Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Finance | Not Admitted-Finance Others-. |
| 4 | Not Admitted-Finance | Not Admitted-Finance Others-FDR not submitted |
Tender Value
Refer Docs
EMD Value
₹13,800
Closing Date
11 Jan 2023, 11:30 amClosed
EE(EnM)M-11
Apollo BPS Near Apollo Hospital Sarita Vihar Mathura Road New Delhi - 110076
Renovation or Improvement of Internal Electrification Works at Dakshinpuri BPS under Ambedkar Nagar Constituency AC-48.
2023_DJB_234216_3
NIT No. 33/EE(EnM)M-11/2022-23
Open Tender
Miscellaneous Works
Works
30 days
EE(EnM)M-11
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹13,800
27 Feb 2023
4 Jan 2023
11 Jan 2023
4 Jan 2023
11 Jan 2023
4 Jan 2023
Supply of LED (Tube Light) Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. Lamp Type Order. 18 W LED 6000 K (DJB Code 19.1.1) Make: Havells/Orient/Bajaj/Philips/CG
Supply of LED Street Light 70/72W (DJB Code 19.10.6) Make: Havells/Orient/Bajaj/Philips/CG
Supply of 450 mm (TP) Exhaust Fan. (DJB Code 20.2.3) Make: Havells/ Orient/ Bajaj/ Philips/ CG
Supply of 600 mm size Air circulating Fan. (DJB Code 20.30.2) Make: Havells/ Orient/ Bajaj/ Philips/ CG
Supply of 1200 mm size Ceiling Fan. (DJB Code 20.1.2) Make: Havells/ Orient/ Bajaj/ Philips/ CG
Providing of PVC/XLPE insulated (heavy Duty) Electrical Cable for working voltage up to and including 1100 volts to IS:1554 (part-I) 1988/7098 (part-I) with aluminum conductor- ISI marked power cable- aluminum for size 10 Sq.mm 2 core Armored cable. Make: Havells/ polycab/ Any DJB approved make.
Wiring for light point / fan point/ exhaust fan / call bell point / with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.(DSR E&M 2018) 1.8.3
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required from main DB to (a) HT Room 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire 150 mtr (b) Transformer rooms 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire 425 mtr (c) Store room 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire 250 mtr (d) Staff room 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire 275 mtr (e) Toilet 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire 100 mtr (DSR E&M 2018) 1.14.2
Supply and fixing metal box of following sizes ( nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 300 mmX 250 mm X 60 mm. (DSR E&M 2018) 1.22.15
Supply and fixing metal box of following sizes ( nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 180 mmX 100 mm X 60 mm.(DSR E&M 2018) 1.22.5
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 A switch(DSR E&M 2018) 1.23.1
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 A socket outlet (DSR E&M 2018) 1.23.4
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A switch (DSR E&M 2018) 1.23.3
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 A socket outlet (DSR E&M 2018) 1.23.5
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (DSR E&M 2018) 1.25
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire (DSR E&M 2018) 1.14.3
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.(DSR E&M 2018) 1.44
Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/ LED lamps per fitting, complete with all accessories including connections etc. as required.(DSR E&M 2018) 1.35
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.(DSR E&M 2018) 7.7.1
12 way (4 + 36), Double door (DSR E&M 2018) 2.5.3
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole (DSR E&M 2018) 2.10.1
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Triple pole (DSR E&M 2018) 2.10.4
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Triple pole a following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Double pole (DSR E&M 2018) 2.10.3
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Triple pole and neutral (DSR E&M 2018) 2.10.5
N.R. Enterprises
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .