Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹14.6 L+₹5.6 L (62.2%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L2 | Rejected-Finance NOT BEING LOWEST. | |
| 3 | L3₹15.8 L+₹6.9 L (76.2%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST. |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
19 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT
GE (AF) BKT, LUCKNOW, C/O 56 APO, PIN - 901109
REPAIR/REPLACEMENT AND COMPREHENSIVE MAINTANANCE OF EARTHING SYSTEM AND SERVO VOLTAGE STABLIZER/UPS/FIRE ALARM SYSTEM ETC AT DIFFERENT LOCATION OF AF AREA UNDER GE (AF) BKT
2020_MES_380126_1
8436/BKT/E8
Open Tender
Civil Works
Item Rate
240 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) BKT
₹20,000
Yes
4 Nov 2020
23 Sept 2020
21 Oct 2020
23 Sept 2020
19 Oct 2020
7 Oct 2020
60 days
Amount
M&L for manual boring underground of 100 mm dia upto 30 mtr depth for each earthing below ground level in any kind of soil strata for insertion of pipe electrod 30 mtr length and coper strips etc. for bore earthing all as directed. ( 30RM X 10 Nos) complete all as specified and directed by Engr-in-Charge.
M&L for lowering Galvanised iron tubing, 50mm bore, light grade with all fittings accessories into the under ground bore for protection of earth strips complete all as specified and as directed.( 30 RM X 10 Nos) complete all as specified and directed.
Labour only for fixing and lowering copper strips 25x3 mm thick electrode up to bottom level of borewell for bore earthing and M & L filling with Chemical gel of any reputed manufacturer not less than 60 kg per earthing & connected to earthing test point terminal block including testing on completion to get earth resistance less than one ohm including 50cmx50cm size earth pit with PVC cover/CI cover complete all as directed and Earthing pit marker/ identifier of Steel plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia welded with steel plate including painting with one coat of red oxide and two coats of synthetic enameled paint of approved quality including writing letters,marking in different colors complete including testing on completion all as specified & directed. Note:- (i) Copper strip and GI pipe for protection of copper strip and test block will be measured and paid seperatly . The rate of material other than GI pipe and copper strip is included in the quoted rate of this item. (ii) The earthing result should be less than 1 ohm , contractor is liable to re-do the boring and chemical filling till the desired result achieved.
Supply only copper strip 20 mm x 3 mm (Labour rate included in item No 3 above) complete with saddles and fixing screws for fitting the strip for earth continuty conductor up to test points complete all as specified and directed.
Supply and laying in repair of Galvanised iron tubing, 40 mm bore, light grade with all fittings for fixed to pole/wall/ in ground including all fixing accessories complete for protection of earth strip all as specified and directed.
M&L for chemical Earthing with copper earth plate 600 x 600 x 6 mm thick buired directly in ground (earth pit not less that 12 feet deep below ground level and 4 feet side of square hole ) connected to copper earth strip 32x 6 mm by means of copper brazing after tighteened by bolts, nuts, check nuts and washers of copper from earth pit to test point protacted with GI pipe of size 50mm dia light grade for copper strip ,GI watering pipe 25mm dia light grade with funnel and wire mesh including PCC chamber of cement concrete and Pre-cast RCC Pit cover etc complete with alternate layer of salt crystal (200Kg), charcol (250Kg), magnesium sulphate crystal (100 Kg) all as specifed and directed. (Note :- (i) GI pipe 50mm dia for protection of earth lead & copper strip will be measured & paid seperatly. All other material & labour required for earthing including all earth work & dispasal of surplus soil to a distance upto 50m is included in the quoted rate (ii) The earthing result should be less than I ohm, contractor is liable to re-do the earthing complete as specifed till the desired result achieved.
Supply and fix in repair for copper strip of size 32mm x 6 mm for Earth continuity conductor or main earthing lead fixed on wall on insulator or in PVC pipe or chases or buried in ground or fixed to poles or any other position as indicated situation for loop earthing etc as directed. (Note :- Rate of necessary earth work for buried in ground required for fixing of copper strip are deemed to be included in the quoted rate)
S&F in repair in repair for Test point terminal block made of gun metal or in phosphorus bronze size 75mmx75mmx25mm drilled and screwed including 3 nos. 8 mm dia 25m long hex. head screw including connecting with earthing strip complete all as specified and directed.
M&L in repair for earthing pit as shown in eletrical plate No 3 of SSR part I (2009) with brick work and PCC 1:3:6 type B-1 using 20mm graded stone aggregate including 1:2:4 type B-1 using 20mm graded stone aggregate RCC pit cover of size 300mmx300mmx50mm thick with provision of opening handle complete including necessary watering, ramming and compact of soil near the earth pit all as specified and as directed.
M&L for dismantling of upper cover of servo Voltage stabilizer of capacity 75 KVA after disconnecting electrical connection for overall servicing , cleaning of dust and replacement of complete old wiring with FRLS copper conductor of suitable size in proper layout and tight with tie including replacement of any unserviceable parts i.e Electronic sensing card ( PCB), micro processor based panel,Potentiometer, RC Network with box, 6/12 pin connector, indicator, main transformers and dimmerstat (Variac) three phase or any other parts and fixing complete including testing, all as specified and directed. (Note : New parts will be measured & paid saparately under relevant items as supply only (fixing of new parts including in the items).
Ditto all as per item ser No 10 here-in-above but of capacity 315 KVA
Supply only dimmerstate (Variac) suitable for servo voltage stabilizers of capacity 75 KVA complete. Make- Vintek Electronics/volina
Supply only Dimmerstate (Variac) suitable for servo voltage stabilizers of capacity 315 KVA complete. Make- Vintek Electronics/volina
Supply only Electronic sensing card ( PCB) for 75 KVA servo voltage stabilizers. Make - Vintek Electronics/volina
Supply only Eelctronic serving card (PCB) for 315 KVA servo voltage stablizer complete all as directed. Make - Vintak Electronics/Volina
M&L for locating the fault in fire alarm control panel of capacity 4 Zone to 8 Zone including checking and rectification of defects, tighting loose connection of control panel, accessories etc including testing,replacement of any unserviceable parts to keep the lift functional and making the free movement of entire unit as directed by Engr-in-Charge. Note : (a) Replacement of any unserviceable parts will be measured and paid separatly under relevant items as supply only.
Supply only of PCB control card suitable for fire alarm control panel of capacity 4 zone complete all as specified and as directed by Engr-in-charge
S&F for power contector 3 pole type MNX 110 , Aux contacts 2 No+2NC complete all as specified and directed. Make :- L&T/ABB/Legrand
S&F for power contector 3 pole type MNX 95 , Aux contacts 2 No+2NC complete all as specified and directed.Make :- L&T/ABB/Legrand
Supply and filling new Oil brought in sealed barrel of capacity 200 Litre having strength of 50 KV at 2.5 mm gap complete all as specified and directed. Make : Power oil / SAVITA / Electrol.
M&L for Painting of Servo stablizer after cleaning the body surface by rubbing with emery Paper to remove oil stains, dust etc and applying two coat of synthetic enamel paint by spray paint incl writing SM No/MES No , capacity of Stablizer of 75 KVA to 315 KVA capacity all as directed.
M&L for manual boring underground of 100 mm dia upto 30 mtr depth below ground level in any kind of soil strata for insertion of pipe electrod 30 mtr length and coper strips etc. for bore earthing all as directed. ( 30 RM X 03 Nos)
M& L for lowering bore Galvanised iron tubing, 50 mm bore, light grade with all fittings accessories for protection of earth strips complete all as specified and as directed.( 30 Rm X 03 Nos)
Labour only for Bore Earthing complete for lowering of copper strips 20x3.15 mm thick electrode up to bottom level of borewell including filling with Chemical gel of any reputed manufacturer not less than 50 kg per earthing &connecting with earthing test point all as specified or indicated including testing on completion to get earth resistance less than 02 ohm. including 50cmx50cm size earth pit with PVC cover/CI cover complete all as directed. Note :- (i) GI pipe, copper strip will be mesured and paid seperatly as M&L and supply only respectively (ii) The earthing result to be obtined less than two ohm.
Supply only copper strip 20 mm x 3.15 mm complete with saddles and fixing screws for fitting the strip for earth continuty conductor up to test points.
M & L for Galvanised iron tubing, 40mm bore,light grade with all fittings for fixed to pole/wall/ in ground including all fixing accessories complete for protection of earth strip in repair complete all as specified and as directed.
Taking out old serviceable /unserviceable under ground cable of size 35 sqmm core 3.5 core to 50 sqmm 3.5 core following sizes from excavated trenches /pipes (Earth work, segragating cable cover shall be measured separately)
Supply, laying , jointing and testing XPLE insulated LT under ground cable, 1100 volts grade heavy duty, armoured with multi stranded aluminium conductor laid in trenches/ ducts, in pipes or on poles etc complete all as specified and as directed for the size 35 Sqmm 4 core.
Ditto all as item No 28 here-in-above but size 50 Sqmm 4 Core .
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 mtr wide including getting out in soft/loose soil complete all as specified and as directed.
Returning filling in, including leveling spreading watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed .
Removing of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
M&L for spreading clean dry sand in cable trenches for cushioning of cable protection complete all as directed. (Note :- Sand will be measured after punning).
Material & labour for bricks sub-class`B' (Old size), laid flat across the trenches for cable protection all as specified and directed.
M& Labour for locating the fault in E.O.T Crane of any capacity upto 10 Ton including rectification of minor defects such as tightening of nut and bolts, checking and rectifying loose connection of control panel, accessories and current collectors replacing of fuse wire, etc to keep the crane functional and making the free movement of entire unit as directed by Engr-in-Charge. (Note :- Contractor will send thier qualified rep & taking over the separate register for complaints and signed by concerned user rep, MES rep after rectifiying the complaint & submit the same before claiming the payment of item (ii) Each job comprises of one crane.
M&L Load testing of 10 ton EOT crane at 125% of the safe working load (dead weight load to be arranged by the Contractor). Note : Load for load testing shall be arranged by the contractor and record for the same shall be on kept in record duly signed by MES rep and no extra payment shall be made on this account. (b) Contractor will ensure all the cranes are in serviceable condition before starting the load testing. If any crane are in unserviceable condition the same will be made serviceable before starting the load testing.
M&L for Servicing of 10 ton EOT crane comprising of the following:- (a)Greasing/oiling of required part ie shaft, coupling, rope drum shaft bearing etc. (b)Checking & testing/adjustment of brakes for of all the motions ©Checking & tightening of coupling bolts, motor foundation bolt etc. (d)Checking the wiring connections in control panel and other accessories and to ensure that no loose/naked connection exist. (e)Checking of gear oil in gear boxes and topping them if necessary . (f)Checking of transformer oil in electro hydraulic thruster unit & topping if necessary (g) Cleaning of Bridge girder including plate form, cabin, panel, complete. (Note :- Each job shall mean each cranes.
M&L for Replacement of heavy duty thruster brake of dia 250 MM . Suitable for 10 Ton EOT Crane complete all as directed .
Supply and fixing LT motion crane coupling made of stainless steeel complete suitable for 5 Ton capacity crane complete all as specified and as directed by Engr-in-charge
Supply and installation testing and replacement of maintenance free battery of capacity 12 Volt 120 AH suitable for 100 KVA UPS with brass/copper terminal and copper cable of size not less than 25 Sqmm single core for interconnection battery complete all as specified and directed. Make :- Exide/Luminous/Microtek/Amron
Supply fixing including installation and testing of maintenance free battery of capacity 12 Volt 30 AH suitable for 10 KVA UPS with brass/copper terminal and copper cable of size not less than 16 Sqmm single core for interconnection of battery in repair complete all as specified and directed.
Dismantling and taking down existing unservicable UPS of capacity upto 100 KVA checking the seviceability of spare parts, wiring etc, repairing of Charger Card, Charger Firing Card and replacement of unserviceable parts with new parts, reassembling including new wiring,testing , commissioning of UPS with rated load complete all as specified and directed. Note : (Items required for replacement of worn out parts will be measured and paid separately under respective item as supply only but fixing of the same shall be deemed to be included in quoted rates)
Supply only Driver Card 8400-509C suitable for 100 KVA UPS for item No 42 here in before complete all as specified and directed
Supply only Inverter Control Card 8400/181 suitable for 100 KVA UPS for item No 42 here in before complete all as specified and directed
Supply only Static Driver Card 8400/505 suitable for 100 KVA UPS for item No 42 here in before complete all as specified and directed
M & L for checking the serviceability and Servicing of existing UPS of capacity up to of 100 KVA including testing at rated load for each quarter complete all as directed..
Unnati Engineers
H C CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .