Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹91.7 LAdmitted-Finance 263 URBAN ESTATE PHASE II BATHINDA | BATHINDA | PUNJAB | 151001 | -5.71% | ₹91.7 L | L1 | Admitted-Finance |
| 2 | L2₹97.0 LAdmitted-Finance D 402 RANJIT AVENUE AMRITSAR | -0.25% | ₹97.0 L | L2 | Admitted-Finance |
Tender Value
₹97.2 L
EMD Value
₹1.9 L
Closing Date
14 Jan 2026, 5:00 pmClosed
Er. Jaspreet Singh Vermi
Executive Engineer Provincial Division Gurdaspur
Construction of New Lecture Hall attached to Mechanical Block in Sardar Beant Singh State University Tehsil and Distt Gurdaspur (Deposit Work)
2026_CEPW_157347_1
Bid No 1 Dated 06.01.2026 BECT
Open Tender
Civil Works - Buildings
180 days
Gurdaspur
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,000
₹1.9 L
Yes
28 Jan 2026
6 Jan 2026
15 Jan 2026
6 Jan 2026
14 Jan 2026
6 Jan 2026
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m.
Providing and applying Anti Termite Treatment using pre constructional chemical treatment measuresasper IS- 6313- 2001(Part 2)& using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution@ 5Litre/Sqm(ii) In there fill earth on both sides of all built up walls 7.5Litre/Running meter(width-300mm,depth- 450mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth with in the outer perimeter @5 Litre solution per Sqm.
Cement Concrete 1:6:12 with stone ballast using mechanical mixer volumetric type.
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Reinforced Cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.ne ballast of size 40mm gauge using concrete mixing volumetric type
Ground Floor
Column
Lintels
First Floor
Column
Lintels
Extra for Ist Floor
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Ground Floor
First Floor
Extra for Ist Floor
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Ground Floor
First Floor
Extra for Ist Floor
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Ground Floor
First Floor
Extra for Ist Floor
First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
Ground Floor
First Floor
Extra for Ist Floor
Sedcond Floor
Extra for IInd Floor
12.5mm thick cement plaster 1:5
Ground Floor
Extra for Ist Floor
20mm thick cement plaster 1:5 in two coats
Ground Floor
Extra for Ist Floor
Washed stone grit plaster on exterior wallsof heightupto10M. aboveground level in two layers, under layer 12.5mm cement plaster1:4(1cement : 4coarse sand ) furrowingcoarse sand : 2stone chipping 10mmnominal size) in panels withgrooveall aroundKgof cement per squaremetre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2the under layerwithscratchingtool,applyingcement slurry on the under layer@2 as per approvedpatternincludingscrubbingand washing, the top layerwithbrushesand water to expose the stone chippings complete as per specification and directionofEngineer-in-charge(Payment for providing grooves shall be made separately).
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including jointing with seal ring (i) Single socketed pipes.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16
Bottom khurra on ground 1.2m 0.6m consisting ofbricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Extra for IInd Floor
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated all lead .
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material
Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material
First Floor
Extra for Ist Floor
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ). Size 600x600 mm
Ground Floor
Extra for Ist Floor
Extra labour for projected nosing of staircase of any shape and design.
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete
Doors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter.
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing thesame in position
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flashwelded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area Float glass panes of 5.5mm thickness
Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventilators complete in all respect
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Ground Floor
First Floor
Extra for Ist Floor
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade
Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications
Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
RECESSED AIR CONDITION SUPPLY TERMINAL POINTS:
Wiring air condition supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases:-
Wiring AC supply terminal points having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
RECESSED COMPUTER SUPPLY TERMINAL POINTS:
Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases:- Accessories
Wiring Computer terminal points having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered), 2Nos. 16/20Amp. switch with indiicator and 2No. blanking plate (Modular accessories).
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:-
Wiring fan point (With fan box)
Wiring light point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
PVC INSULATED FR COPPER CONDUCTOR CABLES:
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1.5sq.mm (Un-sheathed) (For Earthing )
Overall size 2.5sq.mm (Un-sheathed)( For 16 Amp & Computer point )
Overall size 4sq.mm (Un-sheathed) ( For A.C )
Overall size 6sq.mm (Un-sheathed)(For Earthing G.F to F.F Looping )
Overall size 16sq.mm (Un-sheathed) ( From V.D to all T.P.N Box Sub Main )
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part- 1)1988 to be laid (On Surface) as per PWD General Specifications:-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part- 1)1988 to be laid (On Surface) as per PWD General Specifications:-
Overall size 50sq.mm (3½ Core) Un-armoured (On- Surface)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES:
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, MS saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy Gauge PVC Conduit Pipe 32mm dia.(On Surface)
Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed)
COPPER EARTHING:
8 SWG COPPER EARTHING :
Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A- Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation:-
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
BONDING TO EARTH WITH COPPER WIRE:
Bonding to existing earth with copper wire in heavy gauge (1.6mm thick) welded conduit pipe with bends, junction boxes, steel hooks and MS saddle clamps including painting etc:-
Bonding with copper wire 8S.W.G. (4mm dia) in HGW conduit pipe 20mm dia. (on surface)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Triple Pole 50, 63amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve-C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
TP&N Horizontal Double Door Distribution Board 4 way each
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp)
MCCB'S (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (Conforms to IEC:60947-2) having Ics=100%, Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of thimbles etc:-
MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
Supply & Erection of Durable LED Batten with High quality extruded aluminium Housing 40 Watt Input AC Frequency Hz +- 3% complete along with erection of the same with, testing, in all Respect. complete in all respect as per approved /desired by the engineer in charge of work at site . The Certification and Specification of The Led fitting should be as approved by of O/o Advisior( Technical) Govt. of Punjab Letter No: AT/2021/GL/1410-1422 Dated 06-05-2021 Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab.
Supply and erection of BEE 3 star rating AC Ceiling Fan 1200mm (48") Suitable for 230 V single phase with double ball bearing copper wound full aluminium body ,3 no.s blades white in colour .The mounting type is down rod mount .The product should possess a minimum air deleveryof 210 CMM .The rated speed of the product must be minimum of 300 revolution per minute and 5 no.s of speeds .the approximate weight of the product should be 4kg and 189gms without packing or higher .the product should have a manufacturer`s guarantee / warranty of minimum 2 years .the product should be complete in all respects with fan motor blade set doen rod canopy set. shackle kit .twisted wire etc. incluyding erecection & testing of ceiling fans having connection With PVC insulated PVC sheathed two single core copper conductor ( FR ) cable 0.75 sqmm complete in all respects as per satisfaction of the engineer-in charge at site
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.18 MB
Tendernotice_2.pdf
PDF • 2.00 MB
Tendernotice_3.pdf
PDF • 5.87 MB
BOQ_318964.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid