OFFICE OF THE EXECUTIVE ENGINEER (E and M) M-1
CHITRA VIHAR BPS LAXMI NAGAR DELHI
Improvement of Electrification System at Geeta colony BPS.
2022_DJB_217198_20
NIT No. 15 (21-22)
Open Tender
Miscellaneous Works
Works
30 days
Geeta colony BPS.
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No 50448339804
₹8,200
16 Mar 2022
22 Feb 2022
1 Mar 2022
22 Feb 2022
1 Mar 2022
22 Feb 2022
90 days
Wiring for light point/fan point/exhaust fan point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size M S.box& earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc as reqd. Group - C.1.8.3
Wiring for circuit / sub main wiring along with earth wire with the following. Sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.2 X 2.5 Sq. mm. + 1 X 2.5 Sq. mm. earth wire.1.14.2
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.1.12
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel MCB distribution board, 415 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator).4 way (4 + 12) Doule Door.2.4.1
Supplying & Fixing 5 amp. to 32 amp. rating 240/415 V, volt miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, Single Pole. 2.10.1
Supplying & Fixing 5 amp. to 32 amp. rating 240/415 V, volt miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, Single Pole & neutral. 2.10.2
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required1.33
S.P. 15/16 amps, one way switch, piano type. ISI marked 31.23.3
6 pin 15/16 & 5/6 amps socket outlet, piano. type ISI marked 31.23.5
Supply of Powder coated Regal Batten type luminaries with electronic ballast of capacity 20W, 1×20 W FTL HF type. Make - Havells/Bajaj/ Polycab
Supply of 1200 mm. Sweep Ceiling Fans. Make :- ( Orient / Havells / Crompton ).
Supply of 600 mm. air circulators Fans. Make :- ( Bajaj / Havells / Crompton ).
Supply of 600 mm. Exhaust Fans . Make :- ( Orient / Havells / Crompton ).
Supply of 2 X 10 Sq. mm. Aluminium Conductor Power Armoured Cable. Havelles/Kalinga/national.
Supply of 70W Led flood light(Polycab,bajaj,Havells,Crompton)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.1.41
Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet coveron the fan box etc. as required. 31.45
Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioningetc. as required. Also for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.1.50.1 & 1.51
HARI ELECTRICAL CO.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .