Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 3 199 SHIV NAGAR RUI KI MANDI SHAHGANJ AGRA 282010 SHIV NAGAR RUI KI MANDI SHAHGANJ AGRA UTTAR PRADESH 282010 UDYAM UP 01 0010537 | AGRA | UTTAR PRADESH | 282010 | Admitted-Finance |
Tender Value
₹89,124
EMD Value
₹1,782
Closing Date
3 May 2024, 1:30 pmClosed
Executive Engineer (Elect.)
BSNL, Electrical Division, Ist Floor, NATFAM Bldg., ALTTC, Ghaziabad
Repairing of AC units at T.E Bldg. Jasrana, Kathpori, Barnahal and Karhal, OA Mainpuri.
2024_BSNL_803929_1
04/EEE/BSNL/ED/GZB/2024-25
Open Tender
Miscellaneous Works
Item Rate
60 days
Mainpuri
Please refer Tender documents.
5 documents required · 5 mandatory
₹177
Account Officer Cash, B.S.N.L, Ghaziabad
₹1,782
14 May 2024
15 Apr 2024
4 May 2024
15 Apr 2024
3 May 2024
15 Apr 2024
Sub-Head-1 (T.E. Jasrana & Kathpori under SDCA Jasrana) Repairing of 1.5TR Split AC unit in various T.E. Bldgs under SDCA Jasrana, Mainpuri i/c replacing of following faulty component, leak testing, Gas charging, serciving, connection etc as reqd (a) Running Capacitor (45MFD)
b) Starting Capacitor (100-120 MFD)
c) Starting Relay
d) Thermostate
f) Repairing / replacenment of Indoor & outdoor PCV for Hitachi make /koolaire make non- Invertor type Split AC Unit etc
g) Repairing of faulty codensor motor of outdoor units i/c rewinding , refixing charges etc as required
h) 20 Amp DP MCB ( C- Type) in existing Panel
i) Servicing and Charging of referegerant gas R-22 in existing 1.50 TR split type AC unit / Window AC unit i/c supplying refrigerent R-22, Leakage rectification in indoor unit & Outdoor unit with piping system, vaccumization and also pressure testing with nitrogen etc complete with connections, testing and commisioning etc as required. (Jasrana-02 Nos & Kathpori-02Nos)
I.T.C. of existing 1.50TR split A/C unit i/c brazing /welding of refrigeration pipe between indoor & outdoor unit and making good the damages , leak test etc complete as reqd.
Supply & Fixing of copper refrigerant pipe lines i.e suction and discharge copper pipe length for split A/C unit of i/c foam insulation etc. complete as required.
Supplying and drawing 3 core 2.5 Sqmm multi core copper conductor PVC insulated FR Power cable for electrical connection etc. as reqd.
Supply & fixing of 19 mm dia heavy duty flexible thread Pipe i/c accessories from unit to suitable distance for drain etc complete as required
Supply & fixing of 25 mm dia heavy duty CPVC pipe i/c accessories from unit to suitable distance for drain etc. complete as required
Providing Front grill of WAC unit with filters i/c Supplying transportation , fixing charges etc as required
Supplying & fixing 2 way steel enclouser with 20 Amp DP MCB in T.E. Bldg Jasrana & Kathapori ,OA Mainpuri i/c connection, testing etc complete as required
Sub-Head-2 (T.E Barnahal & Karhal under SDCA Karhal) Repairing of 1.5TR Split AC unit in various T.E. Bldgs under SDCA Karhal, Mainpuri i/c replacing of following faulty component, leak testing, Gas charging, serciving, connection etc as reqd (a) Running Capacitor (45MFD)
b) Starting Capacitor (100-120 MFD)
c) Starting Relay
d) Thermostate
f) Repairing / replacenment of Indoor & outdoor PCV for Hitachi make /koolaire make non- Invertor type Split AC Unit etc
g) Repairing of faulty codensor motor of outdoor units i/c rewinding , refixing charges etc as required
h) Servicing and Charging of referegerant gas R-22 in existing 1.50 TR split type AC unit / Window AC unit i/c supplying refrigerent R-22, Leakage rectification in indoor unit & Outdoor unit with piping system, vaccumization and also pressure testing with nitrogen etc complete with connections, testing and commisioning etc as required. (T.E. Barnahal (SAC-02 Nos) & Karhal (SAC-03 Nos +WAC-01 No)
i) Replacement of faulty blower motor of wac units by new one i/c refixing charger, testing etc as required ( Karhal-01)
Supplying and drawing 3 core 2.5 Sqmm multi core copper conductor PVC insulated FR Power cable for electrical connection etc. as reqd.
Supply & fixing of 19 mm dia heavy duty flexible thread Pipe i/c accessories from unit to suitable distance for drain etc complete as required
Supplying & fixing 2 way steel enclouser with 20 Amp DP MCB in T.E. Bldg Jasrana & Kathapori ,OA Mainpuri i/c connection, testing etc complete as required
SITC of 4 KVA AVR copper wound analog type having voltage range 140 to 280 V for 1.5 TR split A/C unit complete with high/low voltage cutoff and time delay relay & Push button for instant start etc. as required (with torriodal transformer) (M/s Blue Bird & SS make) (Invoice shall be submitted)
M/s Mohit Engineers
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .