GE (AF) SIRSA
GE AF Sirsa
REPAIR/MAINTENANCE OF SECURITY LIGHTS WITH ALLIED WORKS AT AT STN SIRSA
2021_MES_494695_1
GE/SRA/T-38 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
333 days
GE (AF) SIRSA
As per Tender and NIT
3 documents required · 3 mandatory
₹500
GE (AF) SIRSA
₹40,000
Yes
13 Jan 2022
14 Dec 2021
13 Jan 2022
14 Dec 2021
11 Jan 2022
28 Dec 2021
14 Dec 2021 - 23 Dec 2021
60 days
Amount
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Excavation/Cutting Road/ Hardstanding in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth and getting out, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing Surfaces and as directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 m and depositing where directed at a level not exc. 1.50 m above the starting point, complete all as specified and as directed.
M&L for Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Supply & laying in trenches Sub-class ‘B’ Bricks, kiln burnt, for Cable Protection, complete all as specified and as directed.
Laying in trenches Bricks (Serviceable Bricks obtained from Item No. 46 & 47 here-in-before), for Cable Protection, complete all as specified and as directed.
S&F PVC insulated Multi Stranded FRLSH Copper Conductor Cable 1.5 Sqmm unsheated, Single Core for connection of Street light fitting including taking down unserviceable Cable of any description, complete all as specified and as directed.
S&F PVC insulated Multi Stranded Copper Conductor Cable 1.5 Sqmm 3 Core, Round Flexible for connection of Street lght fitting including taking down unserviceable Cable of any description, complete all as specified and as directed.
S&F PVC Insulated Multi Stranded flat Service Aluminium Conductor Cable, 1100 Volt grade, heavy duty, served with inner sheathing of PVC tape and overall PVC sheathed of size 16 Sqmm 2 Core including taking down unserviceable Cable of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 20 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 30 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 45 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 50 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 60 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 80 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 90 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 120 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 180 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed. NOTE : FOR ITEM No. 11 TO 19 MAKE of Electronic Driver shall be provided as per Light Fittings make available at Site (Havells/Bajaj/Surya).
S&F PCB Card suitable for Multi LED Light Fitting of capacity 20 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 30 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 45 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed. NOTE : FOR ITEM No. 20 TO 22 MAKE of PCB Card shall be provided as per Light Fittings make available at Site (Havells/Bajaj/Surya).
S&F Surge Protection Device of capacity 10 KV Single Phase 50 Hz including taking down unserviceable Driver of any description, complete all as specified and as directed.
Material and labour for cable joint termination junction box PVC body housing of size 200x160x98 mm suitable for housing and including 100 amps rated aluminium bus bar, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tubular pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 to 10 amps MCB, SP, 240 volt for street light supply complete all as directed by Engr-in-charge.
S&F Connector suitable for fixing of Cable of size Cross sectional area 25 Sqmm to 50 Sqmm armoured/PVC for preventing of Short Circuiting of Cable in Junction Boxes, complete all as specified and as directed. NOTE : MAKE of Connector shall be provided as per Light Fittings make available at Site (Havells/Bajaj/Surya).
S&F LED Street light fitting 30 watts, New generation energy saving & environmental friendly, long life, powder coated pressure die cast aluminum, IP66 protection, high power LED street light with heat resistant toughened glass, corrosion resistant, isolated diver CRI >70, PF- 0.9, Surge Protection up to 2.0 KV, Color temp 6500K, Low heat generating LED make of LED shall be CREE/Nechia/Osram) complete making all connection using 1.5 sqmm copper conductor multi strand insulated 2 core flexible cable, complete all as specified & directed. Make- Havells/Philips/Polycab. NOTE: (a) The contractor shall obtain LM 79 & LM 80 report for light fittings manufactures for lot to be supplied and submitted to dept. (b) A Certificate from Manufactures for warranty up to 2 years shall be obtained and submitted to AGE/GE. (c) Any touch up of wall surface due to changing of bracket/fitting shall be done by contractor with similar surface finish without extra cost to the dept.
S&F LED Street light fitting 45 watts, New generation energy saving & environmental friendly, long life, powder coated pressure die cast aluminum, IP66 protection, high power LED street light with heat resistant toughened glass, corrosion resistant, isolated diver CRI >70, PF- 0.9, Surge Protection up to 2.0 KV, Color temp 6500K, Low heat generating LED make of LED shall be CREE/Nechia/Osram) complete making all connection using 1.5 sqmm copper conductor multi strand insulated 2 core flexible cable, complete all as specified & directed. Make- Havells/Philips/Polycab. NOTE: (a) The contractor shall obtain LM 79 & LM 80 report for light fittings manufactures for lot to be supplied and submitted to dept. (b) A Certificate from Manufactures for warranty up to 2 years shall be obtained and submitted to AGE/GE. (c) Any touch up of wall surface due to changing of bracket/fitting shall be done by contractor with similar surface finish without extra cost to the dept.
S&F Multi LED Flood Light Fitting of capacity 50 Watt with all Fittings including taking down unserviceable Light Fitting of any description, complete all as specified and as directed.
S&F Multi LED Flood Light Fitting of capacity 80 Watt with all Fittings including taking down unserviceable Light Fitting of any description, complete all as specified and as directed.
S&F Multi LED Street Light Fitting of capacity 120 Watt IP 66, having Die-cast Aluminium Housing, Weather Proof with Accessories including taking down unserviceable Street Light Fittings from the Electric Pole, complete all as specified and as directed.
M&L for replacement of Thermoplastics, Polyamide Glands with Lock Nuts Made of Poly amide of size M32 as per site requirement, complete all as specified and as directed.
S&F Multi LED Aviation light 6 Watt -500mm with IP-65 Protection 220 Volt 50 Hz, including taking down unserviceable Light Fitting of any description, complete all as specified and as directed.
S&F Multi LED Bollard 8 Watt -500mm with IP-65 Protection 220 Volt 50 Hz, including taking down unserviceable Light Fitting of any description, complete all as specified and as directed.
Demolition of concrete (coping of PCC/GI pole/Road) of any description and in any position complete and as directed by Engineer-in-charge.
M&L for Cement Concrete 1:3:6 C-2 (40mm graded crushe stone aggregate) as in Copping of Electric Poles, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork including dismantling PCC Copping and/or removing damaged PCC Copping, complete all as specified and as directed.
S & F GI Pipe Bracket made out of Galvanised Iron Tubing 40mm bore (dia), light grade, 1.50 m long bent to shape as per specified for fixing Street Light Fitting including taking down unserviceable GI Pipe Bracket, complete all as specified and as directed.
S & F Galvanised Steel Tubing Pipe 50mm bore (dia), light grade having 70 Cm to 100 Cm with long Bends, Each for Incoming and Outgoing Cables, grouting in Cement Concrete including taking down unserviceable GI Tubing of any description, complete all as specified and as directed. NOTE : Cement Concrete will be measured and paid for separately under appropriate Item.
S&F Rigid Steel Conduit 25mm dia exclusive of Boxes (Junction/ Terminal) but inclusive of all Tee, Bends, Elbows, Reducers, Bell mouth, etc. fixing Accessories suchs as Couplers, Lock Nuts, Saddles, Pipe Hook, etc. including taking down unserviceable Conduit of any description, complete all as specified and as directed.
Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Serviceable Pipes, Bricks, etc. and depositing to MES store yard for reuse complete all as specified and as directed. NOTE : Necessary Earth Work will be Measured and Paid under appropriate Items.
Making Hole under Road/ Hardstanding including cutting, etc. with manual anger or bookie not exc. 100mm dia, complete all as specified and as directed.
M&L for replacement of XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 10 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
M&L for replacement of XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 16 Sqmm 2 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
M&L for replacement of XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 25 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
M&L for replacement of XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 35 Sqmm 3.5 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
M&L for replacement of XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 50 Sqmm 3.5 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
Relaying XLPE Under Ground Cable of any description (Serviceable Cable obtained from Item No. 39 here-in-before) 1100 Volt grade, cross sectional area 10 Sqmm to 25 Sqmm 2/3½/4 Core after Fault rectification including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
Relaying XLPE Under Ground Cable of any description (Serviceable Cable obtained from Item No. 39 here-in-before) 1100 Volt grade, cross sectional area 35 Sqmm to 50 Sqmm, 3½/4 Core after Fault rectification including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
S& F Galvanised Steel Tubing Pipe 50mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 200 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for Bollard Light Fitting of capacity 8 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 50 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 60 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 80 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 90 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 120 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 180 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 200 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Bollard Light Fitting of capacity 8 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed. NOTE : FOR ITEM No. 49 TO 58 MAKE of PCB Card/Electronic Driver should be provided as per Light Fittings MAKE available at Site (Havells/Bajaj/Surya).
Supply and fix in repairs time digital switch with built in PCB for street light complete and as directed by Engineer-in-charge.
Supply & Fix in repairs LED Post top lantern of 1X40 Watt with die cast aluminium spigot and lid cover, high efficient LEDs and clear acrylic cover IP-65, complete all as specified and directed.
M & L for removal green vegetation and dressing around the plinth/PCC hardstanding up to 1.5 mtr of sub stations and 2/4 pole structure etc including disposal of vegitation /material up to 50 mtr distance from the site and levelling/surfacing the ground all as specified and as directed by Engr-in-Charge.
Trimming / chopping and cuting of branches each tree of any grith which are coming across/around the security light pole /fitting up to 3 meter all sides of the poles etc as required and removing the same from site of work complete all as directed by Engr in charge.
Material and labour for Painting to 9 mtr long steel tubular street light pole with Black & White strip 30 Cm a part alternaterly up to 1.5Mtr height from ground level with synthetic enmel paint with two coats of aluminium paint after removal of all dust from outer surface of the pole including numbering of pole complete all as directed by Engr-in-Charge.
M & L for Painting to 9 m long PCC street light pole in Black & White strip 30 Cm a part alternaterly up to 1.5Mtr height from ground level with synthetic enmel paint, after scraping, scretching, cleaning the old paint from the pole including writing pole Nos. & applying one coat of snowcem on PCC muff & remaining portion of the pole and aluminium paint for street light Jn box & bracket complete all as directed by Engr-in-Charge.
Supply, fabricating and fixing of MS clamps(duly painted with two coats of aluminium paint over a coat of red oxide primer) for fixing street light fittings/junction box/ cable pipe on wall/floor/pole including MS nuts, bolts & washers etc. as required as per site complete all as directed.
S&F Heat Shrinkable LT 1100 Volt Straight Through Joint suitable for Aluminium Conductor Cable, cross sectional area 25 Sqmm to 50 Sqmm, 3½ Core, complete all as specified and directed.
M&L for Galvanised Steel Tubing Pipe 80mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed. NOTE : FOR ITEM NO. 1 TO 67 (a) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. shall be arranged by the Contractor and Cost for the same shall deemed to be included in the Quoted Unit Rate. (b) Contractor or his Authorised Representitive has to inspect all Street/ Security Lights on Daily basis at this own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very Next day,given jobs/complaints should be rectified within 12 hr, and the delay is more than 12 Hrs period and GE/Engr-in-charge is not satisfied with the reason for delay than penalty at rate of Rs. 50 per complaint shall be deducted from dues of contract please note that is penalty is exclusively other than the condition 50 of IAFW-2249 and shall be treated as interim condition of contract. and if delay in individual jobs is notice and no claim whatsoever on this account shall be entertained by dept. The decision of accepting officer in this regard shall be final & binding (c) Contractor has to ensure serviceability at there own Vehicle/arrangement of all Street/ Security Lights of TECHNICAL, DOMESTIC & ZHOPRA AREA on Daily basis in any Weather Condition. (d) Contractor has to arrange own movable Generator of suitable capacity for repairing and testing of the Street/ Security Lights, defects rectification of Cables, etc. and to check the serviceability after repair. No Electricity shall be provided by the Department on this account. In the case of Day Time Street/ Security Lights be 'ON' by the Contractor, necessary recovery will be made as per CA Provision as recorded by Automation System. (e) Attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipments for remove the breakdown. Fault will be intimated through Telephone/ SMS and in case Contractor failed, recovery as per CA Provision will be made. (f) Repair Party will be reported every Morning and Evening to JE E/M. (g) Recovery Rate for non adhering of Instructions as Panalties will be made as per CA Provision. (h) Any Materials replaced which are not specified in SCHEDULE OF CREDIT will be deposited to MES STORE YARD without any extra Cost to the Department.
AMBIKA ENTERPRISES
shiv shanker enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .