| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹15.1 L+₹2.0 L (14.8%)Rejected-Finance | L2 | Rejected-Finance HIGHER BID | |
| 3 | L3₹15.5 L+₹2.4 L (18.0%)Rejected-Finance | L3 | Rejected-Finance HIGHER BID | |
| 4 | L4₹15.8 L+₹2.6 L (20.0%)Rejected-Finance SUMEL BAMANWAS SWAI MADHOPUR | L4 | Rejected-Finance HIGHER BID | |
| 5 | L5₹20.8 L+₹7.6 L (57.6%)Rejected-Finance | L5 | Rejected-Finance HIGHER BID |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
1 Dec 2020, 6:00 pmClosed
GE WEST FEROZEPUR CANTT
GE WEST FEROZEPUR CANTT
SPL REPAIR TO EXISTING SEWAGE LINE AND MANHOLES FROM SEWAGE PUMP NO 10 TO SEWAGE PUMP NO 11 UNDER GE WEST FEROZEPUR CANTT
2020_MES_390004_1
802020/GE-63/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST FEROZEPUR CANTT
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE WEST FEROZEPUR CANTT
₹26,000
Yes
6 Feb 2021
11 Nov 2020
3 Dec 2020
11 Nov 2020
1 Dec 2020
25 Nov 2020
Amount
Cleaning of existing manhole of any size including removing & re-covering of RCC/CI cover of depth not exc 1.5 mtr by bailing out water/sewage by mechanical pump or manually including mouth of sewage line and removing the deposited residual sludge/debries to a distance not exc. 50 mtr and buried in the ground complete including cleaning sewage line by rodding manhole to manhole complete all as diercted.
Cleaning of existing manhole of any size including removing & re-covering of RCC/CI cover of depth exc 1.5 but n. exc 3.00 mtr by bailing out water/sewage by mechanical pump or manually including mouth of sewage line and removing the deposited residual sludge/debries to a distance not exc. 50 mtr and buried in the ground complete including cleaning sewage line by rodding manhole to manhole complete all as diercted.
Taking down cement plaster from inside/outside of existing septic tank/manhole/walls etc including racking out joints, hacking for key scrubbing down with water and removal of rubbish off the premises complete all as directed.
M and L for 15 mm thick rendering in cement mortar 1:4 inside and outside wall of manhole of brick work/ concrete surface and finishing even and smooth without using extra cement mortar as per manufactures instructions complete all as specified & as direcetd. Note: (i) WPC shall be measured and paid for separately as 'Supply only'. (ii) WPC to be mixed @200ml per 50 Kg bag of cement all as manufacturers instruction.
Rendering/plastering, 10mm thick in cement mortar (1:4) on concrete surfaces, surfaces finished even and smooth without using extra cement complete all as specified.
Supply only integral water proofing compound complete all as directed.
Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC1:2:4 type B1, smooth finished and reforming benching as required for internal pipe of dia 450 mm complete all as directed.
Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia 450 mm complete all as directed.
M & L for hardcore of gauge not exc 63mm graded stone aggregates, deposited, spread and levelled in layers not exc.15 cm thick including watered and rammed to a true surface.
M & L for PCC 1:3:6 type C2, (using 40 mm graded aggragate) as in concrete bed to 450 mm bore drain pipe including packing under and hunching against the sides of pipes after pipe laid and tested complete all as directed.
M & L 75 mm thick PCC 1:4:8 type D-2 (using 40mm gd stone agg) as in sub base all as specified.
M&L 40mm thick PCC(1:2:4) type B-1 using 20mm graded stone aggregate as in floor and finished the concrete surface even and smooth without using extra cement.
M & L for 450 mm bore reinforced concrete pipes,Class NP-3 , laid and jointed complte with collars including rubber ring joints complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and raming earth or broken rubble mieed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in soft/loose soil.
Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5 mtr depth for cesspits, manholes etc. and getting out soft/loose soil even in foul position complete aii as specified and as direcetd.
Excavation in trenches not exc. 1.5 mtr wide and exc. 1.5 mtr but n.exc. 3.00 mtr depth for cesspits, manholes etc. and getting out soft/loose soil even in foul position complete aii as specified and as direcetd.
Returning, filling including spreading leveling watering and well ramming in layers n. exc 25 cm in soft/loose soil complete all as directed.
Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as directed.
Dismantling brickwork of stone/boulder masonry, build incement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Material and labour for brick work with sub class 'B' brick straight curved on plan exceeding 6 metre mean radius with old size bricks built in CM 1:6 for cracked wall of manholes,septic tank, soak pits etc ad all other similar works complete all as specified and directed.
All as per item No-15 here-in -above but except bricks complete all as specified and directed. Note :- Old serivceable bricks obtained from Srl No 14 shall be reused after proper cleaning.
Providing cement concrete type B1 1:2:4 (20 mm graded aggregate) as in copings to brick wall, kneelers,bedplates and all other similar works including necessary form work complete all as specified and directed.
Demolition of cement cocrete (unreinforced) not exceeding 15 cm thickness (above or below ground level) complete all as directed.
M&L for PCC (1:3:6), type C2 (40 mm graded aggregate ) in foundation filling and mass concrete for bottom of manhole complete all as specified and directed.
M&L for PCC (1:4:8), type C2 (40 mm graded aggregate ) in foundation filling and mass concrete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.
Demoletion of reinforced cement concrete (reinforcement cut as required to facilitate demoletionof any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for RCC(1:2:4), type B1 (using 20 mm graded stone aggregate) cement concrete cover slab for manhole and similar article with plain face, including necessary form work complete all as specified and direceted.
S&F deformed or twisted TMT bars 8 mm dia cut to length bent to shape required including cranking binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
Cleaning of sewage pipe lines of dia exc 100mm and not exc. 250mm systematically by passing/rodding ropes,knots,bamboo/wire/kandi, rotary cleaning rods complete all as specified and directed.
S&F of rolled mild steel as in roof trusses, ( framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing ( Beam, tee,angle,channel or flat sections ) including distance pieces , cleats etc. conforming to Fe-410-W (Gde E-250) quality A.
Rolled mild steel plates (plain or chequrred) channels, Square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed.
S&F Mild steel hollow section of (Fe-410-W(Gde-E-250 quality-B) as in rafters , pillars and purlin where connected to common rafters incl for cutting to dead length where required , notching ,drilling fitting , riveting and welding. providing and fitting angle cleats ,gusset plates etc also for welding ,plumbing truing up and ad fixing complete all as specified and as directed.
Mild steel Screw bolts (machine made) with hexagonal or square heads at one end screwed the other or screwed both ends, each screwed end to be fitted with washers and one hxagonal or square nut not exceeding 5cm long but not exceeding 10cm long diameter of neck in 11 to 15mm dia complete all as specified and as directed.
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over primed steel surfaces complete all as specified.
S&F Pre painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed.
All as per item NO:29, but 0.80mm thick plain sheet in ridges hips, valley gutters drip and straight flashings (length and girth as fixed) with grade of Zinc coating 275 all as specified and directed.
Plain cement concrete (1:2:4), type B-0 using 12.5mm graded stone aggregate as in , kerbs, mud stop, rounded or chamfered on edges including form work complete all as specified and directed.
S & F in rep of Gypsum Board 8 to 9 mm thick in ceiling fixed with screw 60x60cm placed in ceiling (Angle 25mm X 25mm , Main tee 38mmX23mm ,Sub tee 23mmX23mm) incl aluminium anodised/powder coated snap grid frame 605X605 mm for false ceiling incl hanging arrangement complete all as specified and directed by Engineer in Charge. Note:-The hanging stay wire/rod shall not be less than 4.00mm thick all are included in the above mentioned item only.
S & F in repair to Hollow PVC wall lining consisting of 5mm thick single side prelam PVC sheet instead of plain colour sheet inclusive of solvent cement and fixing on PVC frame as per specified in MES schedule part-I & II complete all as specified and directed by Engineer in Charge .
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over primed steel surfaces complete all as specified.
M&L Preparing surfaces plastered or unplastered on walls apply two coats of oil Bound distemper over a coat of primer after finisishing wall surface with Birla/JK wall care putty
M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35Grade including laying of sand cushioning, etc, complete all as specified and as directed. Note :- Sand will be measured zand paid seperately
Sand filling under floors or in foundations including watering and consolidation
Taking down carefully copper /aluminium point wiring (light, fan , socket or power ) complete, fittings such as switches, ceiling roses, pendants, regulators sockets light fitting etc removing materials to store for keetping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls , floors ,etc.
M&L point wiring complete with 1100 volts grade PVC insulated unsheathed FRLS cable of copper conductor multi stranded of size 1.5 Sqmm, single core, in and including rigid non metallic PVC conealed conduit, medium grade of suitable size (not less than 20 mm dia) duly ISI marked with all accessories such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards/round blocks (for housing lamp holders and sketch fittings etc) and new MS pressed steel/cast iron sunken boxes of suitable size for mounting switches/bell pushes/sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continous earth wire of size 1.5 Sqmm unsheated stranded copper conductor with green PVC insulation connected to common earth dolly complete all as specified and directed for the following:- One light point/fan point/bell point controlled by one single pole one way switch
One 5 Amps socket outlet independent controlled by one single pole 5 Amps switch
One 5 Amps socket outlet same board controlled by one single poles 5 Amps switch
All as per item No -38 above but One 15 Amps socket outlet controlled by one 15 Amps suitable wiring with 4.00 Sqmm PVC insulated, unsheathed FRLS cable of multistranded copper conductor with continuous earth wire of size 2.5 Sqmm PVC insulated FRLS, unsheathed,multistranded copper conductor cable all as specified and directed.
S&F switch paino flush type 5 Amps, one way duly ISI marked.
S & F Switch piano flush type 15 amps, one way ISI marked.
S & F Socket outlet 5 pin, 5 Amps, piano flush type duly ISI marked
S & F Socket outlet, 2 in one 6 pin 5 and 15 Amps piano flush type ISI marked.
Supply & Fixing step type regulator Piano switch type ( 5 step) for ceiling fan 1200/1400 mm size 230 volts, 6 Amps.
Supply & Fix in repair sheet metal enclouser SPN DB's 8 way double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series, 240 volts 200 Amps rated enameled bus bar 8 way dust and vermin proof ssuitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified.
MCB single pole neutral(SPN) 240 volts, 40 Amps, 10 KA complete all as specified.
MCB single pole(SP) 240 volts, 06 to 32 Amps, 10 KA complete all as specified.
S&F LED Ceiling Light 36 Watt 600x600 mm 240 volts, energy saving complete with all caeessories including diriver, coneection up to the light fitting all as specified and directed. LCTLRN-36FO-CDL of crompton or equivalent.
Kansal Enterprises
Ms Hari Singh
GS and Co
JAWAHAR CONSTRUCTION COMPANY
M/s Surjit Singh and bros
KAILASH CONSTRUCTION COMPANY
CHETAK CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .