Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bid | |
| 2 | L2₹21.9 L+₹1.7 L (8.20%)Rejected-AOC | L2 | Rejected-AOC Being higher than L1 Bid | |
| 3 | L3₹22.7 L+₹2.5 L (12.1%)Rejected-AOC C O M KHARKARANG LUMJINGSUK BLOCK A MADANRTING SHILLONG 793021 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793021 | L3 | Rejected-AOC Being higher than L1 Bid | |
| 4 | L4₹23.1 L+₹2.9 L (14.6%)Rejected-AOC | L4 | Rejected-AOC Being higher than L1 Bid | |
| 5 | L5₹23.4 L+₹3.2 L (15.8%)Rejected-AOC | L5 | Rejected-AOC Being higher than L1 Bid |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
31 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SILCHAR
GE SILCHAR,PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
CERTAIN REPAIRS TO PATHS AND CLEANING AND MAINTENANCE OF WATER TANKS AT CIJW SCHOOL AT VAIRENGTE AND LAILAPUR UNDER GE SILCHAR
2022_MES_568435_1
8756/E8
Open Tender
Civil Works
Item Rate
180 days
VAIRENGTE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹40,000
Yes
31 Jan 2023
10 Dec 2022
7 Jan 2023
10 Dec 2022
31 Dec 2022
26 Dec 2022
17 Dec 2022 - 21 Dec 2022
Amount
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for and removal of debris complete all as specified and as directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed
Taking down old unserviceable road studs of any type from any location and position and disposing off including making good the disturbed areas, etc. complete all as specified and as directed
Taking up or down 15mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed
Taking up or down 20mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed
Taking up or down 25mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed
S&F steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed of the following bores:
15mm bore
20mm bore
25mm bore
Fixing only steel water tubing, medium grade, galvanised with screwed and socketed joints, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches complete all as specified and as directed for the following bores: Note: Serviceable tubings obtained from dismantling hereinbefore will be reused under this item
15mm bore
20mm bore
25mm bore
S&F in repairs gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, and earthwork in any type of soil or breaking/cutting into road/interlocking tiles/cement concrete, etc. and making good the disturbed surfaces complete all as specified and as directed of the following sizes:
25mm dia
Supplying, hoisting, fixing and connecting up rotational moulded polythylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including dismantling of U/S PVC water tank complete all as specified and as directed of the following capacities:
500litres
1000litres
2000litres
M&L for cleaning of internal surfaces of PVC overhead tanks, including staging (if required), at any position / location, by scrubing the surfaces with the help of coir brush, jute cloth and flushing out all the accumulated mud / silt inside the tank, then applying two coats of lime wash on all internal surfaces like wall, ceiling, floor, etc. and writing tank number, capacity of tank, date of cleaning with white synthetic enamel paint over a black synthetic enemal paint base (of suitable dimensions) with size of letter 4" height complete all as specified and as directed of the following capacities:
250litres
500litres
1000litres
S&F in repairs 15mm dia ball valves PTMT, weighing minimum 142gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
S&F in repairs 20mm dia ball PTMT valves, weighing minimum 210gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
S&F in repairs 25mm dia ball PTMT valves, weighing minimum 455gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
S&F PVC lid suitable for PVC/HDPE storage water tanks, with suitable locking arrangements, of approved colour, duly hinged to existing water tanks located in any position including taking off old eroded tank covers and disposing off complete all as specified and as directed of the following capacities of water tank:
500litres capacity tanks
1000litres capacity tanks
2000litres capacity tanks
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregates as in foundations, filling and mass concrete, bed to drains, etc. complete all as specified and as directed
M&L for 75mm thick plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregates as in sub-bases, path, pavements, etc. finished even and smooth without using extra cement complete all as specified and as directed
M&L for 100mm thick plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregates as in sub-bases, path, pavements, etc. finished even and smooth without using extra cement complete all as specified and as directed
M&L for plain cement concrete 1:2:4 (type B-1) using 20mm graded stone aggregate as in copings and simillar works complete all as specified and as directed
M&L for 40mm thick plain cement concrete 1:2:4 (type B-1) using 20mm graded stone aggregate as in sub-bases, etc. complete all as specified and as directed
M&L for screed bed 15mm thick, in cement mortar (1:6) in bedding layers roughened for receiving floor finish complete all as specified and as directed
M&L rendering 15mm thick in cement mortar (1:4) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, roof, etc. finished even and fair without using extra cement complete all as specified and as directed
M&L rendering 15mm thick in cement mortar (1:4) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, roof, etc. finished even and smooth without using extra cement complete all as specified and as directed
M&L preparation of newly plastered / unplastered surfaces and applying three coats of white wash on walls, etc. complete all as specified and as directed
M&L preparation of newly plastered / unplastered surfaces and applying two coats of colour wash (of approved tint) over a coat of white wash on walls, etc. complete all as specified and as directed
M&L for writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30cm high in approved tint at any locations / positions complete all as specified and as directed
S&F in position solar road stud, of approved design, made of aluminium alloy shell, LED based, of size 125x125x25mm (shank 65mm), 100% water and weather proof design, conforming to IP-67, with high effciency mono-crystalline solar panel 2.4V/0.3W, 1No. Ni-Mh or Ni-cd rechargeable battery (1.2V/1600MA), six super bright LED with 10000 to 18000mcd, continuous working time 3 to 4days after battery fully charged, working temperature 10-75oC complete all as specified and as directed Make: Dark Eye model No. DA-113 or equlvalent model of ABS Engineering, TATA BP, 3M
M&L for fine dry river sand bedding under floors, pavings, etc. then punning down to its consolidated thickness complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
M&L for laying pre-polished, machine pressed, pre-cast in M-40 design mix concrete, 80mm thick, rubber moulded, double glossy, coloured, designer, interlocking paver tiles made of of approved design, shape and size with the crushing strength not less than 250kg/sqcm conforming to IS 15658-2006, laid and and pointed in grey cement mixed with pigment to match colour of tiles complete all as specified and as directed
M&L for vitrified tiles, of size 300x300mm, coloured, 10mm thick, joint free, edge cut, of superior quality, anti-skid, heavy duty on floors, etc. laid, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles complete all as specified and as directed
M&L reflective rubber moulded chequered cement concrete tiles 300x300x25mm thick, laid, set, jointed in neat cement slurry in floors, pavements, etc. and pointed in white cement mixed with pigment to match the colour of tiles complete all as specified and as directed
MS AFTAB LASKAR
Bhuiya Construction
MAGADH TRADING
M/S MOLOY KUMAR DEY
M/S Goutam Chakraborty
M/S TAPAN KUMAR RAY
M/S SUBHAM ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .