 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX150 sqmm(Quadruple run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 50000
486 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX300 sqmm(Double run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
487 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX300 sqmm( Triple run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 100000
488 Laying (underground) of 1.1kV Armoured XLPE AL Cable of size 4CX300 sqmm(Quadruple run) in existing trench with supply & laying of 9 bricks horizontaly with sand & back filling, ramming and levelling of earth as per Tata Power-DDL specification and drawing including testing of cable. Scope also include removal and disposal of loose malba above road/ground level as per instruction of EIC M 50000
489 Supply & Painting on co-extruded 11 KV cable with fire retardant paint as per TPDDL specification and drawing, on exposed parts as per instruction of engineer in charge (per meter length ) M 2000
490 Installation of FRP Fencing(upto height -2050 mm) of substations/RMU as per Tata Power-DDL specification and drawing excluding civil work RM 2000
491 Supply of FRP fencing Pallas/Door as per Tata Power-DDL specification & drawing Sq M 1000
492 Installation of Hybrid Fencing(MS posts & FRP Pallas/Doors) including applying 1 coat of red oxide & 2 coats of synthetic enamel paint(ISI marked) for MS structure, grouting of FRP pallas as per Tata Power-DDL specifications and drawing. Scope of work excluding supply and laying/installation of cement cocrete, brick work, supporting MS Steel Structure and shall be paid as a separate item RM 2000
493 Painting of existing Mesh/jalli Structure both sides with two coats of synthetic paint after surface claening \as per Tata Power-DDL specification / drawing. Scope also includes supply of ISI marked & Approved make of paint. M2 10000
494 Providing heavy labour for shifting of Switchgear Pannel etc. for installation, dragging with chain block, tripod, required accessories, safety PPE etc. (price per Transformer/ Switchgear panel) for distance upto 10 metre EA 200
495 Providing heavy labour for shifting of Switchgear Pannel etc. for installation, dragging with chain block, tripod, required accessories, safety PPE etc. (price per Transformer/ Switchgear panel) for distance more than 10 metre EA 200
496 Supply, Installation/laying of HDPE Pipe -75 mmdia (PN-6 PE-80) and sealing of the same for wire/Cable protection as per Tata Power-DDL specification and drawing. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 2000
497 Installation of 70 Watts street light Fixture/HPMV/HPSV or equivalent alternative LED Lamp fittings complete with Clamps as per Tata Power-DDL specification / drawing. Scope also includes installation of Single arm GI Bracket including bending of pipe EA 2000
498 Installation of 150 Watts street light Fixture/HPMV/HPSV or equivalent alternative LED Lamp fittings complete with Clamps including as per Tata Power-DDL specification drawing. Scope also includes installation of Single arm GI Bracket including bending of pipe EA 3000
499 Installation of 250 Watts street light Fixture/HPMV/HPSV or equivalent alternative LED Lamp fittings complete with Clamps as per Tata Power-DDL specification / drawing. Scope also includes installation of Single arm GI Bracket including bending of pipe EA 2000
500 Installation of 400 Watts street light Fixture/HPMV/HPSV or equivalent alternative LED Lamp fittings complete with Clampsas per Tata Power-DDL specification / drawing. Scope also includes installation of Single arm GI Bracket including bending of pipe EA 1000
501 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 990/1000kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification and drawing including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side. EA 200
502 Installation of GI octagonal pole of up to 5 mtr including foundation bolts and all other required accessories including suitable arm bracket. This excludes making of foundation and S&I of overhead bracket EA 1000
503 Installation of GI octagonal pole of length (upto 9 mtr & more than 5 mtr) including foundation bolts and all other required accessories including suitable arm bracket. This excludes making of foundation and S&I of overhead bracket EA 1000
504 Supply & Installation of MCB-6-amp Double pole [ ISI Marked] EA 100
505 Supply & Laying of 1.1KV 3Cx1.5 sq.mm unarmoured cable M 500
506 SITC of 25 mm Dia Flexible pipe for 3x1.5 sqmm wiring in pipe M 500
507 Excavation Up to 1.5m Lift Including Dewatering M3 200
508 Supply & Installation of GI octagonal pole of up to 5 mtr including foundation bolts and all other required accessories including suitable arm bracket. This excludes making of foundation and S&I of overhead bracket EA 1000
509 Supply & Installation of HDPE Pipe -40 mm dia and sealing of the same for wire/Cable protection as per tpddl specification. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 2000
510 Laying of PVC 50 mm dia and sealing of the same for Laying LT Cables. Scope aIso includes providing and laying all required consumables etc. for collar fixing and sealing of Pipe as per Tata Power-DDL specification & drawing (Excavation is excluded) M 1000
511 Supply & installation of PVC special type of sleeve 3M per pole for 4C*25sqmm cable in pole junction box as per tata power-ddl specification & drawing M 50
512 Supply & Installation of HDPE Pipe -50 mm dia and sealing of the same for wire/Cable protection as per tpddl specification. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. M 2000
513 Installation of 40/50/75 mm dia GI Pipe for earth wire/Cable protection as per Tata Power-DDL specification & drawing M 1000
514 Laying testing & commissioning of 11kV Armoured XLPE AL Cable/CCD cable in S/Sth. Trench/Tray as per Tata Power-DDL specification & drawing including testing of cable. Scope of work excludes Painting on CCD cable with fire retardant paint as per TPDDL specification, M 10000
515 Making of new foundation for 3-way/4-way (Non-smart) RMU including excavation for foundation and supply of raw material i.e. sand,badarpur, cement, bricks and removal of malba if any as per siterequirement including labour required for the same (PCC 1:4:8/ as persite requirement). Scope of work includes MS steel structure for foundation as per Tata Power-DDL specification / drawing. EA 500
516 Making of new foundation for 3-way(Smart)/4-way(Smart)/ 5 way RMU ( Non-Smart) RMU including excavation for foundation and supply of raw material i.e. sand,badarpur, cement, bricks and removal of malba if any as per siterequirement including labour required for the same (PCC 1:4:8/ as persite requirement). Scope of work includes MS steel structure for foundation as per Tata Power-DDL specification / drawing. EA 500
517 Making of new foundation for 1-way RMU (Non-smart) & RN2C including excavation for foundation and supply of raw material i.e. sand,badarpur, cement, bricks and removal of malba if any as per siterequirement including labour required for the same (PCC 1:4:8/ as per site requirement). Scope of work includes MS steel structure for foundation as per Tata Power-DDL specification / drawing. EA 200
518 Making foundation for USS as per Tata Power-DDL drawing & specification including supply of all materials EA 20
519 SITC of fireball EA 50
520 Installation/Erection of 9 Mtr. PSCC Pole (Manually ) including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 1000
521 Installation ,testing of single phase DT manually EA 100
522 Dismantling of Single phase DT manually EA 100
523 Installation of Pre-Cast RMU Plinth as per Tata power DDL specification & drawing.Scope includes loading,unloading & transportation. ST 300
524 Installation of block(500 mm height) of Pre cast DT Plinth as per Tata power DDL specification & drawing.Scope includes loading,unloading & transportation. EA 1000
525 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m) having 50 no rounds per 6 metre length, upto 3m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) /Spring core (2.5mm thick) wire of high tensile strength of 165 KG/ sq.mm with tape (0.52 mm thick) and weight 43.478gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) M 2000
526 Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 KG per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately) :-Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire M 10000
527 Installation/Erection of 09 Mtr. PSCC Square Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 500
528 Installation/Erection of 11 Mtr. PSCC Sqare Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, refilling, flooding with water, ramming/compacting of foundation as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brick betting, providing & laying of cement concrete. EA 100
529 SITC of Hume pipe of 600mm dia and 2 m length for installation of pole including transportation ,installation,loading and unloading, EA 300
530 Installation/Erection of 9M Two Piece Spun Pole including loading and unloading, transportation from site/tent upto 6 Kms., excavation, fixing of base plate, backfilling, flooding with water, ramming/compacting of foundation, setting up & removal of mounting arrangement after installation of upper piece including fixing nuts and bolts complete as per Tata Power-DDL specifications and drawing including Pole Indexing and Painting of Pole (In Black & Yellow Strips/Zebra) and removal & disposal of malba as per instruction of EIC. The scope of work excludes Brickbat filling, providing & laying of cement concrete. EA 100
531 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 1600 kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification and drawing including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side. EA 30
532 Installation of Top Hamper Clamp as per TPDDL specification & drawings EA 500
533 Installation of Post Insulator as per TPDDL specification & drawings EA 1000
534 Installation of pre fabricated angle (Slotted angle) EA 1000
535 Installation of FRP Cross Arm as per TPDDL specification & drawings EA 1000
536 Installation, Testing (Insulation Resistance , Voltage/Turn Ratio, , Magnetizing Current and Series Lamp Test) and Commissioning of 6.3/0.24 kV, 10kVA Single Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side. EA 5
537 Installation, Testing (Insulation Resistance , Voltage/Turn Ratio, , Magnetizing Current and Series Lamp Test) and Commissioning of 6.3/0.24 kV,, 16kVA Single Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side. EA 20
538 Installation, Testing (Insulation Resistance , Voltage/Turn Ratio, , Magnetizing Current and Series Lamp Test) and Commissioning of 6.3/0.24 kV, 25kVA Single Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side. EA 75
539 Installation, Testing (Insulation Resistance , Voltage/Turn Ratio, , Magnetizing Current and Series Lamp Test) and Commissioning of 6.3/0.24 kV three single phase transformers(DT Bank) of 10 KVA , on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 2
540 Installation, Testing (Insulation Resistance , Voltage/Turn Ratio, , Magnetizing Current and Series Lamp Test) and Commissioning of 6.3/0.24 kV three single phase transformers(DT Bank) of 16 KVA , on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 2
541 Installation, Testing (Insulation Resistance , Voltage/Turn Ratio, , Magnetizing Current and Series Lamp Test) and Commissioning of 6.3/0.24 kV three single phase transformers(DT Bank) of 25 KVA , on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 2
542 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp test ) and Commissioning of 11/0.4kV, 16kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side. EA 50
543 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 25kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 100
544 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 63kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 200
545 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 100kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 300
546 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 160kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 300
547 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 250kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 300
548 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 315kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 200
549 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 400kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 400
550 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 500kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 400
551 Installation, Testing (Insulation resistance , Voltage/Turn Ratio, Magnetic Balance , Magnetizing Current and series lamp Test ) and Commissioning of 11/0.4kV, 630kVA 3-Phase Distribution Transformer on existing structure as per Tata Power-DDL specification including loading, unloading, shifting/transportation from site /tent. Scope of work excludes earthing, jumpering/connection at HT and LT side EA 300
552 Laying of PVC Pipe -160/150/ 200 mm dia and sealing of the same for Laying LT/HT Cables. Scope aIso includes providing and laying all required consumables etc. for collar fixing and sealing of Pipe as per Tata Power-DDL specification & drawing (Excavation is excluded) M 250
553 Laying ,testing & commissioning of 11kV Co-extruded cable of size 3CX400 sqmm along with trenchless without HDPE pipe for Single run. (This item includes the Trenchless activity with HDD Machine along with supply of bentonite powder) as per tpddl specification & drawing M 200000
554 Indoor Termination of 11 kV Armoured XLPE, AL Cable 3CX300 sqmm including consumable as per Tata Power-DDL specification & drawing EA 100
555 Outdoor Termination of 11 kV Armoured XLPE, AL Cable 3CX300 sqmm including consumable as per Tata Power-DDL specification & drawing EA 100
556 Indoor Termination of 11 kV Armoured XLPE, AL Cable 3CX400 sqmm including consumable as per Tata Power-DDL specification & drawing EA 1000
557 Outdoor Termination of 11 kV Armoured XLPE, AL Cable 3CX400 sqmm including consumable as per Tata Power-DDL specification & drawing EA 1000
558 Installation of Straight Through Joint KIT of 11kV XLPE Armoured Cable 3Cx400 sqmm including consumable as per Tata Power-DDL specification & drawing EA 3000
559 Installation of Straight Through Joint KIT of 11kV XLPE Armoured Cable 3Cx300 sqmm including consumable as per Tata Power-DDL specification & drawing EA 20
560 Installation of Straight Through Joint KIT of 11kV XLPE Armoured Cable 3Cx150 sqmm including consumable as per Tata Power-DDL specification & drawing EA 20
561 Installation of Straight Through Joint Kit for 1.1 kV XLPE AL Cable 4CX25 sqmm as per Tata Power-DDL specification and drawing EA 100
562 Installation of Straight Through Joint Kit for 1.1 kV XLPE AL Cable 4CX50 sqmm as per Tata Power-DDL specification and drawing EA 20
563 Installation of Straight Through Joint Kit for 1.1 kV XLPE AL Cable 4CX95 sqmm as per Tata Power-DDL specification and drawing EA 20
564 Installation of Straight Through Joint Kit for 1.1 kV XLPE AL Cable 4CX150 sqmm as per Tata Power-DDL specification and drawing EA 20
565 Installation of Straight Through Joint Kit for 1.1 kV XLPE AL Cable 4CX300 sqmm as per Tata Power-DDL specification and drawing EA 500
566 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Hard Rock (Blasting prohibited) M3 129.6
567 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary or hard rock M3 21.6
568 Disposal of all debris/rubbish/malba/surplus excavated earth/similar unserviceable, dismantled or waste materials arising out of demolition and construction activities, by mechanical means, including loading, transporting, unloading to authorized Construction and Demolition (C&D) waste recycling plant or approved municipal dumping ground as per the directions of TPDDL Engineer-in-charge, for all leads including all lifts involved. Bidder solely shall be responsible for identifying such area and bear all costs involved, TPDDL shall not be liable for the same. Bidder shall clear the site thoroughly of such unwanted materials and rubbish etc. left out of his work and dress the site to the satisfaction of the TPDDL Engineer-in-Charge in all respects before the final handing over. Nothing additional shall be paid on account of disposal of waste material to construction and demolition (C&D) waste recycling plant. M3 129.6
569 Supply & Installation of GI octagonal 8 mtr Pole including foundation bolts and all other required accessories including suitable arm bracket. This excludes making of foundation and S&I of overhead bracket EA 1000
570 Supply & Installation of GI octagonal 9 mtr Pole including foundation bolts and all other required accessories including suitable arm bracket. This excludes making of foundation and S&I of overhead bracket EA 1000
571 Installation of Outdoor Type Distribution Box with MCCB, 160A on existing structure as per Tata Power-DDL specification and drawing. EA 100
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_TPDDL-ENGG-ENQ-200001967-26-27.pdf
Tender Document • 2.27 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure 1.pdf
Tender Document • 0.74 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_ENG-LV-3037_Technical Specification of High Mast Lighting with LED Flood Lights (002).pdf
Tender Document • 0.21 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_PEC-GEN-26-GI Octagonal Poles with Annexure 1.pdf
Tender Document • 25.99 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_TPDDL-PED-5013-01_Product Engineering Drawing of Safety Awareness Board 1.pdf
Tender Document • 0.26 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_TPDDL-PED-5013-01_Product Engineering Drawing of Safety Awareness Board.pdf
Tender Document • 0.26 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_TPDDL-SID-1001-01_Standard Installation Drawing of Electrical Equipments for 11kV Outdoor.pdf
Tender Document • 0.99 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_TPDDL-SID-1003-03_Standard Installation Drawing For Service Line For Residential And Comm.pdf
Tender Document • 1.70 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_TPDDL-SID-1011-01_Standard Installation Drawing of Jumper Connections for 11kV Networks. .pdf
Tender Document • 1.53 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_TPDDL-SID-1014_Common RMU Foundations (Outdoor Installations) 1.pdf
Tender Document • 2.14 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_TPDDL-SID-1031_Standard Installation Drawing Stay and Stud for 9 & 11M Pole.pdf
Tender Document • 1.23 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_TPDDL-SID-1033_Standard Installation Drawing of Electrical Equipment for 11 KV Indoor Sub.pdf
Tender Document • 0.79 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_TPDDL-SID-1035_Standard Installation Drawing of 11kV Cable in Excavated Trench 1.pdf
Tender Document • 1.06 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_TPDDL-SID-1036-01_Standard Installation Drawing of RCC Cable Route & Joint Marker for 11k.pdf
Tender Document • 0.62 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_TPDDL-SID-1038_Standard Installation Drawing of Autoreclosure on 11M Single Pole & Double.pdf
Tender Document • 1.28 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_TPDDL-SID-1043_Standard Installation Drawing of RCC Cable Route & Joint Marker for 440V C.pdf
Tender Document • 0.72 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_ENG-EHV-1019_Technical Specification of MS & GI Structural Steel for Electrical Works.pdf
Tender Document • 0.56 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_ENG-GEN-4007_Standard Technical Particular for Earth Enhancement Compound.pdf
Tender Document • 2.00 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_ENG-GEN-4008-02_Standard Technical Particular of Cable Cleat (Two-Bolt Type).pdf
Tender Document • 0.46 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_ENG-GEN-4023-01_Standard Technical Particular of HDPE Pipes with Annexure.pdf
Tender Document • 0.55 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_ENG-GEN-4024-01_Standard Technical Particular of Galvanized Iron(GI) Pipes.pdf
Tender Document • 0.31 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_ENG-GEN-4055_Technical Specification of Nut, Bolt & Washer.pdf
Tender Document • 0.38 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_Annexure II - Technical Specifications_ENG-LV-3034_Technical Specification of Street Light Lamps and Luminaires (1).pdf
Tender Document • 0.49 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_CSM.pdf
Tender Document • 0.28 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_GCC-Composite.pdf
Tender Document • 3.03 MB
S0056-01-07-2026 10-44-59 AM-Tender Documents 1_SSI Questionnaire - FY 27.pdf
Tender Document • 0.57 MB
Response to Pre BID Queries_20260716174316706_TPD-S-202-C-002_02 GA Drawing For Plate Barricades (3).pdf
Corrigendum • 0.89 MB
Response to Pre BID Queries_20260716174316706_TPD-S-202-C-017_01 Pipe Type DT Plinth With RCC NP3 Hume Pipe.pdf
Corrigendum • 0.64 MB
Response to Pre BID Queries_20260716174316706_2302976a-8f63-4e52-abc3-9a183924c510.JPG
Corrigendum • 0.05 MB
Response to Pre BID Queries_20260716174316706_Foundation details of USS at Zone 417.pdf
Corrigendum • 1.45 MB
Response to Pre BID Queries_20260716174316706_Job Description - Quality Engineer.pdf
Corrigendum • 0.38 MB
Response to Pre BID Queries_20260716174316706_List of approved makes.pdf
Corrigendum • 0.21 MB
Response to Pre BID Queries_20260716174316706_Response to Pre BID Queries.pdf
Corrigendum • 0.25 MB
Response to Pre BID Queries_20260716174316706_Revised Annexure 1.pdf
Corrigendum • 0.73 MB
Response to Pre BID Queries_20260716174316706_Revised Annexure 1.xlsx
Corrigendum • 0.08 MB
Notification of Qualified Bidders_20261015105845540.pdf
Corrigendum • 0.63 MB
Notification of Qualified Bidders_20261015105845540.pdf
Corrigendum • 0.63 MB
Response to Pre BID Queries_20260716174316706.zip
Corrigendum • 4.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .