Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | ₹9.5 L | L1 | Accepted-AOC First Lowest |
| 2 | L2₹10.3 LRejected-AOC H NO 168 KAPURTHALA ROAD RAJA GARDEN JALANDHAR PUNJAB 144002 | JALANDHAR | PUNJAB | 144002 | ₹10.3 L | L2 | Rejected-AOC Second Lowest |
| 3 | L3₹10.5 LRejected-AOC 03 RAJA GARDEN EXT KAPURTHALA ROAD JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | ₹10.5 L | L3 | Rejected-AOC Third Lowest |
Tender Value
₹10.6 L
EMD Value
₹21,300
Closing Date
16 Mar 2026, 5:00 pmClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B AND R BR JALANDHAR CANTT
CONSTRUCTION OF SELF HELP GROUP SHOP FOR SALE OF HANDMADE PRODUCTS AT DAC JALANDHAR (UNDER KIOSK SCHEME)
2026_CEPW_162724_1
Bid No 58 of 06/03/2026
Open Tender
Civil Works - Buildings
90 days
JALANDHAR
Please refer Tender documents.
13 documents required · 13 mandatory
₹5,000
₹21,300
Yes
7 May 2026
6 Mar 2026
17 Mar 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority :- EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B&R JALANDHAR
Name of Work :- DNIT FOR CONSTRUCTION OF SELF HELP GROUP SHOP FOR SALE OF HANDMADE PRODUCTS AT DAC JALANDHAR (UNDER KIOSK SCHEME)
Contract No: Civil Works
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Work Name Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 A1) BUILDING WORK GROUND FLOOR 2
2 Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. 3 Cum Excess(+) Full Conversion INR
4 Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres 5 Cum Excess(+) Full Conversion INR
5 Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. 6 Liter Excess(+) Full Conversion INR
6 Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type 7 Cum Excess(+) Full Conversion INR
7 Reinforced cement concrete M-20mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. 8 0.000 Cum Excess(+) Full Conversion INR
8 Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) 9 Sqm Excess(+) Full Conversion INR
9 First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth 10 0.000 Cum Excess(+) Full Conversion INR
10 Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steelreinforcement centring and shuttering in superstructure. 11 0.000 Cum Excess(+) Full Conversion INR
11 Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels 12 Sqm Excess(+) Full Conversion INR
12 Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 13 Sqm Excess(+) Full Conversion INR
13 Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete 14 0.000 Qtl Excess(+) Full Conversion INR
14 First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. 15 0.000 Cum Excess(+) Full Conversion INR
15 Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material 16 Sqm Excess(+) Full Conversion INR
16 Screed of 50mm thick cement concrete 1:8:16 with stone aggregate to be laid below the topping using mechanical mixer for mixing of material 17 Sqm Excess(+) Full Conversion INR
17 Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) a Size 600x600 mm 18 Sqm Excess(+) Full Conversion INR
18 Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge. a Size 600x600 mm. 19 Sqm Excess(+) Full Conversion INR
19 Extra Cost for using darker fast shade Vitrified or Rectified Tiles instead of lighter shades. 20 Sqm Excess(+) Full Conversion INR
20 Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : (i) Makrana, Doongri, Adanga viened and chack Doongri with grey stretches. (b) Slabs sizes above 0.50 sqm 21 Sqm Excess(+) Full Conversion INR
21 Marble work of thickness 12-15 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). (iv) Udaipur Green Marble Tiles of thickness 12mm to 15mm (b) Slabs sizes above 0.50 Sqm 22 Sqm Excess(+) Full Conversion INR
22 12.5 mm thick cement plaster 1:5 23 Sqm Excess(+) Full Conversion INR
23 20mm thick cement plaster 1:5 in two coat work 24 Sqm Excess(+) Full Conversion INR
24 12.5 mm thick cement plaster 1:4 25 Sqm Excess(+) Full Conversion INR
25 20mm thick cement plaster 1:4 in two coat work 26 Sqm Excess(+) Full Conversion INR
26 Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. 27 Sqm Excess(+) Full Conversion INR
27 Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded 28 Sqm Excess(+) Full Conversion INR
28 Bearing Plaster of 10 mm thick cement mortar 1:3 cement sand finished with a floating coat of neat cement and thick coat of Lime wash / P.O.P. on top of walls when dry for bearing of R.C.C. slabs & beams. 29 Sqm Excess(+) Full Conversion INR
29 Supplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. c) Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. 30 Metre Excess(+) Full Conversion INR
30 Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1 (1999): (a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- (iv) 35mm thick 31 Sqm Excess(+) Full Conversion INR
31 Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position 32 Qtl Excess(+) Full Conversion INR
32 Providing Polyester Powder coating 60 to 70 micron any coloured specified to M.S Grill section of various sizes including carriage of material from market to workshop & workshop to site of work. 33 Kgs Excess(+) Full Conversion INR
33 Providing and fixing hydraulic door closer ISI mark with necessary screw etc. Complete (c) I.S.I Designation No. III (size of door 851mm to 1000mm) 34 Each Excess(+) Full Conversion INR
34 Providing & fixing 6" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. 35 Each Excess(+) Full Conversion INR
35 Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) i) For shutter area up to 0.50 sqm 36 Sqm Excess(+) Full Conversion INR
36 Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : a) 300mm x 16mm 37 Each Excess(+) Full Conversion INR
37 Providing & fixing Glazing in Door, Window,ventilators & Partition etc.complete as per architectural drawings and the entire satisfaction of the Engineer-in-Charge (Cost of Gasket & Beading Shall be Paid as per Respective Item (i) Float Glass panes of 5.5 mm thickness 38 Sqm Excess(+) Full Conversion INR
38 Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventilators complete in all respect 39 Metre Excess(+) Full Conversion INR
39 Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flashwelded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) 40 Kgs Excess(+) Full Conversion INR
40 Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects 41 Sqm Excess(+) Full Conversion INR
41 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin- charge. 42 Each Excess(+) Full Conversion INR
42 Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish 43 Sqm Excess(+) Full Conversion INR
43 Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade 44 Sqm Excess(+) Full Conversion INR
44 Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. 45 Sqm Excess(+) Full Conversion INR
45 Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. 46 Sqm Excess(+) Full Conversion INR
46 Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm 47 Sqm Excess(+) Full Conversion INR
47 Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm 48 Sqm Excess(+) Full Conversion INR
48 Providing and fixing mineral fibre false ceiling tiles at height upto 4 mtr. of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire erformance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. i With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm 49 Sqm Excess(+) Full Conversion INR
49 B2) PUBLIC HEALTH 50
50 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 51
51 SDR 11 CPVC pipes & fittings 20mm o/d 52 Mtr Excess(+) Full Conversion INR
52 CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. 53
53 CPVC SDR 11 Pipe & fitting 20mm o/d 54 62 mtr 233.19 Excess(+) Full Conversion INR
54 Dismantling Concrete 55
55 Cement Concrete plain mix 1:2:4 56 Cum 1438.03 Excess(+) Full Conversion INR
56 Dismantling and Refixing of Interlocking Tile 80mm thick cement concrete Interlocking paver block and including restoration of roads to orginal Position. 57
57 FOR cpvc Pipe 58 Mtr 187 Excess(+) Full Conversion INR
58 Providing and fixing in position automatic brass Ball Cock in tanks. (b) Brass Ball Cock with rod and Plastic Ball 59
59 20 mm i/d 60 Nos Excess(+) Full Conversion INR
60 Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. 61
61 20mm i/d Brass Ball valves 62 Nos Excess(+) Full Conversion INR
62 Providing proposed water connection to house hold up to wall with providing, laying jointing testing GI pipe lines 15mm i/d B-Class (Above GL), Providing & fixing MDPE pipe 15 mm i/d with specials 2.00 mtr (Below GL) including cost of specials such as tees, bends, sockets, elbow, etc. cutting, threading and testing in trenches in the ground and ISI 15 mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with C.I bib cock, 15 mm i/d as per IS: 210 with stainless steel spindle of approved make 63 Each 1630 Excess(+) Full Conversion INR
63 Providing and Fixing 0.5 BHP Tullu Pump including fittings Complete 64 Each Excess(+) Full Conversion INR
64 Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonagepipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 65
65 Single Socket Type B 66
66 c) 90mm o/d SWR UPVC pipe lines laid complete 67 Mtr Excess(+) Full Conversion INR
67 Providing and fixing in position SS Gratingwith frame of approved make (to the approval of engineer in charge) complete in allrespects 68 Each Excess(+) Full Conversion INR
68 Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. 69
69 For 90 mm o/d pipes 70
70 ii) Single Tee With Door 71 Each Excess(+) Full Conversion INR
71 iii) Single Tee 72 Each Excess(+) Full Conversion INR
72 iv) Door Elbow 90 Degree 73 Each Excess(+) Full Conversion INR
73 v) Elbow 90 Degree 74 Each Excess(+) Full Conversion INR
74 xi) Single Y-Junction 75 Each Excess(+) Full Conversion INR
75 (viii) Coupler (Description Changed) 76 Each Excess(+) Full Conversion INR
76 Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. (i) Triple Layer Tanks 77
77 500 ltr Capacity 78 ltr Excess(+) Full Conversion INR
78 Cement concrete 1:2:4 79
79 a With stone ballast or shingle I mixing by manual means 80 Cum Excess(+) Full Conversion INR
80 Providing & fixing in position Water Dispenser Top Loading (with refrigration capacity 15 ltr) of approved make (to the approval of Engineer-in-charge ) dispensing hot/cold/ambient water including cost of two no. 20 ltrs packaged drinking water bottles and carriage complete in all respect. 81 Each Excess(+) Full Conversion INR
81 Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. 82 Each Excess(+) Full Conversion INR
82 Providing Double Door Refrigerator :- Supply,Installation and Comissioning of Frost Free Double Door Refrigerator capacity 250 Ltr - 265 Ltr complete in all respect. The Refrigerator shoud also conform to technical specifications attached herewith. Complete in all respect as approved and desired by the Engineer in-charges at site. 83 Each Excess(+) Full Conversion INR
83 Providing & Installing 3 Star split type wall mounted air conditioner capacity 1.5 tonne with arrangement for installing OD units including connection of inlet and outlet copper tubes (Rate is inclusive of copper pipe 3.00mtrs and cable upto 3.00mtrs length ) with proper insulation, cable link between ID unit and OD units stand for OD unit and concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects 84 Each "`"\ #,##0.00 Excess(+) Full Conversion INR
84 AUTOMATIC VOLTAGE STABLIZER: 85
85 Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- 86
86 Automatic Voltage Stablizer 3 KVA 87 Each "`"\ #,##0.99 Excess(+) Full Conversion INR
87 Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. 88
88 110 mm o/d pipes 89 mtr. Excess(+) Full Conversion INR
89 Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. 90
90 For depth exceeding 3.0 m but not exceeding 4.5 m B.G.L. For all classes of soil except rocky 91
91 (20 x 0.75 x 1.05) = 11.81 92 cum Excess(+) Full Conversion INR
92 Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement,R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 93
93 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal 94 Nos Excess(+) Full Conversion INR
94 Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. 95
95 100mm internal Diametre H.C.I. gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm 96 Nos Excess(+) Full Conversion INR
96 C-3) ELECTRICAL WORK 97
97 RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: 98
98 Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- 99
99 Wiring fan point (With fan box) 100 Each Excess(+) Full Conversion INR
100 Wiring light point 101 Each Excess(+) Full Conversion INR
101 Wiring 6Amp. Plug control comprising wall socket point 102 Each Excess(+) Full Conversion INR
102 Wiring 16/20Amp. power plug control point 103 Each Excess(+) Full Conversion INR
103 RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): 104
104 Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- 105
105 Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. 106 Each Excess(+) Full Conversion INR
106 PVC INSULATED FR COPPER CONDUCTOR CABLES: 107
107 Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 108
108 Overall size 1sq.mm (Un-sheathed) 109 P.Mtr Excess(+) Full Conversion INR
109 Overall size 2.5sq.mm (Un-sheathed) 110 P.Mtr Excess(+) Full Conversion INR
110 XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): 111
111 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- 112
112 Overall size 16sq.mm (2Core) Un-armoured (On-Surface) 113 P.Mtr Excess(+) Full Conversion INR
113 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: 114
114 Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 115
115 Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 116 P.Mtr Excess(+) Full Conversion INR
116 G.I. EARTHING: 117
117 Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). 118
118 Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 14Metre in length) 119 Each Excess(+) Full Conversion INR
119 G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):- 120
120 Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (Flushed) 121 P.mtr Excess(+) Full Conversion INR
121 MINIATURE CIRCUIT BREAKERS: 122
122 Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 123
123 MCB Single Pole 6-32amp. (10kA, Curve-C) 124 Each Excess(+) Full Conversion INR
124 MCB Double Pole 40amp. (10kA, Curve-C) 125 Each Excess(+) Full Conversion INR
125 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: 126
126 Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- 127
127 SP&N Double Door Distribution Board 4 way each 128 Each Excess(+) Full Conversion INR
128 Supply and erection of AC Ceiling Fan 1200mm (48")-3star suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body 3Nos of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The product should be complete in all aspects with fan motor, bladeset down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. 129 Each Excess(+) Full Conversion INR
129 Supply and erection of Recessed Mounted 2FT X 2 FT 36 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. 130 Each Excess(+) Full Conversion INR
130 Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %. complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab. 131 Each Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.18 MB
BOQ_329931.xls
BOQ • 0.42 MB
Technical_Conditions.pdf
Tender Documents • 0.49 MB
SBD.pdf
Tender Documents • 4.13 MB
Download all tender documents and submit your bid