Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
14 Nov 2020, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
UPKEEP MAINT TO WATER SUPPLY INSTALLATION LEAKAGE SEEPAGE REPAIR AND OTHER MISC B R WORKS AT AF STN SULUR
2020_MES_389842_1
8372/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
26 Nov 2020
26 Oct 2020
16 Nov 2020
26 Oct 2020
14 Nov 2020
9 Nov 2020
26 Oct 2020 - 7 Nov 2020
Amount
SCHEDULE A BOQ
Dismantling fencing wire mesh, barbed wire any type and any size Note : The unit rate quoted is deemed to included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass/ trimming down shurbs/ branches/ small trees with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from fencing post to outside MD land
Excavation in post holes n exc 0.5m getting out,returning,filling in and rammed earth or broken rubble mixed with earth around, in layers not exc 25 cm in Hard/Dense soil complete all as specified.
Cement concrete (1:3:6) type C-1 (20 mm graded aggregate) as in foundation filling and mass concrete all as specified and as directed.
PCC in foundation filling and mass concrete type D-2, 1:4:8, using 40mm graded aggregate complete all as specified and directed.
Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (each line of wire to be measured) all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, cesspits, manholes, pier holes, etc. and getting out in hard/dense soil.
Providing type C-1, 1:3:6 (20 mm graded aggregate) precast cement concrete solid building block 10cm thick (with plain or interlocking joint as directed).
Straining and fixing only chain link fencing including line wires, any mesh size and any type of standards, rails, straining bolts etc inclunding M&L for 10mm dia MS bars as line wire welded to fencing posts and MS flat iron for fixing fencing wire mesh and including dismantling of fencing wire mesh of any type complete all as specified and directed.
Supply only chain link fencing of 4mm dia galvanised iron wire, mesh, any size or type weight not exc 4 Kg per Sqm.including provision of binding wire complete all as specified and directed. Note :- Weight of chain link shall be determined through BOO.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n exc 5cm long diameter of neck 5 to 10mm including taking down existing one complete all as specified and directed.
Rendering 15 mm thick in two layers on brick or stone or concrete surfaces,first coat 10mm thick in cement mortar 1:6 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. Note: (a) The unit rates quoted by the tenderer shall be deemed to inclusive for waterproofing compund. (b) The unit rate quoted is deemed to included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land Note: Periodicity of cutting of grass shall be before commencement of work and after completion of repairs.
M&L posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 including dismantling posts or struts (wood, steel or RCC) any section all as specified and as directed.
M&L preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide all as specified and as directed.
Note for item No 14 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
M&L for applying two coat of cement base paint over coat of primer including preparation of new plastered surfaces all as specified and as directed.
Supply only 10 mm dia round bars, cut to length hooking ends as in wooven /straining bar( stiches through chain link fencing between post)
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete including dismantling existing doors of gates all as specified and as directed.
Complete removal of existing water proofing treatment and expose of top surface of RCC slabof any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with water and using wire brush including removing debris to out side the MoD land and providing following :- (a) Dismantling existing cement concrete/roof tiles on roof including removing debris to out side MD land as directed. (b) Bring upto the slope by providing filling of light weight materials sch as cinder, light weight concrete etc as required, and then providing PCC 1:2:4 type B1 of average thickness of 50mm. (c) Rendering 10mm thick in CM 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 3% by weight of cement. (d) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (e) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (f) Providing APP modified water proofing as approved by GE weighing not less than 4kg per sqm unrolled over the bituminous coated surgace with 100mm over laps, the overlap shall be sealed by flame as per manufacture instructions complete. (g) Over the APP membrane, apply evenly a tack coat of hot air blown bitumen of grade 85/25 at the rate of 1.20 kg per sqm including cleaning of surface. (h) Applying a coat of aluminium paint at the rate of 100 gm per sqm as per manufacture instruuction over bituminous layer complete all as directed. Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
Plain cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in roof kerbs,benching rounded or chamfered on edge all as specified complete all as directed.
Repair of leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horinzontal pipe embeded in floor in bathroom or kitchen making good to the damage portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed by Engineer-in-Charge
Repair of leakage/seepage from the wall/ door bend /door tee/ 'Y' junction/ 'T' Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damage soil waste pipes or fittings of any shape, specification and size, making good to the damage portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and matching to existing wall complete to avoid the leakage/ seepage at the site of work as directed and specifie by the Engineer -in- charge
Note for item No 28 & 29 (a) Find out main cause of leakage and take necessary steps to resolve / rectify. (b) Replace existing tiles in case lakage through NT/FT. (c) The rate also include provision of new NT/FT. (d) The unit rate is also deemed to be included for reqd bonding chemicals to arrest the leakage/seepage as direct by the manufacturere specification. Make : M/s Sika Chemical, M/s Pidilite, M/s Dr Fixit
Taking down chowkhat or frame(wooden/steel) not exceeding 1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Taking down chowkhat or frame(wooden/steel) exceeding 1.50 Sqm not exceeding 4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Resecuring without taking down chowkhats or frames (without taking off shutters from the frames) not exc 1.5 sqm each.
Resecuring without taking down chowkhats or frames (without taking off shutters from the frames) exc 1.5 sqm but n exc 4 sqm each.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tubecomplete all as specified .
Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified.
150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
100 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
100mm long medium weight, stainless steel, butt hinges all as specified and directed.
75mm long medium weight, stainless steel, butt hinges all as specified and directed.
75mm long medium weight, stainless steel, butt hinges but fixed as in repair and welded to metal frame n exc. 2.5 cm in length and n exc 6 mm of metal thickness.
300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and Joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile of size exc 0.09 Sqm but n exc 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incuding screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) complete all as directed
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and Material and labour for Glazed ceramic coloured tiles 450 x 300 mm x 7/8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado/skirting including 10mm thick 1:3 backing coat complete all as specified and directed.
Note for item No 44 & 45 :- The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
Cleaning of air/dust blokages in the internal water supply lines concealed or fixed on the wall or floor surfaces by taking down carefully the fitting such as taps, valves, unions etc to facilitate/stimulate clearance of blockages/airlocks and re fixing the taking down carefully items after clearance of blockage/airlocks including fiiitngs etc complete all as specified and as directed
25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. all as specified and directed. Make : SFMC, Reliance Industries, KPT
Note for item No 48 :- (a) The unit rate shall be include for taking down existing GI pipe and connections and all fittings as directed.
(b) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(c ) Wall thickness of pipes shall be all as per IS : 15801
25mm outer dia of pipes PPR gate valves (brass insert) as per requirement of sites incl taking down existing one complete all as specified and directed.
Doom grating 125 mm dia with waste hole of PTMT(minimum weight 40gms) including taking existing one complete as directed by Engr-in-charge.
Vitreous china squatting pan 'Orissa' Pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe ) including provision of lime concrete bedding fixed in repairs all as specified and as directed.
Wash basin vitrous china (flat back and angle back Type) size 580x400mm including taps waste chain and plug and porceline stopper but brackets including cutting for and pinning in ends of brackets or erecting stand with waste pipe ,fixed including taking existing one complete as directed by Engr-in-charge.
PVC connection 15 mm size with PTMT nuts of length 450 mm including taking existing one complete as directed by Engr-in-charge.
PVC (SWR) 'P' trap of 110 mm bore including taking down all as specified and directed.
PVC (SWR) 'S' trap of 110 mm bore including taking down all as specified and directed.
Pillar taps 15mm bore CP with capstan head screwed down high pressure screwed for iron pipe Cat Part No CQT -23021KN of Jaquar or equivalent to /Parryware/Hindware/ Cera including taking existing one complete as directed by Engr-in-charge.
S&F in repair PVC Dual flush ceramic colour , low level, 10 litres capacity, star white with inlet float ball valve, PVC flush pipe and handle, making proper fixing and hanging arrangements Cat Part No 21029 of - hindware or equivalent all as specified and as directed.
Vitreous china wash down water closet pan (pedestal pattern), white (exluding fixing bolts,flushing cistren and flushpipe) and including seat cover for pedestal pattern complete fixed in repair, all as specified and as directed.
Antimicrobial solid plastic water closet seat cover for EWC with flat bottom and cover and mild steel chromium plated hinging device including taking existing one complete as directed by Engr-in-charge. Cat Part No C8094 of Parryware or equivalent to Hindware/Cera all as specified and as directed.
CP 2 way bib cock with wall flange fancy type screwed down screwed for iron pipe in repairs 15mm bore CAT Part No-Sl. No-CQT-23041 Jaquar or equivalent in Parryware ,or as per list of makes Including taken down existing one complete all as specified and as directed by Engineer-in-Charge
32mm low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm for WHB including taking down all as specified and as directed.
Glass self assembly including taking existing one complete as directed by Engr-in-charge. (Make : CAT Part No-ACN-1173 continental of Jaguar series or equivalent make of Parriware /Hindware all as specified and as directed.
PVC connection 15 mm size with PTMT nuts of length 375 mm including taking existing one complete as directed by Engr-in-charge.
Taking down & re fixing high or low level flushing cistren 10 ltrs capacity & connections to pipes & fixing of chain & pull or lever after cleaning inside of all dirt, scale formation, replacement of rubber washers, stopping of leakage etc complete all as specified and as directed
Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Note for item No 68 : (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Easing of door shutters for easy closing/opening and tightening of hinges or changing the position of hinges, adjustment of tower bolts, sliding bolts with new screws etc, Size of door upto 2 Sqm single leaf or double leaf complete all as specified and directed by Engineer-in-Charge.
Easing of window shutters, kitchen cupboard shutters, show case shutter drawers including fixing of screws adjusting handles, knobs tightening piano hinges including misc small adjustments , size of window upto 1.5 Sqm. complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description exc 1.0 Sq.m and n.exc 2.0 Sq.m each complete all as specified and directed.
30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); all as specified and directed.
Flush shutters,30mm thick, solid core construction, with particle board core and ply wood face panels, commercial type on both sides, complete all as specified and directed.
Floor door stopper of aluminium body and tongue anodized with two rubber bush 150mm, in repair all as specified.
100 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
5mm thick rubber beading strips of entrance doors having width exc 3CM to not exc 5CM to arrest entry insects including taking down existing one complete all as specified and as directed
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm fixed all as specified and as directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm fixed including taking down existing one all as specified and as directed.
Mild steel work angle, bars, flat iron for fencing , wall ties, hold fasts, clamps, handles, straps and similar small articles conforming to Fe-410-o or Fe-310-O complete all as specified and directed.
Cutting holes in stone wall exc half brick and n.exc one brick in cement mortar for inserting hold fasts and making good desmantled portion in cement mortar 1:3 or 1:2:4 type B-1 concrete as required.
Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Preparation of new wood or wooden surface of any description not othrwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Note for item No 83 :- (a) All synthetic enamel paint, plastic emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
100 mm thick plain cement concrete type D-2, 1:4:8 (40mm graded aggregate) to receive tile including demolition of existing concrete and disposal out side MD land as directed by Engineer-in-Charge.
Chequered cement concrete tiles 30cmx30cmx25mm thick machine pressed set jointed and pointed in neat cement slurry as in floors and cut and polished using gray cement and pigments over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) including taking down existing tile any type/ description as directed The manufacturer's test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
20 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. all as specified and directed. Make : SFMC, Reliance Industries, KPT
Note for item No 94 :- (a) The unit rate shall be include for taking down existing GI pipe and connections and all fittings as directed.
(b) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc.
(c ) Wall thickness of pipes shall be all as per IS : 15801
20mm outer dia of pipes PPR gate valves (brass insert) as per requirement of sites incl taking down existing one complete all as specified and directed.
S&F in repair of gun metal globe or gate valves 20 mm bore with iron wheel head screwed both ends for iron pipe and fixed all as specified all as specified and as directed.
Bib Cock with wall flange screwed down screwed for iron pipe in repairs 15mm bore CAT Part No CQT -23047 of Jaquar or equivalent to Parryware/Hindware/Cera including taking existing one complete as directed by Engr-in-charge.
S&F in repair Towel rail 24" long for wash basin Make: (Make : CAT Part No-ACN-1111NM of Jaguar series or equivalent make of hindware / parriware all as specified and as directed.
S&F in repair CP Soap dish CAT Part No-ACN-1131N of jaguar or equivalent make of Parriware /Hindware all as specified and as directed.
Cast Copper Spindle suitable for 15/20mm bore bib tap and stop cock, fixed in repairs complete all as specified and as directed
CP Hand shower (Health Faucet) with 1M Flexible tube with 8mm dia wall hook with NRV (Back flow preventor) including taking down existing one complete all as directed CAT Part No ALD CHR-579 Jaquar or equivalent in Parryware, ESS-ESS all as specified and as directed.
Angular stop cock, valves high pressure screwed both ends iron pipe or for unioins 15mm dia, CAT Part No G3007A1 of Parryware or equivalent to Hindware/Cera including taking existing one complete as directed by Engr-in-charge.
Towel Ring round including taking existing one complete as directed by Engr-in-charge. Make: (Make : CAT Part No-ACN-1121BN of Jaguar series or equivalent make of hindware / parriware all as specified and as directed.
Petty repairs to leaking water in pillar tap, stop cock, angle valve, bib taps of any description by changing the washer, head/ phase etc. all as specified and as directed.
Hard core of broken/crushed stone aggregate of gauge n.exc 63 mm deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size, polished confirming to IS-15658 of 60mm thickness M-35 grade, laid over and including M sand cushion of 50mm thick and making side packing with PCC 1:3:6 type C1complete all as specified and directed in repairs. Note : The Unit rate quoted is included for Demolition of Stone Slabs and tiles of any description or thickness in floors,aprons etc laid bedded and pointed in any mortar
100mm thick, plain cement concrete (1:2:4), type B-2 (using 40 mm graded mechanically crushed stone aggregates), laid in 1:20 slope as in hard standing including making joints 1t 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, complete including demolish existing concrete as specified and as directed including removal of debris outside MD land as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
Hacking out old borken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 sqm each pane complete all as specified and directed.
Hacking out old borken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass exc 0.5 sqm each pane complete all as specified and directed.
Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in skirting/dado. etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:3 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Note for item No 113 : (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Applying silicon sealent on joints of wall,cill jambs roof etc complete all as specified as directed
6mm thick frame less bevelled edge mirror fixed with steel stud as per direction of Engineeer-in-charge including taking down all as specified and as directed.
25mm dia mild steel powder coated drapery rod out to length required without joint in between and fixed at openings including taking existing one complete as directed by Engr-in-charge.
Mild steel powder coated brackets for holding the drapory rod and fixed to wall with MS screw including taking existing one complete as directed by Engr-in-charge.
Supply and Fixing in repairs Mild steel powder coated fancy type brackets fixed at both the end of drapery rod of same colour and type of drapaery rod as directed.
False ceiling at any height with "Armstrong Ultima micro look tiles" manufactured by M/S Armstrong world industries using hot dipped galvanised steel section exposed surface chemically cleaned capping prefinished inbaked polyster paint, main tee of size 3000x32x15mm at 1200c/c and cross tee of size 1200x32x600 at 600mm c/c and wall angle of size3000x19x19mm around the wall to form grid of size 600*600 mm centre to centre.Hanger ofGI wire of 4.0mm dia to be fixed by approved roof plug' level adjusters and screws etc, The last hanger at the end of each main runner should not be greater than 450mm from the adjacent wall. Perimeter wall angle and micro look grid runner has to be on the 600x600mm mould including taking down of existing ceiling board of description complete all as directed. Make Armstrong or equivalent make as per list of makes
75mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates), laid in 1:20 slope as in plinth protection/path including making joints 1t 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size, polished confirming to IS-15658 of 80mm thickness M-40 grade, laid over and including M sand cushion of 50mm thickand making side packing with PCC 1:3:6 type C1 complete all as specified and directed including removal of debris outside MD land as directed. Note : The Unit rate quoted is included for Demolition of Stone Slabs and tiles of any description or thickness in floors,aprons etc laid bedded and pointed in any mortar
300mm arc size, 5mm thick corner glass shelf with stainless steel brackets, stainless steel railing in bathroom and fixed to wall with brackets including removing the existing fitting including taking down existing one , complete all as specified as per manufacturer's instructions and as required at site complete all as specified and as directed
PVC connection 15 mm size with PTMT nuts of length 600 mm including taking existing one complete as directed by Engr-in-charge.
Preparation of new or previously untreated steel surfaces of any description, n exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
Note for item No 125:- (a) All synthetic enamel paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
250 mm mild steel ordinary rat rail rod pattern spring including roller and roller plate including taking down existing one all as specified and directed.
Supply and Fixing of stainless steel peg set of having 5 pegs powder coated fixed to wall surface with pvc plug and screw complete all as specified and as directed.
Removing excavated material to a distance exc. 1.50km but n exc. 5km and depositing where directed
Neptune Engineers and Builders
NAVEEN ENTERPRISES
jk construction
devan enterprises
G Perumal and co
KUMAR AGENCIES
T C KARUNANITHI
Lucky Enterprises
SARAVANARAJA CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .