Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L1 | Accepted-AOC Being Rate Reasonable | |
| 2 | L2₹32.4 L+₹2.8 L (9.43%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹34.7 L+₹5.1 L (17.0%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹37.8 L+₹8.1 L (27.3%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹42.0 L+₹12.3 L (41.5%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
8 Sept 2021, 6:00 pmClosed
GE (CENTRAL) KIRKEE
GE (CENTRAL) KIRKEE RANGE HILLS ROAD KIRKEE
REPAIR MAINT OF STAIRCASE AND BUILDING LIGHTS WIRING INCLUDING FITTING AND REPAIR TO METER PANEL ETC OF MD ACCN OF OFFICERS JCOS ORS UNDER AGE EM I IN GE C KIRKEE
2021_MES_467477_1
8497/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (CENTRAL) KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE (CENTRAL) KIRKEE
₹98,000
Yes
7 Oct 2021
12 Aug 2021
9 Sept 2021
12 Aug 2021
8 Sept 2021
27 Aug 2021
12 Aug 2021 - 26 Aug 2021
Amount
M&L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multistranded FRLSH copper conductor cable of size 1.5 sqmm (Nominal Area) drawn in and including PVC caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH copper conductor cable of size 1.5 sqmm as earthlead and connected to earth dolly for one light point for staircase controlled by two 2 way switch, including PVC switchboard of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting celing rose/holders etc including dismantling and taking down old unserviceable point wiring and making good disturbed surfaces complete all as specified and as directed by Engineer in charge.
M&L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multistranded FRLSH copper conductor cable of size 1.5 sqmm (Nominal Area) drawn in and including PVC caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH copper conductor cable of size 1.5 sqmm as earthlead and connected to earth dolly for one light point for staircase controlled by one 1 way switch, including PVC switchboard of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting celing rose/holders etc including dismantling and taking down old unserviceable point wiring and making good disturbed surfaces complete all as specified and as directed by Engineer in charge.
M&L for submain wiring with two single core PVC insulated unsheathed 1100 volt grade multistranded FRLSH copper conductor cable of size 1.5 sqmm (Nominal Area) drawn in and including PVC casing caping/ PVC conduit of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly including dismantling and taking down old unserviceable wiring and making good disturbed surfaces complete all as specified and as directed by Engineer in charge. NOTE:- Two runs of cable with one run of earth wire and one run of casing caping/conduit shall be measured as one length.
Supply and fix in repair switch 6 amps flush type one way single pole complete all as specified and as directed by Engineer in Charge.
Supply and fix in repair switch 6 amps flush type two way single pole complete all as specified and as directed by Engineer in Charge.
Supply and fix in repair Ceiling rose surface bakelite three terminal complete all as specified and as directed by Engineer in Charge.
Supply and fix in repair LED batten fittings, 20 watt, CDL, 230 Volts, 4 feet long, complete with all accessories, internally pre wired and including connecting upto ceiling rose with 0.5mm twin core copper flexible conductor cable including LED lamp and mounting casing box 2 nos complete all as specified and as directed by Engineer in Charge. Make :- HPL, Cat No :- HLPT51820PCGCW or equivalent in Bajaj/Philips/CG/Havells as approved by GE.
Supply and fix in repair LED building security light, 15 Watt, 230 Volt complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, one GI medium grade 20mm bracket of total length 50cm and fixed to wall with 2 nos MS clamp and fastner complete all as specified and as directed by Engineer in Charge. Make :- HPL, Cat No :- HPLLEDSL1560E or equivalent in Bajaj/Philips/CG/Havells as approved by GE.
Supply and fix meter panel floor/mouted on wall, cubical type, compartmentalized, dust and vermin proof, indoor installation IP42 type electrical control panel, including PVC channel 25 x 45 mm, made out of powder coated CRCA sheet of size 700 x 700 x 200 mm (thickness 1.6mm) having an arrangement of fixing the energy meter single phase four number inside the panel and having glass door to take meter reading without open the panel with an arrangementof incoming supply to meter from TPN DB and outgoing supply from meter to distribution board (DB) with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH copper conductor cable of size 6.00 sqmm (nominal area) for phase and neutral crimping with suitable size of lugs/thimble with locking arrangement & one lock including dismantling and taking down old unserviceable meter wooden board and making good to disturbed surfaces complete all as specified and as direcetd by Engineer in charge. Make:- Krutika electricals or equivalent as approved by GE. The Panel shall comprise the following items:-
a) 63 Amp MCCB, 3P with Neutral b) Earth Fault Relay c) Shunt Coil d) Spreader Link e) Busbar/Cable for Outgoing NOTE :- Rate quoted by contractor shall be inclusive of taking down and refixing the existing meter.
Supply and fix meter panel floor/mouted on wall, cubical type, compartmentalized, dust and vermin proof, indoor installation IP42 type electrical control panel, including PVC channel 25 x 45 mm, made out of powder coated CRCA sheet of size 700 x 700 x 200 mm (thickness 1.6mm) having an arrangement of fixing the energy meter single phase six number inside the panel and having glass door to take meter reading without open the panel with an arrangement of incoming supply to meter from TPN DB and outgoing supply from meter to distribution board (DB) with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH copper conductor cable of size 6.00 sqmm (nominal area) for phase and neutral crimping with suitable size of lugs/thimble with locking arrangement & one lock including dismantling and taking down old unserviceable meter wooden board and making good to disturbed surfaces complete all as specified and as direcetd by Engineer in charge. Make:- Krutika electricals or equivalent as approved by GE. The Panel shall comprise the following items:-
a) 63 Amp MCCB, 3P with Neutral b) Earth Fault Relay c) Shunt Coil d) Spreader Link e) Busbar/Cable for Outgoing NOTE :- Rate quoted by contractor shall be inclusive of taking down and refixing the existing meter.
Supply and fix meter panel floor/mouted on wall, cubical type, compartmentalized, dust and vermin proof, indoor installation IP42 type electrical control panel, including PVC channel 25 x 45 mm, made out of powder coated CRCA sheet of size 700 x 700 x 200 mm (thickness 1.6mm) having an arrangement of fixing the energy meter single phase eight number inside the panel and having glass door to take meter reading without open the panel with an arrangement of incoming supply to meter from TPN DB and outgoing supply from meter to distribution board (DB) with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH copper conductor cable of size 6.00 sqmm (nominal area) for phase and neutral crimping with suitable size of lugs/thimble with locking arrangement & one lock including dismantling and taking down old unserviceable meter wooden board and making good to disturbed surfaces complete all as specified and as direcetd by Engineer in charge. Make:- Krutika electricals or equivalent as approved by GE. The Panel shall comprise the following items:-
a) 63 Amp MCCB, 3P with Neutral b) Earth Fault Relay c) Shunt Coil d) Spreader Link e) Busbar/Cable for Outgoing NOTE :- Rate quoted by contractor shall be inclusive of taking down and refixing the existing meter.
Supply and fix Earth Fault panel synchronizing with existing panel complete all as specified and as directed by Engineer in charge, comprises of the following items:-
a) 63 Amp MCCB, 3P with Neutral b) Earth Fault Relay c) Shunt Coil d) Spreader Link e) Busbar/Cable for Outgoing f) Enclosure 300 x 400 x 250mm (1/1.2mm thick) NOTE :- Rate quoted by contractor shall be inclusive of taking down and refixing the existing meter.
Supply and fix in repair Distribution board, TPN 4 way, 415 volts with provision for FP MCB/isolator as incomer and SP/TP MCB as outgoing and electrically connecting up and making good to the disturbed surface complete all as specified and as directed by Engineer in charge. Make:- Legrand or equivalent from List of make as approved by GE.
Supply and fix in repair MCB, amp rating 240V,10 KA, 'C' curve of SP 6 to 32 Amp current carrying capacity in the MCB DB complete with connecting , testing and comissioning and making good to the disturbed surface complete all as specified and as directed by Engineer in charge. Make:- Legrand or equivalent from List of make as approved by GE.
Supply and fix in repair MCB, amp rating 415V,10 KA, 'C' curve of FP 63 Amp current carrying capacity in the MCB DB complete with connecting , testing and comissioning and making good to the disturbed surface complete all as specified and as directed by Engineer in charge. Make:- Legrand or equivalent from List of make as approved by GE.
Material and Labour for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metre long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300mm dia and 3 meter long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 25x4 mm all as shown in Plate no 2, connected to the earthing test point, concrete pit in PCC 1:3:6 Type C2 with pit cover, funnel, wiremesh, 32mm dia light grade GI tubing for protection of GI strip 25x4 mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in and removal complete all as specified and as indicated in SSR Part I, including testingto achieve earth resistance value as per IS specifications complete all as specified and as directed by Engineer in Charge.
Mahindra Electric Stores
Om Construction
M/S. Niksun Electro-Infra Private Limited
metro electrical services
PAMS ENTERPRISES
M/S PREETAM KUMAR SHIVAJI SHINDE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .