Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.8 CrAccepted-AOC | ₹1.8 Cr Quoted ₹2.0 Cr | L-1 | Accepted-AOC L-1 Bidder. |
| 2 | L-2₹2.2 Cr+₹16.7 L (8.26%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | ₹2.2 Cr+₹16.7 L (8.26%) | L-2 | Rejected-Finance Rejected. Other Than L-1. |
| 3 | L-3₹2.2 Cr+₹16.9 L (8.36%)Rejected-Finance AMLA TOLA DISTT KATIHAR BIHAR 854105 | KATIHAR | BIHAR | 854105 | ₹2.2 Cr+₹16.9 L (8.36%) | L-3 | Rejected-Finance Rejected. Other Than L-1. |
| 4 | L-4₹2.2 Cr+₹20.6 L (10.2%)Rejected-Finance SAHEBPARA RAOD UPPER BAGDOGRA P O BAGDOGRA DISTRICT DARJEELING WEST BENGAL PIN 734014 | BAGDOGRA | DARJEELING | WEST BENGAL | 734014 | ₹2.2 Cr+₹20.6 L (10.2%) | L-4 | Rejected-Finance Rejected. Other Than L-1. |
| 5 | L-5₹2.2 Cr+₹20.9 L (10.4%)Rejected-Finance C O BLUE STAR MEDICAL HALL BAGDOGRA DIST DARJEELING WB | BAGDOGRA | DARJEELING | WEST BENGAL | ₹2.2 Cr+₹20.9 L (10.4%) | L-5 | Rejected-Finance Rejected. Other Than L-1. |
Tender Value
₹2.9 Cr
EMD Value
₹3.6 L
Closing Date
1 Jul 2023, 6:00 pmClosed
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734 008 (WB)
SPECIAL REPAIR TO STORAGE SHEDS AT BENGDUBI MIL STATION UNDER GE BENGDUBI
2023_MES_600968_1
98774/BENG/SZ/E8
Open Tender
Civil Works
Item Rate
365 days
BENGDUBI
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE BENGDUBI
₹3.6 L
HQ CE SILIGURI ZONE
26 Jul 2023
3 Jun 2023
8 Jul 2023
3 Jun 2023
1 Jul 2023
24 Jun 2023
3 Jun 2023 - 12 Jun 2023
14 Jun 2023
Amount
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, hips, valley gutter complete all as specified and directed.
S&F Pre- painted colored trepezoidal profiled galvalume/Zincalume sheet with minimum 50mm TCT confirming to IS-513(AZ-150 GSM, Al Zn alloy metalic coating , 550 MPA yield stress as per AS-1397), colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer, as in roof covering, cladding to wall , fixed with and including galvanised self drilling self tapping fastener(12-14x55 with EPDM Seals), complete all as specified and directed.
S&F Pre- painted colored plain sheet profiled galvalume/ Zincalume sheet with minimum 50mm TCT confirming to IS-513(AZ-150 GSM, Al Zn alloy metalic coating , 550 MPA yield stress as per AS-1397), colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer, as in roof covering, cladding to wall , fixed with and including galvanised self drilling self tapping fastener(12-14x55 with EPDM Seals), complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S& F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe -410-W(Gde-E-250) quality-A complete all as specified and directed.
M&L for two coats of synthetic enamel paint over one coat of red oxide primer on new steel surfaces of any description over 10cm in width or girth including preparation of surfaces complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to FE-410W(Gde E-250) Quality-B complete all as specified and directed.
S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to FE-410W(Gde E-250) Quality-B complete all as specified and directed.
S&F 1.00mm thick Mild steel, plain, black steel sheets in available sizes for steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
S & F 1.00mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
S & F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
S & F Ball bearing for rolling shutters complete all as specified and directed.
M& L for PCC 1:2:4 Type B1(using 20mm graded crushed stone aggregate) as in filling and mass concrete complete all as specified and directed.
Demolition Cement Concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) and removing debris from site of work complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4 type B2 (using 12.5mm graded crushed stone aggregate) as in flooring making surface even and smooth without using extra cement complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 20mm graded crushed stone aggregate) as in plinth protection finished even and smooth using extra cement.Joints to be given every 3m interval and corners of buildings and fitted with biyuminious mastic or equivalent filler complete all as specified and directed.
Supply only polyester triangular fibres as secondary reinforcement in all types of concrete and mortars complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls, etc. Incl raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces mixed with water proofing compound as per manufacturer’s instructions and finishing the surfaces fair and even without using extra cement complete as specified and directed. NOTE : WPC shall be measured and paid separately as ‘Supply only’ against appropriate item of this schedule.
Supply only liquid water proofing compound complete all as specified and directed.
M&L rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed.
M&L preparation of new plastered surfaces of wall, etc and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for complete removal of old existing treament and preparation of surface by washing, rubbing down and stopping of distempered and painted surfaces and applying two coat of cement based paint (any tint) over a coat of alkali resistant primer on walls complete all as specified and directed.
M&L for preparation of old plastered / un-plastered surface by complete removal of existing treatment and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surface and applying three coats of white wash complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets and frame work complete all as specified and directed.
M & L for Anodised aluminium snap grid (SIZE-605x605MM)frame work for false ceiling complete all as specified and directed.
S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/ GI/ Aluminium frame work with screws as in ceiling flat or sloping complete all as specified and directed.
M&L for preaparation of new surface and apply two coats of oil bound distemer over a coat of primer on ceiling complete all as specified and directed.
Making good for wall top for roof sheet or under cills or over arches, lintels and bressummers including all pinning when necessary with cement mortar (1:6)complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and directed.
S&F Pressed Steel frames for doors of size 125x60mm with one or more rebates for double shutter including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and directed.
M & L for PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in copping, holdfast and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
S&F Steel window with side shutter including projecting type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded complete all as specified and directed.
All as per Srl Item No. 38 above but without glazing bar complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges steel peg stay complete all as specified and directed.
S&F for window guard bars let in and fixed independently in wooden frames confirming to Fe 290 Gde E-165 complete all as specified and directed.
S & F 30mm Plain, framed, factory made panelled shutters made of 2nd Class HW (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers fitted to chowkats complete all as specified and directed.
M&L for two coats of synthetic enamel paint over one coat of pink primer on new wooden surfaces of any description over 10cm in width or girth including preparation of surfaces complete all as specified and directed.
S&F 3.00 mm thick sheet glass of ordinary quality and glazing with oil putty or rubber gasket steel frame in squares n exc 0.50 sqm in each pane complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
S&F Galvanised steel wire cloth. 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F 100 mm mild steel butt hinges, medium weight, cold rolled, complete all as specified and directed.
S&F Aluminium handles, 150 mm size, cast type anodized complete all as specified and directed.
S&F Aluminium anodised barrel tower bolts, 200mm long, of extruded section complete all as specified and directed.
S&F Aluminium alloy anodised sliding door bolts, of 250 mm long with hasp, staple (bolt type) fixing clips of sheet cast or extruded section, fixing bolts and sliding bolts of extruded section complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with flyash bricks old size built in CM (1:6) straight or curved on plan exceeding 6 m mean radius complete all as specified and directed.
M&L for old size brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4) complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work and rendering is to be finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface of walls, floors etc as per existing specification complete all as specified and directed.
M & L for point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including in PVC conduit of suitable size with all necessary fittings, terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto size of 200 x 300mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of switches, sockets, fan regulators etc complete all as specified and directed. for the following : - NOTE : For concealed wiring Cutting Chases shall be paid separately. Item Continued as 58.00 to 60.00.
One light point/one fan point controlled by one switch
One 3 pin socket outlet, 5 Amp independent
One 3 pin socket outlet, 5 Amp on the same board with other switches
M & L for point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 2.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 2.5 sqmm size through and including in PVC conduit of suitable size with all necessary fittings, terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of one 15 Amp switches-sockets outlet independent complete all as specified and directed. NOTE : For concealed wiring Cutting Chases shall be paid separately.
S&F in replacement switch socket combination multipurpose 3 pin 15 amp flush type complete all as specified and directed.
S & F in replacement Switch piano, flush type single pole, one way 6 Amp complete all as specified and directed.
S & F in replacement Socket outlet 2 in 1, 3 pin, 6 Amp complete all as specified and directed.
S & F in replacement Switch socket combination 2 in 1, 6 Amp flush type complete all as specified and directed.
S & F in replacement Ceiling rose, 3 way PVC insulated body complete all as specified and directed.
S&F fan regulator electronic deluxe rotary step type complete all as specified and directed.
S & F LED Tube Light luminaries with high performance LED with driver 1 x 40W(4 Feet long, Cool day), 230 volt, 50 Hz with aluminium housing & integrates electronic driver and necessary electric connection to ceiling rose and clamps for fixing on wall/ceiling/beem etc. complete all as specified and directed.
S&F LED down light 50 watt 230 V AC, 50 Hz, IP-65 system efficacy 125 lm/W to 130 lm/W energy saving, PDC housing with impact and corrosion resistant suitable for ceiling (surface/ suspended) mount and necessary electric connection to ceiling rose and clamps for fixing on wall/beem/ceiling complete all as per specified and directed.
S & F in repair Building security LED light luminaire fitting 1X25 W 230 V AC, 50 Hz, IP-66 energy saving with thermal anagement, and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt, nut,washer,clamp made out of MS flat of size 25X3 mm , 4 nos Anchor Bolt of suitable size etc complete all as specified and directed.
Refixing the serviceable LED battern 18 to 20 watt light fitting from including necessary clamps, electrical connection etc. complete all as specified and directed. NOTE : Serviceable light fitting obtain from Item No. 56 shall be reused.
Taking down of Old MCB DB / control box/changeover switch any type any size including MCBs and separating the serviceable MCB DBs and MCBs for reuse at site complete all as specified and directed.
S & F Sheet metal enclosure for MCB DB double door Triple pole & Neutral 8 way with common bus bar at incomming end complete all as specified and directed.
S & F Sheet metal enclosure for MCB DB double door Triple pole & Neutral 6 way with common bus bar at incomming end complete all as specified and directed.
S & F Sheet metal enclosure for MCB DB double door Triple pole & Neutral 4 way with common bus bar at incomming end complete all as specified and directed.
S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 12 way with common bus bar at incomming end complete all as specified and directed.
S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with common bus bar at incomming end complete all as specified and directed.
S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 4 way with common bus bar at incomming end complete all as specified and directed.
S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 2 way with common bus bar at incomming end complete all as specified and directed.
S & F 415V 10KA 'C' curve miniature circuit breaker (MCB) of capacity 40 to 100 Amps, TPN in the DB complete with connection and testing complete all as specified and directed.
S & F 415V 10KA 'C' curve miniature circuit breaker (MCB) of capacity TPN, 16 to 30 Amps in the DB complete with connection and testing complete all as specified and directed.
S & F 240V, 10KA 'C' curve miniature circuit breaker (MCB) of capacity SPN 40 to 63 Amps in the MCB DB complete with connection and testing complete all as specified and directed.
S & F 240V, 10KA 'C' curve miniature circuit breaker (MCB) of capacity SPN 6 to 32 Amps in the MCB DB complete with connection and testing complete all as specified and directed.
S & F 240V, 10KA 'C' curve miniature circuit breaker (MCB) of capacity SP 6 to 32 Amps in the MCB DB complete with connection and testing complete all as specified and directed.
Cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exceeding 10 cm girth and pointing in cement morter (1:3) complete all as specified and directed.
Taking down of Old Submain Wiring any type any size including Conduit complete all as specified and directed.
M & L for sub main wiring with 4 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm 1100 Volt alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm 1100 Volt as earth continuity conductor drawn through in PVC conduit mediun grade complete all as specified and directed. NOTE : (a) Cutting Chases shall be paid separately. (b) Four run of conductor, one run of earth conductor and one run of conduit shall be measured as one length.
M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm 1100 Volt alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm 1100 Volt as earth continuity conductor drawn through in PVC conduit mediun grade complete all as specified and directed. NOTE : (a) For concealed sub-main wiring cutting chases shall be paid separately. (b) Two run of conductor, one run of earth conductor and one run of conduit shall be measured as one length.
M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm 1100 Volt alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm 1100 Volt as earth continuity conductor drawn through in PVC conduit mediun grade complete all as specified and directed. NOTE : (a) For concealed sub-main wiring cutting chases shall be paid separately. (b) Two run of conductor, one run of earth conductor and one run of conduit shall be measured as one length.
M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm 1100 Volt alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm 1100 Volt as earth continuity conductor drawn through in PVC conduit mediun grade complete all as specified and directed. NOTE : : (a) For concealed sub-main wiring cutting chases shall be paid separately. (b) Two run of conductor, one run of earth conductor and one run of conduit shall be measured as one length.
Taking out old un-serviceable cable of any size from trench/pole/wall/OH complete all as specified and directed.
S & L XLPE insulated (Earthed), PVC Sheathed GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 10 Sqmm 4 core laid in trench/pole/on wall complete all as specified and directed.
S & L XLPE insulated (Earthed), PVC Sheathed GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 16 Sqmm 4 core laid in trench/pole/on wall complete all as specified and directed.
S & L XLPE insulated (Earthed), PVC Sheathed GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 10 Sqmm 2 core laid in trench/pole/on wall complete all as specified and directed.
S & L XLPE insulated (Earthed), PVC Sheathed GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 25 Sqmm 4 core laid in trench/pole/on wall complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for cable trenches and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
M&L for sand cushioning for protection of underground cable, consolidated and compacted with clean dry sand complete all as specified and directed.
M&L well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and directed.
M&L for 50mm dia GI pipe Light grade with all necessary fittings laid in trenches, fixed to wall/ pole/ under road/ floor etc for cable protection complete all as specified and directed.
Horizontal boring using ultra sound technique/any other suitable mechanical means at approx 1 metre below the road, pavement, hardstanding etc without damaging the existing surfaces getting out & disposal of soil to a distance not exceeding 50 metre from the site of work complete all as specified and directed.
Taking down carefully ceiling fan/ehaust fan any sweep and any make after disconnecting the electrical connection, complete all as specified and directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and directed.
S & F in replacement of DOL starter of capacity 1 HP 3 phase complete all as specified and directed.
S & F in replacement of DOL starter of capacity 2 HP 3 phase complete all as specified and directed.
S & F in replacement of DOL starter of capacity 2 HP 1 phase complete all as specified and directed.
S & F in replacement of DOL starter of capacity 5 HP 1 phase complete all as specified and directed.
S & F in replacement of onload changeover switch with enclosure of capacity 100 Amps 4 pole complete all as specified and directed.
M&L for earthing complete with galvanised earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below normal ground level with top edge of the plate not less than 1.50 mtr below normal ground level connected to galvanised lead lead wire 4.0 mm dia by means of bolts, nuts and washers and check nuts of galvanised iron or steel GI earth wire protected by 15 mm medium grade galvanised iron pipe including of 20 mm dia medium grade GI water tubing sheet metal 4mm wire mash funnel, charcoal or coke and common salt in paint and testing on completion as shown on electrical plate No.3 ofm SSR Part-I. including taking out unserviceable one complete all as specified and directed.
M&L for earthing complete with galvanised earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below normal ground level with top edge of the plate not less than 1.50 mtr below normal ground level connected to galvanisediron strip 32 x 6mm by means of bolts, nuts and washers and check nuts of galvanised iron or steel GI earth strip protected by 40 mm medium grade galvanised iron pipe including of 20 mm dia medium grade GI water tubing sheet metal 4mm wire mash funnel, charcoal or coke and common salt in paint and testing on completion as shown on electrical plate No.3 ofm SSR Part-I. including taking out unserviceable one complete all as specified and directed.
M/S R. K. INDUSTRIES
Prahalad Rai
M/S G D CONSTRUCTION
NEO BUILDERS
M/s KASHMIRA SINGH BARMI AND SONS
M/S JYOTI SHARMA AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .