| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC 63 PILKHANA ROAD BERHAMPORE MURSHIDABAD 742101 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹32.4 L+₹8,800 (0.27%)Rejected-Finance 334 SCHOOL DANGA BANKURA BANKURA WEST BENGAL 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹32.5 L+₹13,784 (0.43%)Rejected-Finance 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹64,705
Closing Date
4 Jul 2022, 12:30 pmClosed
EE/BED/PWDTE
PWD Compound, Kenduadihi, Near Bhairabsthan,Bankura-722102
Supply, Installation, Testing and Commissioning of Fire Alarm and Detection System at Kotulpur HitaSadhan Pathagar, P.O- Kotulpur, Pin-722141,Under Kotulpur Block
2022_WBPWD_385433_1
WBPWDTE/EE/BED/NIQ_23/Q of 2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Wise
45 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹64,705
22 Nov 2022
15 Jun 2022
7 Jul 2022
15 Jun 2022
4 Jul 2022
15 Jun 2022
Amount
Supply , installation , testing and commissioning of Microprocessor based addressable type fire alarm control panel.The Fire Alarm Panel shall have single loop and relay controls. The PANEL shall be able to generate History Events. The panel should be capable to acknowledge, singnal silence and reset function of event. The Panel shall have provision for Modbus/Bacnet/Lanworks.(Approved Makes : Mircom/GST/Secutron/Simens Cerbus Pro/Securiton/Bosch).
Supply , installation , testing and commissioning of Addressable smoke detector with base .(Approved Makes : Mircom/GST/Secutron/Simens Cerbus Pro/Securiton/Bosch).
Supply , installation , testing and commissioning of Addressable Manual call point for manual Fire signaling (Approved Makes : Mircom/GST/Secutron/Simens Cerbus Pro/Securiton/Bosch).
Supply , installation , testing and commissioning of Addressable Combined Sounder and Strobe with programmable alarm tones and with require modules. (Approved Makes : Mircom/GST/Secutron/Simens Cerbus Pro/Securiton/Bosch).
Supply , installation , testing and commissioning of Loop Isolator Module for SLC line protection from loop line short circuit and any serge pass (Approved Makes : Mircom/GST/Secutron/Simens Cerbus Pro/Securiton/Bosch).
Supply and Laying of 2Cx 1.5 Sq. mm Twisted copper FRLS , Cable fixed on the surface/through conduit of the building structure complete with termination and testing as per requirement. Approve Make : POLYCAB/HEMFLEX/MESCAB/KEI.
Supply and Laying of 25 mm PVC conduits in following sizes including cost of junction boxes, bends, elbows sockets, tees etc. laying in slab, cutting chases and making good or surface mounted including all fixing hardware. Approve Make : AKG/Norpac/Primco Plast/BEC/ or any ISI.
Supply and installation of 6 Kg ABC type Fire extinguisher ISI brand Flamen/Fyrex/Safex/One Top.
Supply and installation of Fire extinguishing Ball with Mount Make AFO/Fyrex/Cease Fire.
Supply, Installtion, Testing & Commissiong of 2 way Indoor/Outdoor type wall mount Loudspeaker for Fire Emergency Voice Evacuation System: Frequency range (-10dB) of 65Hz to 20kHz; Power handling of 200Watt peak; Nominal dispersion of 120H X 120V; Sensitivity of 86 dB SPL and Max SPL of 110 dB SPL peak; Nominal Impedance 8 Ohms; Integral multi-tap Transformer with tap settings of 12/25/50W @ 100V or better. with Powder-coated magnetic steel grill; U Brackets with pitch adjustment shall be included. Shall be rated for Outdoor IP55 rated as per IEC529.Approve Make :EAW/Mayer Sound /Bose
Supply, Installtion, Testing & Commissiong Class D amplifier for Fire Emergency Voice Evacuation System with Dual Channels of Load independent 1000W outputs, LZ or HZ or mixed use operation; Frequency Response : 20Hz - 20kHz for LZ mode; Dynamic range> 100dBA and THD <0.04% at rated output complete with standard accessories as required. Phoenix input and output connector. .Approve Make :Powersoft/Bose/Labgruppen
Supply, Installtion, Testing & Commissioning of wireless handheld microphone with Diversity receiver (UHF) for Fire Emergency Voice Evacuation System with12 Channel Preset or better , Display on Transmitter and Receiver , RF Power output 30mW or Better , Polar Pattern :- Cardiod/Supercardioid or better , Carrier frequency range 500Mhz to 865Mhz , Frequency response 20Hz to 20Khz , Mute Button on Transmitter , Battery Operation time Minimum 8hr , Should have Charging Contact in Transmitter , Receiver, switching bandwidth Minimum 40Mhz Or better, Complete Set complete as required as per tender specifications. Approved Makes: Beyerdynamic /Televic /Sennheiser
Supply, Installtion, Testing & Commissiong digital stereo mixer for Fire Emergency Voice Evacuation System with Eight high-quality audio preamps with XLR-combo jacks for microphones or instruments, and switchable phantom power ,Two Aux inputs for additional sources, four Aux sends, Balanced ¼” TRS and XLR stereo outputs, USB-A and -B for USB drive playback or PC/Mac interfacing, Independent headphone output.Approved Make: Midas/Allen & Heath/Bose
Supply, Installtion, Testing & Commissiong Floor mount Rack 8U 600mm x 800mm with fan 2Nos,Tray- 03 Nos. 5/15 Amp power mangement 2 Nos.Lockable front and back door
Supply, Installtion, Testing & Commissiong80 0.20 mm x 2 Core ATC Copper cable.Approve Make :Belden/Krystal/Krammer
Swarnendu Sarkar
TAPAN KUMAR SARKAR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .