| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 CrAccepted-AOC | ₹3.7 Cr | L1 | Accepted-AOC Bid Accepted over all reasonable |
| 2 | L2₹4.4 Cr+₹69.8 L (18.9%)Rejected-Finance 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹4.4 Cr+₹69.8 L (18.9%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹4.9 Cr+₹1.2 Cr (33.8%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | ₹4.9 Cr+₹1.2 Cr (33.8%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹5.2 Cr+₹1.5 Cr (39.9%)Rejected-Finance CONGRESS BAZAR PATHANKOT 145 001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹5.2 Cr+₹1.5 Cr (39.9%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹5.5 Cr+₹1.8 Cr (47.7%)Rejected-Finance 300 GOPAL NIWAS 3 A ROAD SARDARPURA JODHPUR CITY RAJASTHAN 342003 | JODHPUR | RAJASTHAN | 342003 | ₹5.5 Cr+₹1.8 Cr (47.7%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹4.5 Cr
EMD Value
₹5.2 L
Closing Date
6 Dec 2021, 6:00 pmClosed
HQ CEJZ Jabalpur
HQ CEJZ Jabalpur MES Ridge Road Jabalpur Cantt 482001
PROVISION OF DEDICATED FEEDER AND ELECTRIC SUPPLY INGRASTRUCTURE FOR ZONE B and C AT JABALPUR
2021_MES_474691_1
752779A
Open Tender
Civil Works - Others
Lump-sum
545 days
Jabalpur
As per NIT
10 documents required · 10 mandatory
₹2,000
GE East jabalpur
₹5.2 L
Yes
5 Mar 2022
14 Sept 2021
8 Dec 2021
14 Sept 2021
6 Dec 2021
15 Nov 2021
Amount
SCHEDULE "A"
SCHEDULE "A" PART-I (Building Work) Lump sum price worked out by the contractor for 'Building Work' as listed in Schedule 'A' Part-I against the lump sum price inserted by the MES in schedule 'A' Part-I.
Sch 'A' Part-II ( Internal Water supply ) Lump sum price worked out by the contractor for Internal Water Supply as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES in schedule 'A' Part-II.
Sch 'A' Part-III ( Internal Electrification ) Lump sum price worked out by the contractor for 'Internal Electrification ' as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES in schedule 'A' Part-III.
Sch 'A' Part-IV (External Water supply ) Lump sum price worked out by the contractor for ' External Water Supply' as listed in Schedule 'A' Part-IVagainst the lump sum pricVe inserted by the MES in schedule 'A' Part-IV.
Sch 'A' Part-V (External Electrification ) Lump sum price worked out by the contractor for'External Electrification ' as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES in schedule 'A' Part-V.
Sch 'A' Part-VI (Road,Path and Culvert ) Lump sum price worked out by the contractor for'Road,Path and Culvert ' as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES in schedule 'A' Part-VI.
Sch 'A' Part-VII (Sewage Disposal ) Lump sum price worked out by the contractor for'Sewage Disposal ' as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES in schedule 'A' Part-VII.
Sch 'A' Part-VIII (Area Drainage ) Lump sum price worked out by the contractor for'Area Drainage ' as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES in schedule 'A' Part-VIII.
Sch 'A' Part-IX (Fencing & Gate ) Lump sum price worked out by the contractor for 'Fencing & Gate' as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES in schedule 'A' Part-IX.
Sch 'A' Part-X (Site clearance, excavation & earth works ) Lump sum price worked out by the contractor for'Site clearance, excavation & earth works ' as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES in schedule 'A' Part.X
Note for Srl No 2 to 11 The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount qouted by the contractor against Srl No. 2 to 11 by comparing it with the amount inserted / pre priced by the department and the same shall be applicable for the items of respective schedule
Schedule 'A' Part-XI (Miscellaneous works)
Item No 01 : S & F Bib taps cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15 mm bore dia of pipe complete all as specified and directed.
Item No 02 : S & F Stop valve cast copper alloy screwed down high pressure, fancy type chromium plated with long shank and cup (conceled type) screwed both ends for iron pipe suitable for 15 mm bore, complete all as specified and directed.
Item No 03 : S & F 20 mm bore Gun-metal gate valve cast copper alloy, screwed down high pressure with wheel head, screwed both ends with crutch or butterfly handle for iron pipes complete all as specified and directed.
Item No 03A : S & F pillar taps, 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed as in repair complete all as specified and directed.
Item No 04 : S & F Polythene (PVC) pipe connection suitable for 15 mm dia GI pipe/ stop cock/ pillar tap, 450 mm long including heavy brass union at each end, screwed one end to GI pipe & other end to stop cock/ pillar tap complete all as specified.
Internal Electrification
Item No 05 : M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories, heavy duty ISI marked after chasing in wall/ceiling etc, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
Item No 06 : Description all as per item No. 05 here in before but using 2.5 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly..
Item No 07 : BLANK
Item No 08 : BLANK
Item No 09 : S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
Item No 10 : BLANK
Item No 11 : BLANK
Item No 12 : S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Item No 13 : BLANK
Item No 14 : S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Item No 15 : BLANK
Item No 16 : S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap of make Bajaj, Havells, HPL complete all as specified and directed
Item No 17 : BLANK
Item No 18 : S & F for LED tube light fitting 10 watts batten aluminium extruded with decorative end caps complete all as specified and as directed. Make: philips Cat Part no. BN021LED12S 6500 PSU GR or equivalent in Wipro/Bajaj
Item No 19 : S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired with warranty option of 5 years from date of installation and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make: philips Cat Part no. WT140WLED7SCW PSU S1 PC or equivalent in Wipro/Bajaj
Item No 20 : S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make: philips Cat Part no. BN021CLED 22S PSU CW GR or equivalent in Wipro/Bajaj
Item No 21 : S & F for LED down light surface mounted round type 12 watts with aluminium die-cast body, finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation complete all as directed by Engineer - in - charge
Item No 22 : S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make: philips Cat Part no. DRP042PLED25 CWS LE S1 PSU GRP 4210 or equivalent in Wipro/Bajaj
Item No 23 : S & F for ceiling fan, 230 Volts, 1200 mm sweep with service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceiling rose to fan teriminal complete all as specified and as directed. Make: Usha/ Crompton/Bajaj
Item No 24 : S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in Sch "A" Part-I). Make: Havells / Crompton/Bajaj
Item No 25 : S& F for energy efficient exhaust fan of 450 mm sweep made of metal body Ventil Air-DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base complete all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in Sch 'A' Part-I.
Item No 26 : M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
External Electrical Supply
Item No 27 : S & F Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with "DANGER / 11 KV CABLE /MES or / DENGER / 11 KV HT JOINT / MES" embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and as directed.
Item No 28 : S & F Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with "DANGER / 33 KV CABLE /MES or / DENGER / 33 KV HT JOINT / MES" embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and as directed.
Item No 29 : Material and labour for boring hole under the road/pavment/hard standing with the help of trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 MPA working pressure not less than one metre below ground level complete all as specified and as directed by Engineer - in - charge at site. Note:- The cost of HDPE pipe shall be deemed to be included in quoted rate.
Item No 30 : Supply, laying, testing and commissioning of HT UG cables, 33000 Volts grade, 3 core x 240 Sq mm (Earthed), XLPE insulated and PVC shealhed, steel wire armoured, with multi stranded aluminum conductor, heavy duty conforming to latest relevant IS, cables laid in trenches. ducts. under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed. (MRS to COD Moderisation Sub Station.) NOTE:- Excavation of earth work, sand cushioning, cable protection covers, cable protection pipe shall be measured and paid under respective items in BOQ
Item No 31 : Supply, laying, testing and commissioning of HT UG cables, 11000 Volts grade, 3 core x 95 Sq mm (Earthed), XLPE insulated and PVC shealhed, steel wire armoured, with multi stranded aluminum conductor, heavy duty conforming to latest relevant IS, cables laid in trenches. ducts. under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed. (MRS at COD to 37 Pump House 2 Pole sreuxruew) NOTE:- Excavation of earth work, sand cushioning, cable protection covers, cable protection pipe shall be measured and paid under respective items in BOQ
Item No 32 : Supply, laying, testing and commissioning XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core x 150 Sqmm stranded aluminium conductor, 1100 bolts grade, of size 3.5 core x 150 Sqmm complete all as specified and directed. (Stn Tranformer at CMM to LT Panel) NOTE:- Excavation of earth work, sand cushioning, cable protection covers, cable protection pipe shall be measured and paid under respective items in BOQ
Item No 33 : supply and fix cable end jointing kit 11 KV grade cable for outdoor termination cold shrinkable push on type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size core x 95 sqmm complete all as specified and directed.
Item No 34 : supply and fix cable end jointing kit 11 KV grade cable for indoor termination cold shrinkable push on type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size core x 95 sqmm complete all as specified and directed.
Item No 35 : supply and fix cable jointing kit 11 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size core x 95 sqmm indoor/outdoor type complete all as specified and directed.
Item No 36 : supply and fix cable jointing kit 33 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable size 240 sqmm indoor/ outdoor type complete all as specified and directed.
Item No 37 : supply and fix cable jointing kit 33 KV grade cable for outdoor termination, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable size 240 sqmm indoor/ outdoor type complete all as specified and directed (Details as per Annexure-I).
Item No 38 : Supplying, instalation and erection in true vertical position steel tubular swaged welded pole for porvision of 4 pole structure complete with MS base plate 6mm thick and of size 300 x 300 mm, final taper, pole cap, bolts, nuts wahers & screws etc. pole made out of ERW M.S. tubing conforming to IS- 2713 part-II type 410 SP-55 (11 metre long) including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting with synthetic enamel Paint (First Grade/quality) black & yellow colour at lower portion of exposed pole starting from plinth block band of 1200 mm height ( 4 Nos each Strip of 150 mm width), painting pole No by the black paint by stenciled letters/ figures of 8 cm height complete all as specified and directed by Engineer - in - Charge. Note:- Earthwork, cement Concrete, cross arms etc. will be measured and paid seperaterly under approprite items.
Item No 39 : Supplying, install and erect in true vertical position steel tubular swaged welded pole for porvision of 2 pole structure complete with MS base plate 6mm thick and of size 300 x 300 mm, final taper, pole cap, bolts, nuts wahers & screws etc. pole made out of ERW M.S. tubing conforming to IS- 2713 part-II type 410 SP-55 (11 metre long) including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting with synthetic enamel Paint (First Grade/quality) black & yellow colour at lower portion of exposed pole starting from plinth block band of 1200 mm height ( 4 Nos each Strip of 150 mm width), painting pole No by the black paint by stenciled letters/ figures of 8 cm height complete all as specified and directed by Engineer - in - Charge. Note:- Earthwork, cement Concrete, cross arms etc. will be measured and paid under approprite
Item No 40 : Supplying, installing, fixing, commissioning and testing of Air break gang operated triple pole switch out door type with 15 Nos polymer based insulators suitable for 33 KV, HT 50 Hz of capacity 400 Amps rating with polymer based drop out fuse assembly with fuse carrier, fuse element (set 3 Nos) mounted insulators and fitted on steel frame horizontally operated (rotory type) mechanism from ground level consisting of operating rod of 25 mm bore heavy grade GI pipe of suitable length worked from ground level and with locking arrangement including pad locks, flat iron clamp 50 mm x 6 mm and MS channel of suitable size and length for fixing GOD including bolts, nuts, and washers complete all as specified and directed.
Item No 41 : Supplying, installing, fixing, commissioning and testing of Air break gang operated triple pole switch out door type of capacity 200 Amps AC mechanically operated mounted on polymer based insulators and steel frame with operating mechanism worked from ground level and polymer based Drop - out fuse set (set of 3 Nos), mounted on insulators with steel frame with expulsion fuse carriers and fuse element upto 25 Amp complete with locking arrangements incl pad locks with key complete suitable for 11KV, HT, 50 Hz complete all as specified and directed.
Item No 42 : Supplying and fix Lightening arrestor HT 33 KV, non linear resistor type conforming to IS 3070 (Part-1) 1993 complete, line discharge class-3, nominal discharge current 65 KA (peak), 34 KV rated system, voltage peak value high current implus of 4/10 micro sec wave shape 100 KA (peak) assembly suitable for 33 KV, long duration descharge class-II with insulation level 28 / 75 KV and mounted on hot dip galvanized steel structure including all clamps, nuts, bolts and washers and connecting to earth with 4 mm dia GI wire complete all as specified and directed.
Item No 43 : Supply and installation of 33 KV single phase outdoor oil cooled current transformer 33 KV, 50-25/ 5+5+1, 15 VA, burden accuracy class SP 10 for protection and 1.0 for metering, STC 25 KA complete all as specified and directed.
Item No 44 : Supply and installation of 33 KV single phase outdoor oil cooled Potential Transformer 33 KV/ rt 3/ 110 Volts/ rt3, minimum burden capacity 100 VA, accuracy class 1.0 with secondary protrcted by SP MCB complete all as specified and directed.
Item No 45 :- Supply, installation, testing and commissioning of HT 33 KV outdoor type None-xtensible SF6 insulated Fixed type manual Vacuum Circuit Breaker 25 KA for 3 phase, 50 HZ, 400 Amps as per IEC 13118/IEC-56 including indoor type C&R panel confomin to standard IEC 32271-100, totally enclosed in metal clad enclosure of suitable size with internal wiring etc. All live parts, bus bars, LBSs connections shall preferably be enclosed in one tank to avoid multiple inter connections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. also the VCB Switchgear) shall be type tested for internal arc test of 25 KA/1 sec AFLR as per IEC62271-200. Also manufacturers should submit type test reports for same. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. VCB should be complete with all accessories such as VPIS, cable supports for cable terinations, mechanical indications for load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056,60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000 mtr as per IEC 60120.
(ix) Cemophore 110 volts DC - 01 No. (x) 12 Window display for OTI, WTI, Bucholtz, trip and alarm etc - 01 Job. (xi) sufficient Nos of push button and indication lamp LED type as required fo each independent operation with back up Fuses as under (a) Red - Breaker Off (b) Yellow - Spring Charged (c ) Yellow - Auto Trip (d) Green - breaker ON (e) Yellow - DC Supply fail (f) Red - AB Switch (g) Green - Trip circuit Healthy (xii) Illumination lamp with holder operated with door limit switch, test terminal block, space heater, thermostat 30 to 90 degree centigrade, toggle switch for independent operation complete = 01 Job. (xiii) Interlocking arrangements between 33 KV Isolator and 33 KV VCB with limit switch - 01 Job. (C) Outdoor type current transformer 33 KV, 50 - 25 / 5+5+1, 15 VA, burden accuracy class 5P10 for protection and 1.0 for metering, STC 25 KA oil cooled dead tank type complete set of three - 01 Job. Make : As per Group I of list of makes
(D) ONAN Potential Transformer 33000 V / √3 / 110 V / √3, minimum capacity 100 VA, accuracy class 1.0 with secondary protected by SP MCB complete set of three - 01 Job. Make : As per Group I of list of makes (E) Supply and Install auxilliary power supply system for protection of panels complete with maintenance free lead acid batteries mounted on MS rack and connection complete in all aspects , with installled capacity 110V (2V volts x55) 100Ah, including 110V-25A booster and trickle charger, as per specifications and including DC DB for charger complete with DC ammeter , voltmeter, switches for 11/33 KV system complete with all controls .-01 Job Note:- Rate Quoted by the firm for this item should include the cost of the following:- (i) PCC work / any civil work for foundation required for errection of VCB and other accessories all as standard norns. (ii) Contractor shall submitt type test certificate to the engineer - in - charge / GE for approval placing the order. (iii) Any other item required to complete the job for any technical requirement as per CEA/NPERC. (iv) VCB shall be inspected by inspecting officer nominated by chief Engineer jabalpur zone at manufacturer factory and all routine test pertaining to IS shall be carried out. (v) Design, drawing of VCB to be submitted by the contractor for approval from the accepting officer before manufacturing.
Item No 46 :-Supply, installation, testing, and commissioning of Power Transformer step down, out door type SACADA compitable of capacity 1600 KVA, HT 33 KV/11 KV, 3 phase, 50 cycles AC with On Load Tap Changing arrangements with remote control panel operation on 33 KV sides to vary secondary voltage from (+)5% to (-) 15% in steps of 1.25% (16 steps), % impedance should not be less than 6.50% at normal / common tap No. 7 including suitable marshalling box and HV terminals 3 Nos outdoor bare bushings with socket and LV terminal connectors of copper to connect the transformer with HT XLPE Power cable of size 95 sqmm x 3 core with aluminum conductor and LV side additional Neutral with one No. solid porcelain type out door bushings with sockets on the transformer lid for earthing purpose complete in all respects with standard accessories and fittings conforming to IS-2026, HV( Primary) side delta and LV (Secondary) side star connected including control panel of Transformer. The salient features of the transformer shall be as under :- (a) (i) Transformer shall be Dyn - 11 vector group oil immersed naturally cooled, double wound copper winding core type, Radiator cooled MS tank complete with first fill of transformer oil as per IS -335 with ONAN cooling system. The temperature of oil shall not rise 45˚c to ambient 55˚c of winding. Transformer shall be painted with two coats of synthetic enamel paint with two coats of expoxy paint as per IS -632.
Standard Fittings :- (i) Rating and diagram plate alongwith levels where ever necessary. (ii) Earthing terminals - 2 Nos. (iii) Lifting lugs. (iv) Thermometer pocket with thermometer. (v) Air release hole with plug. (vi) Oil filling hole with plug on & incl. Conservator tank with drain valve and plug. (vii) Prismatic type oil indicator on one side of conservator tank with minimum and maximum oil level marking. (viii) Dehydrating breather - 01 No (ix) Oil conservator with drain valve and plug. (x) Sampling valves, top and bottom. (xi) Under base with flat treaded bi-directional rollers. (xii) Drain cum bottom filter valve with plug. (xiii) Top filter valve with plug. (xiv) Explosion vent with diaphragm and equalizer pipe (pressure release valve). (xv) Jacking lugs and hauling holes. (xvi) Inspection cover. (xvii) Detachable radiators with shut off valves between radiators and tank. (xviii) Radiator with air release hole and plug. Oil drain hole with plug and lifting eye all as per manufacturer's standards.
(xxi) Indoor floor mounted remote control cubicals (RTCC Panel , AVR relay) with rear accessories on HV side to vary secondary voitage as mentionrd above with wiring and followings :- (a) Remote tap position indicating meter digital type. (b) Tap change in progress signal lamps with belt (c) Raise / lower push buttons for remote operation (d) Inside illuminating lamp with door switch. (e) Supply on signals. (f) Suitable class CTs for 3 core to suit full load on transformer. NOTE :- (a) Single limb IMPULSE TEST AND HEAT RUN TEST shall be carried out at Manufacturers factory or approved laboratory and the rate for the same is deemed to be included in the quoted rate. Necessary Certificates shall be submitted by OEM before dispatchof Transformer. (b) Transformer shall be inspected by inspecting officers nominated by Chief Engineer Jabalpur Zone at manufacturers premises and all desired test shall be carried out in accordence to IS: 2026. (c) Site testing : Insulation resistance ,oil temperature alarm trip, Winding temperature alarm and trip, Bucholtz relay alarm and trip, Low oil level alarm, testing of annunciation systems by auxiliary relay triping of transformer, Polarity marking and phase sequence, Ratio test, vector group, magnetising current, dielectric strength and filtration if required should be carried out.
(d) Armoured control copper conductor cables of required size , length and core for making connections and functioning of all controll devices / panels / accessories shall be provided by firm all as required at site. The cost of the same are deemed to be included in he rate quoted by the Contractor. (e) Foundation and civil works as per manufacture's recommendation shall be provided at 'NO' extra cost to the dept. (f) Earthing shall be measured and paid separtely. (g) The stud for neutrals shall be of sufficient length to fix 2 Nos strip earthing. (h) Cost of cable entry box on 11 KV side for 1 run of 95 Sqmm , 3 core HT XLPE cable (E) deemed to be included in the item rate. (j) Routine test as per IS 2026 shall be conducted and test certificate shall be furnished. (k) The quoted price shall deemed to be inclusive of connecting of trip contacts of bucholtz relay and temperature indicator of windings & oil to the trip coil in panel board. (l) Cost of inintal oil filing with Transformer oil having die electric strengh not less than 70KV at 2.5mm gap deemed to be included in the item rate.
(m) RTCC and AV shall be suitable for automatic voltage regulation with master follower scheme with tap position indicator as per tap indication in the OLTC mechanism, RTCC should also be provided with contol gear in respect of fan ON/OFF indication, auto and manual control switch AC supply on and tap changer in progress indication lamp tap struck indication and alarm. (n) The erection of the transformer shall be done under the supervision of manufacturers authorized representative. Certificate in this regard shall be sumitted by the contractor duly signed by authorized representative of manufacturer and Engineer-in-Charge. (o) The design of transformer shall be in accordance to relevant clauses specified in PS . The accessories /devices not mentioned here but necessary to provide as per relevant standard , shall be provided by the firm without any extra cost. Make :- As per Group I of list of makes
Item No 47 :- install, testing and commissioning of Station Transformer step down, outdoor type, plinth mounted, maximum total losses in accordance to energy efficiency level 1 as per IS : 1180 (Part - 1), 33 / 0.433 KV, 50 Hz, 3 phase, copper wound, oil immersed naturally cooled delta connected on primary side (33 KV HV side) and Star connected on secondary side (433 Volts) in accordance with vector group Dyn 11 with neutral brought out on secondary side with tapping at +/- 2.5%, +/- 5%, +/- 7.5% off load tap changer gear in steps of 2.5%, continuous rating of capacity 100 KVA including initial fill of oil up to appropriate level and all standard fittings all as per IS : 1180 Part - 1, 1989 and IS : 2026 mounted on and including platform of size 2.0 mtr x 2.0 mtr x 2.0 mtr height (outer dimension) built with 150mm thick PCC 1:5:10, type E2 foundation extending 150mm on both sides of wall 350mm thick of brick masonry built in CM 1:6, 450mm below GL and 1550 mm above GL duly plastered in CM 1:4 on exposed faces and flushing same mortar as the work proceeds on faces in contact with soil / floor of 50mm PCC 1:2:4, Type B1 laid in bays 100mm thick hard core over approved earth filing complete all as specified and directed. The unit rate includes the cost of following accessories / fittings:
(a) Rating and terminal marking plate non detachable. (b) Earthing terminal with lugs - 02 Nos. (c ) Lifting lugs for top cover of main tank. (d) Thermometer pocket with dial type thermometer. (e) Externally hand operated off circuit tap changing device with locking arrangements. (f) Oil Conservator tank with filling hole, drain plug, prismatic oil level gauge. (g) Silica gel dehydrating breather charged with silicagel. (h) Top filler valve with plug. (i) Drain valve with plug. (j) Air vent and explosion vent. (k) Lifting hooks for transformer. (l) Unidirectional reversible roller - 04 Nos. (m) HV bushing - 03 Nos and LV side cable box with extended copper bus bar suitable for 150 Sqmm LT cable one run. 04 Nos.( 3 Phase +1 Neutral) (n) Radiators (o) Arching horns on HT side - 03 Nos. (p) Terminal connection on HV bushing. (r) Additional neutral separately brought outside LV cable end box with bush insulator for neutral earthing. (s) First fill of Transformer oil up to appropriate level. (t) Base channel 100 x 50mm of suitable length duly fixed on platform / plinth including making locking arrangement.
(u) Transformer shall be inspected by inspecting officer nominated by Chief Engineer Jabalpur Zone at Manufacturer factory and all routine test pertaining to IS 2026 shall be carried out. Make : As per Group I of list of makes
Item No 48 :- Supply, install, testing and commissioning of 11 KV Outdoor type RMU extensible IP54 floor mounted with internal copper bus bars, consisting of fixed type Motorised Vacuum Circuit Breakers-02 Nos as incomer, bus coupler -01 No and fixed type Motorised Vacuum Circuit Breakers-02 Nos as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple inter connections & sealed for life robotically for three sides and one side manual welded non magnetic / non ferrite / stainless steel tank Grade 304 of minimum 2.5 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 & 603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation. RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. The unit rate shall include the following with all necessary standard fitting required at site. RMU should be tested for an internal arc fault of 21kA for 1 sec as per IEC62271-200 and paint shade and thickness should be as per AIS 632 IS -5. complete all as specified and as directed.
The outer enclosure shall cover the full length of the switch gear, to ensure IP55 protection for full door covering of complete switchgear (Approved MAKE: As per Group I of list of makes) The unit shall include the following with all necessary standard fittings as required at site and incorporating the following accessories : (a) 2 Nos. incomer & 2 Nos. Outgoing : (i) 630A Vacuum Circuit Breaker module for making and breaking of fault current alongwith Earth Switch of full making capacity. (ii) Short time breaking current - 21KA/ 3 Sec. Making Capacity - 52.5KA (iii) internal Arc - 21KA/1 Sec (iv) Nominal operating gas pressure 1.3 (minimum) Bar abs. (v) Power frequency withstand voltage - 28KV (vi) impulse withstand voltage- 75KV (vii) Outdoor Enclosure- IP54 (viii) Front cover mechanism - IP2X (ix) Cable covers -3X (x) stored Energy mechanism for Motor operation - 24VDC (xi) Cable box for front termination of the cable suitable upto 3 core 400 Sqmm, 11 KV XLPE cable
(xii) Operation Counter (xiii) Self-Powered Microprocessor based Relay (3 O/C & E/f) with RS485 port and with standard settings - ADR241S (xiv) Digital Multifunction meter (A, V, KW, KVA, F, PF) with Rs 485 port type Rishabh/Elmeasure (not applicable for Bus Coupler VCB) (xv) Protection CT-50-100/1A, CI - 5P10, 2.5VA burrden (not applicable for bus coupler VCB) (XVI) Metering CT - 50-100/1A, CI-0.5, 2.5 VA Burden (not applicable for Bus Coupler VCB) (xvii) Suitable site replaceable Cable bushings (xviii) Arc proof cable covers with self interlocking mechanism between doors, earth switch, disconnector & VCB (xix) Capacitive voltage indication fixed type system (xx) Mechanical indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged. (B) Direct cable Module - 1 No.: (i) 630A Vacuum Circuit Breaker module (ii) Short time current - 21KA/ 3 sec (iii) Internal Arc - 21 KA/ 1Sec (iv) Nominal operating gas pressure - 1.3 (minimum) Bar abs. (v) Power frequency withstand voltage - 28KV (vi) impulse withstand boltage - 75KV (vii) Outdoor Enclosure - IP54 (viii) Front cover mechanism - IP2X (ix) Cable covers - 3X
(x) Stored Energy mechanism for Motor operation - 24 VDC (xi) Cable box for front termination of the cable suitable upto 3 core 400 Sqmm, 11KV XLPE cable (xii) Suitable site replaceable Cable bushings (xiii) Arc proof cable covers with self interlocking mechanism between doors, earth switch, disconnector & VCB (xiv) Capacity Voltage indication fixed type system (xv) Mechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged. (c) Bus Connected PT Unit -01 No. for Metering consisting of following:- (i) Type M: Air Insulated metering module 12KV, 630A, 21KA for 1 sec. -3 Voltage Transformers of the ratio 11KV/√3 / 110V√3, 50 VA, Class 1.0 with HT fuses on primary side and MCB on Secondary side. (ii) 1 LED illumination (iii) 1 Space Heater with thermostat. (iv) RYB phase indications (v) 1 No. Digital Voltmeter (c) 2x12 V Battery with battery charger with suitable burden for motor operation. input 230 v AC & Output 24 V DC.
(d) Capacitive Voltage indication fixed type VPIS 9-15 KV (e) Necessary interlocking arrangement for safety and ooperations (f) One No. Operation Handle for Manual Operation (g) One No. Manometer (h) Safety interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions. (j) Above switchgear shall confirm to all relevant IEC/IS standards. (k) Manual operation of Vacuum Circuit Breker should be possible without dismantling the motor from RMU. The motor should be fitted in such a way that it should not be outside front covers of RMU. (l) Operation and instruction mannual with drawings - 01 Set. (m) All cable bushing should be replaceable type. (n) Module should be accommodated as per manufacture's design. (o) RMU cable box shall be front accessible type to have easy access to protection and metering CTs.
(p) Master trip Relay, auxillary relays for tranformer fault (Buchhloz's relay alarm, trip, oil and winding temp - only for 2 nos. Outgoing VCB (q) 12 Window display for OTI, WTI, Bucholtz, trip and alarm etc. - only for 2 nos. outgoing VCB (r) Local Remote switch (s) Hooter - 2 nos. (t) Auxiliary power supply - Single phase Auxiliary Transformer - 11kV/230V AC for input to battery charger (u) Connection between cable riser panel & coupler VCB shall be cable connected using touch proof kits and same shall be done by OEM only as per their recommended guidelines
(w) Vacuum Interrupter should be of same make. Cable box should be arc proof with bolted door and interlocked with respective earthing switches. Doors should be removable for the ease access to terminate cables. Note :- Rate Quoted by the firm for this item should include the cost of the following:- (i) PCC work/ any civil work for foundation required for errection of VCB and other accessories all as standard norns. (ii) Contractor shall submitt type test certificate to the Engr-in- Charge/ GE for approval for approval for placing the order. (iii) The contractor will be submitted the NABL accredited lab test reports of the RMU's in original and the same shall be produced well before claiming RAR payment of the RMU. (iv) RMU shall be inspected by inspecting officer nominated by Chief Engineer Jabalpur Zone at Manufacturer factory and all routine test pertaining to IS shall be carried out. (v) Design, drawing of RMU to be submitted by the contractor for approval from the accepting officer before manufacturing. Make : As per Group I of list of makes
Item No 49 :- Supply and install automatic power factor correction (APFC) panel factory made of 800 KVAR capacity ready to use design confiring to relevant IS rated for short circuit rating of 50 KA, front openable and lockable by keys having lowers and air vent, gasket and totally vermin proof and suitable for 11 KV, 3 phase 50 Hz, AC and housed in elegant enclosure fabricated from minimum 3.00 mm thick CRCA sheet, anti corrosive coating to achieve power factor from 0.9 to 0.99 and finally powder coated in texture seimens gray RAL 7032 & as directed by Engineer-in-Charge comprising of and including following including suitable size and length of copper conductor cable from main panel to APFC panel for connections as approved complete all as specified and directed:- (a) 800 Amp capacity for pahse and neutral Copper bus bar duly insulated with colour coaded heat shrinkable sleeves and mounted on suitable DMC/epoxy insulators.
(j) Auto/ Manual switch-01 No. (k) Fuse for line protection as per requirement and as approved (l) Indicator lamp LED based with lamp holder as per requirement and as approved (m) Current transformer (CT) of ratio 250/5 A ,measuring class accuracy 0.50 to 1.0 for capacitor panel. (q) Suitable ACB 11 KV, thermal magnetic type breaking capacity 50 KA with microprocessor release with 8 step overload adjustability - 01 No (in coming) (r) Detuning reactor of suitable size shall be provided to maintain THD less than 7 percent. (s) APFC Panel shall be inspected by inspecting officer nominated by Chief Engineer Jabalpur Zone at Manufacturer factory and all routine test as per IS shall be carried out. Make : As per Group I of list of makes
Item No 50 :- Supply, installation, commissioning and testing indoor type LT wall mounting Panel Board of minimum size 1.50 m (height) x 1.20 m (breath) x 0.30m (depth) factory made CPRI approved panel, weather, dust & vermin proof indoor, double door, front openable, including four comparment for fixing of MCB TPN and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel CRCA sheet with suitable size angle iron supporting frame including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with copper wire and connections of all outgoing / incomming existing cable of any size complete all as directed by Engineer-in-Charge. (Station Tranformer LT Panel)
OUTGOING:- (a) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable thermal magnetic release, Rotary handle including all fixing accessories with both ends spreader links -02 Nos. (Battery Charger) (b) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 40 Amps, adjustable thermal magnetic release, Rotary handle including all fixing accessories with both ends spreader links -02 Nos. (SS Bldg, Security lights) (c) Multifunctional Digial type timer Switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Supply - 01 No (d) All connections from MCCBs to busbar & busbar to MCCB shall be made with suitable size of copper strip thimble lugs cost of which included in the quoted rate of items. (e) Power contractor 32 amps 3 Pole 415 Volts AC - 01 No
(f) All accessories prewired with copper conductor cable multistranded pvc insulated with aluminium thimble lugs etc (g) Above all complete in all respect including installation of panel including supply and installtion of frame pedestal 600mm and 450mm high above ground level Make : As per Group I of list of makes
Item No 51 :- S & F Junction Box for Street Lights of size 300 x 250 x 150 mm made out of CRCA sheet 2 mm thick totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 42 protection single leaf shutter in front having proper locking arrangements, and painted with powder coating paint and suitable size of "connectwell" stud teriminal (provision for socket bolting)- 05 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 06 amps- 01 No and mounted on security light pole with suitable bracket nuts, bolts complete all as specified and directed.
Item No 52 :- S & F for Energy saving new generation environmental friendly LED street light luminaire with long life versatile pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection with high power LEDs as light source and electronic driver with warranty option of 5 years from date of installation of capacity 45 watts with pre wired and necessary mounting arrangements including provision of 4 sq mm three core copper conductor cable multi stranded from fitting to junction box and including necessary GI pipe medium grade of suitable dia braket 1.5 mtr long bend to required shape with suitable with MS clamps made out of flat iron of size 40 x 6 mm - 02 sets, bolt & nuts complete all as directed. .
Item No 53 :- M&L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to copper strip of size 25 x 3 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earth work GI pipe 20mm dia medium grade for watering PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to Tranformer neutral as indicated including testing complete all as specified and as directed. Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
Item No 54 :- M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strip of size 32 x 6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earth work GI pipe 20mm dia medium grade for watering PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to Panel board/Tranformer body, APFC Panel, VCBs etc as indicated including testing complete all as specified and as directed. Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
Item No 55 :- BLANK
Road & Path
Item No 56 : M & L Machine pressed precast concrete interlocking paver block glossy finish any shape and size of 60 mm thickness with grey cement and pigment complete all as specified and directed.
Item No 57 : M & L Machine pressed precast concrete interlocking paver block glossy finish any shape and size of 80 mm thickness with grey cement and pigment complete all as specified and directed.
Sewage Disposal
Item No 58 : M&L for DWCPE (SN8) 180 (OD)/163(ID) mm diameter Pipes laid on 150 mm thick bed with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonary /RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sever line functional 0.70m to 1.65 m deep.
Item No 59 : M&L for 25 users RCC septic tanks designed to carry sewage and sullage water excavation in any type of soil. Foundation in in PCC 1:2:4, RCC M-25 design mix in wall base slab, buffle walls and roof slab incl beams etc with vent shaft, manhole opeining with conver connection etc complete including all excavation & earth works in any type of soil, all as specified and as shown on drawing.
Item No 60 : Soakage wells exc, In ordinary soil, foundation in PCC 1:3:6 wells of honey combed and solid in M-25 concrete, interlocking chamber, screen chamber brick work in CM, RCC cover slab in M-25/RR masonary / filling with brick bats, complete of size 1.20 dia x 3.00 M Deep.
SAGGI ELECTRIC COMPANY
Paragon Electrotechnics
Shekhar Enterprises
UTSAV INDIA LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .