Loading…
Loading…
Tender Value
₹3.2 Cr
EMD Value
₹6.4 L
Closing Date
10 Jul 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of "V/N" or "V" whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar Nature of Work are as follows for this work:-1) Erection & commissioning of 11/33 kV overhead lines. 2) Installation & commissioning of 11/33 kV Substation. 3) Installation & commissioning of 33kV Substation. 4) Laying & Commissioning of electrical cabling works of 11/33kV. 5) Any above work or combination of (i) to (iv) above.
15 conditions · 4 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested by which they/he is qualifying the Qualifying criteria mentioned in the tender document. It will not be obligatory on the part of tender committee to scrutinize beyond the submitted document of tenderer as far as his qualification for the tender is concerned. The railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under
No post tender correspondence shall be entertained after closing of tender even Suo moto post tender letters of the tenderers shall be treated as null/void.
The tenderers are required to observe the website to find out if any correction slips issued subsequent to uploading of the Tender . Railway reserves the right to make any additions/alterations to the tender uploaded and issue corrigendum to the same effect. In case the tenderer fails to take note of the above corrigendum, the additions and alterations entered/effected in the corrigendum shall be binding upon the tenderer and no claim what so ever will be entertained by Railway.
The tenderer should upload the documents carefully. The documents uploaded by tenderer should be clearly visible and in legible format.
Indian Railways Standard General Conditions of contract 2022 along with correction slips corrected up to date of closing of tender and the attached documents are part of the tender document.
The offers which are incomplete, without supporting documents, unsigned, conditional, will be summarily rejected.
As per letter No. 2022/CE-I/CT/GCC/Correspondence/ New Delhi, dated 14.05.2024 "On IREPS Module , a facility has already been created for online submission of Annexure-V. Therefore, the provision of downloading of Annexure-V of GCC & uploading of physically signed Annexure-V by tenderer had been discontinued on IREPS"
Provision of a dedicated and reliable 24x7 WS for drinking water, sanitation and platform washing , coach watering and other passenger use under ADEN/HQ/JBP sub division
JBP-L-T-No-15-2026R
JBP-L-T-No-15-2026R
Open
Works - General
12 Months
Jabalpur, Madhya Pradesh
₹0
₹6.4 L
10 Jul 2026
15 Jun 2026
26 Jun 2026
127 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,17,64,373.81 | ||
| — | Item Breakup | for details. | — | ||
| Design, Supply, Supervision of Erection, Testing and Commissioning of star 2 (EEL- 3/5 Star) rating Outdoor type Distribution Transformer of 1000 KVA, 11KV/415V, 3-Phase, 50Hz AC, Delta - Star winding, VectorGroup - Dyn11, Copper Wound, CRGO core, ONAN cooled, mineral oil immersed with all standard fittings as per IS1180 (part 1):2014 or latest. Transformer should be suitable for parallel operation and should include all accessories foundation etc The manufacturer shall possess BIS certification license/ certificate for the transformer. Star 2(EEL-3/5 Star) rating Transformer shall be supplied. | — | — | — | 39,97,840 | |
| — | Item Breakup | for details. | — | ||
| H-Beam 152 x 152 mm, 37.1 kg/Mtr,9 mtr long. Including overhead cross arms required for supporting cable , muffing, foundation earthing. | — | — | — | 1,85,415.3 | |
| — | Item Breakup | for details. | — | ||
| Supply, fabrication & fixing of MS channel /MS angle as per requirement on existing structurewith suitable clamps & nut bolts etc.with duly painted 2 coats of red oxide and 1 coat of Al paint | — | — | — | 81,158 | |
| — | Item Breakup | for details. | — | ||
| Supply. erection, testing &commissioning of 11KV/600 Amps Gang operated air break switch. vertical mounted.' outdoor type isolator witth three post type insulator per phase with DO fuses with suitable capacity of fuse elements mounted vertical cross arms. MS channels complete with galvanised down rod with pad lock ariangement conforming to relevent . The connection of jumper/cable to from transformer to AB DO will be done by the supplier of transformer. | — | — | — | 96,190.68 | |
| — | Item Breakup | for details. | — | ||
| supply,erection,testing and commissioning of VCB-11KV, Rating 800 Amp with control ,relay ,panel including Battery, Battery charger , copper armoured cable ,and all including nacessries accesries CG, ABB, simens, schinder or equivailent | — | — | — | 7,02,576.18 | |
| — | Item Breakup | for details. | — | ||
| Supply. erection, testing &commissioning of 11KV outdoor type single phase current transformer Make- SB (Switch Build) or equivailent It includes the supply of AAC conductor & other accessories for connecting the CT suitable including GI Structre , foundation earthing etc. | — | — | — | 73,733.55 | |
| — | Item Breakup | for details. | — | ||
| Supply. erection, testing &commissioning of 11KV outdoor type single phase potential transformer Make- SB (Switch Build) or equivailent It includes the supply of AAC conductor & other accessories for connecting the PT, foundation earthing | — | — | — | 73,733.55 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 11KV gapless metal oxide Lightening arrestor with complete hot dip galvenised bolts, nuts with washer etc to relevent ISS | — | — | — | 3,839.13 | |
| — | Item Breakup | for details. | — | ||
| Supply of operating rod suitable for operation on 11 KV clamps for removing DO fuse elements 06 mtrs (20 feet) lenth in four pieces of each 1.5 mtr complete with synthetic resin shield porcelain insulator with hand clips as per relevent ISS | — | — | — | 1,089.66 | |
| — | Item Breakup | for details. | — | ||
| Supply and fixing of danger board of standard size written in english and vernicular language for 33 KV and 11 KV system conforming to relevent ISS | — | — | — | 1,088.88 | |
| — | Item Breakup | for details. | — | ||
| Supply & spreading of (black stone) in the substation premises. | — | — | — | 61,663.2 | |
| — | Item Breakup | for details. | — | ||
| Foundation of cement concrete of ratio 1:3:6. The work shall include excavation and erection offoundation / concrete support as per relevant IS using cement concrete of ratio 1:3:6. Requiredmaterial shall be supplied by the contractor. | — | — | — | 74,384.6 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection ACSR dog Conductor IS 398 Part II/1996 with amended no1,2 and3(Reframed 2007) | — | — | — | 48,618 | |
| — | Item Breakup | for details. | — | ||
| Supply , connection, testing and commissioning APFC panel including all accersries required for fitting .(Each 125KVAR) Make - Servomax,AVTAR electrical or equivailent | — | — | — | 2,71,070 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of insulators for HT line pin type porcelain insulator, fixure, clamps, bolts, washer , GI Pin etc to relevent ISSfor 11KV line. | — | — | — | 3,194.64 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of insulators for HT line disc type porcelain insulator fixure, clamps, bolts, washer etc for 11 KV line. | — | — | — | 6,516.9 | |
| — | Item Breakup | for details. | — | ||
| Pipe Earthing : Supply of material for Earthing pit as per IS-3043, Erection includes excavation of earth, filling of salt, charcoal, B class GI pipe with funnel at top with cast iron cover having handle and cement concrete chamber, 8 SWG GI wire pit to SDB etc. as per IS latest with inscription ligibility of IR value on top of earth pit chamber with serial no-etc.Then testing with earth tester. | — | — | — | 29,198.88 | |
| — | Item Breakup | for details. | — | ||
| Supply & erection of 8 SWG GI wire | — | — | — | 1,972.5 | |
| — | Item Breakup | for details. | — | ||
| Supply & erection of GI earth strip 30/25 x 5 mm | — | — | — | 16,370 | |
| — | Item Breakup | for details. | — | ||
| Provision of maintenancefree earthing. | — | — | — | 1,43,343.36 | |
| — | Item Breakup | for details. | — | ||
| Excavation of Cable trench in Cement Concrete and laying of cable, 1000mm deep , 300mm wide The cable shall be suppliedfree of cost by Rly's which shall have to be transported by the contractor from Rly. depot,JBP to thesite | — | — | — | 36,173.25 | |
| — | Item Breakup | for details. | — | ||
| Cable laying single in earth. This involves Excavation of 1000mm deep trench in soil/hardmurrum/tar road/below Railway track. After this the cable shall be laid and then both sides are to becovered with bricks. The rest of the trench to be refilled by sheaved earth. The cable shall be suppliedfree of cost by Rly's which shall have to be transported by the contractor from Rly. depot,JBP to thesite | — | — | — | 25,105 | |
| — | Item Breakup | for details. | — | ||
| Double Cable laying in trench : This involves Excavation of 1000mm deep, 300 mm wide trench in soil/hard murrum/tar road/below Railway track . Then the bottom of the trench should be levelled , freed from stones / sharp edges of rocks . After this the cable shall be laid and then both sides are to be covered with bricks. The rest of the trench to be refilled by sheaved earth.Cables shall be supplied by Railways and the same shall be collected by the contractor from Electrical stores depot. | — | — | — | 37,800 | |
| — | Item Breakup | for details. | — | ||
| Cable laying on wall /pole and other similar places fixing using MS flat [25x6mm.]clamps, nuts, bolts,screws or nails as per site requirement | — | — | — | 8,679 | |
| — | Item Breakup | for details. | — | ||
| Pucca Cable trench: Construction of cable trench and laying of UG cable in 700 mm deep cable trench made of RCC with MS channel . This includes supply of all materials erection, commissioning of cable & trench etc. The laying of cable from transformer to the panel board shall be done in cable trench made of RCC complete with excavation of soil, construction of RCC wall for a height of 700 mm and inside width of 500 mm. Both wall and bottom surface of inside trench shall be finished with a fine coating of plaster. This constructed cable trench shall be covered with concrete slabs each of requisite width and a length of 1m. | — | — | — | 37,016.8 | |
| — | Item Breakup | for details. | — | ||
| Cable route marker; Supply & providing cable route markers marked with L.T./H.T. cable as required as perrelevant IS & at every turning points/road crossings and at 20mtrs distance | — | — | — | 934.05 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection 50 mm dia HDPE pipe with required accessories etc.make- Astral, Finolex, jain irrigation, polycabe, supreme, Duke Pipes, Texmo Pipes, Dolphin Poly JP polyplast , Tuffline technoplast , gurukripa or simillar | — | — | — | 20,428 | |
| — | Item Breakup | for details. | — | ||
| Provision & laying of HDPE pipe 4" dia in tack crossing including jointing etc. with requiredaccessories etc | — | — | — | 86,698 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing & commissioning of 11 KV Outdoor type heat shrinkable cable termination kit up to 3 core 300 Sq.mm | — | — | — | 40,338.03 | |
| — | Item Breakup | for details. | — | ||
| Supply & erection , testing & commissioning of indoor/outdoor LT heat shrinkable termination kit of 4core X 240-300 sq.mm. | — | — | — | 7,660.92 | |
| — | Item Breakup | for details. | — | ||
| Supply & fixing of GI pipe of 150mm dia B class with necessary bends & clamps etc. for laying the cable. | — | — | — | 83,411.4 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of 50 mm dia GI pipe B class. | — | — | — | 6,034.8 | |
| — | Item Breakup | for details. | — | ||
| Supply & fixing of GI pipe of B class for cable support -100 mm dia. | — | — | — | 37,408.8 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of anticlimbing device and fixing with suitable nuts, bolts and fixtures etc. onthe pole. | — | — | — | 5,778.6 | |
| — | Item Breakup | for details. | — | ||
| Supply , connection, testing and commissioning of Copper plate earting (Plate size 2FeetX 2Feet) | — | — | — | 44,388.12 | |
| — | Item Breakup | for details. | — | ||
| Supply & erection of G.I.strip size: 30 x 5 mm (1 Kg/M aprx) with required GI hardwares. | — | — | — | 8,185 | |
| — | Item Breakup | for details. | — | ||
| Supply & application of high solids (68-70%) thin film non hygroscopic water based weather resistance fire stop cable coating | — | — | — | 67,236.4 | |
| — | Item Breakup | for details. | — | ||
| Misc. items for supply : Supply of rubber matting 12 mm thick size 2M x 1M as per IS 5 nos,Fire extinguisher DCP type- 5 Kgs. capacity with ISI mark complete with fixing arrangement onMS angular frame of suitable size- 2nos, Shock treatment chart in English and Vernecularlanguage as per IE rules in wooden frame & glass top- 2 nos. | — | — | — | 12,131.86 | |
| — | Item Breakup | for details. | — | ||
| LT outdoor panel (water proof) made/fabricated out of 1.6 mm MS sheet duly painted with powder coated having suitablecopper bus bars, indicating lamps, multifunction meter, earthing, foundation, Suitable MS Channel , Glands, lugs etc. Incoming100 A, 4 pole 16kA MCCB (2 nos, 1 as spare) and outgoing 5 x 40A 4 pole MCCB 25 kA + 5 x 63A 4 pole MCCB 25kA. All theMCCBs shall be of Schnider, legrand, ABB, L&T make or equivalent. | — | — | — | 76,103.67 | |
| — | Item Breakup | for details. | — | ||
| SDB for light and fan. TPN DB 4 way (8+12) IP-43 with metal door, with 32A TPN incomer and outgoing having 5 x 10A SPMCB and 5 x 6A SPMCB MCB make- Legrand, ABB, L&T, Schnider, Hager, or equivalent | — | — | — | 5,313.83 | |
| — | Item Breakup | for details. | — | ||
| SDB for Power. TPN DB 4 way (8+12) IP-43 with metal door, with ELCB, RCCB 63A TPN incomer and outgoing having 5 x 32ASPMCB and 5 x 20/16A SP MCB make- Legrand, ABB, L&T, Schnider, Hager, or equivalent | — | — | — | 5,872.1 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of 1 x 18/20W LED fittings 4 feet length. The fittings shall have to be erected by the contractor with all fixingaccessories/MS clamps, nuts bolts etc. as per requirement at site. | — | — | — | 3,882.72 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of Ceiling fan including electronic modular fan regulator, suitable down rod, Metalfan hook, flexible Pipe, with all necessary arrangement (BLDC, 5 star rated, 1200 mm Make- Atomberg,Usha, Bajaj,Havells or similar make) | — | — | — | 6,862.02 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of E/Fan 380mm sweep: fixing is to be done on already provided finished opening in the wall using required fasteners, their grouting and thenconnection is to be given from ceiling rose to this fan using cable of 1.5 sq. mm. size Make- Atomberg,Usha, Bajaj,Havells or similar make | — | — | — | 5,467.16 | |
| — | Item Breakup | for details. | — | ||
| Point Wiring: This includes provision of wiring with 1.5 sqmm copper stranded PVC insulated wire [ L & N and earth ]fromMDB/SDB/ Board to light & fan control board and provision of control switch on common light and fan control board , together withwiring from control board to ceiling rose and provision of ceiling rose , holder on board ; with earth continuity wire; independent for each fitting. Cost of this item is inclusive of distributed cost of common board & wiring from MDB/SDB/Board to common board inaddition to items specifically mentioned Make-Legrand, ABB, L&T, Havells, or simillar make | — | — | — | 11,026.4 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x2.5 sqmm FRLS copper wire inside PVC Casing capping / Concelead withrunning earth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of 2.5 sqmm with onewire of 1.5 sqmm for earth conn). | — | — | — | 6,144 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x4 sqmm FRLS copper wire inside PVC Casing capping/ Concelead with runningearth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of4 sqmm with one wire of 2.5sqmm for earth conn). | — | — | — | 4,438.5 | |
| — | Item Breakup | for details. | — | ||
| 16A & 6 pin socket point on separate circuit and board. Make legrand, ABB, L&T, Havells or equivalent. | — | — | — | 2,347.68 | |
| — | Item Breakup | for details. | — | ||
| 5 pin 5A on separate boards: wires shall run separate from SDB Make legrand, ABB, L&T, Havells or equivalent. | — | — | — | 797.28 | |
| — | Item Breakup | for details. | — | ||
| 6A 5 pin socket point on fan and light control board Make legrand, ABB, L&T, Havells or equivalent. | — | — | — | 242.48 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modularswitches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened atthe time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. : Fourmodule box of Havells, Bajaj , Anchor or equivalent | — | — | — | 294.93 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modularswitches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened atthe time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. : Sixmodule box of Havells, Phillips, Orient, Bajaj or equivalent. | — | — | — | 629.88 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modularswitches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened atthe time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. : Eight module box of Havells, Phillips, Orient, Bajaj or equivalent. | — | — | — | 482.42 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modularswitches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened atthe time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. :Twelve/Eighteen module box of Havells, Phillips, Orient, Bajaj or equivalent. | — | — | — | 604.34 | |
| — | Item Breakup | for details. | — | ||
| PVC conduit 25 mm dia as per IS-9537 (HMS) | — | — | — | 1,952.4 | |
| — | Item Breakup | for details. | — | ||
| Cutting of wall for insertion of 1" dia PVC conduit, fixing hardware's for fixing the conduit along with its supply and then replaster itwith cement and sand mixture and then painting with matching colour as per existing colour of the wall. Proper joints in pipes,bends/elbows/ junctions are to be provided as per site requirement | — | — | — | 4,988.4 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 36 W LED street light fittings suitable for 230V AC, 50 Hz comprise a single piece deepdrawn alluminium housing IP-65 colour temp 5500- 7000K with connection etc. with 1.5mtr GI pipe suitable fixtures and clamps etc. Havells,Phillips, Orient, Bajaj or equivalent. | — | — | — | 27,406.8 | |
| — | Item Breakup | for details. | — | ||
| Supply, fabrication,erection,testing& commissioning of LT power panel 440V approx size 2.0(H)x2.5(L)x0.8(W) Mtrs made of 2 mm MSsheet with cover & locking arrangement duly painted with one coat of red oxide & power coating with required accessories for fixing asper Railways specification attached. The panel shall have Copper Bus Bar of size 120 mm x 10mm or suitable for main bus incoming.A. Incoming feeder I. 2x800Amps ACB 4 pole microprocessor release manual draw out type II.One no. Voltmeter (96x96mm) digitaltype (0-500V) with phase selector switch III. One no. Ammeter (96x96mm) digital type (0-1000V)CT operated 1000/5A with phaseselector switch IV. LED type indicating lamps for each phase B.Out going feeders I. 8x400 Amps 25KA 4P MCCB II. 4x200 Amps 25KA4P MCCB III. 3x100 Amps 25KA 4P MCCB IV. LED type indicating lamps. one for each MCCB. Hylum sheet 12mm shall be used toprovide poper insulation between MCCB & panel supports. Erection of panel shall include its fixing at site on suitable size of foundationand connection of various cables.The design of panel shall have to be got approved by competent authority before execution. | — | — | — | 21,33,765.6 | |
| — | Item Breakup | for details. | — | ||
| DTR S/s fencing (Total 37 feet running meter max.) of 6' height with chain link fencing on MSAngle(50x50x6mm) support 7 nos. 7' height. | — | — | — | 1,14,954 | |
| — | Item Breakup | for details. | — | ||
| Removing, Shifting,relaying of existing cable in trench, wall, soil, roof, track crossing, road crossing,cable tray, etc including MS clamp, nut, bolt, Screw, Nails,gland, lugs.Disconnection, proper reconnection,from panel or any other thing. | — | — | — | 15,120 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 220 HP VT pump 70 Mtrs head , discharge14100 LPM including all accesries , soft starter foundation for Gwarighat | — | — | — | 52,45,796.36 | |
| — | Item Breakup | for details. | — | ||
| Supply, Erection and Commissioning of 300 HP Vertical Turbine Pump at Narmada River The work pertains to the supply, erection, testing, and commissioning of a 300 HP Vertical Turbine Pump for the newly proposed sump well at the Narmada River. The detailed specifications, scope of work, and distribution of cost are enclosed herewith for reference and further necessary action. | — | — | — | 1,75,23,000 | |
| — | Item Breakup | for details. | — | ||
| Supply & erection OF 5MTRS OCTAGONAL POLE make- Bajaj, Crompton, Surya or equivalent along with base plate andfoundation along with arm for holding fitting | — | — | — | 1,28,475.8 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
15-2026R.pdf
ATTACHMENT
AC08to103.pdf
ATTACHMENT
Allcorrectionslip1.pdf
ATTACHMENT
ac112.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .