Loading…
Loading…
Tender ID
Tender Value
₹5.8 Cr
EMD Value
₹11.7 L
Closing Date
24 Mar 2026, 12:00 pmClosed
Executive Engineer
Provincial Division PWD B and R DAC Complex Sangru
New Construction of Two 04 No. Permanent Courts at Judicial Court Complex Dhuri, Distt. Sangrur
2026_CEPW_163580_1
Bid No 95 Dt. 13-03-2026
Open Tender
Civil Works - Buildings
Percentage
180 days
Sangrur
Please refer Tender documents.
6 documents required · 6 mandatory
₹30,000
₹11.7 L
Yes
27 Mar 2026
13 Mar 2026
24 Mar 2026
13 Mar 2026
24 Mar 2026
13 Mar 2026
CIVIL WORKS:- Construction of Block A:- Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted )
Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC)
Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey
First Floor
Second Floor
Third Floor
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Centring and shuttering for stair cases with sloping with soffits including risers and stringers.
Extra Rate For First Floor
Extra Rate For Second Floor
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Extra Rate For Second Floor
Extra Rate For Third Floor
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Extra rate for using steel from Integrated plant marked as primary Producer steel.
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure
Extra Rate For First Floor
Extra Rate For Second Floor
12.5 mm thick cement plaster 1:5
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
20mm thick cement plaster 1:5 in two coat work
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
12.5 mm thick cement plaster 1:4
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
20mm thick cement plaster 1:4 in two coat work
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm Coupling /Sockets
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on- edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm
Extra Rate For First Floor
Extra Rate For Second Floor
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Extra Rate For First Floor
Extra Rate For Second Floor
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.
Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing
Extra Rate For First Floor
Extra Rate For Second Floor
Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur Green Marble Tiles of thickness 18mm to 20mm Slabs sizes above 0.50 sqm
Extra Rate For First Floor
Extra Rate For Second Floor
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra labour for projected nosing of stair case of any shape and design
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
Extra Rate For First Floor
Extra Rate For Second Floor
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Providing and fixing mineral fibre false ceiling tiles at height upto 4 mtr of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7)
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece..) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter.
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. 5.0mm thick Plate glass (INDIAN)
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1 (1999). Decorative with elm or gurjan facing on one side and teak facing on the other side edges lipped with teak with laminated core 35mm thick
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Providing and fixing stair case railing made out of M.S. Square bars 20x20m as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Construction of Block B
Earth work in exavation in foundations, trenches, etc. in all kinds of soil where pick jumper work is not involved and not exeeding 2.0 Mtr. depth and subsequent filling around masonary in 15 cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 Mtr. complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer In-Charge.
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted )
Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC)
Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey
First Floor
Second Floor
Third Floor
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Centring and shuttering for stair cases with sloping with soffits including risers and stringers.
Extra Rate For First Floor
Extra Rate For Second Floor
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Extra Rate For First Floor
Extra Rate For Second Floor
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Extra rate for using steel from Integrated plant marked as primary Producer steel.
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure
Extra Rate For Second Floor
12.5 mm thick cement plaster 1:5
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
20mm thick cement plaster 1:5 in two coat work
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
12.5 mm thick cement plaster 1:4
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
20mm thick cement plaster 1:4 in two coat work
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm Coupling /Sockets
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on- edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated all lead . CSR 6.8 C(i)
Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material.
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm
Extra Rate For Second Floor
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Extra Rate For First Floor
Extra Rate For Second Floor
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.
Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing
Extra Rate For First Floor
Extra Rate For Second Floor
Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur Green Marble Tiles of thickness 18mm to 20mm Slabs sizes above 0.50 sqm
Extra Rate For First Floor
Extra Rate For Second Floor
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra labour for projected nosing of stair case of any shape and design
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
Extra Rate For First Floor
Extra Rate For Second Floor
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Providing and fixing mineral fibre false ceiling tiles at height upto 4 mtr of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7)
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece..) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Providing and fixing false ceiling at height upto 4 mtr with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-T runners of size 1912SUB HEAD : 26- N 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter.
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. 5.0mm thick Plate glass (INDIAN)
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1 (1999). Decorative with elm or gurjan facing on one side and teak facing on the other side edges lipped with teak with laminated core 35mm thick
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Providing and fixing stair case railing made out of M.S. Square bars 20x20m as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
DISMANTLING
Stripping and stacking slate or tiles of a roof.
Earth work excavation in ordinary soil, exclusive of compensation of earth:-Earth work undressed with a combined lead upto 15 metres including breaking of clods.
Dismantling concrete Reinforced cement concrete
Removing doors and windows
Dismantling brick work tile, masonry or tile lining In cement
Disposal of Malba ouitside the premises including loading and unloading as desired by Engineer in charge.
Credit of Material to be received from dismentling
Tile from dismenling of tile terracing
Bricks from dismenling of Brick works
Brick/Tile bats
Credit of Steel & Iron
Construction of Corridor Block
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Extra Rate For Second Floor
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted )
Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC)
Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Extra Rate For Second Floor
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Extra Rate For Second Floor
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Extra Rate For Second Floor
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Extra Rate For Second Floor
Extra rate for using steel from Integrated plant marked as primary Producer steel.
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Extra Rate For Second Floor
Extra Rate For Third Floor
Providing and fixing chicken mesh for brick work and RCC junction of galvanized low carbon wire, annealed wire of diametre 0.6 to 2.0mm distance between the faces of the hexagon 13 to 50mm complete in all respect.
12.5 mm thick cement plaster 1:5
Extra Rate For Second Floor
20mm thick cement plaster 1:5 in two coat work
Extra Rate For Second Floor
12.5 mm thick cement plaster 1:4
Extra Rate For Second Floor
Extra Rate For Third Floor
20mm thick cement plaster 1:4 in two coat work
Extra Rate For Second Floor
Extra Rate For Third Floor
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm Coupling /Sockets
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on- edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
Extra Rate For Second Floor
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Extra Rate For Second Floor
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.
Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing
Extra Rate For Second Floor
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
Extra Rate for Second Floor
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Extra Rate for Second Floor
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Extra Rate for Second Floor
Extra Rate for Third Floor
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Extra Rate for Second Floor
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Extra Rate for Second Floor
Extra Rate for Third Floor
Sub Head-1 Internal Sewerage System
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B
110mm o/d single socket SWR UPVC pipe lines laid complete
90mm o/d single socket SWR UPVC pipe lines laid complete
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
For 110mm o/d pipes
Elbow 90 Degree (All side socketed)
Vent Cowls
Coupler
Single Tee With Door
Floor Trap 110mm x 110mm
For 90mm o/d pipes
Elbow 90 degree (all side socket)
Vent Cowls
Coupler
Single Tee With Door
Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge)
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting.
M.S. Holder bats clamps for 100mm i/d
M.S. Holder bats clamps for 75mm i/d
Core cutting in RCC slab 125mm dia or 150mm dia withe the help of core cutting machine as per requirement at site & as desired by Engineer-in-Charge.
Providing and fixing galvonised hanging clamp 100mm dia chimney type for PVC pipe, 12mm galvonised fully thread bar with nut bolt as per requirement at site & as desired by Engineer-in-Charge.
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm as per table-1
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal
Sub Head-2 Internal Water Supply System
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
CPVC SDR 11 Pipe & fitting 16mm o/d
SDR 11 CPVC pipes & fittings 20mm o/d
CPVC SDR 11 Pipe & fitting 25mm o/d
CPVC SDR 11 Pipe & fitting 32mm o/d
CPVC SDR 11 Pipe & fitting 40mm o/d
CPVC SDR 11 Pipe & fitting 50mm o/d
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
Through wall 11.43 cm thick
Through wall 22.86 cm thick
Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete.
20mm i/d Brass Ball valves
25mm i/d Brass Ball valves
32mm i/d Brass Ball valves
40mm i/d Brass Ball valves
50mm i/d Brass Ball valves
Sub Head - 3 Sanitary Installation
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.
Providing and fixing in position concealed cistern including flushing plate of approved make (to the approval of the Engineer- incharge) complete in all respect.
Providing and fixing jet spray with 2'-6" long PVC pipe.With PTMT nut
Providing and fixing Stainless steel health faucet complete in all respect.
Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
Vitreous white Chinaware Partition Large partition size 75 x 16.5 x 36.5 cm
Providing & fixing in position Water Dispenser Top Loading (with refrigration capacity 15 ltr) of approved make (to the approval of Engineer-in-charge) dispensing hot/cold/ambient water including cost of two no. 20 ltrs packaged drinking water bottles and carriage complete in all respect.
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.
Size 49 cm dia (above counter round)
Size 550 mm x 400 mm x 815mm
Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.
Double bowl Sink without drain board Overall size 1330x515 bowl size 560x410x200mm
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-in-charge) complete in all respect.
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
C.P brass towel ring
Providing and fixing in position C.P. Acryli shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer-incharge ) fixed in with rawl plugs and C.P brass screws complete in all respect.
CP brass Acrylic Shelf size 560mmx130mm
C.P. brass Glass Corner with rail 8 mm thickness and height 250 mm
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
C.P. brass Bib cock long nose/ long body without flange
C.P Brass bib cock foam flow without flange
Providing and fixing in position C.P. brass Foot operated auto closing valve for Basin taps and spouts (Table mounted)with two 900x1200mm long braided hoses with 15mm nuts of approved make (to the approval of Engineer-in-charge)
Providing and fixing in position C.P. Brass Foot operated auto closing valve with pressmatic Basin taps only with plug (Table mounted)with two 900x1200mm long braided hoses with 15mm nuts of approved make (to the approval of Engineer-in-charge)
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
C.P.brass 15mm Angle valve without flange
C.P.brass 15mm Concealed stop cock with flange
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm)
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories:
C.P. brass Bib cock with Wall flange
C.P.brass 15mm Angular stop cock with Wall flange
C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body)
C.P. brass toilet roll holder with flap
C.P. brass towel rack 600mm long with lower hangers
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 3 pegs
Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect.
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks
Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball
Brass Ball Cock with rod and Plastic Ball 50mm i/d
Providing and fixing in position cPVC Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
Tank nipple 32mm i/d
Tank nipple 40mm i/d
Tank nipple 50mm i/d
Construction of Plateform complete as per specification & as desired by Enginer-in-charge
For 2000 ltr Water Tank
Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect.
35mm dia 900mm (36”) long
35mm dia 1200mm (48”) long
Foldable U Type 762mm long
Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect.
Vertical Type
15 litre capacity water heater For VIP
25 litre capacity water heater
Sub Head-4 Flooring and Wall Tile
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
Extra rate for First Floor
Extra rate for Second Floor
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
Extra rate for First Floor
Extra rate for Second Floor
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete .
Extra rate for First Floor
Extra rate for Second Floor
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at mid specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in- charge.
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: i) Ist course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm).
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Extra rate for First Floor
Extra rate for Second Floor
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps..
Extra rate for First Floor
Extra rate for Second Floor
Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
Providing Internal Electrical Installations:
POINT WIRING:
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring fan point with sheet metal fan box
Wiring light point
Wiring call-bell point
Wiring 3 pin 6 Amp. wall socket point
Wiring 3 Pin 6 Amp. Plug control comprising wall socket point
Wiring 3 pin 16/20 amp. power plug control point
Wiring light point without control switch.
Wiring light point with double control switches.
RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).
RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:-
Ceiling Rose (Flush Piano type)
Call Bell 220/230 volts AC Ding Dong
LED'S FIXTURES & FANS:
Supply and erection of Slim Recessed mounted, Round downlighter 18 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %, housing & driver shall be of same brand, supported with LM 79 reports not more than 2 years old from NABL /UL accredited laboratory complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.
Supply and erection of Wall Fan Plastic Body 400MM, 16" including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
OCCUPANCY SENSORS:
Supply and erection of Ceiling mounted Occupancy based PIR sensor (360° detection angle motion detector) with installation height 3mts, 8.5 Amps resistive load, Detection dia 8M, time delay - 5s to 59 mins , Light level threshold - 5 to 1275 Lux, IP - 20, Sensitivity Adjustment, Walk LED test, with additional options like walkthrough, daylight set point, vacancy complete in all respect as approved and desired by the Engineer in-charges at site.
SUSPENSION RODS FOR CEILING FANS:
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan.
CONDUIT PIPE & COPPER WIRES:
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed
Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1sq.mm (Un-sheathed)
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
Overall size 4sq.mm (Un-sheathed)
Overall size 6sq.mm (Un-sheathed)
Overall size 10sq.mm (Un-sheathed)
Overall size 16sq.mm (Un-sheathed)
Overall size 25sq.mm (Un-sheathed)
MAIN VERTICAL DISTRIBUTION SYSTEM:
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-
TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp.)
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
MCCB Four Pole 100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
SUB DISTRIBUTION SYSTEM:
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
TP&N Vertical Double Door Distribution Board 4 way each.
TP&N Vertical Double Door Distribution Board 8 way each.
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
Cable End Box for TPN Vertical 4/8/12Way
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Four Pole 40amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve-C)
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-
PVC flexible pipe 40mm dia.
Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:-
PVC compression Socket gland 40mm dia.
EARTHING SYSTEM (INDOOR):
COPPER EARTHING 8SWG :- Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
COPPER EARTHING :- (Upto 14 metre in Length):-Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)
COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-
Additional Length 20mm x 3mm thick Copper Tape .
INDOOR LT CABLES, CABLE TRAY, DWC PIPE , BRASS GLANDS & THIMBLES:
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
Overall size 6sq.mm (2Core) Un-armoured (Loose)
Overall size 16sq.mm (4 Core) Un-armoured (Loose)
Overall size 25sq.mm (3½ Core) Un-armoured (Loose)
Overall size 35sq.mm (3½ Core) Un-armoured (Loose)
Overall size 50sq.mm (3½ Core) Un-armoured (Loose)
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.)
Double Walled Corrugated HDPE Pipe 160/ 136mm (Outer/ Inner dia.)
Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-
Brass Gland for Aluminium cable 2/3/4 Core size 6sq.mm
Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm
Brass Gland for Aluminium cable 2/3/3½/4 Core size 25-35sq.mm
Brass Gland for Aluminium cable 2/3/3½/4 Core size 50sq.mm
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
Aluminium thimble cable Core size 4 - 6sq.mm
Aluminium thimble cable Core size 10 -16sq.mm
Aluminium thimble cable Core size 25 -35sq.mm
Aluminium thimble cable Core size 50sq.mm
Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:-
Copper thimble cable Core size 4 - 6sq.mm
Copper thimble cable Core size 10 - 16sq.mm
SAFETY EQUIPMENTS:
Providing and fixing of 4.5 Kg. Capacity FIRE EXTINGUISHER,CO2 type as per IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
Providing and fixing of 6 Kg. Capacity FIRE EXTINGUISHER, ABC Powder type (stored pressure) asper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
Providing 1No. 13 Passenger Lifts, 3Stops & Extension of One Floor of 2Nos. 8Passanger Lifts:
Other Features: 1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers 10. Automatic phase reversal device and Phase Failure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual Rescue System 14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure. 28. The use of visually and accoustically reflective wall surace should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuity of people with impairements. 29. The floor of lift car should be slip resistant and have similar frictional qualities to thye floor of lift landing to decrease the risk of stumbling. 30. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight. 31. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids.
Extension of Single Floor of Existing 8 Passenger Elevator Machine room less (From 2nd floor to 3rd floor) with Standard Govt. Features: SCOPE OF WORK:- 1. Car Rail: Best available cut length rail will be given. 2. CWR Rail: Std 5Mtr rail will be given. 3. Brackets: New Cwt and car rail brackets. 4. Door: This will be current Prima G door which will technically match. existing landing door & new additional landing door 5. New Belts. 6. New Gov Rope 7. New RBI to suit current belt. 8. New Hall fixture for all floors. 9. New T/C and H/W harnesses 10. New COP will be provided.
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
Overall size 16sq.mm (4Core) Un-armoured (Loose)
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-
Overall size 16sq.mm (4Core) Un-armoured (On-Surface)
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)
COPPER EARTHING (8 SWG COPPER EARTHING): Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc.
MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:-
MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
SP&N Double Door Distribution Board 8 way each
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
Cable End Box for SPN 8 Way
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 6-32amp. (10kA, Curve-C)
Providing EPABX System:
Supply, installtion, testing & commisioning of SITC of 08 Port SLT extension card compatible with existing EPABX System complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, installtion, testing & commisioning of Analog phone with caller id and hand free facility. Make: Beetal/ Mitel/ Panasonic complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply Installation Testing and Commissioning of 20 Pair DB with Original Krone Module lock & key facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring Telephone socket point RJ11 (one module)
Supply and erection of telephone cable with solid bare copper conductor, special grade PE insulation, paired, polyster taped, nylon rip cord, FR PVC sheathed, conforming to TEC Specification No. G/WIR-06/03 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Telephone Cable 0.5 Sq.mm, 2 Pair
Telephone Cable 0.5 Sq.mm, 20 Pair
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
HDPE Electrical Conduit Pipe 25mm dia. (Flushed)
HDPE Electrical Conduit Pipe 40mm dia. (Flushed)
Providing Networking System along with allied accessories:
Supply, Installation and Comissioning of Distribution Switch with minimum usable 24 10/100/1000BASE-T ports, 2 10GBASE-T ports , 4 10G SFP+ ports L3 Stackable Managed Switch with Redundant Power Supply Support.1 x RJ45 console port, RJ-45 port for out-of band-management port for accessing the CLI of the switch and USB port. 168 Gbps Switching capacity or higher or non-blocking architecture. 64 Bytes packet forwarding rate should be 125 Mpps or higher. Switch MAC table should be at least 16K or higher. Physical Stacking up to 9 units per stack. Stacking bandwidth up to 80G and up to 32 devices per virtual stack. Should have 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning Tree Protocol and ERPS as per standard ITU-T G.8032. BPDU Filter, BPDU restriction, Root restrction. Loopback detection (LBD). IGMP Snooping v1/V2/V3 & IGMP groups 1K or more IGMP groups and require support for IGMP Snooping Fast Leave. MLD Snooping v1/v2 & MLD group 1K or more and require support for MLD Snooping Querier. 16 L3 IP interfaces and IPv4/IPv6 Loopback interface. IPv6 Neighbor Discovery (ND). VRRPv3, Equal-Cost Multi-Path (ECMP) and UDP helper. Static route for both IPv4 and IPv6, OSPFv1, v2 & v3, RIP V1/V2/ng. Should have Policy-based Route (PBR). IEEE 802.1Q VLAN with different type of VLAN like Port based, Voice VLAN, Private, Double (Q-In-Q), Multicast VLAN (ISM VLAN for IPv4/IPv6), 802.1v Protocol VLAN ,VLAN Trunking. should have per-port broadcast, multicast, and unicast storm control to prevents faulty end stations from degrading overall systems performance. port security to secures the access port based on MAC address. Require prevention of DoS attacks, which include Land, Blat, TCP Null Scan, TCP Xmas Scan, TCP SYNFIN, Ping of Death Attack and TCP Tiny Fragment attack. DHCP snooping and DHCP server screening, DHCP server. 802.1X port based and 802.1X host based access control, Identity-driven Policy (VLAN, ACL or QoS) Assignment. RADIUS and TACACS+ authentication. Authentication database failover. QoS (quality of service) IEEE 802.1P for traffic prioritization. 8 queues per port. Different type of QoS priority like Strict Priority Queue and Weighted Round Robin, Strict + WRR, Congestion control using Weighted Random Early Detection (WRED) or WTD. Remark 802.1p priority, Remark ToS/DSCP and Rate limiting in Policy map. Support at least 2K ingress & 512 egress access control entries. ACL based on MAC, IPv4 and IPv6, TCP/UDP port number, User-defined packet contentm, CPU Interface Filtering. Able to manage trough Web-GUI, Fully functional CLI interface and Telnet. Should have multiple Image and configuration support to reduced down time for the switches. sFlow for monitoring traffic in data networks, SNMP v1, v2c, v3 and SNMP Traps and RMON. Support for DHCP Client support for IPv4/IPv6, DHCP server, DHCP Relay and DNS client. Should have SNTP/NTP protocol for time synchronization. CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP-MED.. CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP-MED. Operating temperature should be 0 to 50 ˚C. Switch should be EMI Certificates FCC, CE and Safety Certifications cUL/UL, CB. All Switches, Wireless and its Networkiing Components from Same OEM. OEM Should be International certification for the ISO 45001 Health and Safety Management System, Information Security Management System: ISO 27001, ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 14064-1 Greenhouse Gas Inventory Standards. OEM should have Indian based operation at least for a period of 20+ years and should have an Annual Turnover of Rs. 500 Crores and above in any of last three consecutive Audited Financial years. (To ensure only principal networking companies participate having strong Product, Support and Service.) complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation and Comissioning of Patch Panel should be made of cold rolled steel.Should conform to TIA / EIA 568-C.2 Component Compliant.Should terminate 24 UTP CAT 6 (4 pair) Cables.Should confirm to EIA/TIA 568A wiring Pattern.Each port Should be features the spring-loaded shutter.Should be prevents incomplete mating Should be protects from dust and contaminants.Should be Front and rear port labelling as well as panel identification label.Should be Integral cable management shelf ensures bend radius compliance.Operating Life should be minimum 750 insertion cycles.Should be RoHS compliant.complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation and Comissioning of Patch Cord 1 Mtr Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross separator.Standard length should be available 0.5M to 10M.Should be RoHS compliant. complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation and Comissioning of 2 Mtr. Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross separator.Standard length should be available 0.5M to 10M.Should be RoHS compliant complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D ,Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC.as per DIN 41494 Standards complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respects as approved and desired by the Engineer in-charge at site.
RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring Networking socket point RJ45 (one module)
COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES: Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
CAT 6 LAN cable
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
Providing CCTV System:
Supply, erection, testing & commissioning of Indoor STQC Approved 3 MP IP WDR IR Rugged Mini Dome Camera OPERATIONAL: Video Standard: NTSC / PAL, Scanning System: Progressive, Image Sensor: 1/2.7” CMOS, Sensor Size (H x V): 4.608 mm x 2.592 mm, Number Of Pixels (H x V): 2304 x 1296, Minimum Illumination (Color/BW): .005 Lux / F1.6 (Color, 30 IRE), 0 Lux / F1.6 (IR ON), S/N Ratio: 50 dB, Electronic Shutter Speed: 1/8 ~ 1/32,000, IR Distance: up to 40 m, IR Light Control, Smart IR ( Auto / Manual ) / OFF, IR Light Number: 2, Day/Night: Auto (ICR) / Color / BW, Backlight Compensation: WDR, BLC, HLC, White Balance: Auto/Tungsten/ Fluorescent/ Daylight/Shadow/Manual, Gain Control: 0-100%, Wide Dynamic Range: 120 dB, Noise Reduction: 2D / 3D DNR, Lens: : 2.8 mm Fixed Iris, F1.6, Angle Of View: H: H:88°°, V:47°, Privacy Masking: Off / On (4 Areas), Defog: Not supported, Local Storage: Micro SD (up to 256 GB), Alarm Inputs/Outputs: Not supported, Pan Range: 0°-330°, Tilt Range: 0°-75°, Rotation Range: 0°-337°, Video Compression:H.265 HEVC/H.264/MJPEG, Smart Codec, Resolution: 1st: 2304 x 1296 / 1920 x 1080 / 1280 x 720 2nd: 704 x 576 (PAL) / 704 x 480 (NTSC) / 640 x 480 / 352 x 288 (PAL) / 352 x 240 (NTSC) 3rd: 640 x 480 / 352 x 288 (PAL) / 352 x 240 (NTSC) / 320 x 240, Number of Video Streams: 3 (2 for encryption), Frame Rate*: MAX 30 fps, Bit Rate*: 100K ~ 6 Mbps, Audio Compression: Not supported, Audio Stream: Not supported, Audio Interface: Not supported, NETWORK: Ethernet: 10 Base-T/100 Base-TX Ethernet (RJ-45), Supported Web Browsers: Chrome / Edge, Supported OS: Microsoft Windows 10, Protocols**: IPv4, IPv6, TCP / IP, HTTP, HTTPS, RTSP / RTP / RTCP, IGMP / Multicast, SMTP, DHCP, NTP, DNS, QoS, SNMP, 802.1X, UDP, ICMP, ARP, TLS, Interoperability: ONVIF Profile G/S/T, Maximum Users Access: 10 Users, Security: User account and password protection, HTTPS, IP Filter, Digest authentication, TLS1.2 only, Stream encryption, AES128 / 256, SSH / Telnet closed, PCI-DSS compliance, EVENTS / ANALYTICS: Built-in Video: Analytics, Motion Detection, Tampering, Event Type: Video motion detection,Recording notification, Event Linkage: Event notification using Email and MicroSD card, Region Of Interest: 8, ELECTRICAL: Power Supply: DC12V, PoE (IEEE 802.3af) (Class 0), Power Consumption (Max): MAX 3.6 W, MECHANICAL: Dimensions: Ø110.0 mm × 85.6 mm (Ø4.33” × 3.37”), Dome Diameter Ø78.2 mm (3.08”), Product Weight 0.56 kg (1.23 lb), Package Weight 0.65 kg (1.43 lb), Body Material Die-cast aluminium housing, ENVIRONMENTAL: Operating Temperature: Starting Temperature:-40°C ~ 60°C (-40°F ~ 140°F), Working Temperature: -40°C ~ 60°C (-40°F ~ 140°F), Relative Humidity Less than 90 %, non-condensing, Ingress Protection IP67, Impact Resistance IK10, REGULATORY: Emissions: FCC PART 15, CE (EN 55032), Complies with RCM and UKCA, Immunity CE(EN 50130-4), Complies with RCM and UKCA, Safety: UL LISTED TO UL/CSA 62368-1, CE(EN 62368-1), Complies with RCM and UKCA, RoHs: CE(EN 63000).complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, erection, testing & commissioning of 32 Channel Linux based Recording server (Network Video Recorder shall be support the STQC Cameras), 4 SATA interface, Up to 32 channel Video Inputs, Servershall have throughput of incoming bandwidth 512Mbps & outgoing 512Mbps, 2* HDMI , 1 *VGA Video output. Supports live view, storage, and playback at 1- 8MP resolution,Shall be capable of live streaming & Storing 32 cameras, Shall support Net HDD, Storage up to 8 TB Surveillance HDD,Shall support audio, G.711A/G.711U, Shall support 1 E-sata port, 2x RJ45 10M/100M/1000M ports,Audio input 1 channel, Audio Output 1 channel output , Alarm input 16 channel, Alarm Output 1 channel output, USB2.0*1, USB3.0*1+USB2.0*1 port , RS485*1,Protocol :IPv4, IPv6, TCP/IP, HTTP, HTTPS, DDNS,RTMP, SMTP(SSL), SNMP, DHCP, PPPoE, UPnP,NTP, P2P, FTP , Simultaneously record multiple streams in any combination of H.264/H.265/H.264+/H.265+, support Start, stop, normal play, back play, frame by frame forward, full screen, Fast forward / backward (2x, 4x, 8x,16x), Slow forward (1/2x, 1/4x, 1/8x,1/16x), Add custom/ Default Tag for any events at the time of playback, digital zoom, video clip, sub stream/main-stream, playback video bar, Shall be able to take actions pre and post recording, Send email, show message, send email, FTP upload video or screenshot, Cloud upload video or screenshot, full screen, voice prompts, Alarm output trigger, PTZ linkage on events, support the display of VCA metadata on video live-view and and playback, Supports AI from camera side : Face Detection, Human Detection, Vehicle Detection, Perimeter Intrusion Detection, Line Crossing Detection, Cross Counting, Heat Map, Crowd Density Detection, Queue Length Detection, License Plate Detection, Rare Sound Detection, Stationary Object Detection, Sound Detection, Capable to show statistics and graphs of events for different interval of time search, Shall support S.M.A.R.T HDD function for HDD status,Onvif Support , Power Supply : DC12V/2A ,Consumption without HDD : 12W , Temperature : -10°C~+50°C (14°F ~ 122°F) Humidity : Less than 90%RH , 378*326*66mm (W×D×H) Dimensions ,Certificates:CE, BIS, FCC, ROHS and REACH. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, erection, testing & commissioning of Switches: 24 Ports 10/100/1000 Mbps PoE + 4 Ports 10G SFP+ Smart Managed Layer 2 Switch, Power budget 370W from day1, Support 802.3af/at), Switching Capacity 128 Gbps, MAC Address Table 16K, Packet Forwarding Rate, 95.24 Mpps, Flash Memory 64 MB, DRAM Size 256 MB DDR3, IGMP v1/v2/v3 Snooping & MLD snooping v1/v2, 802.3x Flow Control, HOL Blocking Prevention, LLDP/ LLDP-MED, 802.1D, 802.1W, 802.1s, 802.1Q, 802.1p QOS, SPQ, WRR, WDRR, Bandwidth Control, Static routing, IPv6 Neighbor Discovery (ND), ACL Max. 768 rules shared by IPv4, MAC, & IPv6, Traffic segmentation, ARP Spoofing Prevention, ARP Inspection, DHCP Snooping, MAC authentication, SSH v2, TLS v.1.2, DoS attack prevention, 802.1X Port-based Access Control, Port Security, RADIUS/TACACS+, MD5 authentication, GUI, Full CLI, Telnet Server, TFTP Client, MDI/MDIX, SNMP v1/v2c/v3. Internal/External 6 kV surge protection on all RJ-45 access ports, Operating Temperature -5 to 50°C, Storage Temperature -20 to 70°C, Operating Humidity 0% to 95% relative humidity, Certifiate: EMC EN 55032, Class A; EN 61000-3-2; EN 61000-3-3; EN 55024, Safety EN 62368-1, ROHS EN IEC 63000, 47 CFR FCC part 15: 2017, Subpart V, Class A, ICES-003, IEC 62368-1, IEC 60950-1, IEC 60950-1/AMD1, IEC 60950-1/AMD2, UL 62368-1 & CAN/CSA C22.2 No. 62368-1-14. MTCTE/TEC-ER (as notified vide Indian Telegraph (Amendment) Rules, 2017, OEM Should be ISO 45001, ISO 27001 & ISO 14001 Certified, OEM Should have Certificate for Industrial Cyber Security Capability (Like - IEC-62443-4-1:2018 or Equivalent) complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, erection, testing & commissioning of HDD Formatted capacity 6 TB, Data transfer rate (max) Buffer to host Host to/from drive (sustained) 6 Gb/s 171 MB/s, Cache (MB) 64, Rotational speed (RPM) IntelliPower, Load/unload cycles4 300,000, Non-recoverable read errors per bits read <1 in 1014,Operating (2 ms, read/write) 30,Operating (2 ms, read) 65, Non-operating (2 ms) 250,Average power requirements (W) Read/Write 5.90, Idle 4.90, Standby and Sleep 0.40 complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, erection, testing & commissioning of Display : 50 inch, 4K (3,840 x 2,160), Direct LED, Professional Display with 4K Processor, Native Contrast ratio 5,000:1 or higher, Response time 12 ms or lower, Brightness 400 cd/m² or higher, 24/7, Portrait/Tilt functionality, HDMI Auto wake up, HTML5 platform, 16GB On Board Storage, HDMI*4 with HDCP 2.3 / RS232 / USB / RJ45 / Wi-Fi Direct / 20W Speakers / Android OS or similar, Viewing angle 178 degree, Apple AirPlay & Chromecast. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, Installation, Testing & Commissioning of 6 Mtr HDMI Cable for NVR, UL Listed complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D ,Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC.as per DIN 41494 Standards complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respects as approved and desired by the Engineer in-charge at site.
COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES: Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
CAT 6 LAN cable
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
Providing Fire Detection/ Emergency Evacuation & PA System:
FIRE PANELS & ANNUNCIATORS:
Supply, installation, testing & Commissioning of Addressable photo-Thermal multi criteria Detector and base with sensitivity range as per NFPA 72. The intelligent detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decimal switches. Designed to meet UL & FM Approved . The solution should be from single OEM complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Response Indicator for up side of ceiling complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Smoke photo-Thermal Detector and base with sensitivity range as per NFPA 72).The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signa! of the photoetectric signal in an effort to react hastily in the event of a fire situation. It shall aiso include the inherent ability to distinguish between a fire condition and a fa'se alarm condition by eramining the charactenstics of the tnermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decima! switches. Designed to meet UL & FM Approved The solutien should be from single OEM.complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL Listed.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes/ Telephone Jack. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Fire Fighter's Telephone Jack for two way communication between Remote Fire Fighter & Fire Command Center. Each Telephone jack should have separate address. complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling/Wall Mount Speakers. The speakers shall be of the same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms. UL Listed. Project specific OEM authorization required for executing agency complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Back box for speaker as per site requirement complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Exit LED M ST LED LED based exit sign with dimming function, Reading distance, exit sign Two-sided 25m, Voltage 220-240VAC / 50-60Hz, Power consumption 3.3W / 3.5VA, Battery 3.6V/1.2Ah NiMH, Battery protection Over charge protection /deep discharge protection, Charging Time 16 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source 15 LED, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IK rating IK09, IP rating IP40, Dimensions 265 x 53 x 222 mm, Weight 540 / 742 gr , Colour Anodized aluminum / black plastic, Materials Aluminum, Acrylic Plate, Mounting method Ceiling, wall bracket, suspended, pendulum, flag mount, Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch IP 40 – dustproof luminaire Reading distance upto 25 meters.High lumen output – 1h = 180lm / 3h = 110lm /8h = 40lm Technical lifetime of LED > 100 000 hours , 4 Pictograms (left, right, down, up) are included in the luminaire ordering part code complete in all respects as approved and desired by the Engineer in-charge at site.
Supply and erection of fire survival cable for fire alarm & PA system with annealed stranded copper conductor, fire resistant mica tape wrapped (at 950°C for 180 minutes), XLPE insulated, LSHZ (low smoke & zero halogen) bedding, LSZH (low smoke & zero halogen) red outer sheath, galvanized steel wire armour, 600/1000 volts grade, Fire resistant to IEC 331 & BS7846 F2/BS6387 & CWZ, Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3) left bare in pipe or casing or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-
Fire Survival cable 2Coe x 1.5 sq.mm
Providing PA System for Courts:
Supply, Installation, Testing & Comissioning of Amplifier Power Output:100W Max. THD. Output Regulation:≤ 2 dB, no load to full load at 1kHz. Input Channels: 5 X Mic 0.65mV/4.7kΩ, 2 X Aux 100mV/470KΩ. Frequency Response: 50-15,000Hz ± 3dB. Signal to Noise Ratio: 60dB. Tone Controls: Bass: ±8dB at 100Hz, Treble: ±8dB at 10kHz. Output: Preamp 200mV/600Ω, Line 1V/1kΩ. Speaker Output: 4Ω,8Ω,16Ω,70V & 100V. Digital Player: MP3 Player wih USB, SD & MMC Card Reader, Bluetooth. Power Supply: AC:220-240V 50/60Hz, DC:12V(12V Car Battery). Power Consumption: AC: 250VA DC: 5.5A..complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing & Commissioning of Speaker Power Rating: 50W Max. Power Taps: 30/20/10W. Impedance/Voltage: 80Ω/100V. Frequency Response: 50-20,000Hz. SPL at 1KHz (1W/1m): 87dB. Speaker: Woofer 163mm (6 ½"), Tweeter 25mm (1"). Dimensions: W215 X H310 X D175 mm. Weight: 3.80Kg complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing & Commissioning of Mic Frequency Response: 100-15,000Hz, Impedance: 1000Ω, Sensitivity: 7.0mV/Pa. Power Source: 3V-9V DC. Overall Length: 460mm(18") complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing & Commissioning of Mic Stand Heavy Duty Base, XLR Connector, 10m Twin Core shielded , 6.3mm (¼") phone plug, On/Off Switch complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing & Commissioning of Mic Cabling (5 Mtr) with connector complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respects as approved and desired by the Engineer in-charge at site.
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.05 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
SBD.pdf
Tender Documents • 33.96 MB
BOQ_331293.xls
BOQ • 0.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .