Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73,409Accepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹98,785+₹25,376 (34.6%)Accepted-Finance | L2 | Accepted-Finance OK |
Tender Value
₹1.4 L
EMD Value
₹2,822
Closing Date
18 Apr 2023, 3:00 pmClosed
Executive Engineer (Elect)
T.E. Building KBN, Room No -25, Kidwai Bhawan MTNL, New Delhi-110001
Providing Electrical works at Room No 111 allotted to GM(OP) and Room No 112 allotted to GM (Law),Eastern Court, MTNL,ND
2023_MTNL_749015_1
EE(E)KBN/2023-24/13-04-23/03
Open Tender
Electrical Works
Item Rate
7 days
Kidwai Bhawan
Please refer Tender documents.
6 documents required · 6 mandatory
₹590
MTNL Delhi
₹2,822
20 Apr 2023
13 Apr 2023
19 Apr 2023
13 Apr 2023
18 Apr 2023
13 Apr 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required
Supplying and drawing following size of FRLS PVC insluated copper conductor, single core cable in existing surface / recessed steel/ PVC conduit/PVC chanel as required. a) 3 x 1.5 sqmm
b) 3 X 4 sqmm
c)3 x 6 Sqmm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all accessories etc. as required.
S/F following sizes / modules surface/recess mounting GI box along with modular base & cover plate for modular switches in recess/surface/wooden/ply board etc as reqd.(M/S Anchor/Havells/LEGRAND/L&T) make)a) 2Module
b)3 module
c) 12 module
d) 8 module
S/F following modular switch / socket/Regulator on the existing modular plate & switch box including connections but exlcuding modular plate etc as reqd. ( ANCHOR/LEGRAND/Havells/L&T.) a) 5/6 amps switch
b) 15 / 16 amps switch
c) 5 pin 5 / 6 amps socket outlet
d) 6 pin 15 / 16 amps socket outlet
e)Bell push
f)e) Stepped type electronic fan regulator
S/F HYLAM sheet to cover existing board i/c cutting fixing with screws as reqd.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator)a)12 way double Door .Make-M/s Havells/Legrand/L&T/ABB/C&S
Supplying and fixing following rating MCB/Isolator in the existing SDBs connections complete as reqd.-M/s Havells/Legrand/L&T/ABB/C&S a)63 Amp DP Isolator
b)5/15/32 A SP MCB
Supplying & fixing the recessed mounting Ultra modern recess luminaire suitable for armstrong/grid/POP ceiling complete with separate electronic driver & high brightness SMD LEDs with 30 W ( 1 ft X 4 ft ) diffused type lighting system on the existing false ceiling with hanging arrangement i.e direct/by using chains ,fastner as per site requirement and minor adjustment, connections with proper connector from both sides in existing ceiling to accommodate the fitting as per the site requirement etc. complete as reqd.(Make: Havells /philips/Syska/Crompton/orient/Bajaj)
Conversion of existing 36 W tube light fitting in to LED fitting by using led tube light ranges (20 to 22 W) i/c necessary wiring modifications etc as reqd . Make M/s Philips/Havells/Osram/Bajaj/Syska/Surya/Orient
S/F 4 feet LED Batten fitting with integral electronic driver operated on 230 V 50 Hz AC Supply on surface with mounting arrangement connections etc. complete as required (System wattage 20-22 W system, lumen output-1850-2000 lumens etc.)(Make: Havells /philips/Syska/Crompton/orient/Bajaj)
Supplying & fixing of Engagement light/busy light fitting comprising of two brass holder with 0.5 W Red and Green colour LED Bulbs (LED Bulb make-M/s Havells/Bajaj/Osram/crompton/surya/Philips ) suitable for 230 V 50 Hz AC supply & aesthatically finished metalic body with front removable glass cover i/c connection testing etc as reqd
Supplying and fixing call bell/ buzzer suitable for single phase,230 V,%) Hz AC supply i/c connection testing etc complete as required.Make-M/s Anchor/CONA/Philips/Antex
Supplying and fixing 400 mm Sweep wall mounted fans suitable to work on single phase, 230 V, 50 Hz A.C Supply complete with blades, wire guard, built-in speed regulator including testing, commissioning etc. complete as required.(M/S Usha / Almonard/Crompton/Orient/Havells/Bajaj/Luminous/Kaithan make)
S/F 1200 mm sweep AC 230 volts single phase ceiling fan with all accessories including blades capacitor connection testing etc as reqd.(M/S Cromption /USHA/Orient/Bajaj/Luminous/kaithan/Crompton make)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess/ wooden partions including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a)20 mm steel
(b)25 mm steel
©20 mm PVC
S/F 25 mm PVC batten with casing & capping on existing wall/ply surface etc as required M/S AKG,Legrand
Dismantling of Old fittings, conduit wirings, old faulty DB ,switch sockets etc as per site requirement.
Handa Electric Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .