| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC NIL | THE NILGIRIS | TAMIL NADU | 638451 | L1 | Accepted-AOC being l1 | |
| 2 | L2₹28.5 L+₹1.5 L (5.63%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹28.7 L+₹1.7 L (6.24%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹28.7 L+₹1.7 L (6.47%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹30.7 L+₹3.8 L (13.9%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
18 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR AJIT CHOUDHARY
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
CERTAIN MISC B/R REPAIR IN MES QTR AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUNDA
2023_MES_610092_1
C/8885/E8
Open Tender
Civil Works
Item Rate
180 days
KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF KALAIKUNDA
₹60,000
Yes
6 Nov 2023
21 Jul 2023
19 Aug 2023
21 Jul 2023
18 Aug 2023
4 Aug 2023
Amount
Demolition of Cement Concrete of any description and in any position and removing of debris from premises and cleaning surfaces by brushing etc and washing down with water and removing dirt, dust etc complete all as specified and as directed.
Demolition of reinforced cement concrete roof (other than ground floor), beams,landings,chajjas and similar suspended works (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and as directed.
M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling with cement mortar (1:4) with using WPC as per manufacturers instruction over two coast of primer mixed of Latex and cement @ 1:4 (by weight) in the grooved portion and extended upto 100 mm both sides of groove complete all as specified and as directed.
M & L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in brick walls complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as directed.
Dismantling of stone slabs and tiles of any description or thickness as on platform, shelves, floors etc laid, bedded and pointed in any mortar complete all as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking down SWR pipes (any size or pattern), including all fittings, 'T', bends,etc., including removal to store for taking credit (measured overall as fixed along the centre line over fittings and accessories), complete all as directed.
Materials and Labour for brick work with Sub Class ‘B’ bricks straight or curved on plan exceeding 6M mean radius built in cement mortar (1:6), complete all as specified and directed.
M&L Brick work with sub class B bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and as directed.
Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles throating,and roof padding as directed including necessary from work complete all as specified and directed.
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection laid in bays with construction 6mm thick joints should be filled bitumen mastic filling comprising of one part of heated bitumen 80/100 grade and three part of sand all by weight complete all as specified and as directed.
Materials and Labour for 25 mm thick plain cement concrete M15 (Nominal Mix), using 12.5 mm graded aggregate as sub base /paving/hardstanding, complete all as specified and directed.
M&L for 40mm thick plain cement concrete M15(Nominal Mix), using 12.5 mm graded aggregate as paving/hardstanding /floors and pavings finished even and smooth with out using extrs cement etc complete all as specified.
M&L for 100mm thick plain cement concrete M15(Nominal Mix), using 12.5 mm graded aggregate as paving/hardstanding /floors and pavings finished even and smooth with out using extrs cement etc complete all as specified.
Materials and Labour for reinforced cement concrete M-20 Nominal mix in chajjas,beam ,landing and similar suspended work complete all as specified and directed.
Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed
Supply and fix mild steel TMT bars 6 to 8 mm dia., cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed
M&L for use and waste of form work to soffits of suspended slabs such as roof slabs, landings floor slabs and similar work not exceeding 200 mm thick (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of form work to chullah hoods, chajjas,troughs and similar items including edges for fair finished surfaces of concrete, flat, complete all as specified and directed.
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 9 to 10mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,conforming to IS 15622, Grade B II, in riser of steps, skirting, dado and pillar laid over cement screed base including 15 thick rendering Cement mortar (1:3) complete all as specified and directed
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed.
Materials and Labour for, Digital glazed ceramic coloured tiles, 450 X 300 X 7-8mm thick, conforming to IS 15622, Grade B III, on vertical surface of wall such as dados,skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and directed.
M & L for 20 mm thick machine cut granite tiles (any type) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with granite stone shade including 20 mm thick screed in cement mortar 1:4 including grinding and polishing complete all as specified and as directed.
Materials and Labour for rendering 10 mm thick, cement plaster, in cement mortar (1:6) on surface fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Material and labour for rendering 15 mm thick in cement mortar (1:4) on other than fair faces of brick or concrete surfaces (5mm thick CM 1:4 with WPC setting coat and 10mm thick CM 1:4 backing coat),with and including brushing in two layers using water proofing layer of damp proof ultra of make Asain or any other similar material of any approved make (Fosroc/Sika/BASAF) to give a layer of not less than 1.50 mm thick on newly plastered surface complete all as specified and as directed. Note : Water proofing compound and damp roof ultra deemed to be inclusive rates
Materials and Labour for rendering 5mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface finished even and smooth without using extra cement in walls complete all as specified and directed. . Note: - Note : Water proofing compound shall be deemed to be inclusive in Quoated rates
Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces (on ceiling surfaces) in cement mortar 1:3 finished even and fair complete all as specified and as directed.
S & F for glass dividing strips, 38mm wide and 3mm thick, inserted in position to conform to design complete all as specified and directed.
M&L for preparation of old painted surfaces and applying one coat of synthetic enamel paint on steel surfaces of any description not other wise described over 10 cm width or grith etc complete all as specifed and as directed.
M&L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparation of newly plastered surfaces on ceiling and applying three coats of white wash complete all as specified and as directed.
M&L Writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30 cm high complete all as specifed and as directed.
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of white washing on the wall all as specified and directed
M&L for preparing old decorated plastered or unplasterd surfaces of ceiling including cornices, pilasters and other ceiling features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of white washing on the ceiling all as specified and directed
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying two coat of white washing on the wall all as specified and directed
Material and Labour for applying two coats of cement-based paint, white or tinted to new plastered surfaces on walls including priming with alkali resistant priming paint and including preparation of surfaces complete all as specified and directed.
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other ceiling features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one 100 % Acrylic Exterior Emulsion paint (Berger,Weather coat Advanced XP Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brandon on the wall complete all as specified and directed
Material and Labour for complete removal of existing treatment and applying two coats of cement-based paint, white or tinted over and including priming with alkali resistant priming paint to old plastered or unplastered surfaces on walls including preparation of surfaces, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls, and applying two coats acrylic distemper on wall ,over and including with a coat of 2 mm thick white wall care putty premium quality over and including a coat of primer new plastered or unplastered surfaces on wall, complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing/sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat cement base paint on old surfaces complete all as specified.
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing/sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat acrylic distemper on old surfaces complete all as specified Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor) /Nerolac (Beauty)
M&L for complete removal of existing treatment from walls, and applying two coats of acrylic emulsion distemper over a coat of primer on walls,over and including a coat of 1.5 mm thick white wall care putty premium quality on walls complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor) /Nerolac (Beauty)
Supply and Fix,3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sq M in each pane with and including hacking out old broken glass (any thickness, size, quality or description) from frame including providing wooden beads painted with two coat of enamel paint over a coat of primer complete all as specified and directed.
S & F 3mm thick figured Sheet glass pin headed type and glazing with oil putty and pins in square n exc 0.5 sq. m in each pane on wooden/steel joinery with and including hacking out old broken glass (any thickness, size, quality or description) from frame including providing wooden beads painted with two coat of enamel paint over a coat of primer complete all as specified and directed.
M & L Securing glass of any description in existing wooden frames glazed with putty/ beads including removing loose or decayed putty/ beads, spring wire glazing spring clips, painting/oiling one coat on rebates, grooves, reputtying and finally one coat synthetic enemal paint over puttied surface to match existing work (New length of frame reputtied shall be measured) complete all as specified and directed
S & F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F in repair mild steel door spring of rat tail type of size 300 mm, bright finish including roller and roller plate complete all as specified and as directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, fixed to walls incuding mild steel clamp not more than 1metre C/C complete all as specified and directed by Engineer- in- charge .
S & F in repairs PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches/floors complete all as specified and directed by Engineer- in- charge .
S & F UPVC bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC bends with inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S&F in repairs health faucet brass chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall 1.25 m long flexible tube and brass wall hook including making connection and fixed in position complete all as specified & as directed.
S&F in repairs toilet paper holder with flat recessed type stainless steel complete all as specified and directed
S & F 75 mm bore PVC (SWR) branch piece single (Single `Y'/'T') equal or unequal without access door complete all as specified and directed by Engineer- in- charge
S & F 75 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified and directed by Engineer- in- charge
S & F 110 mm bore PVC (SWR) branch piece single (Single `Y'/'T') equal or unequal without access door complete all as specified and directed by Engineer- in- charge
S & F 110 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified and directed by Engineer- in- charge
S & F 75 mm bore PVC (SWR) Vent Cowl complete all as specified and directed by Engineer- in- charge
S & F 110 mm bore PVC (SWR) Vent Cowl complete all as specified and directed by Engineer- in- charge
Preparing surface of sunken slab and applying 15 mm thick cement plaster 1:4 cement sand mortar with integral water proofing compound both on floor and wall. including , laying and testing of elastomeric bituminous coating system based on bituminous emulsion, polymer and additive conforming to ASTM C 836 (“Dr. Fixit Solyseal" or equivalent of M/s Fosroc, M/s STP Limited) over the substrate including application of one coat of primer (solyseal 1 : water 1) followed by two coats of solyseal applied @ 0.90 kg/sqm/coat sandwiched with open woven glass fibre of mesh 2 mm X 2 mm or PE based spun bound fabric of 40 gsm complete as per manufacturer specification in sunken portion with and including sunken floor shall be filled with PCC 1:3:6 as per existing thickness complete all as specified.
S & F flexible (coil shaped) PVC waste pipe for sink and wash basin 32 mm dia with length not less than 900 mm connected to PVC waste fittings complete all as specified and as directed.
S & F rotational moulded polyethylene multi layer water tanks in green colour (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes with and including 20mm Brass ball valves high pressure with polythene float and nut with and including dismantling exsiting unservieable tank one at any height and safety measures complete all as specified and directed.
S & F rotational moulded polyethylene multi layer water tanks in green colour (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes with and including 20mm Brass ball valves high pressure with polythene float and nut with and including dismantling exsiting unservieable tank one at any height and safety measures complete all as specified and directed.
M&L for disconnecting existing tank setting aside for repairs, including cleaning of service PVC tank by rubbing vertical wall and bottom of with bleaching powder and allowed ½ hour to react and then washing down with water to get free from deposits and bleaching inside the tank of capacity and mouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.300 and not exc. 500 ltrs complete all as specified & as directed. Note : Spare part required to be replaced up to Rs 200 deemed to be included in quoated rates.
S&F in repairs PVC tank cover with locking arrangement for 500 ltrs to 1000ltr capacity of approved make complete all as specified & as directed.
S & F in repair 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
Materials and Labour for waterproofing treatment to existing RCC roof in the following steps complete all as specified and directed. (i) Complete removal of the existing water proofing treatment including padding (buid in cm/concrete) and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete (ii) Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area) (iiii) Supply and Laying, chicken wire mesh of size 12.5 mm x 0.51 mm (24 SWG) hexagonal construction including all laps, cutting and waste in fabric reinforcement to PCC roof padding including providing 40 mm thick plain cement concrete (1:2:4) type B0using 12.5 mm graded aggregates as in roof padding. (iv) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (v) Waterproofing treatment over smooth finished surfaces after application of bituminous primer @ 0.40 ltrs per sqm over prepared surfaces of roof including parapet surfaces confirming to IS : 3384 (primer and membrane to be used shall be same manufacturer) prime shall be brand of Shalitex of STP or EmufalTE of M/s Texa Indian Ltd or cold stick bitumen primer of M/s IWL or equivalent make ,(vi) providing and laying APP polymer, modified, non-woven polyester fabric of 150 grams/square metre, reinforced membrane, 3.00 mm thick, weighing 3.60 Kg / Sq M, by torch on application method, with minimum 75 mm overlap on longitudinal direction and 100 mm overlap on the transverse direction and (vii)finally applying with one coat of bituminous based solar reflective aluminium paint @ 125 gms / Sq M or as per manufacturer,s instructions complete all as specified and directed. Make of APP Membrane : M/s STP Ltd./M/s Texsa India Ltd./M/s IWL India Ltd 3. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionand Leak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be submitted. Requisite 10 years guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate.
Materials and Labour for waterproofing treatment to existing RCC roof in the following steps up to 10 mtr height including necessary scalfolding and safety measures complete all as specified and as directed. (i) Complete removal of the existing water proofing treatment and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete (ii) Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc and Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (iii) Applying bituminous primer @ 0.40 ltrs per sqm over prepared surfaces of roof including parapet surfaces confirming to IS : 3384.(primer and membrane to be used shall be same manufacturer) prime shall be brand of Shalitex of STP or EmufalTE of M/s Texa Indian Ltd or cold stick bitumen primer of M/s IWL or equivalent make (iv) One layer of APP based polymeric membranes of approved manufacturers, 3 mm thick, weight not less than 3.6 kg/sqm, reinforced with non woven polyester fabric (weight not less than 160 gms/sqm). Polymeric membrane shall be taken to cover the thickness of slab and shall be finished by a membrane flushing. Note: (v) Laying of APP based membranes shall be done by torch application or as per manufacturer's instructions. (vi) Side overlaps shall be minimum 75 mm and the end taps shall be minimum 100 mm and sealing of all overlaps & joints as per manufacturer instruction. (vii) For parapets, membranes shall be taken to a height of minimum 60 Cm and then inserted to the parapet in a groove. The same shall be finished by a membrane flashing.(viii)finally applying with one coat of bituminous based solar reflective aluminium paint @ 125 gms / Sq M or as per manufacturer,s instructions complete all as specified and directed 3. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionand Leak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be sumitted. Requisite 10 years guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate.
Supplying & fixing to walls , ceiling and laid in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls , ceiling and laid in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Refixing of old steel tubing and connection with new fittings ISI Marked in new or old position (wall, ceiling, floors, etc) of 15 mm bore complete all as specified and as directed.
Refixing of old steel tubing and connection with new fittings ISI Marked in new or old position (wall, ceiling, floors, etc) of 20 mm bore complete all as specified and as directed.
S & F in repairs vitreous china squatting pan, 'Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S” trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs in repairs thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating complete all as specified and as directed.
S & F 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant complete all as specified and as directed.
S & F flexible (coil shaped) PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm connected to PVC waste fittings complete all as specified and as directed.
S & F sinks with drainage board made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers and 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes overall size 915 mm X 460 mm bowel size 410 mm X 330 mm X 160 mm complete all as specified and as directed.
S&F in repair 75mm bore chromium plated shower rose with shower arm of 15mm dia (size of arm 195mm long with bend to 45 degree) complete all as specified and as directed (Make: Jaquar/Marc/Kohler)
S & F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed.
Supply and Fix, in repair corner glass shelf including bracket and railing complete all as specified and directed (Cat No.1173 of Jaquar or Kohler/MARC
Supply and fixing in repairs of Grating doom 100mm dia of PTMT(Minimum weight 25gms) complete including jointing with solvent cement, all as specified & as directed.
S & F in repairs 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S&F in repairs pillar taps 15mm dia, half turn, with capstan heads, chromium plated screwed down high pressure with or without lettered 'Hot' or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified & as directed.
S & F in repairs 15mm bore CP fancy type Angular stop cock complete all as specified and as directed.
S & F in repairs chromium plated with long shank and cup fancy type (Concealed) 15 mm nominal size, Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S & F in repairs 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
Supply and Fix in repairs, brass chromium plated soap dish, ., fixed with brass chromium plated screws, complete all as specified and directed. (Make Jaquar Cat part No. AQN-7731/Marc/Kohler)
S & F 20mm bore Stainless steel drapery rods, suitable for door/widows curtain with incl necessary fancy type Stainless steel dooms as approved by GE, and fitted to each end, with and inclding new brackets and fixed to wall complete all as specified and directed.
S & F Kitchen stainless steel plate rack (24" X 24" X 10") including necessary fixing / fittings & making good the existing surfaces complete all as specified and directed. Make Prayag Cat No P-310 or equivalent as per PS
S & F in repairs flexible (coil shaped) PVC waste pipe for sink and wash basin 40 mm dia with length not less than 700 mm connected to PVC waste fittings complete all as specified and as directed.
S & F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified & as directed.
S & F in repairs 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993, two ways in double control, made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long
S&F in repairs Gun-metal, globe or gate valves for 20mm bore dia of pipe, with iron wheel head, screwed both ends for iron pipe and fixed
S&F in repairs 40mm wide and 5mm thick PVC door seal (snake guard) with powder coated aluminium frame
S & F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S & F in repair 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
RADHESHYAM GUPTA
MS INDIRA ELECTRICS
SHARMA ENTERPRISES
M/s Antara
NATIONAL CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .