Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.2 LAccepted-AOC 70 SUBHASH ROAD HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | 1 | Accepted-AOC Acceptance of tender | |
| 2 | 2₹38.0 L+₹1.1 L (3.09%)Rejected-Finance | 2 | Rejected-Finance Not L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected for opening of cover 2 due to not enlisted in requisite category |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Mar 2025, 6:00 pmClosed
CWE LUCKNOW
REPAIRS / MAINT OF INTERNAL/EXTERNAL ELECTRIFICATION SYSTEM, B/R WORKS AND OTHER CONNECTED WORK SUCH AS FIGHTING EQPT WATER SUPPLY PIPE LINE SUBMERSIBLE PUMP AT WATER SUPPLY INSTALLATION AT PRABUDH VIHAR (PCDA) DEVIKHERA UNDER GE EM LUCKNOW
REPAIRS / MAINT OF INTERNAL/EXTERNAL ELECTRIFICATION SYSTEM, B/R WORKS AND OTHER CONNECTED WORK SUCH AS FIGHTING EQPT WATER SUPPLY PIPE LINE SUBMERSIBLE PUMP AT WATER SUPPLY INSTALLATION AT PRABUDH VIHAR (PCDA) DEVIKHERA UNDER GE EM LUCKNOW
2025_MES_698814_1
CWE/LKO/EM/T-161 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE EM LUCKNOW
₹80,000
Yes
5 Jun 2025
21 Feb 2025
2 Apr 2025
21 Feb 2025
26 Mar 2025
7 Mar 2025
21 Feb 2025 - 7 Mar 2025
Amount
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quions, arches, pillars etc but excluding ashlar facings, dressed stone work and pre cast concrete articles complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving n. exc 15 cm thickness (below or above ground level).
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for.
M&L for Brick work with Fly ash brick designation 100 Kg / Sqcm, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, using bricks of size 230 mm x 110 mm x 70 mm confirming to IS 12894, complete all as specified and as directed by Engineer-in-Charge.
M&L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone agrregate) as in sub base for floor etc all as specified and directed.
M&L for 40 mm thick PCC 1:2:4, type B-1 (using 20 mm graded stone agg) finished even and smooth with using extra cement all as specified and as directed.
M&L for mild steel TMT reinforcement bars of grade FE-500, 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. or securing with clips complete all as specified and directed by Engineer-in-Charge
M&L for mild steel TMT reinforcement bars of grade FE-500, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. or securing with clips complete all as specified and directed by Engineer-in-Charge
M&L for cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in coping and the like, weathering, slightly rounded or chamfered angles including necessary form work complete.
Supply only integral water proofing compound powder ISI marked
Taking up or down 15 mm bore steel tubing and connections, from walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge.
Taking up or down 20 mm bore steel tubing and connections, from walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge.
Taking up or down 25 mm bore steel tubing and connections, from walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge.
Refixing old steel tubing and connections in new or old position on walls, ceiling or floors etc of size 15 mm bore after cleaning including provn of new fittings all as directed by Engineer-in-Charge (using old steel tubing retrived from taking down above).
Refixing old steel tubing and connections in new or old position on walls, ceiling or floors etc of size 20 mm bore after cleaning including provn of new fittings all as directed by Engineer-in-Charge (using old steel tubing retrived from taking down above).
Refixing old steel tubing and connections in new or old position on walls, ceiling or floors etc of size 25 mm bore after cleaning including provn of new fittings all as directed by Engineer-in-Charge (using old steel tubing retrived from taking down above).
S&F 15 mm bore tubes, 'medium grade', galvanised, with all fitting; (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors, complete all as specified.
S&F 20 mm bore tubes, 'medium grade', galvanised, with all fitting; (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors, complete all as specified.
S&F 25 mm bore tubes, 'medium grade', galvanised, with all fitting; (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors, complete all as specified.
M&L for Cleaning of HDPE service water tank of capacity upto 500 litre, and the connected circulating pipes at any position by removing sludge, mud, moss, moulds, efflorescent salts, oil spots etc or any other foreign material from the bottom, cover and internal surfaces by scraping using wire brush, draining out the water from the tank and washing internally with water & bleaching powder (0.10 Kg of bleaching powder will be mix in 1 litre water) and again draining out the water from the tank and writing the date of cleaning with white synthetic enamel paint on black background with synthetic enamel paint complete all as directed by Engineer-in-charge.
M&L for Cleaning of HDPE service water tank of capacity upto 1000 litre, and the connected circulating pipes at any position by removing sludge, mud, moss, moulds, efflorescent salts, oil spots etc or any other foreign material from the bottom, cover and internal surfaces by scraping using wire brush, draining out the water from the tank and washing internally with water & bleaching powder (0.10 Kg of bleaching powder will be mix in 1 litre water) and again draining out the water from the tank and writing the date of cleaning with white synthetic enamel paint on black background with synthetic enamel paint complete all as directed by Engineer-in-charge.
Dismantling water tank capacity 500 ltr and taken as credit
Supply and fix 500 litres capacity double layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc complete
Dismantling water tank capacity 1000 ltr and taken as credit
Supply and fix 1000 litres capacity double layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc complete
S&F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball , suitable for 25 mm bore pipe, screwed for iron pipe and fixed complete all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and as directed by the Engineer-in-Charge
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 Sqm but n exc 4.00 Sqm each complete all as specified and as directed by the Engineer-in-Charge.
Taking down shutters of any description n exc 1 sq.m each complete all as specified.
Taking down shutters of any description exc 1 sq.m and n exc 2 sq.m each complete all as specified.
S&F Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, complete all as shown in drawing of relevant item in MES, schedule Part-II , 2020 as specified and as directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as shown in drawing of relevant item in MES, schedule Part-II , 2020 as specified and as directed by Engineer-in-Charge.
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified.
M&L 30mm thick 2nd class hard wood Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.23(b) complete all as specified.
M&L for Repairing of existing aluminium door single / double leaf (area of each leaf exc 1 Sqm but n.exc 2.0 Sqm) by taking down old door, tightening of joint, tightening of top & bottom patch, replacement of cleat, screw, oiling and greasing of floor springs, & refixing in same opening for smooth functioning complete all as specified. Note:- Floor door springs where renewed shall be measured and paid separately under appropriate item of BOQ.
S&F 250 mm aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolts of extruded section or cast aluminium alloy and fixed
S&F 100 mm size butt hinges medium weight (ISI Marked), rolled mild steel complete.
S&F 75 mm size butt hinges medium weight (ISI Marked), rolled mild steel complete.
S&F in repairs stainless steel auto closing hinges for cub board shutters all as specifed
S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed, 200 mm length of bolt complete all as specified.
S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed, 100 mm length of bolt complete all as specified.
S&F 150 mm size Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge
S&F 100 mm size Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in steel window clips and wooden beading in wooden joinery complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in steel window clips and wooden beading in wooden joinery complete all as specified and directed.
S & F in repair for 150 mm floor door stopper of aluminium alloy body and tonge,anodised with hard drawn steel spring
Hacking out old broken glass, any thickness, size, quality, or description, from frame nexc 1.5 Sqm each pane
S&F for 3.0 mm thick sheet glass ordinary quality and glazing with oil putty nexc 0.5 Sqm each pane
S&F for 3.0 mm thick figured glass ordinary quality and glazing with oil putty n.exc 0.5 Sqm each pane
S&f for 4.8 mm thick sheet glass odinary qulity and glazing with neosprene beading n.exc 0.5 Sqm in each pane
M&L for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F in repairs Aluminium body (extruded section ) body Door closer hydraulically regulated, designation No. 2 , universal type, suitable for door shutters 701 to 850 mm in width and of weight between 36 to 60 Kg and fixed, complete all as specified and directed.
S&F in repair for 100 mm mild steel mortice lock vertical type with 4 brass lever and duplicate key complete all as specified and directed.
S&F in repair 25 mm Stainless steel curtain rod with stainless steel bracket fancy type as approved by GE, as in curtain rods including taking down the old curtains rods complete all as specified and directed by Engineer-In-Charge.
S&F in repair satinless steel finils, fancy type as approved by GE, for 25 mm curtain rods complete all as specified and directed by Engineer-In-Charge.
S&F in repairs 15 mm size bib tap, with wall glange, long body, cast copper alloy chromium plated, fancy type with capston head, screwed for 15 mm bore iron pipe or for brass ferrule and fixed complete all as specified.
S&F in repairs Brass chromium plated shower rose 80 mm dia without swivel joints, including fixing to steel pipe or union complete all as specified .
S&F in repair 15 mm size Concealed stop cock, cast copper alloy, chromium plated, Reduced body ISI Marked, screwed down, high pressure, with capston head, screwed externally both ends for unions etc. and fixed complete all as specified.
S&F in repair 15 mm size Angle valve, cast copper alloy, chromium plated, fancy type with capstan head, with screwed down, screwed both end for iron pipes complete.
S&F in repair 15 mm size pillar taps, cast copper alloy, chromium plated, fancy type, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repair 15 mm size basin mixer cast copper alloy chromium plated with capstan heads, half turn type, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe with 450 mm braided connection pipe (without pop-up)complete all as specified.
S & F in repairs 15 mm size wall mixer for mixing hot & cold water, cast copper alloy chromium plated with capstan heads, half turn type, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repairs CP mild steel gratings suitable for 75 / 100 mm dia NT/ FT complete all as specified.
S&F in repair Tubular towel rail stainless steel chromium plated 20 mm dia D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair white vitreous China wall hung, rimless bowl with flushing cistern With PP Soft Close Seat cover, Hinges, Dual Flush Cistern Fitting, Accessories Set, fixed in position including all fixing arrangement complete all as specified
S&F in repair white vitreous China wash down water closet pan (padestal pattern), fixed in position with fixing bolts, connection to drain pipe and to flushing pipe, etc., complete.
Supply and fix in repairs 10 Litre capacity PVC symphonic action type flushing cistern (ISI Marked) low level with inlet ball valve, float and handle & PVC flush pipe, fixed in position and connecting complete.
Supply and fix in repairs Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified.
S&F in repair PTMT connections 15 mm size with PTMT nuts of length 450 mm complete all as specified.
Supply and fix in repair white vitreous China wash hand basin (Flat back) of size 580 x 450 mm fixed on and including new brackets including 32 mm size brass chromium plated waste coupling, complete.
S&F in repair 32mm bore flexible pipe of PVC fixed to WHB / urinals as waste pipe (not less than 600mm long) including PVC coupling complete all as specified.
S&F in repair 32 mm size waste fittings, brass chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified.
S&F in repair 15 mm size Gun metal, globe or gate valves, with iron wheel head, screwed both ends for 15 mm bore iron pipe and fixed complete all as specified.
M&L for 18 to 20 mm thick granite (of any type) tiles machine cut & machine polished, set & jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over and including screed bed 20 mm thick in cement mortor 1:4 complete all as specified and directed. Note : Quoted rate shall be deemed to include cast of screed bed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard / dense soil, including removing of surplus soil complete all as specified and directed.
M&L PCC 1:4:8 Type D 2 using 40mm graded stone aggregate as in foundation, filling, mass concrete complete.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161, grade St.-240, complete all as specified and directed by Engineer-in-Charge.
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, wind Tie etc Fe 410-W (Gde E-250) quality A complete all as specified and directed by Engineer-in-Charge
M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint (first Quality) over one coat of red oxide primer complete all as specified.
Dismantling of roof sheet (any descriptions) including ridges in roof covering all as specified and directed.
S&F 0.50 mm thick Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall or roof, fixed with self drilling / tapping screws as specified and as directed by Engineer-in-charge
S&F in repairs single towel rail 600 mm long fixed in position all as directed
M&L for chequered cement concrete tiles of size 30 cm x 30 cm x 20 mm thick, with gray cement and pigment set & jointed with gray cement slurry and pointed with gray cement & pigment laid over and including 20 mm thick screed bed in CM 1:4 as in floors complete all as specified. Note : Quoted rate shall be deemed to include cast of screed bed.
Taking down cement plaster on brick wall, racking out joints hacking for key scrubbing down with water all as specified and directed.
M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete wall surfaces including mixing only water proofing compound as per manufacturers instruction and finishing the surface even and smooth without using extra cement complete all as specified. Note:- Waterproofing compound will be measured and paid seperatly.
M&L for Rendering 10 mm thick in cement and sand mortar 1:6 on brick work or cement concrete wall surfaces including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surface of ceiling, finished even and smooth without using extra cement.
M&L for Preparation of new plastered surfaces of walls, and applying two coat of cement base paint of any tint / shade all as specified.
M&L for Preparation of new plastered surfaces of ceiling and applying three coats white wash all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper (first Quality) over one coat of primer over and including 2 mm to 3 mm thick cement base wall care putty complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of existing treatment of wall / roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vacuum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour and applying 2 mm thick wall care putty, two coats of oil bound distemper (first Quality) of any tint / shade over one coat primer complete all as specified and directed.
M&L for Preparation of old decorated surfaces of walls, pillars, cornices by brooming down or steel brushing, scraping down smoke roots. moulds , moss and efflorescence salts, trading oil greasy spots etc. and applying one coat of oil bound distemper (first Quality) after removal of nails & filling nail hole with putty complete all as specified and directed by Engineer-in-charge.
M&L for Preparation of old decorated surfaces of walls, pillars, cornices by brooming down or steel brushing, scraping down smoke roots. moulds , moss and efflorescence salts, trading oil greasy spots etc. and applying two coats of oil bound distemper (first Quality) after removal of nails & filling nail hole with putty complete all as specified and directed by Engineer-in-charge.
M&L for Preparation of old decorated surfaces of ceiling, pillars, cornices by brooming down or steel brushing, scraping down smoke roots. moulds , moss and efflorescence salts, trading oil greasy spots etc. and applying one coat of oil bound distemper (first Quality) after removal of nails & filling nail hole with putty complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old painted surfaces of walls by washing, rubbing down & stopping etc, and applying one coat of cement base paint of any tint/shade all as specified.
M&L for preparation of old painted surfaces of steel of any description, not otherwise described over 10 cm width or girth, and applying one coat of synthetic enamel paint (first Quality) complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, including knotting and stopping holes and applying one coat of synthetic enamel paint (first Quality) complete all as specified and directed by Engineer-in-Charge
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries from site.
M&L premium / 1st quality coloured glazed ceramic tiles (digital printed) (joint free / edge cut) in vertical surfaces of size 300 mm x 450 mm x 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, laid over and including 10 mm thick backing coat in CM 1:3 complete all as specified and directed by Engineer-in-Charge. Note : Quoted rate shall be deemed to include cost of backing coat.
M&L for premium / 1st quality non skid ceramic coloured tiles (edge cut / Joint free) of size 300 mm x 300 mm x 7-8 mm thick as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles laid over and including 15 mm thick screed in CM 1:6 complete all as specified and directed by Engineer-in-Charge. Note : Quoted rate shall be deemed to include cost of screed bed.
M&L for premium / 1st quality coloured vitrified ceramic tiles (Double charged), 8-10 mm thick (square) polished, area of each tiles n.exc 0.36 sqm as in floors etc set and jointed in neat cement slurry and pointed in light white or coloured cement and pigment to match the tiles laid over and including 15 mm thick scree bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge. Note : Quoted rate shall be deemed to include cost of screed bed.
Demolition of existing roof treatment of any type
M&L for 15 mm thick screed plaster on RCC slab in CM 1:4 including mixing only water proofing compound as per manufacturers instruction and finishing the surface even and smooth without using extra cement complete all as specified. Note:- Waterproofing compound will be measured and paid seperatly.
M&L for water proofing treatment on roof surfaces in the following manner:- (a) The surfaces shall be painted with hot bitumen grade 30/40 confirming to IS-73 @ 1.20 kg / sqm over a coat of bituminous primer conforming to IS-3384 @ 0.30 ltr /sqm. (b) Supply & lay 3 mm thick APP water proofing membrane reinforced with non woven polyester matt laid using butane torch by torch application with a side lap of 10 cm & 15 cm end lap weighing not less than 3.5 kg / sqm. Note: - (i) Work to be carried out through authorised applicators of the manufactures and work will be carried out in complete / in patches in roofs (ii) Contractor shall submit written guarantee of 07(Seven) years from date of completion & submit security deposit @ 2.5% of executed amount or Rs 6250.00 which ever is more.
M&L for applying two coats of aluminium paint over APP membrane including preparation of surfaces and over one coat primer.
Deployment of manpower / tools etc for overhauling of Air blower of 5 to HP capacity by Opening of all parts such as suction air filter, bush, bearing, rotor, drum, bearing of motor shaft, Neck ring, coupling with studs between motor & air blower, cleaning, Oiling, Greasing and servicing of theise parts and re-assemble the same after greasing, oiling & cleaning etc, testing for smooth functioning complete all as specified and directed by Engineer-in-Charge. Note : - Deffective spares / parts shall be replaced with new spares / parts and new spares / parts will be measured & paid separately under appropriate items listed here-in-after as supply only.
Deployment of manpower / tools etc for taking out / lifting of unserviceable raw water non clog submersible pump set of capacity upto 10 HP, 3 phase 440 Volts, from raw sewage collection sump of STP plant well upto 15 metre depth at any location for overhauling, Oiling, Greasing and servicing by Opening of all parts, cleaning of bush, bearing, rotor, drum, motor shaft, Neck ring, coupling with studs between motor and re-assemble the same after greasing, oiling, testing and re-installation / Re-fixing / lowering in the sewage sump complete all as specified and directed by Engineer-in-Charge. Note : - Deffective spares / parts shall be replaced with new spares / parts and new spares / parts will be measured & paid separately under appropriate items listed here-in-after as supply only.
Deployment of manpower / tools etc for taking out Air blower pump / Fire fitting motor / water supply pumpset of rating 3 phase 440 Volts of capacity 5 to 15 HP from plateform at any location, transportation of same to contractor's work shop, dismantling for carrying out necessary repairs / renewal of parts of motors or pump and reassembling complete motors / pump sets, bring back to pump house and reinstallation, refixing & reconnecting in same location including testing complete all as directed. Note:- (i) Deffective spares / parts shall be replaced with new spares / parts and new spares / parts will be measured & paid separately under appropriate items listed here-in-after as supply only. (ii) Quoted rate shall be deemed included of transporting, repair, overhauling and replacement of spares complete
M&L for rewinding of motor of Air blower pump / Fire fitting motor / water supply pumpset of rating 3 phase 440 Volts of capacity 5 to 15 HP, by removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge
M&L for Repairing of pump by re-threading of worn out studs holes and supply and fixing over size studs with nut and washer complete all as specified and directed by Engineer-in-Charge
M&L for Re-metaling of motor shaft, of Air blower pump / Fire fitting motor / water supply pumpset of rating 3 phase 440 Volts of capacity 5 to 15 HP, turning to bring it to original size and shape and polishing of shaft complete all as directed
Supply only gun metal / stainless steel bush of motor of Air blower pump / Fire fitting motor / water supply pumpset of rating 3 phase 440 Volts of capacity 5 to 15 HP complete all as specified and directed by Engineer-in-Charge
Supply only driven end bearing of blower shaft of Air blower pump of 5 to 10 HP capacity complete all as specified and directed by Engineer-in-Charge
Supply only non driven end bearing of blower shaft of Air blower pump of 5 to 10 HP capacity complete all as specified and directed by Engineer-in-Charge
Supply and fixing gland and packing complete all as specified and directed by Engineer-in-Charge
Supply only coupling with studs between motor & air blower of capacity 5 to 10 HP complete all as specified and directed by Engineer-in-Charge
Supply only suction air filter of air blower of capacity 5 to 10 HP complete all as specified and directed by Engineer-in-Charge
Supply only suction silencer of air blower of capacity 5 to 10 HP complete all as specified and directed by Engineer-in-Charge
Supply only Neck ring complete all as specified and directed by Engineer-in-Charge
Deployment of manpower / tools etc for taking out / lifting of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volts at any location, transportation of same to contractor's work shop, dismantling for carrying out necessary repairs / renewal of parts of motors or pump and reassembling complete motors / pump sets, bring back to STP and reinstallation, refixing & reconnecting in same location including testing complete all as directed. Note:- (i) Deffective spares / parts shall be replaced with new spares / parts and new spares / parts will be measured & paid separately under appropriate items listed here-in-after as supply only. (ii) Quoted rate shall be deemed included of transporting, repair, overhauling and replacement of spares complete
M&L for rewinding of motor of non clog, raw effluent sewage lifting submersible pump set of capacity 7.5 HP of rating 3 phase 440 Volts, by removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled water proof copper winding wire, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge
Laboure only for Straightening of the slots of stator of submersible motor of any make.
Supply only thrust bearing block complete of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only gun metal bushes of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only sand guard of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only bronze metal impellars of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only shaft sleeve of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only set of gasket and O-ring of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only Mechanical seal motor end of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt.
Supply only Mechanical seal pump end of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only deep groove ball bearing motor side of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only groove ball bearing pump side of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only pump casing of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only intermediate casing of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only bearing housing of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only bearing cover of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only shaft protection sleeve of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only bowl, cast iron of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only bearing sleeve complete of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only rotor of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply only cable assembly of non clog, raw effluent sewage lifting submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volt
Supply and fix in replacement mild steel Nuts, bolt and washer, hexagonal full threaded 12 mm dia 100 mm long complete all as specified and directed by Engineer-in-Charge
Supply & filling of new Gear Oil Grade G-90 for Air Blower complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs air blower pulley, mild steel, 50 mm dia as per sample complete all as specified and directed by Engineer-in-Charge
Labour only for Strip opening of air blower and cleaning of air filters and air silencers with required material / liquid shop complete all as specified and directed by Engineer-in-Charge
Deployment of manpower for attending the complaint such as decarbonisation of terminals, rectification of phase reverseal, adjustment of relay, etc of Air Blower, Air Blower Motor, non clog submersible Pump, motor and all connected parts of STP upto 15 HP capacity, round the clock including Sunday & Holiday at any location in Lucknow Cantt area with in specified time not more than four hours complete all as specified and directed. Note :- Daily maintenance register shall be maintained for each Air Blower, Air Blower Motor, non clog submersible Pump, motor and all connected parts and shall be signed by representative of contractor and the Engineer in-Charge after doing necessary maintenance. (ii) Complaint shall be recitifed within 4 Hours from the time of complaint, failing which recovery shall be charge @ Rs. 50.00 per complaint per day.
Deployment of manpower / tools etc for cleaning of course bar screen chamber of size 3 x 4 x 4.5 metre of STP by taking out & Removing sludge, silt & all foreign object, by pumping set of required capacity, cleaning the internal surfaces wall & bottom with pressure washer, finaly cleaning with fresh water, disposed off sludge, silt & all foreign object to a distance not exceeding 1.5 KM away at such a place which is not determental to public health. complete all as specified and directed by Engineer-in-Charge.
Deployment of manpower / tools etc for cleaning of Fine bar screen, Oil & Grease Chamber of size 1.3 x 3 x 4.5 metre ( three Nos chambers) of STP by taking out & Removing sludge, silt & all foreign object, by pumping set of required capacity, cleaning the internal surfaces wall & bottom with pressure washer, finaly cleaning with fresh water, disposed off sludge, silt & all foreign object to a distance not exceeding 1.5 KM away at such a place which is not determental to public health. complete all as specified and directed by Engineer-in-Charge. Note:- Cleaning of all three chambers will be measured as 01 unit for payment.
Deployment of manpower / tools etc for cleaning of all MBBR Chamber of size 1.5 x 4 x 4.5 metre ( two Nos chambers) of STP by taking out & Removing sludge, silt & all foreign object, by pumping set of required capacity, cleaning the internal surfaces wall & bottom with pressure washer, finaly cleaning with fresh water, disposed off sludge, silt & all foreign object to a distance not exceeding 1.5 KM away at such a place which is not determental to public health. complete all as specified and directed by Engineer-in-Charge. Note:- Cleaning of all two chambers will be measured as 01 unit for payment.
Deployment of manpower / tools etc for cleaning of Tube Setteler Chamber of size 1.5 x 4 x 4.5 metre ( two Nos chambers) of STP by taking out & Removing sludge, silt & all foreign object, by pumping set of required capacity, cleaning the internal surfaces wall & bottom with pressure washer, finaly cleaning with fresh water, disposed off sludge, silt & all foreign object to a distance not exceeding 1.5 KM away at such a place which is not determental to public health. complete all as specified and directed by Engineer-in-Charge. Note:- Cleaning of all two chambers will be measured as 01 unit for payment.
Supply and pour Polypropylene bio Pac media in tube settler tank for Moving Bed Biofilm Reactor (MBBR) as per existing specified size to STP complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair bubble diffuser as per existing specified size fixed to STP complete all as specified and directed by Engineer-in-Charge
M&L for mild steel framed work for oil & Greece chamber and sludge drying bedas per existing specified size fabricated with mild steel angle / bar / T section / flat etc with and similar work using steel section conforming to Fe 290, Gde-E-165, and applying two coat epoxy paint over one coat primer including taking old work complete all as specified and directed by Engineer-in-Charge.
S&F in repair 75 mm bore mild steel black tubing heavy grade, cut to size and fixed for interconnection between various type of STP chambers, including taking down old tubing & fixing of new tubing, making good chambers with cement & snad mortar 1:3, applying two coats of epoxy paint with one coat of primer on internal & external surface of tubing complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair of pressure gauge o to 7 Kg/cm2 complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs three phase DOL starter panel with single phase preventor, MCB TPN 32 Amps 'C' Series, Voltmeter, ammeter and indication piolet lamps for three phase i.e. R.Y.B, having provision for mauanl / by pass and suitable for operating submersible pumps sets / blower motors 5 to 10 HP capacity complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs three phase automatic star delta starter panel with single phase preventor, MCB TPN 32 Amps 'C' Series, Voltmeter, ammeter and indication piolet lamps for three phase i.e. R.Y.B, having provision for mauanl by pass and suitable for operating submersible pumps sets / blower motors 5 to 10 HP capacity including all connected acessories in stater as per existing starter complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs bi-metallic overload relay with single phasing protection of range 2.5 to 4 Amps complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs bi-metallic overload relay with single phasing protection of range 6 to 10 Amps complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs bi-metallic overload relay with single phasing protection of range 10 to 20 Amps complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs power contactor ML-3, 3 Phase, 415 Volts current carrying capacity 4 to 25 Amps, coil voltage 220 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge
Supply & Fix in repairs MCB TPN 32 Amps, 440V AC 'C' series complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs Single Phase preventor to prevent single phasing, reverse phasing wiring & testing complete all as specified and directed by Engineer-in-Charge
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, bell, bell push, light fitting etc and making good disturbed surfaces of walls, floors,etc.as directed.
Taking down fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, bell, bell push, light fitting etc all as directed.
Material & Labour for concealed point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn existing concealed PVC conduit, including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, etc including pressed steel sunken type terminal box up to 8 module suitable for modular switch complete. Note:- Modular type cover plate & frame will be measured & paid separately
All as per Item No 167 above but for call bell point ontrolled by one bell push on independent board.
All as per Item No 167 above but for one 5 Amp socket outlet point on the same board with other switch controlled.
All as per Item No 167 above but for one 5 Amp socket outlet point on an independent board.
All as item No 167 herein before but using 2.5 sqmm , PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board.
S&F Modular white cover plate with frame 2 module
S&F Modular white cover plate with frame 3 module
S&F Modular white cover plate with frame 6 module
S&F Modular white cover plate with frame 8 module
S&F modular type one way switch, 6 Amp 240 volt in one moduel including connecting complete as specified and directed.
S&F modular type 6 Amp 5 pin universal socket in two moduel , 240 volts including connecting complete all as specified and directed.
S&F modular type one way switch, 16 Amp 240 volt in one moduel including connecting complete as specified and directed.
S&F modular type 6 / 16 Amp 5 pin universal socket suitable in two moduel , 240 volts including connecting complete all as specified and directed.
S&F modular type one way bell push, 6 Amp 240 volt in two moduel including connecting complete as specified and directed.
S&F ceiling rose polycarbonate body surface type three terminal complete as directed.
Supply & fix modular fan regulator 100 / 100 W, in 2 Module for ceiling fan and connecting as directed.
Material & Labour for concealed sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 25 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire in green colour, fixed on wall / ceiling, including taking down old sub main wiring complete. Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed.
S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed.
S&F in repairs VTPN distribution board, 4 way double door suitable for incommer 4 pole MCCB, 415 V & SP / TP MCB as outgoing, 200 Amps rated Busbar, inter connection link, cable ties, earth bar etc incl necessary civil works and electrical connections with suitable lugs / spreader links complete all as specified and directed by Engr-in-charge. Note: MCCB & MCB to be measured and paid seprately.
S&F MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, single pole & neutral 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, triple pole & neutral 63 Amp, 415 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCCB 100 Amps 415 volts, 4 pole 16 KA breaking capacity fixed in DB and connecting complete as directed.
S&F MCCB 125 Amps 415 volts, 4 pole 16 KA breaking capacity fixed in DB and connecting complete as directed.
Supply and Fix in repair LED lamp 10 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min), fixed in position complete..
Supply and Fix in repair LED lamp 15 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min), fixed in position complete..
Supply and fix in repair batten sutaible for 20 watt LED retrofit tube rod 1200 mm (approx) long, having both end bibin holder, internaly prewired, fixed to existing fitting complete all as directed.
Supply and fix in repair wall / surface mounting luminaires integrated LED Batten (4 feet) 20 W, 6500 K, 230V , system efficiency not les than 100 lumens / watt, with extruded aluminium housing with frosted PMMA / PC diffuser & integrated electronic driver fixed in position and connecting with ceiling rose complete all as per specified and directed by Engr-in-charge.
S&F recessed mounted 10 watt LED round downlight, 230 Volt AC, slim & elegant design for indoor application with high aesthetic appeal for soothing light CCT 6K, all as per exisiting size and shape including dismantling taking down unsv fitting any type complete all as specified and directed.
S&F in repair LED Building security light 35 Watt with high power LED source, system efficency not less than 110 lumen / watt), aluminium die casted housing, built in electronic driver, IP65 and IK 07 with 4 KV inbuilt surge protection including electrical connection with PVC three core copper conductor cable of size 1.5 sqmm, & all necessary fixing accessories, all as specified and directed by Engr-in-charge.
S&F in repair Polycarbonate meter fixing case of size 168 X 253 X 115 mm with transparent cover, IP 65 protection class with mounting plate including fixing of existing serviceable KWH meter and connection complete incl dismentling and taking down unsv one all as specified.
S&F service connection with twin core 6 Sqmm 240 volt heavy duty un armured PVC insulated solid aluminium conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than one metre apart including 4 mm GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete.
S&F service connection with three core 10 Sqmm 240 volt heavy duty un armured PVC insulated solid aluminium conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than one metre apart including 4 mm GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete.
M&L for overhauling of ceiling fan of any Make and sweep including dismantling, cleaning internally and externally, oiling, greasing, checking of electric connections, replacement of worn out check nuts, split pins, nuts, bolts and washers, sockets rebber real, clamps and minor repairing works and items etc. reassembling and testing on completion all as directed. Note :- rewinding works whereever required will be measured & paid seperatly.
M&L for overhauling of exhaust fan of any Make and sweep including dismantling, cleaning internally and externally, oiling, greasing, checking of electric connections, replacement of worn out check nuts, split pins, nuts, bolts and washers, sockets rebber real, clamps and minor repairing works and items etc. reassembling and testing on completion all as directed. Note :- rewinding works whereever required will be measured & paid seperatly.
M & L for rewinding of ceiling fan 1400 mm sweep of any make by dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge
M & L for rewinding of exhaust fan 300 mm sweep of any make by dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge
M & L for rewinding of exhaust fan 250 mm sweep of any make by dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge
M & L for rewinding of wall mounted fan 300 / 350 mm sweep of any make by dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge
Supply and fix in replacement steel ball bearing (6201ZZ) to ceiling / exhaust fan complete all as specified and directed.
Supply and fix in replacement steel ball bearing (6202ZZ) to ceiling / exhaust fan complete all as specified and directed.
Supply and fix in replacement steel ball bearing (6203ZZ) to ceiling / exhaust fan complete all as specified and directed.
Supply and fix in replacement condensor 2.5 MFD to ceiling fan
Supply and fix in replacement condensor 4 MFD to exhaust fan
Supply and fix in replacement Gun metal bush for ceiling fan or exhaust fan all as directed.
Supply and fix in replacement shaft suitable for any make of ceiling fans and exhaust fans all as directed.
Supply and fix in repair 300 size PVC square louvers for exhaust fan, fixed in position all as directed.
Taking down old detiorated, rusted out lived and unsv ceiling fan, supply & fix new ceiling fan 1200 mm sweep, BLDC copper wound motor, AC single phase, 230 volts, white colour complete with fan blade, down rod, canopy and provn of connection with three core flexible copper wire cable of size 1.50 sqmm from ceiling rose to fan, writing of MES Nos as approved size of letter complete all as specified and directed.
Taking down detiorated, rusted out lived and unsv exhaust fan, supply & fix new exhaust fan metal body 300 mm sweep, 900 RPM, copper bound motar, AC 230 volts, single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing, writing of MES Nos as approved size of letter complete all as specified and directed.
Taking down carefully storage type water heater (Geysers) of 25/50 ltrs capacity after disconnecting all electrical & water supply connection, reparing & overhauling the geyser by checking & tightining all connection, cleaning & descaling of tank, heating element, replacement of unserviceable parts, reassembling and refixing the geyser in same position including all electrical & water supply connection complete all as directed by Engr-in-Charge. Note : - Deffective spares / parts shall be replaced with new spares / parts and new spares / parts will be measured & paid separately under appropriate items listed here-in-after as supply only.
Supply only heating element 1500 watt push / screw/ triangular type suitable for 25 ltrs capacity geysers ISI marked complete all as directed by Engr-in-Charge.
Supply only heating element 2000 watt push/screw/ triangular type suitable for 50 ltrs capacity geysers ISI marked complete all as directed by Engr-in-Charge.
Supply only thermostat switch suitable for 25 / 50 Ltrs capacity geyser of any make/ type with temperature range adjustable from 25 to 90 degree centigrade superior quality 20 Amp rating 220 volt AC supply complete.
Supply only PVC flexible connection 600 mm with two PTMT adopter as per existing samples / suitable of carrying hot water / normal water complete .
Supply only indicator lamp suitable for 220 volts AC supply circular/ rectangular (green/ red) as per sample with neon lamp of superior quality complete .
M&L for preparation of old painted surface of Geyser of any size and applying two coat synthetic enamel paint with existing colour with spray machine all as directed
Taking down detiorated, rusted out lived and unsv water heater and Supply and fix water heater (Geyser) storage type 25 Ltr capacity (5 Star BEE rating) including PVC connections 15 mm size for hot and cold water and 3 core copper cable with plug top 15 Amp AC 230 V fixing on existing wall complete all as specified and directed. Note:- Geyser will be fitted with fastners-04 Nos including bolts washers etc and making good disturbed surface.
Supply and install & erect in true vertical position, steel tubular swaged pole type 410 SP - 31 (9 mtr long) complete with MS base plate of size 300 x 300 x 6mm thick at bottom, welded at the centre with through hole of 14mm dia at a height of 300 mm above the coping finial cap and painted with two coats of aluminium paint over a coat of red oxide primer with writing number including excavation up to required depth and PCC type C-2 1:3:6 (using 40mm graded) at bottom and PCC type B-1 1:2:4 (20mm graded) for mass filling and pole coping (60x60x30cm) and rendering of coping with 5 mm thick in 1:3 cement mortar complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in coping to electric pole and the like, weathering, slightly rounded or chamfered angles including necessary form work and dismentling of old coping complete.
M&L for Preparation of old painted surfaces of LT steel tubular pole 9 mtrs long and applying two coats aluminium paint from bottom to top and painting up to 1.5 mtr height from top of PCC coping with synthetic enamel paint one coat in black and Yellow / white alternate strip including re writing pole numbering in 8 cm height with one coat synthetic enamel paint complete all as specified & directed by Engineer –in-Charge.
Supply & fix / connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694, drawn through steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
Supply and fix in replacement of 45 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution . street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 100>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted IP 66 electronic LED driver with APFC, lower THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Supply and fix in replacement of 60 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted DriverTHD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Supply and fix in replacement of 90 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted Driver THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement . .
Supply and fixing in replacement of 70 W LED flood light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , flood light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted IP 66 electronic LED potted driver with open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD and provided with company LOGO ingraved on housing of the flood light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement
Supply and fixing in replacement of 120 W LED flood light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , flood light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted IP 66 electronic LED potted driver with open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD and provided with company LOGO ingraved on housing of the flood light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement
Supply and fixing in replacement of 170 W LED flood light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , flood light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted IP 66 electronic LED potted driver with open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD and provided with company LOGO ingraved on housing of the flood light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement
Supply and fix in replacement 40 watt LED Post top light fitting, energy saving 240V,50Hz AC, environmental friendly, aesthetically designed electronic constant current, IK07, having epoxy powder coated pressure die cast aluminium housing Top cover spun Al sheet powder coated,front cover Clear acrylic diffuser with indirect symmetrical light distributio, IP-65 luminaire with high power LED as light source of capacity 40 Watt, 5700K PF >0.9, THD<10% and light efficiency 85>_ ,CRI > 70,Surge protection 5KV incl dismentling taking down unsv fitting any type all as specified and directed.
Supply and fix in repair 10 to 12 watt LED bollard light fitting having epoxy powder coated pressure die cast aluminium housing Light optic / Diffuser - High impact polycarbonate / Optic colour temprature 5700K CRi>70,THD<10% PF >.90 surge protection 4 KV inbuilt, Rated voltage and frequency 240 Volt, 50 Hz street furniture with touch if aesthetic innovative design with uniformly lit diffuser at the upper portion acts a beacon of path guidance in a landsscape IP 65 environmental complete with foundation work nut,bolt and washer etc complete all as specified and directed by Engr in Charge.
Supply and fix in replacement security light Bracket made out of galvanised steel light grade pipe of 40 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos clamp made out of 50 mm x 5 mm flat iron and 06 sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply & fixing in replacement automatic street light timer panel 6 KW switch using Infrared Sensor based for automatic switching of street lights based on LUX level of natural light. Required illuminance for switching ON is < 30 Lux and for switching OFF > 10 Lux level. The sensor (nature switch) alongwith suitable power contactors, Input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming to IP-54 degree of protection including mounting bracket, cable glands, openable doors with lock complete all as specified & directed by Engr-in-Charge.
S&F in replacement wheather proof pole mounting junction box, base and door of junction box made out of SMC having outside dimention 333x233x120mm, inside dimention 300x200x105mm , single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body Complete all as directed by Engr-in-Charge
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft / loose soil for laying / taking up / taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Removing excavated soil from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Deployment of tools & manpower for Boring of hole under road / pavement / hard standing or any other situation by manual means suitable for passing of 40 to 80 mm bore pipe and making good both ends all specified and directed
M&L for 40 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old tubing complete all as specified and directed by Engr-in-Charge.
M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old tubing complete all as specified and directed by Engr-in-Charge.
M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old tubing complete all as specified and directed by Engr-in-Charge.
Supply, laying jointing and testing LT UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured IS 7098 marked, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core, laid in trench / laid under floor or fixed naked with wall / on wall / in ducts / in GI pipes etc. with and includings MS Clamps, nuts,bolts,washers complete all as specified and directed. Note- Excation, earth works, and sand cushioning, protection bricks and pipe will be measured and paid seprately under given items.
All as per item No 249 above but LT UG cable of size 16 Sqmm 4 core.
All as per item No 249 above but LT UG cable of size 35 Sqmm 3.5 core.
All as per item No 249 above but LT UG cable of size 95 Sqmm 3.5 core.
All as per item No 249 above but LT UG cable of size 240 Sqmm 3.5 core.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 25 to 50 sqmm XLPE armoured aluminium conductor .
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 70 to 95 sqmm XLPE armoured aluminium conductor
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 120 to 150 sqmm XLPE armoured aluminium conductor
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 185 to 340 sqmm XLPE armoured aluminium conductor
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and fixing connecting and testing of MCCB 63 Amps 3 pole 25 KA 415 Volt 50 Hz with spreader with suitable size of cable lugs / thimble complete including all electric connection with making good . All as specified and directed by Engr in charge.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and fixing connecting and testing of MCCB 100 Amps 3 pole 25 KA 415 Volt 50 Hz with spreader with suitable size of cable lugs/thimble complete including all electric connection with making good . All as specified and directed by Engr in charge.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and fixing connecting and testing of MCCB 125 Amps 3 pole 25 KA 415 Volt 50 Hz with spreader with suitable size of cable lugs/thimble complete including all electric connection with making good . All as specified and directed by Engr in charge.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and fixing connecting and testing of MCCB 250 Amps 3 pole 25 KA 415 Volt 50 Hz with spreader with suitable size of cable lugs/thimble complete including all electric connection with making good . All as specified and directed by Engr in charge.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and fixing connecting and testing of MCCB 400 Amps 3 pole 25 KA 415 Volt 50 Hz with spreader with suitable size of cable lugs/thimble complete including all electric connection with making good . All as specified and directed by Engr in charge.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip of size 32 x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
S&F 15 mm bore mild steel galvanised iron tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed on wall or laid on floor including taking down old unserviceable tubing complete all as specified and directed.
S&F 20 mm bore mild steel galvanised iron tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed on wall or laid on floor including taking down old unserviceable tubing complete all as specified and directed.
S&F 25 mm bore mild steel galvanised iron tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. laid in trenches / road crossing etc, including taking down old unserviceable tubing complete all as specified and directed.
S&F 40 mm bore mild steel galvanised iron tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. laid in trenches / road crossing etc, including taking down old unserviceable tubing complete all as specified and directed.
S&F 50 mm bore mild steel galvanised iron tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. laid in trenches / road crossing etc, including taking down old unserviceable tubing complete all as specified and directed.
S&F in repair 15 mm size Gun metal gate valve ISI marked with iron wheel head screwed both ends, conforming to IS, complete, all as specified and directed by Engr-In-Charge.
S&F in repair 20 mm size Gun metal gate valve ISI marked with iron wheel head screwed both ends, conforming to IS, complete, all as specified and directed by Engr-In-Charge.
S&F in repair 25 mm size Gun metal gate valve ISI marked with iron wheel head screwed both ends, conforming to IS, complete, all as specified and directed by Engr-In-Charge.
S&F in repair 40 mm size Gun metal gate valve ISI marked with iron wheel head screwed both ends, conforming to IS, complete, all as specified and directed by Engr-In-Charge.
Supply only Bleaching powder stable grade-I conforming to IS specification 1665/89 (second revision) minimum available chlorine percentage lay mass 34% (+) (-) 1% in 25 kg polythene HDPE bags duly marked date of manufacturing and batch No of fresh lot Note- The bleaching powder supplied by the contractor shall be got tested by the department for each lot from Govt reputed lab.The cost The charge for testing shall be borne by the contractor and cost of the same shall be deemed to be included in the rate quoted.
Supply only Chlorine test kit to measure chlorine 0.2 to 5 PPM.
M&L for cleaning of water reservoir of capacity 0.10 lakh galan by removing existing sludge from reservoir and depositing the sludge up to 100 Mtr distance and cleaning, scraping down deposit from floor and wall, washing the walls / floor with bleaching powder in the reservoir, including writing word with synthetic enamel paint on the wall (capacity, date of cleaning, date of next cleaning, location etc.) complete all as specified and directed.
S&F Hose pipe for fire fiting of 100 MM complete all as specified and directed by Engr in Charge.
Supply and fix in repairs 25 mm size Brass Handle valve (wafer type) lever operated, class PN-1.0, S.S-304 Disc, Nitrile / EPDM rubber lining including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs 32 mm size Brass Handle valve (wafer type) lever operated, class PN-1.0, S.S-304 Disc, Nitrile / EPDM rubber lining including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs 50 mm size Brass Handle valve (wafer type) lever operated, class PN-1.0, S.S-304 Disc, Nitrile / EPDM rubber lining including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs 80 mm size Brass Handle valve (wafer type) lever operated, class PN-1.0, S.S-304 Disc, Nitrile / EPDM rubber lining including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs 80 mm dia non return valve , cast iron complete all as specified and directed by Engineer-in-Charge.
Supply, installation, testing and commissioning outdoor LT Distribution Panel suitable for 3 phase, 4 wire, 415 volts to Hz supply system with suitable size and powder coating provided with suitable to make it dust/vermin proof. The panel shall be made with 3.00 mm thick CRCA sheet for outer shell and inner shell made out of 2 mm thick CRCA sheet, double door with front and back openable with locking arrangement, provision of thereaded earthing stud at bottom, inner shell completely vermin proof and to accommodate incoming / outgoing MCCB, MCBs and suitable rated TPN aluminum bus and extension links of rating not less than 1.5 times the rates capacity of the respective MCCBs. The TPN busbar and extensions link shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on epoxy regin insulator. All control wires shall be with 2.5 sqmm multistandad copper conductor wire and shall be properly bunched, tied ferruled for proper identification and crimped with adequate size of lugs. The panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground level and 45cm embedded in ground, computer cut self adhesive vinyl danger notice plate having conventional symbol of bone and skull be provided. The panel shall be for operating Non Clog Sewage Pump, Air Blower, Sewage disposal pump, Sludge Recycle pump, Pressure filter Pump consist of the following accessories and all specified and directed
(i) MCCB 4 Pole 63 Amps, 25 ka- 01 Nos (As Incomer) (ii) On load change over switch 63 Amps 4 pole 415 Volts -01 Nos (iii) For operating Non Clog Sewage Pump-06 Nos (2 HP) :- (a) MCB 4 Pole 10 Amps 10 KA 'C' Series-06 Nos (b) Power Contactor 9 Amps 02 set for each Pump-12 Nos (c) Thermal Over load relay 3-5 amps-06 Nos (d) Single Phase Preventer-06 Nos (iv) For operating Air Blower- 02 No,s(7.5 HP):- (a) MCB 4 Pole 16 Amps 10 KA 'C' Series-02 Nos (b) Power Contactor 12 Amps 02 set foe each Blower-04 Nos (c) Thermal Over load relay 9-15 amps-02 Nos (d) Single Phase Preventer-02 Nos (v) For operating Sewage disposal pump-02 No,s(7.5HP):- (a) MCB 4 Pole 16 Amps 10 KA 'C' Series-02 Nos (b) Power Contactor 12 Amps 02 set foe each Blower-04 Nos (c) Thermal Over load relay 9-15 amps-02 Nos (d) Single Phase Preventer-02 Nos
M/S ANIL ARORA (BID ID -3271597)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .