Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.3 L+₹4.1 L (17.4%)Rejected-AOC 183 4 J K COLONY JAYMALU KANPUR NAGAR | L2 | Rejected-AOC L2 | |
| 3 | L3₹28.0 L+₹4.7 L (20.2%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹29.3 L+₹6.0 L (25.8%)Rejected-AOC B T F 1203 BETWA APARTMENT GOMATI NAGAR BISTAR LUCKNOW | LUCKNOW | UTTAR PRADESH | 226001 | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹3 L
Closing Date
12 Dec 2024, 2:00 pmClosed
ARUN KUMAR
TUBEWELL INVESTIGATION AND PLANNING UNIT 3 LUCKNOW
Repair and Renovation of Suprintending Engineer Office,Tubewell Investigation and planning circle,Lucknow (Construction of Boundary wall,Cycle or motor cycle stand shed,Interlocking and store Room etc)
2024_UPIDM_973408_1
TE-02/2024-25
Open Tender
Civil Works - Buildings
Item Rate
TUBEWELL INVESTIGATION AND PLANNING CIRCLE LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹854
₹3 L
1 Jan 2025
22 Nov 2024
13 Dec 2024
22 Nov 2024
12 Dec 2024
22 Nov 2024
Amount
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil 0.30 m & Avobe
Filling of carted earth.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position specfied grade of reinforcement cement concrete, excluding the cost of centering,shuttering,finishing & reinforcement. 1:1.5:3 (1 cement,1.2 coarse sand zone-iii,3 graded stone aggregate 20mm. (Nominal size)
Centering,shuttering inluding strutting,proping etc. & removal of form for Foundations, footings, bases of columns, etc. for mass concrete.
Steel reinforcment for r.c.c. work including strainghtening cutting bending placing in position & binding all complete.Thermo machanically treated bars of grade Fe-500D or more.
Brick work with common burnt clay (non-modular) bricks of class -150 in foundation and plinth beam Cement mortar 1:6 ( 1 Cement :6 Coarse sand)
Brick work with common burnt clay (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm Cement plaster on rough side of single or half brick wall of mix 1:6 ( 1 cement :6 coarse sand)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. Plain wing adjustable ridges
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 1.0 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. omplete. 40 mm thick with 20 mm nominal size stone aggregate
Providing and fixing glass strips of 5.5 mm thick in joints of floors and skirtings at the time of laying floors flush with floor level including all materials labour, Tools & Plants etc. complete. .
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
Half brick masonry with common burnt clay (non modular) bricks of class 150 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Class 150 brick work in 1:4 cement and corse sand of 2.25 fineness modulus mortar in foundation and plinth including supply of all materials, labour and tools and plants etc. required for proper completion of the work.
Providing and laying 80mm thick interlocking cement concrete tiles ( 30 mpa) including levelling and dressing of surface to required level and slope filling joint with local sand including the cost of labour ,material and T&P required for proper compition of work as directed by engineer incharge.
Providing and Applying Plaster of Paris Puttey over Plastered surface of surface to prepare of surface even and smooth
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work ( Two or more coats ) over and including water thinnable priming coat with cement primer.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed pvc conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed pvc conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2X 1.5sq. mm + 1 X 1.5 sq. mm earth wire
2X4 sq. mm + 1X4 sq. mm earth wire
Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required.
4 Module
6 module
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 WAY TPN
Supply and fixing of 240 volts "L" series miniature circuit breaker 6 amp to 32 amp. (10 KA) IN EXISTING MCB , DB complete with connections as required. 6-32 amps.
Supply fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer -in-charge. 40 Amp. 4P MCB (10KA)
S/F of LED tube light with batten suitable for up to 1X22 watt LED tube light fitting including tube on suraface complete in all respect. CAT-AAA
Supply fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelover a cushionof 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge,complete in allrespect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc
Supply and fixing of brass nickleplated compressiongland for PVC insulated& armoured served sheathed, undergroundcable including rubber ring etc. complete in all respect. The armouringof the cable shall be properly connected with the earth as per direction of Engineer-Incharge.
M/s Parvez Trading Co. (BID ID -4779121)
TRUWAY ENTERPRISES (BID ID -4782684)
Delight Construction (BID ID -4782883)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .