Office of The Executive Engineer, TLMD-VIII, Jammu
Office of The Executive Engineer, TLMD-VIII, JKPTCL, Ambedkar Chowk, Jammu
Design, engineering, testing, commissioning and dismantling of material of damaged tower(LILO) line in loc no 3 and supply, erection of material for location no 3 of Line IN of 132 KV Chatha Miran Sahib Transmission Line
2026_PDD_301747_1
e nit no TLMD-VIII/J/T/13 of 2025-26 dated-29/01/2026
Open Tender
Electrical Works
Turn-key
90 days
Chatha
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, TLMD-VIII, JKPTCL, Jammu
₹13,740
Office of The Executive Engineer, TLMD-VIII, Jammu
11 May 2026
31 Jan 2026
16 Mar 2026
31 Jan 2026
13 Mar 2026
31 Jan 2026
9 Feb 2026
Supply of material
Design, Engineering, Supply of Galvanised Tower structure as per site requirement (D type)
Nuts & Bolts
200 mm² ACSR Conductor,(a) Alumunium=30/3 mm(b) Steel=7/3 mm Overall dia 21mm.Approximate Wt 976Kg/Km Ultimate breaking Load=89.67 KN;including 1.5%sag and jumpering
Single Tension Fittings for panther shall have minimum failing load of 100% ultimate strength of Bundle cnductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. 90% (6 NoS/C,12NoD/C Per Ten. Towers)
Erection of Material
Erection of Galvanised Tower structure as per the site requirement
Nuts & Bolts
Dismantling of existing conductor and stringing of conductor for 0.25 Kms for double ckt towers
Dismantling of existing and stringing of Earthwire
Single Tension Fittings for panther shall have minimum failing load of 100% ultimate strength of Bundle cnductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. 90% (6 NoS/C,12NoD/C Per Ten. Towers)
Dismantling
Dismantling of Existing Buckled tower
Write back of dismantled tower from site to division store includning head load of 250 mtrs
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
SBDnit13.pdf
Tender Documents • 3.29 MB
BOQ_979040.xls
BOQ • 0.27 MB
Extension3NIT13.pdf
PDF • 0.47 MB
corrigendum2nit13.pdf
PDF • 0.26 MB
corrigendumnit13.pdf
PDF • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .