Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.7 Cr+₹1.4 Cr (109.7%)Rejected-Finance | ₹2.7 Cr+₹1.4 Cr (109.7%) | L2 | Rejected-Finance L2 |
| 3 | L3₹3.3 Cr+₹2.0 Cr (158.6%)Rejected-Finance 13 8 4 REVENUE WARD 13 THATHAIAH GUNTA TIRUPATI ANDHRA PRADESH 517501 | CHITTOOR | ANDHRA PRADESH | 517501 | ₹3.3 Cr+₹2.0 Cr (158.6%) | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical DELHI | CENTRAL DELHI | DELHI | 110002 | - | - | Rejected-Technical Technically not qualified |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
11 Jun 2021, 2:00 pmClosed
Chief Manager (C and P)
Pride Purple Coronet, 2nd Floor, Baner Road, Baner, Pune - 411045
Setting up captive CNG station inside premises of M/s. Toyota Kirloskar Motors Pvt, Ltd., Bidadi for MNGL, Ramanagara (Karnataka)
2021_MNGL_78330_1
MNGL/CP/2021-22/30
Open Tender
Civil Works
Works
165 days
RAMNAGARA
As per Tender document
15 documents required · 15 mandatory
₹0
₹2 L
Yes
MNGL, Baner, Pune
30 Aug 2021
29 May 2021
14 Jun 2021
29 May 2021
11 Jun 2021
29 May 2021
29 May 2021 - 3 Jun 2021
4 Jun 2021
Amount
PART-A Liasoning & Permission Work
Follow-up with the authorities for PESO initial approval,grant, endorsment or any other approval required,Building permission,CP/DM NOC,Fire NOC,etc,if any.
PART- B Civil & Structural Work SECTION -I(SITE CLEARANCE)
Demolition of Brick/Stone masonry:- Site clearance by demolition of Brick/stone masonry/ in walls, stone soling, PCC, pavior blocks in flexible/rigid pavements etc., removing the debris or any type of material and disposal of serviceable or unserviceable material to any lead as per technical specifications and directions of the Engineer-in-charge.
Dismantling of Bolted/ welded structural steel fencing:- Dismantling of existing bolted /welded steel fencing erected on 1.50 m high brick wall complete in all respect and disposal of serviceable or unserviceable material to any lead as per technical specifications, tender document and direction of Engineer-in-charge
Temporary Barricading:- Providing and fixing temporary barricading using GI sheets and ISA 50x50x6 mm, grouting of angle etc. complete in all respect as per technical specifications, tender document and direction of Engineer-in-charge
Surface Dressing:- Surface Dressing of ground including removing vegetaltion trees of girth upto 40 cm removing all inequalities not exceeding 15 cm deep and disposal fo rubbish to any lead as per technical specifications, tender document and direction of Engineer-in-charge
SECTION - II :( EARTHWORK)
Earth work in excavation/site grading:- Earth work in excavation in all kinds of soil except rock in any plan dimension up to 3.0 M depth including disposal of excavated earth up to any lead in all conditions, and disposal of surplus and unserviceable earth. Soil to be leveled and neatly dressed complete in all respect as per scope of work, detailed construction drawings, as per technical specifications and directions of the Engineer-in-charge.
Earth work in excavation same as above but beyond 3.0m and upto 6.0m
Earth work in hard rock: Excavation in hard rock including PCC, RCC, pavior blocks in flexible/rigid pavements etc., removing the debris or any type of material and disposal of serviceable or unserviceable material to any lead as per technical specifications and direction of EIC (The Contractor shall take into account in his rate, the provision for excess excavation for necessary working space, slope etc., required for excavation and other allied works and refilling the side slopes and working space)
Earthwork in filling: Earth work in filling with good quality imported earth from approved source in the layers of 150 mm and compacted up to 95% to its MDD up to 4 m depth and any plan dimension including all testing, watering, rolling each layer with 1/2 tonne roller or wooden or steel rammers, and every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing / filling up ground depressions etc. complete in all respect as per scope of work, detailed construction drawings, as per technical specifications and directions of the Engineer-in-charge.
Supplying and filling Sand in 150 mm thick layers watering, rolling, ramming, consolidating and dressing the surface including cost of sand (zone-II/Zone-III sand only) complete in all respect as per scope of work, detailed construction drawings as per technical specifications and directions of the Engineer-in-charge.
Stone Soling / Rubble massonry:- Providing and laying stone ballast 115 to 150 mm size in layers of 300 mm thick or 1: 4 rubbly massonry with spreading & blinding material like sand, stone grit and compaction with mechanical means, watering etc. including cost of material complete in all respect as per scope of work, detailed construction drawings as per technical specifications and directions of the Engineer-in-charge.
SECTION - III : (CONSTRUCTION WORK)
Brick Work in foundation with CM 1:4:- Providing, construction and handing over of brick masonry foundations below DPC including weepholes, plastering of 15 mm thickness in CM 1:4 on exposed surfaces, mudmat, excavation and backfilling with serviceable earth, complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge.
Brick Work in superstructure with CM 1:4:- Providing, construction and handing over of brick walls of superstructure plastering of 15 mm thickness in CM 1:4 on both the faces complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge.
PCC:- Providing, laying in position, construction and handing over of PCC in foundations, substructure, superstructure and under floor, etc complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge.
a) PCC 1:2:4 [1 Cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size]
b) PCC 1:3:6 [1 Cement : 3 coarse sand : 6 stone aggregate 20 mm nominal size]
c) PCC 1:4:8 [1 Cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size]
RCC in foundation (M-20 gr):- Providing, laying in position, construction and handing over of RCC 1:1.5:3 in foundations, substructure and under floor including shuttering inserts/ anchor bolts, sleeves, two coats of bitumen paint on surfaces in contact with soil etc complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge.
RCC in foundation (M-25 gr):- Providing, laying in position, construction and handing over of RCC 1:1:2 in foundations, substructure and under floor including shuttering inserts/ anchor bolts, sleeves, two coats of bitumen paint on surfaces in contact with soil etc complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge.
RCC in superstructure:- Providing, construction and handing over of RCC M20 in superstructure elements such as walls, retaining walls, columns, beams etc. including shuttering inserts, conduits, openings, accesses, edge protection etc. complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. [1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade cement, coarse sand and coarse aggregates, other minor construction materials, shuttering, staging, shoring/strutting, finishing, testing etc. all bye works and sundry works.]
Reinforcement steel:- Supplying and Fabricating and Fixing in position HYSD Steel Reinforcements/ TMT Grade Fe-415 conforming to IS1786-1985 at all levels and positions including the Cost of transport, Straightening, Cutting, Bending, Cranking, Binding, Welding, Provision of necessary Chairs and Spacers, Preparation of bar bending schedule Drawings, getting the same approved etc., as per Drawings and Specifications and including Cost of binding wire, Labour etc., all complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. The chairs and spacer bars provided will not be Measured for payment.
Compound wal:- Providing, constructing and finishing of compound wall in brick /RCCmasonry 300 thk with RCC 375/460 mm square pillar at interval of 3.0 m or as specified in construction drawings, and height 2.1 m as per scope of work detail construction drawings, including plastering, coping, painting, GI Pipe,whitewash, finishes all complete as per technical specifications and direction of the Engineer-In-Charge.
BUILDING WORKS:- RCC framed structure building [Refer PREAMBLE BUILDING WORKS RCC FRAMED STRUCTURE BUILDING]. Providing, construction and handing over of RCC framed structure building, including reinforcing steel, finishes, fittings, fixtures, complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge.
RCC FLOORING IN FORECOURT:- Providing construction and handing over of 150 mm thick RCC 1:1:2 (Nominal mix strength not less than 25 N/mm2 conforming to IS) forecourt over 100 mm thick PCC (1:3:6) & 150 mm thick Brick bat soling ( 63mm to 90mm) including reinforcement steel complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge.
PAVER BLOCK FLOORING IN FORECOURT:- Supply, construction and handing over of CC inter locking paver block 80 mm thick, I shape, rough finish, M-40 strength with epoxy coating of approved brand laid over the sand bed of minimum 75 mm thick. The CC interlocking blocks to be of uniform Grey colour or as approved by EIC complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge.
Single SS Tube Trench in Forecourt:- Providing and construction of Single SS tube trench in RCC over the 100 mm thick PCC (1:4:8) base with precast SFRC cover of 600x550X 70 mm thk alongwith edge angle (ISA 75x75x6) and fixing of ISA 50x50x6 for supporting pipetrays @ spacing of 1000 mm c/c along the trench, including 12 mm in CM 1:5 plastering of walls of trenches complete in all respect as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge.
Double SS Tube Trench in Forecourt:- Same as above for Double SS tube trench.
External sewerage and Water Piping:- (A)Supply, laying and commissioning RCC pipes of 300 dia including earth cutting, filling, disposal of surplus earth, bed concrete, RCC pipe, SW gully trap/ chamber, grease trap, all complete in all respects as per scope of work, detailed drawings, technical specification and directions of the Engineer-In-Charge.
(B)Supply, laying and commissioning RCC pipes of 150 dia including earth cutting, filling, disposal of surplus earth, bed concrete, RCC pipe, SW gully trap/ chamber, grease trap, all complete in all respects as per scope of work, detailed drawings, technical specification and directions of the Engineer-In-Charge.
Electrical & Water Pit chamber Construction:- Providing and construction of Electrical Cable Pit of size 600x600x900 including PCC to be carried out at base, brickwork, SFRC cover and its frame over the chamber, leaving space for GI pipe fixing complete in all respect as per technical specification, construction drawings and direction of Engineer In Charge
SECTION - IV : (FINISHING WORK)
Plaster in CM 1:4:- (A)Providing and laying 12 mm thick cement plaster on walls, RCC beams, columns and chajja etc of mix 1:4 ( I cement, 4 fine sand) including making of typical grooves drip-course including hacking of RCC roof beams and columns surfaces and curing etc. The job includes the cost of supplying and fixing of chicken wiremesh at every joint of brick masonry and RCC before commencing the plastering work complete in all respect as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge.
(B)Providing and laying 19 mm thick cement plaster on walls, RCC beams, columns etc of mix 1:4 ( I cement, 4 fine sand) including making of typical grooves drip-course etc including hacking of RCC roof beams and columns surfaces and curing etc. complete. The job includes the cost of supplying and fixing of chicken wiremesh at every joint of brick masonry and RCC before commencing the plastering work complete in all respect as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge.
Painting ( APEX / Weathercoat / Weathershield) :- Supplying and applying 3 coats of Apex paint of Asian paints / Weathercoat of Berger paints / Weathershield of ICI paints on external walls surfaces in approved colour at all heights as per scope of work and recommendations of manufacturer including surface preparation, primer putty etc. detailed construction drawings , technical specifications and directions of the Engineer-In-Charge. [Rate to include priming coat of putty, scaffolding, tools & tackles, consumables etc complete. ]
Painting (OBD):- Supplying and finishing internal walls and ceilings in plaster of paris punning to achieve an even finish and applying 3 coats of Oil Bound Distemper of Asian paints/ Berger/ICI brand in approved colour including surface preparation, primer, putty etc. as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-In-Charge.
White washing:- White washing with Dehradun/Rajasthan lime in 3 or more coats to give an even finish including the cost of adding required adhesive (DDL), blue pigment (Robin Blue) etc. on walls, ceiling etc. complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge.
Providing and fixing Granite Stone over Dispenser Island:- Providing and fixing 20 mm thick polished, machine cut granite stone for dispenser islands of required size and approved quality laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement , mixed with matching pigment, epoxy touchups, including rubbing, making edge moulding, curing etc all complete as per detailed construction drawings, technical specifications and directions of the Engineer-In-Charge.
IPS Flooring:- Providing and laying 40 mm thick cement concrete floor with 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate of 12 mm nominal size) with a floating coat of neat cement all complete as per detailed construction drawings, technical specifications and directions of the Engineer-In-Charge. [Rate to include all labour tools, tackles, hire charges, water charges PVC/glass strips etc complete.]
WEARING COURSE OVER RCC FLOOR:- Providing & laying in panels 50 mm thick, 1:1:2 ( 1 cement, 1 fine aggregates, 2 (6mm) coarse aggregate ) screed with wire mesh of 4 mm thick & 75 mm square over RCC floor, all complete as per scope detailed drawings, technical specifications and directions of the Engineer-In-Charge.
Polycarbonate sheeting:- Providing and fixing 4 mm thick multiwall polycarbonate sheets of required canopy roof shapes and sizes and erecting them on roof/facia at proper position, all work as per specification, drawings and direction of EIC. [Rate to include all labour, tools, tackles, hire charges, water charges etc complete.]
Providing and fixing ceramic glazed wall tiles:- Ceramic glazed wall tiles of the approved size and of the appropriate specification shall be fixed in the walls using mortar with proper finishing as mentioned ias per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge.
Providing and fixing vitrified tiles 600 x 600 mm:- Vitrified glazed floorl tiles of the approved size and of the appropriate specification shall be fixed in the floor over the subbase, pointing, cutting, curing and proper finishing as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. [Rate to include all labour, tools, tackles, hire charges, water charges etc complete.]
SECTION - V : (METAL WORK)
Steel structure fabrication:- Supplying, Fabricating & Erecting in position steel structures fabricated out of MS Girders, channels, Tees, angle, flats, plate, square hollow sections pipes etc. conforming to IS:2062 and/or from pipes conforming to IS:1161 for structural purpose for cascade supporting structure, loading/unloading platform, Gratings for platform, handrails, hoardings for signage, safety signboards,etc. of any size/dial for required design including cutting, welding, bolting, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel paint over a priming coat of approved steel primer etc complete as per scope detailed drawings, technical specifications and directions of the Engineer-In-Charge.
Providing and fixing Fencing Structure:- Supplying, fabricating & fixing steel structural fencing fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, painting with enamel paint in approved shade including supply of all raw materials, bolts, electrodes, transportation, including making pockets & pouring with PCC (1:2:4) in of block 500x500x500 for fixing of posts etc complete as per enclosed sketch, technical specifications and directions of the Engineer-In-Charge. (A) Fencing height 2.1 m
Providing and fixing Fencing Gates:- Supplying, fabricating & fixing fencing gates fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, painting with enamel paint in approved shade including supply of all raw materials, bolts, electrodes, transportation etc complete as per enclosed sketch, technical specifications and directions of the Engineer-In-Charge. (A) 2m Wide and fencing height of 2.1 m
Providing and fixing Fencing Gates:- Supplying, fabricating & fixing fencing gates fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, painting with enamel paint in approved shade including supply of all raw materials, bolts, electrodes, transportation etc complete as per enclosed sketch, technical specifications and directions of the Engineer-In-Charge.(B) 4/5m Wide and fencing height of 2.1 m
Providing and fixing chequered plate covers:- Providing and fixing chequered plate in approved panel or over steel structure including cutting, welding, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved steel primer etc complete as per scope detailed drawings , technical specifications and directions of the Engineer-In-Charge.
Providing and fixing safety guard Dispenser /LCV:- Providing and fixing safety guard with 80 mm heavy duty MS Pipe (size 450 deep and 300 width inside) grouted with ready mix high strength grout mortar of approved manufacturer and painted with approved quality paint as per scope of work, detailed construction drawings, technical specifications and directions of Engineer-In-Charge. [Rate to include cost of all labour, tools, tackles etc. complete].
Supplying, fabricating and erecting structural steel canopy (including Canopy facia with 4mm th ACP,Led Company LogoACP Column clading4mm incl all singi work & ACM sheeting ) Supply, fabrication, erection and handing over of structural steel fabricated canopy including roof sheeting as per specification, Pre-coated Steel false ceiling system with powder coated finishes as per manufacturers instruction and specification, gutters, facia, flashings, Rain water pipes and gutter, painting, complete in all respects as per scope of work, detailed construction drawings, technical specification and directions of Engineer-in-charge. (Plan area shall be considered for measurement.)
Providing and fixing Al glazed framing Door:- Supply, transportaion, fixing in place the aluminium glazed framed door of approved make in the masonry wall as per the procedure laid down in the tender document at the locations specified by Engineer In Charge. [Rate to include all material, labour, tools, tackles, hire charges, water charges etc and all the necessary things that are required for completing the job in all respect .]
SECTION -VI : (ROAD & FORECOURT WORKS)
Providing and Construction of Rain Water Harvesting Pit including 40M Deep Bore well 150MM Dia with all Associated Works as per approved design drawings, scope of work, tender document and as per direction of EIC.
Supply & laying of perforated G.I. trays of following sizes as per technical specification.
150 mm wide
300 mm wide
600 mm wide
Supply & laying of HD PVC. Pipes buried for drainage/electrical work/other work.
RCC M-15 in DRIVEWAY (RATE including cost of 80 - 100 kg re-inforcement and shuttring)
PART-C Electricak Works
Design, supply, installation, testing & commissioning of Electrical distribution panel as per specifications & single line diagram (Drg. No. MNGL/PANEL/01) and APFC panel. (I)Emergency Panel Board for CNG Station 125 A
Supply, installation, testing and commissioning of Wall Mounted Lighting DB. Double door construction. Constructed with 2 mm sheet steel enclosure along with a housing to mount the entire board. With required hardware, making connections including providing cable glands, lugs, earthing & Painting etc. arrangement for termination of cable / wires, including 3 phase and neutral bus bars etc. complete in all respects as per the tender document, technical specification, drawings and direction of EIC.
(I) LDB - 1 (For Out Door Lighting)
(II) LDB - 2 (For Indoor Lighting)
(III) Wall mounted ACDB for UPS Incomer: one no DP MCB 63Amp with Ammeter(Rating-0-30Amp) and indication lamp. Out going: 03 nos. DP MCBs 3 Amp, 4 no.DP MCBs 16Amp and 2 nos.DP MCBs 6Amp
Supply, laying , testing and termination of PVC insulated & sheathed, 1100V grade, armoured ,Aluminium/copper conductor cable of follwing sizes & type in surface trench./on wall/structural surface/in G.I. Pipes/conduit as specified / required as per the tender document, technical specification, drawings and direction of EIC.
(I)4 x 35 mm2 YRY/2XFY
(II)4 x 25 mm2 YRY/2XFY
(III)4 x 6 mm2 YRY/2XFY
(IV)4 x 2.5 mm2 YRY/2XFY
(V)2 x 2.5 mm2 YRY/2XFY
(VI)1 x 1.5 mm2 PVC insulated green colour copper conductor single core wire
(VII)16 mm2 PVC insulated green colour copper conductor single core wire
(VIII)6mm2 single core copper cable
(IX)Crocodile Clamp
Supply, installation, testing & commissioning of Lighting poles of 8 M height as per the enclosed drg. equipped with light fittings of type MRX51 (Philips or equivalent) 250W and HPIT lamp complete with Plate earting , J.B. equipped with terminals for incoming/ outgoing cables and 2A, MCB, 4 x 2.5 mm2 YRY/2XFY armoured cable from juction box to fixture including civil foundation as per the tender document, technical specification, drawings and direction of EIC.
Supply, installation, testing & commissioning of LED Lighting poles of 8 M height as per the enclosed drg. equipped with light fittings of type MRX51 (Philips or equivalent) 250W and HPIT lamp complete with Plate earting , J.B. equipped with terminals for incoming/ outgoing cables and 2A, MCB, 4 x 2.5 mm2 YRY/2XFY armoured cable from juction box to fixture including civil foundation as per the tender document, technical specification, drawings and direction of EIC.
Supply, installation, testing & commissioning of canopy light with pole / bracket, flameproof fixture and control gear box, internal cable (4x2.5 mm2 YRY/2XFY) from fitting to junction / control gear box to flameproof fitting, mercury vapour lamp etc. including civil foundation with pipe inserts for cables and connecting work, with all material and labour as per specification, drawings and instruction of Engineer-in-charge. FLP Canopy light SP - 13, Fixture : Well glass FLPW - 1095 for 250 W HPMV lamp.
Supply & laying of Copper Strip (for earthing) of following sizes, clamped to wall/structure& laying in trenches (as reqd.) including termination at the required points by welding/nut bolts including all earthing material as per the tender document, technical specification, drawings and direction of EIC. (I) 25 x 3 mm
Supply & laying of GI Strip (for earthing) of following sizes, clamped to wall/structure& laying in trenches (as reqd.) including termination at the required points by welding/nut bolts including all earthing material as per technical specification & drawings. (I) 25 x6 mm
Construction of Copper earthpit with display board:- Construction of Earthpits as per the drawing using GI pipe medium (class-B) 3M long, Copper plate of 600x600x3 mm size including supply of all material required and testing of earth pits as per latest version of IS:3043, specification and drawing.
Construction of G.I. earthpit with display board:- Construction of Earthpits as per the drawing using GI pipe medium (class-B) 3M long, including supply of all material required and testing of earth pits as per latest version of IS:3043 & specification & drawing.
Installation / Erection accessries including brackets, cable marker, lugs, double copression cable glands, junction box etc. as required as per technical specification & drawings
Suppy, installation and commissioning of 3 KVA UPS:- a) 3 KVA, non-redundant, single, manufacturer's standard design UPS System suitable for input power supply voltage of 415V , +10%, -20%, Three phase and output voltage of 230V +- 1% single phase with 4 hours battery back-up (VRLA maintenance free 2.0V battery) and all interconnecting cables between UPS & Battery Bank,Stands for UPS and battery etc. 5 KVA UPS system comprising of 13KW rectifier/Charger and 200Ah, 2.0 volt per battery(VRLA type)
Supply, installation, testing and commissioning of Building Lighting and Power Plug Socket including concealed point wiring with havey duty PVC conduit earth wire,on/off switches etc as required as per technical specification & drawings.
(I) 6/16 Amp Power Socket with 20A MCB,Four in one(Make Seimens or Equi.)4 sq. mm Cu. Conductor PVC insulated point wiring.
(II) 20 Amp 3 Pin Industrial type socket with 20 Amp. SP MCB sheet steel enclosure with 4 sq. mm Cu. Conductor PVC insulated point wiring for air conditioner.
(III) FCS 31/211 make Philips or equivalent
(IV) TMC - 501/136
(VI) Wall Mounted Fan
(VII) Exhaust Fan(Size 300mm,Sweep)Industrial type
(VIII) Exhaust Fan(Size 300mm,Sweep)
PART-D Mechanical Work SECTION-I : (SS TUBE LAYING & TESTING)
Laying, testing and commissioning of SS tubes along with all fittings (ie, unions, reducers, elbows, Tees , front Ferrule, Back Ferrule, NRV etc.) (all free issue items) as per Technical Specification & Typical P & ID for type of CNG station and scope of work including handling, lifting, transportation from Company's Stores to CNG Stations
(I) ¾” OD X 0.095” min Wall thk. SS Tube (Refer TS Section III - A)
(II) ½” OD X 0.083” min Wall thk. SS Tube (Refer TS Section III - A)
Erection rates of following items (Refer TS Section III - A)
(I) Ball Valves ¾” Size
(II) Ball Valves ½” Size
(III) Ferrule Fittings ¾” (if to be changed)
(IV) Ferrule Fittings ½” (if to be changed)
Supply, laying, testing and commissioning of SS 304 Tubes along with isolation valves, reducers & fittings etc.as per Technical Specification, Typical schematic drg. for Ins. air line of CNG station and scope of work including handling, storage,lifting, transportation upto CNG stations. (Note:Total no.of ferrule fittings may be considered as one jointing ferrule at every 5.0 m)
(I) ½” OD X 0.035” min Wall thk. SS Tube (Refer TS Section III - A)
(II) SS Ball Valves ½” Size
(III) Reducer ½” x 1/4" Size
(IV) Equal Tee ½" Size
SECTION-B: (I) ERECTION OF MECH. EQUIPMENT
Handling (including lifting and transportation from Company's store to CNG stations) and erecting in position, the following equipment either on the foundation at Ground level or on roof at 3.5 m above ground level. Contractor's scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc. :Cascade 3000 L water capacity. Erection at + 3.5 m level (Refer TS Section III - B) and Dispensors (2 Nos)
SECTION-B : (II) UNLOADING, TRANSPORTAION & LOADING OF BOOSTER COMPRESSOR
Unloading from existing position (including dismantaling of connection, packaging of booster Compressor package), handling including lifting and transportation from CNG stations to Company's store,if required / erecting on civil foundation at or above ground level in other CNG station site if necessary. Contractor's scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, wire rope, gasket, nut bolts, etc. : 250 SCMH Hydraulic Booster Compressor (Refer TS Section III - B)
SECTION - C : (SUPPLY, ERECTION & COMMISSIONING OF MISCELLANEOUS ITEM)
Supply, erection & commissioning of following miscellaneous items as per technical specification and at locations (within the stations) as directed by EIC Fire fighting Equipments (Refer TS Section III - C)
(I) DCP -9 Kg
(II) CO2 – 4.5 Kg
(III) Sand Bucket Set (6 Nos. on each stand)
Note: The quantities given above against individual items are indicative and shall not be considered to be binding. The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge. The unit rate shall be operated to work out the final payment due to Contractor.
PART-E Automation Work
PLC Logic Modification
Supply, Instalation and Commissioning of RTU as per tender specifications
CAT6 cable supply,laying & installation cost including glanding an termination as per tender specification
2Cx2.5 Sqmm Aluminium Armoured cable Supply, Installation and Commissioning
3Cx2.5 Sqmm Aluminium Armoured cable Supply, Installation and Commissioning
Supply, Installation and Commissioning of 100 mm perforated aluminium cable tray with cover and clamp
Supply, Installation and commissioning of switches, repeaters, barriers etc. as per tender terms and conditions
Supply of Mandatory spares as per tender specifications
Archies Construction
NIRMAAN PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .