Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹35.8 L+₹3.8 L (12.0%)Rejected-Finance | L2 | Rejected-Finance Being Not the Lowest Tenderer | |
| 3 | L3₹35.8 L+₹3.8 L (12.0%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L3 | Rejected-Finance Being Not the Lowest Tenderer | |
| 4 | L4₹39.2 L+₹7.2 L (22.6%)Rejected-Finance 138A STANLEY PARK OTTUPATTARAI POST COONOOR 643 105 THE NILGIRIS TAMIL NADU | THE NILGIRIS | TAMIL NADU | 643105 | L4 | Rejected-Finance Being Not the Lowest Tenderer | |
| 5 | L5₹39.9 L+₹7.9 L (24.8%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L5 | Rejected-Finance Being Not the Lowest Tenderer |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
1 Nov 2024, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
REPAIRS TO ELECTRIC INSTALLATION INCLUDING TAKEOVER POINTS AREA LIGHTING INCLUDING STREET LIGHTS COOLING APPLIANCES AND REPAIR REPLACEMENT OF INTERNAL WIRING INCLUDING DBs AND OTHER CONNECTED ITEMS FOR OTM AND MD ACCN AT ARMY AREA COIMBATORE AND MADU
2024_MES_677975_1
8940/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Coimbatore
As per Tender Documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹91,000
Yes
21 Dec 2024
4 Oct 2024
8 Nov 2024
5 Oct 2024
1 Nov 2024
18 Oct 2024
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation of poles, laying of cable trench etc, not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard /dense soil complete all as specified and as directed.
Returning / Refilling of excavated soil including spreading leveling and well ramming in layers complete all as specified and as directed.
PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundations filling and mass concrete for sub base of poles/ panels all as specified and directed.
Plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation filling of light poles and stays etc all as specified and directed.
PCC 1:2:4 type B-1 using 20mm graded stone aggregate for pedestal including necessary formwork finished fair using extra cement all as specified and directed.
Removing the surplus soil to a distance not exceeding 50 meters from the starting point and depositing at a height not exceeding 1.5 m above ground level complete all as specified and as directed.
GI tubing light grade, 40mm dia bore ISI marked conforming to IS 1239 for protection of cable fixed in wall or laid on trenches including removing taking down existing pipe complete all as specified and as directed.
GI tubing light grade, 80mm dia bore ISI marked conforming to IS 1239 for protection of cable fixed in wall or laid on trenches including removing taking down existing pipe complete all as specified and as directed.
Sand cushioning to PVC cable using clean dry riddled sand obtained from excavation gently punning below/around cable complete all as specified and as directed. Note: Punned thickness only will be measured and paid.
Supplying and laying reinforced precast concrete cable cover,Class LV, Type I, flat, size 250mm x 150mm x 40mm all as specified and directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 240 Sqmm 3.5 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Material and labour for boring of holes under road, pavement, hard standing, by trenchless technology using ultra sound technique and necessary machine including provn of HDPE pipe 110mm dia suitable for 0.4 mpa working pressure Depsoting bulk amount to Coimbatore Corporation competent authority for cutting or boring of Bituminous surface road for laying of cable and making good at their end for their satisfaction.complete all specified. Note:- Quoted rates deems to be inclusive of transportation charges of Drilling machine, connected accessories, HDPE pipe, Statutory charges for road cutting.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 95 Sqmm 3½ core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 70 Sqmm 3½ core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 50 Sqmm 3½ core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 35 Sqmm 3½ core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3½ core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 3½ core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Straight through cable jointing kit for 1100 Volts grade cable complete with jointing material heat shrinkable and accessories suitable for 3.5/4 core XLPE/PVC insulated armoured Aluminium conductor cable of size 16 Sqmm to 50 sqmm complete all as specified and as directed. Make : M Seal/Cab seal/Denson/RPG
Straight through cable jointing kit for 1100 Volts grade cable complete with jointing material heat shrinkable and accessories suitable for 3.5/4 core XLPE/PVC insulated armoured Aluminium conductor cable of size 70 Sqmm to 95 sqmm complete all as specified and as directed. Make : M Seal/Cab seal/Denson/RPG
Repair and replacement of Power Factor Capacitor Three Phase of capacity including taking down old item of Make Epcose / TC/ Siemens/ BCH / L&T / C&S complete all as specified and as directed.
Repair and replacement of Power Switching Contactor of make Epcose / L&T /C&S complete all as specified and as directed.
Repair and replacement of Power Switching MCB of Triple Pole of cap 20 Amps. of make Epcose / C&S/Hager/Havells / L&T complete all as specified and as directed.
Repair and replacement of APFC relay 8 way Make : AE / Ebrit or equivalent make complete all as specified and as directed.
MCCB of capacity 400 Amps 415 volts four pole 36 KA breaking capacity with adjustable thermal magnetic type complete fixed in repairs all as specified and as directed. Make: C&S Cat Part No CSE3N400ATM4P or equivalent in LEGRAND / SCHNIDER/ INDOASIAN
MCCB of capacity 200 Amps 415 volts four pole 36 KA breaking capacity with adjustable thermal magnetic type complete fixed in repairs all as specified and as directed. Make: C&S Cat Part No CSE2NN250ATM4P or equivalent in LEGRAND / SCHNIDER/ INDOASIAN
MCCB of capacity 100 Amps 415 volts four pole 25 KA breaking capacity with adjustable thermal magnetic type complete fixed in repairs all as specified and as directed. Make: C&S Cat Part No CSE1M125ATM4P or equivalent in LEGRAND / SCHNIDER/ INDOASIAN
MCCB of capacity 63 Amps 415 volts four pole 16 KA breaking capacity with adjustable thermal magnetic type complete fixed in repairs all as specified and as directed. Make: C&S Cat Part No CSE1M125ATM4P or equivalent in LEGRAND / SCHNIDER/ INDOASIAN
Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 meters long) fixing in true vertical position including taking down existing pole complete all as specified and as directed.
Cutting the existing bituminous surface road / concrete floor and including making good using PCC 1:3:6 type C1 using 20mm graded stone aggregate 250mm depth to match with the existing surface complete all as specified and as directed.
Welding, grainding, repair of locking arrangement and fixed in repairs of hinges of various size of LT, HT Panels, APFC Panels, Switch board complete all as specified and as directed.
Site clearance by cutting of shrubs, cutting of grass, bush weed, trees, sapling not exceeding in 30 CM girth and removal of grass with roots and leveling area and removal of same outside not more than 50m complete all as specified and directed.
Supply only breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers / connectors etc as per site requirement / capacity of transformer all as specified and directed.
Danger notice / Men at work plate of 1.6mm thick mild steel sheet vitreous enameled white with letter, figures and conventional skull & bones in signal red colour and fixed with MS clamps, bolts, nuts and of size 25x20cm for HT 11 KV including taking out old unsv rusted out danger plates all as specified and directed.
Polymer based dropout fuse unit complete set suitable and including for 11 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning including replacement all as specified and directed.
Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11KV and dismantling and taking out unsv lightning arresters aside in safe custody to issue under SoC including replacement all as specified and directed. Make : Elpro, Alstom, Oblum, Rastriya, Atlas, Pactil etc
Supply only large first aid kit box wall mountable metal cabinet size is 36cms L X 26 cms W X12 Cms D including all madicine inside for substations all as specified and directed
Sense Safety Fire Bucket Stand including 4 buckets Fire Bucket Stand, Hanging Capacity for 4 Buckets (Included) A fire sand bucket or fire bucket is a mild steel bucket filled with sand which is used to put out fires. Typically, fire buckets are painted bright red and have the word 'Fire' stenciled on them in white lettering. They are placed in prominent positions in rooms or corridors or out side all as specified and dirceted.
Material and labour for servicing, caliberation of APFC panel upto 100KVAR by disconnecting all electrical and mechanical connections for improvement of power factor close to unity but not less than 0.99 by replacement of faulty parts i.e. TPN MCB, MCCB, power contactor for automatic operation of APFC panel, togal switches, LED indicators, contactor coil and contacts, HRC fuse unit, power factor control relay, auto/manual switch and control wiring etc in complete and testing, finding out faulty parts and replacement that parts as per site requirement and re-assembling including testing complete all as specified and directed. Note: (a) Minor spare parts i.e. control wiring, cotton waste, LED indicators, contactor coil & contacts, CTC for cleaning, testing charges, calibration charges deemed to be included in the quoted rates. (b) Major parts such as MCCB, TPN MCB, capacotors, power contactor, control relay etc will be measured and paid separately.
Earthing complete with galvanized steel earth plate electrode size 600X600X6mm thick buried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and incl GI earth lead wire 4mm dia by means of bolts ,nuts, check nuts & washers of galvanized iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and as specified or indicated and testing on completion incl excavation and earth work in any type of strata available at site ,PCC (1:3:6)type C-1 earthing chamber ,pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with welded steel wire fabric weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade ,wire mesh and lugs ,GI protection pipe of 15 mm bore light grade up to 7.5 mtr long ,etc complete all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 mtr will be measured and paid separately
Preparation / cleaning of old painted steel surfaces of LT Panels, HT Switch boards and carrying painting with one coats of synthetic enameled paint first quality paint and writing SM/ MES No. 5 cm height with white synthetic enamel paint writing of block stencil cut MES No. 2cm height all as specified and directed.
Earthling complete with GI earth plate electrode 60x60cmx6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth strip of size 32x6mm by means of bolts and nuts washers mase out of GI and earth wire protected by Galvanized pipe light grade 15mm bore, 40 mm bore medium grade and connected to man control board all as shown in Electrical plate No 5 of SSR part I including necessary earth work and excavations in any type of soil PCC 1:2:4 type B1 chamber with 40mm thick, RCC 1:2:4 cover slab with 6mm dia MS bars etc complete all as specified and directed.
Taking down old GOD material and labour for 22 KV polymer type GOD Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, forcurrent rating upto 400 amps etc complete all as specified and directed.
Supply, install, testing and commissioning of factory made LT Busbar box, CPRI approved, ourdoor type, 1.1KV made out of MS CRCA sheet 3.15 mm thick, having 4 Nos Aluminium bus bar of size 200 Amps for phase 100 Amps for neutral fixed on LT, 8 Nos insulators of size 0.60M x 0.45 M with legs made out of MS angle 50x50x5mm and 0.75mtr in length, locking arrangements front and back opening danger notice board with skull & bone monogram and indicating 1100 volt danger board including incoming and outgoing connections and testing on completion complete all as specified and directed.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :-cables all as specified and directed :- (a) INCOMING:- (i) On load change over switches, 4 pole, 400 Amps rated current -1 Set (b) OUTGOING:- (i) MCCB 4 Pole, 36 KA, 250 Amps 415 Volts - 2 Nos (ii) MCCB 4 Pole, 16 KA, 100 Amps 415 Volts - 1 Nos (iii) MCCB 4 Pole, 16 KA, 63 Amps 415 Volts - 2 Nos (iii) MCB SPN 2 Pole, 16 KA, 40 Amps 415 Volts - 1 No (c) 200 Amps aluminium busbar for phase and 600 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulators in separate compartment - 01 Set (d) Digital multi function panel meter for measuring voltage, Amps and Frequency with suitable CTs and back up protection - 1 No (e) LED type Indication lamp 240 Volts Set of three - 1 Set (f) danger notice board of size 200 mm x 150 mm x 1.6 mm thick of mild steel sheet printed with vitreous enabled white paint and letter figure and convention skull and bones of signal red colour and fixed / rivetted with panel -02 Nos Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors.
Air termination, single pointed aluminium rod 12mm dia and 300mm long in repairs all as specified and directed.
Supply and fix aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw in repairs all as specified and directed
Supply and spread granite trap or basalt course aggregate size of 50mm to 20mm grade for the outdoor substation complete all as specified and directed.
Painting of zebra patta to RCC / Steel tubular poles ,at bottom portion with black and white paints up to height 1.2 meter in alternate strip manner (width of strip not more than 30cm) and writing MES Nos on LT Poles with black paint in capital letters of size 4cm height and 2 cm wide such as “LT-1, LT-999” with black on white back ground circle of not less than 16 cm all as specified and directed
Bollard light 8 watts LED 230 V AC outdoor type energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power with thermal management in multiple optics and equipped with IP-65 protection, complete with driver and lamp, including connection with suitable size of cable and fixed in repairs all as specified and directed. Make: Havells Cat Part No; BAMBOOBL8WLED857SSYMTDPCM or equivalent in Surya / Wipro
Supply and fixing well glass high bay LED light fitting 70 watts 230 volts AC outdoor type environmental friendly corrotion resistant vertical surface mounting pressure die-cast aluminium housing well glass luminaires with high power LED light source with IP 66 protection complete with driver and lamp complete all as specified and directed.
Pole mounted junction box of size 230 x 170 x 105mm made up of sheet moulding compound / PVC box type with hinged type door locking arrangement, white colour (out door type) with MCB SP 6 Amps fixing in the box including fixing accessories such as clamp, nut, bolts, washer etc complete all as specified and directed.
Material and labour for fabrication of name board box of size 1200mmx600mmx200mm for MES installantions made up of suitable angle frame and acrilic sheet duly mounted on angle iron frame of suitable size grouted on PCC plinth painted with two coats of enamel coating over a coat of red oxide primer and name of the installation should be printed as per the direction of Eng-in-charge complete all as specified and directed.
Taking down carefully sub main wiring with aluminium/ copper conductor cable 4/6/10/16 sqmm in PVC conduit complete removing materials from site and making good the disturbed surfaces of wall/ floor etc all as specified and directed.
Sub main wiring with two runs of PVC insulated multistranded copper conductor cable 4 sq. mm with one run of 4 sqmm as earth continuity including 25 mm dia PVC casing capping complete all as specified and directed. Note: 2 runs of 4 Sqmm cable, one run of 4Sqmm earth continuity and one run of 25mm casing/ caping shall be measured as one run.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete including tube light fittings, switches, ceiling roses, pendants, fan regulators, sockets etc removing material from site and keeping in safe custody for taking as schedule of credit/ depositing to MES store yard and making good to the disturbed surfaces of walls, floors, roof etc all as specified and directed.
Point wiring using with multistranded copper conductor 1.5 sq mm nominal cross-sectional area single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No. in and including PVC Capping and casing on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly completed with One light point controlled by one No. one way switch 5/6 Amps complete all as specified and directed
All as per item No 58 hereinbefore but One ceiling fan/exhaust fan point controlled by one No. one way switch 5/6 Amps complete all as specified and directed.
All as per item No 58 hereinbefore but one 3 pin 5 Amps socket outlet on the independent boards controlled by one 5 Amps switch complete all as specified and directed.
All as per item No 58 hereinbefore but One 3 pin 5 amps socket outlet on the same board with other switches controlled by one 5 Amps switch, complete all as specified and directed.
All as per item No 58 hereinbefore but 4 Sqmm PVC insulated and PVC unsheathed copper multi stranded conductor cable and 4 Sqmm multi stranded copper conductor for earth wire for 3 pin 15 Amps power points complete all as specified and as directed.
Switch piano flush button single pole one way. 5 amps 240 volts as per existing type and model complete all as specified and as directed.
Ceiling rose surface Bakelite three terminals 65x25mm PVC/ Polycarbonate isolated body all as specified and directed.
Lamp holder PVC/ Polycarbonate type with back plate suitable for angular fitting all as specified and directed.
Stepped switch type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required all as specified and directed.
Stepped socket type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required all as specified and directed.
Replacement of switch socket outlet 2 in 1, 3 pin, 5 and 15 Amps complete all as specified and directed.
Replacement of switch socket outlet 3pin, 5 flush type complete all as specified and directed.
Replacement of bell push, flush type 5 Amps all as specified and directed.
Replacement of bell push, flush type 5 Amps modular press type complete all as specified and directed. Make: Legrand Model Myrius or equivalent in crabtree/ Hello/ Anchor
Replacement of switch flush type 5 Amps modular press type all as specified and directed.
Replacement of switch flush type 15 Amps modular press type all as specified and directed. Make: Legrand Model Myrius or equivalent in crabtree/ Hello/ Anchor
Replacement of stepped type electronic fan regulator modular press type complete all as specified and directed. Make: Legrand Model Myrius or equivalent in Havells/ Crompton/ Anchor
Replacement of bell AC multi music type 230 volt all as specified and directed.
Taking down old unsv FTL fittings, Supply and fix 20W LED batten light Lum output 2000 CCT 6500K Size 115x2.5x3.5 cm comprises of thermally conductive material pre-wired with high efficiency electronic driver, high translucent serrated milky white diffuser gets glare free, smooth light distribution lamp colour white all as specified and directed. Make. Panasonic Product Code-. PBTM01207 or equivalent in Philips / Bajaj.
Supply and fix emergency LED bulb operating voltage 120-300 V AC IP 20 wattage 9 CCT 6500K lumen output 900 (Main) 350 (Battery) 4hr backup B-22 holder type all as specified and directed. Make: Panasonic Product code- PBUM13097 or equivalent in Philips/ Bajaj.
Supply and fixing well glass high bay LED light fitting 70 watts 230 volts AC outdoor type environmental friendly corrotion resistant vertical surface mounting pressure die-cast aluminium housing well glass luminaires with high power LED light source with IP 66 protection complete with driver and lamp complete all as specified and directed. Make: Havells Cat Part No ENDURAWELLGLASSGENXP70W LED 757PPC or equivalent in Philips/ Bajaj/ Panasonic
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and direcetd. Make: Surya Cat Part No SLE BT 10W ARROW or equivalent in Havells / Wipro
Supply and fixing LED light fitting mirror type with high out put diffuser 1 feet, 5 watt 220 V AC decorative type with driver holder and LED lampincluding connecting up with three core flexible copper conductor cable of suitable size complete all as specified and direcetd.
Supply and fix LED Lumen lamp 10 watt Ball Lamp for normal holder type cool day light 230/ 240 AC supply complete all as specified and directed.
Supply and fix candle LED lamp 3 watt E 14 candle Lamp for type cool day light 230/ 240 AC supply complete all as specified and directed.
Round shape 12 watt 220 volts AC 6500K recesse cum surface panel type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
LED luminaire 210 mm x 210 mm, 15/ 18 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
LED light fitting 36Watt having 5700K of 2' x 2' panel, ultra slim recess mounted edge type with high brightness LED package and unique pattern de-glaring PP diffuser and PS LGP de-glaring diffuser sheet for glare free uniform light distribution suitable for armstrong / grid ceiling with ceiling cutout (595 x 595)mm and height 35mm including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete in all respect all as specified and directed. Make: Panasonic Product code- PBLM22367 or equivalent in Philips/ Bajaj.
LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Havells Cat Part No ENDURASUNDOWN SL35WLED 765PASYBOPC or equivalent in Surya / Wipro
PVC insulated water proof multi stranded copper conductor cable 3 core 2.5 sq mm 1100 volts grade ISI marked for security light to the DB complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amps MCB complete all as specified and directed.
Supply and fix in replacement VTPN MCCB DB, 6 way suitable for three phase 440 volts with 200 Amps rated bus bar, double door type with provision for MCCB as incomer suitable for mounting incoming and outgoing MCB's single/double pole including dismantling of old existing complete all as specified and directed.
Supply and fix in replacement MCB DB, TPN 4 way suitable for three phase 440 volts with 200 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCBs single/ double pole including dismantling of old existing complete all as specified and directed.
Supply and fix in replacement MCB DB, SPN 4 way suitable for single phase 240 volts with 200 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCBs single/ double pole including dismantling of old existing complete all as specified and directed.
Supply and fix in replacement MCB DB, SPN 12 way suitable for single phase 240 volts with 200 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCBs single/ double pole including dismantling of old existing complete all as specified and directed.
240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP in the MCB DB complete with connection testing and commissioning all as specified and directed.
All as per item No. 93. hereinbefore but MCB SPN 32 Amps capacity complete all as specified and directed.
All as per item No. 93. hereinbefore but MCB TPN 63 Amps capacity complete all as specified and directed.
Supply only replacement ceiling fan condenser 2.5 MFD, 240 volt, AC complete all as specified and directed.
Supply and replacement exhaust fan condenser 4.0 MFD, 240 Volt, AC complete all as specified and directed.
Supply and fix in repair rubber shackle with nuts bolts, washers, split pin and canopy complete for hanging of ceiling fan of any size complete all as specified and directed
Re-winding the stator complete with super enameled copper conductor with the same size the number of turns as that the old one insulating, varnishing and pre heating for Ceiling fan 1200mm/1400mm sweep any model complete all as specified and as directed.
Re-winding the stator complete with super enameled copper conductor with the same size the number of turns as that the old one insulating, varnishing and pre heating for Exhaust fan up to 300mm sweep complete all as specified and as directed.
Re-winding the stator complete with super enameled copper conductor with the same size the number of turns as that the old one insulating, varnishing and pre heating for Exhaust fan above 300mm up to 450mm sweep complete all as specified and as directed.
Re-winding the stator complete with super enameled copper conductor with the same size the number of turns as that the old one insulating, varnishing and pre heating for wall mounted fan up to 300mm sweep complete all as specified and as directed.
Re-winding the stator complete with super enameled copper conductor with the same size the number of turns as that the old one insulating, varnishing and pre heating for Pedestal fan up to 400mm sweep complete all as specified and as directed.
Taking down of geyser any type and capacity for servicing and overhauling of water supply connection , de-scaling, reshaping of inner cell complete refixing the same after repair /servicing all as specified and directed.
Supply and fix in replacement of replacement of heating element cup type 2 KW complete all as specified and as directed.
Supply and fix in replacement of heating element triangular type 2 KW complete all as specified and as directed.
Supply and fix in replacement of heating element 2/3 KW of solar water heater complete all as specified and as directed.
Supply and fix in replacement of thermostat for geyser complete all as specified and as directed.
Supply and fix KWH Electric meter digital display single phase Class: 1.0, 50 Hz, 5 to 30 Amp, Temp 27 degree Celsius Marked complete all as specified and as directed.
Supply and fix KWH Electric meter digital display 3 Phase four wire Class: 1.0, 50 Hz 10-40 Amp , Volt : 3 x 240 V Marked complete all as specified and as directed.
Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings intrenches/roof for solar geyser lines complete all as specified and directed.
Supply and fixing of 20mm CPVC ball/gate valve complete all as specified and direcetd.
Taking down of solar water geyser any type and capacity for servicing and overhauling of water supply connection ,connectoin Rubber bhuses,glass tube rubeer busses de-scaling, reshaping of inner cell complete refixing the same after repair /servicing all as specified and directed.
Material and labour for replacement of Evacuated glass tube suitable for solar geyser of capacity 100ltrs complete all as speciifed and directed.
Taking down old unservicable street light at any height Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as speciifed and directed. Make:Panasonic product code - PSTM27458 or equivalent in Philips/ Bajaj
Taking down old unservicable street light at any height Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as speciifed and directed. Make:Panasonic product code - PSTM22608 or equivalent in Philips/ Bajaj
Taking down old unservicable street light at any height Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as speciifed and directed. Make:Panasonic product code - PSTM22908 or equivalent in Philips/ Bajaj
Taking down old unsv flood light at any height Supply and fixing LED flood light fitting 150 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as speciifed and directed. Make:Panasonic product code - PFLM18FG8 or equivalent in Philips/ Bajaj
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as speciifed and directed. Make:Panasonic product code - PFLM19708 or equivalent in Philips/ Bajaj
Supply and fix time light distribution board (Security light timer) time light contactor rating 32 Amps 3 pole MCB TPN 40 Amps Astronomical Timer street light panel for street light control with enclosure complete all as specified and directed.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
GI medium grade tube of 25mm dia, 1.5 metre long bend to shape 120 degree and 2Nos of MS clamp 25 x 4mm of required length/ size including nuts and bolts with one coat of red oxide and two coats of silver metallic paint fixed complete all as specified and directed.
Supply and fix in repair digital type street light timer and making connection complete as per original all as specified and directed. Make: L&T
Supply and fix in repair timer contactor of street light and making connection complete as per original all as specified and directed. Make:L&T, type MNX 40 3 pole contactor
Supply and connect PVC insulated water proof multi stranded copper conductor cable 4 core 4 sq mm 1100 volts grade ISI marked from street light pole to the panel as directed and specified. Make Finolex/ Incab/ polycab/ Universal ISI marked complete.
Painted steel and iron surface and painting of solar street light pole with one coat of synthetic enamelled paint upto 1.5 m height above from ground level/plinth block (in yellow and black strips of 30 cm wide each) and applying one coats of aluminium paint above 1.5 m height of poles complete with cross arms,braccing,clamps and brackets, battery box and writing pole Nos with black synthetic enamelled paint all as specified and directed.
Supply in replacement of battery 12 V, 80 AH complete all as specified and directed. Make: Exide GENPLUS Type: GP110D31L or equivalent to Amron/ TATA
Wiring for security lights cable junction box to lisht fittings using FR PVC insulated copper conductor cable of size 2 x1.5 Sqmm along with 1 x 1.5 Sqmm single core cable for earth continuity to be drawn in non metallic PVC conduit in surface / recessed all as specified and directed. Note: Two runs of PVC insulated cable with one run of earth wire and one run of conduit including accessories shall be measured as one length.
Material and labour for servicing of split type AC unit of any capacity/any make by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor / blower, by oiling, greasing, required welding/bracing, replacement of worn out rubber bushes of condensor motor, setting of grill alignment & knobs, Checking for any leakages, provision of thermocoal for air tightness, testing etc all as specified and directed.
Removing the unserviceable compressor from Split type AC and supply and fix new compressor suitable for 1.5 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/ filter and painting of base plate complete all as per existing one and all as specified and directed. Note: charging of gas shall be measured and paid separately. Make : Kirloskar/ Mitsubhishi/ Bluestar/ Tecumseh /Shri Ram or equivalent
Removing the unserviceable compressor from Split type AC and supply and fix new compressor suitable for 2 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and all as specified and directed. Note: charging of gas shall be measured and paid separately Make: Kirloskar/ Mitsubhishi/ Bluestar/ Tecumseh / Shri Ram
Charging of gas refrigerant R-22 & R-32 in split type AC 1.5 / 2 ton cap. of any make including flushing down refrigerant system with nitrogen gas, checking the leakage and rectification of any defect complete all as specified and directed.
Supply and fix in replacement condenser fan motor suitable for Split type AC 1.5/2 Ton out door unit single ended or double ended shaft as per existing one all as specified and directed. Make: AUE/ Marathon Electric or equivalent
Supply and fix in replacement fan motor of suitable for Split type AC 1.5 Ton indoor unit as per existing one complete.
Supply and fix in replacement fan motor of suitable for Split type AC 2 Ton indoor unit as per existing one complete.
Supply and fix in repair condenser coil made up of copper tubing and copper/aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity split type AC all as specified and directed.
Replacement of starting capacitor suitable for spilit type AC capacity up to 2.0-ton all as specified and directed.
Supply and fix in repair running capacitor suitable for window type AC up to 2.0-ton cap all as specified and directed.
Supply and fix in repair thermostat switch suitable for spilit type AC 1.5/2.0 ton capacity with temperature differential 2.5 + 1 C and working range 15 C to 30 C all as specified and directed. Make - INDFOSS/ RENUTROL/ DANFOSS.
Supply and fix in repair starting relay suitable for spilit type AC 1.5/2.0 ton capacity all as specified and directed. .
Supply and fix in repair overload protector suitable for spilit type AC 1.5/2.0 ton capacity all as specified and directed.
Supply and fix in repair copper cable PVC insulated sheathed 3 core 70/0.0076 all as specified and directed. Make-Havells/ Finolex/ RR Cables
Supply and fix in repair split valve ¼” for split AC 1.5 ton capacity all as specified and directed.
Supply and fix in repair compressor shut off valve 3/8” for split AC 1.5 ton capacity all as specified and directed.
Supply and fix in repair Puff insulation of copper pipe 3/8” (ID) for split AC with white tape all as specified and directed.
Supply and fix in repair remote sensing electronic panel of indoor unit suitable for 1.5/ 2 Ton AC all as specified and directed.
Supply and fix in repair remote controler suitable for existing type air conditioner unit suitable for 1.5/ 2 Ton AC all as specified and directed.
Supply and fix in replacemnt the copper piping 15 mm size suitable for 1.5 TR Split AC (suction and discharge) and power cable including the thermal insulation all as specified and directed.
Supply and fix in replacemnt the copper piping 20 mm size suitable for 2 TR Split AC (suction and discharge) and power cable including the thermal insulation all as specified and directed.
Supply and fix in replacemnt of Fan blade for outdoor unit upto 2 ton capacity in PVC and Iron as required on site complete all as specified and directed.
Supply and fix in repair PCB of split AC of capacity 1.5 Ton including taking down the unserviceable and making the all electric connection as existing complete all as specified and directed.
Supply and fix in repair PCB of split AC of capacity 2 Ton including taking down the unserviceable and making the all electric connection as existing complete all as specifed and directed.
Supply and fix in repair 1.5 TR indoor unit having Copper tubing and copper/aluminium cooling fins, filters including blower motor and shaft, remote sensing unit with display etc suitable for existing 1.5 TR Outdoor split AC unit complete all as specified and directed.
Removing the unserviceable compressor from water cooler & refrigerator of capacity 286/310 and supply and fix new compressor suitable for 40/80/150Ltr capacity of water cooler including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning of cooling coils necesary welding/ brazing and including required capillary tube complete all as specified and directed. Make: Kirloskar/ Tecumshe or equivalent Make Kirloskar/ Carrier/ Shri Ram
eurekaenterprises (BID ID -3155438)
SUPER COOL (BID ID -3148831)
JOE ENTERPRISES (BID ID -3151395)
KUMAR AGENCIES (BID ID -3153973)
Krishna Engineering (BID ID -3155412)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .