Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 CrAccepted-Finance | ₹14.9 Cr | L1 | Accepted-Finance Lowest rate found. |
| 2 | L2₹15.9 CrAccepted-Finance | ₹15.9 Cr | L2 | Accepted-Finance High rate found. |
| 3 | L3₹15.9 CrAccepted-Finance | ₹15.9 Cr | L3 | Accepted-Finance High rate found. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Document not submitted as per tender terms and condition. |
Tender Value
₹12.6 Cr
EMD Value
₹22.6 L
Closing Date
4 Oct 2023, 2:00 pmClosed
The Exe.,Engg., PWD, WD-I, Daman.
The Multi Office Complex, PWD, 2nd Floor, Near Moti Daman Market, Moti Daman.
Restoration and Renovation of the Secretariat Building (Front Portion) at Moti Daman.
2023_DAMAN_3080_1
Tender Notice No.69/01/2023-24
Open Tender
Civil Works - Buildings
540 days
Daman District.
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
The Exe.,Engg., PWD, WD-I, Daman.
₹22.6 L
The Exe.,Engg., PWD, WD-I, Daman.
28 Oct 2023
2 Sept 2023
4 Oct 2023
2 Sept 2023
4 Oct 2023
2 Sept 2023
13 Sept 2023
Amount
Civil work
CIVIL WORK : Excavation and Filling Works : Providing material and labour, machinery for Excavation of foundation/utilities upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff within the site for all lead, all lift/ depth anywhere from the site etc complete as directed by Engineer in charge. for all kind of soil.
Providing material and labour for Excavation of foundation/utilities from 1.5 mt to 3.0 mt depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in the site for all lead, all lift/ depth (excluding hard rock) anywhere from the site etc complete as directed by Engineer in charge. for all kind of soil.
Providing material and labour for Excavation of foundation/utilities from 3 mt to 5 mt depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in the site for all lead, all lift/ depth (excluding hard rock) anywhere from the site etc complete as directed by Engineer in charge. for all kind of soil.
Disposing off the un-used excavated earth for all lead and lift/ depth out side the site at non objectionable place as directed by Engineer in charge.
Filling available Excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each deposited layer by ramming and watering. (Ramping by manual or mechanical means)
Providing material and labour for Filling in plinth with coarse sand with CBR value higher than 8% under floors or base of foundation including watering ramming, consolidating and dressing etc complete as directed by Engineer in charge.
Providing material and labour for Filling in foundation, plinth and plot Filling with murram (brought from out side) CBR value higher than 8% in layers of 20cm. thickness including watering, ramming and consolidating etc complete as directed by Engineer in charge.
Providing and filling in Rubble in foundation, in plinth and for plinth protection, filling, with quarry spalls covering and leveling the surface in layers of 20 cm thickness stone/metals or stone chips, including watering, ramming well and consolidating each layer using minimum 100mm cut size stones. (Ramping by manual or mechanical means)
Dewatering in all sorts of soil and soft murram, hard Murram and boulders, Soft Rock, Hard Rock including removal of surface water, water from foundation, trenches and ground water as necessary to performed construction required by the contract in accordance with the specification.
PCC and RCC works : Providing material and labour for laying Plain cement concrete 1:3:6 (1- Cement : 3- Coarse sand : 6- crushed stone aggregates 20 mm nominal size) in Foundation, Plinth, Pavement, Road work including cost of formwork, compacting, finishing, curing etc complete for all level, all height/ depth as directed by engineer in charge.
Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8- hand broken stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing material and labour for laying in position batched and machine mixed design controlled cement concrete M25 from Below plinth & upto plinth Level produced in batch mix machine, using cement content as per approved design mix, including pumping of concrete to site of laying including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve work ability without impairing strength and durability as per direction of Engineer-in-charge. using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete work in Foundation, footings, base of columns, pavement, grade slab, roads and Mass concrete including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. excluding cost of reinforcement and removal of the same for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
Providing and laying in position Ready Mixed M25 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in laying in Columns, Fins, Pillars posts, Rectangular polygon in plan and struts all work upto plinth level including cost of admixtures in recommended proportions as per IS: 9103 as per direction of the EIC. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. and removal of form for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
Providing and laying in position Ready Mixed M300 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in laying in Columns, Fins, Pillars posts, Rectangular polygon in plan and struts all work above plinth and upto floor IV level including cost of admixtures in recommended proportions as per IS: 9103 as per direction of the EIC. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. and removal of form for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
Providing and laying in position Ready Mixed M300 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in Beams, Plinth beam, Girders, Lintels and Cantilever all work upto plinth level including cost of admixtures in recommended proportions as per IS: 9103 as per direction of the EIC. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. and removal of form for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge. Height of propping and centering below supporting floor to ceiling not exceeding 4.0 M.
Providing and laying in position Ready Mixed M25 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in Beams, Plinth beam, Girders, Lintels and Cantilever all work above plinth and upto floor IV level including cost of admixtures in recommended proportions as per IS: 9103 as per direction of the EIC. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. and removal of form for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge. Height of propping and centering below supporting floor to ceiling not exceeding 4.0 M.
Providing material and labour for laying in position batched and machine mixed design controlled cement concrete M25 from below plinth & upto Plinth level produced in batch mix machine, using cement content as per approved design mix, including pumping of concrete to site of laying including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve work ability without impairing strength and durability as per direction of Engineer-in-charge. using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete work in Slabs, landing, lintels, shelves, Balconies and Cantilever including cost of expose/fair finish Formwork including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. excluding cost of reinforcement. Height of propping and centering below supporting floor to ceiling not exceeding 4.0 M and removal of the same for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
Providing and laying in position Ready Mixed M25 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in Slabs, landing, lintels, shelves, Balconies and Cantilever all work above Plinth upto floor IV level including cost of admixtures in recommended proportions as per IS: 9103 as per direction of the EIC. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) including cost of expose/fair finish Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. and removal of form for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge. Height of propping and centering below supporting floor to ceiling not exceeding 4.0 M.
Providing and laying in position Ready Mixed M25 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in laying in Walls all work upto plinth level including cost of admixtures in recommended proportions as per IS: 9103 as per direction of the EIC. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. and removal of form for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
Providing and laying in position Ready Mixed M25 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in laying in Walls all work above plinth and upto floor IV level including cost of admixtures in recommended proportions as per IS: 9103 as per direction of the EIC. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. and removal of form for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
Providing and laying in position Ready Mixed M25 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in stair and landing all work upto floor IV level including cost of admixtures in recommended proportions as per IS: 9103 as per direction of the EIC. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. and removal of form for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
Rebaring, Expansion joint , Core Cutting Centering Etc : Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 mt. Between supporting floor two ceiling including temporary brick or stone pillars for supporting as required. (I) Height more than 6 mt & upto 8.0 mt.
Providing and Core cutting work in Stone/RCC/Brick structures of maximum 400mm depth upto 150mm Dia with required core-cutting wet drilling, fastener tools, labour and supervision etc complete.
Providing material and labour for fixing in position PVC pipe sleeves 75-160mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleeve shall be removed before water proofing or grouting (at rain water down take location).
Providing and fixing 150 mm wide Aluminum fluted strips 3.15 mm thick sheet covering over expansion joints with screws as per design.
Reinforcement and Steel works : Supplying, cutting, bending, binding and placing in position TMT Bar Fe 500D reinforcement in all diameter confirming to relevant I.S. standards as per ISS 2502 and IS 1786 including cost of binding with GI wires and placing in position complete upto floor two level including Providing anti corrosive treatment to HYSD/Fe 500D bars with FUSION BONDED EPOXY COATING (FBEC) confirming to IS13620:1993 at approved plant including testing of coating as per relevant IS, before bringing the coated bars on site including To & Fro transportation of bars for sending at plant site etc. complete, for HYSD bars. (Brands:SAIL, Jindal)
Extra for additional lift of reinforcing steel for all R.C.C. work above floor two level.
Providing and fixing M.S. round holding down or anchor bolts with nuts and washer plates complete.
Steel works: Providing material and labour for fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes & sizes with all leads & lifts using MS Rolled Steel Sections, ISMB, ISMC, UC, H-Section, Hollow sections, Tubular Sections, MS Plates, Chequered Plates, MS Pipes, Perforated Sheet, Flats, Bars, Angles, MS Sheet, Girder, Beam, cattle trap, deep threaded MS bolts. All confirming to latest relevant IS codes for the work of steel structures like staircases, railings, handrail, jali, gates, grills, bracing, platforms, brackets, monkey ladder, cattle trap, rungs, Roof canopy, fencing posts, M.S. Screen etc. including straightening, cutting, bending, bolting and welding the members including necessary scaffolding/ staging etc. complete and comprising of Profile Cutting, Smooth grinding/ machining of edges/ faces/ all welding joints; Necessary welding; Machine drilling of holes for joining/ anchoring; dry sanding, degrease (wet cleaning) & preparation of rust free surface manually or mechanically, metal putty to make the surface even and smooth. The Contractor shall prepare shop drawing as per GFC drawing and as per actual site condition and get approved before execution by EIC. (Standard measurements will be paid for as actual cut length used at site) .(Brand: Tata Steel, Jindal)
Masonry works : Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg/SqCm in foundation and plinth in Cement Mortar 1:5 (1- Cement : 5 -fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in superstructure above plinth level upto floor two level (B) Cement Mortar 1:5. (1- Cement : 5 -fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in superstructure Cement Mortar 1:5. (1- Cement : 5 -fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge. Second Floor
Providing material and labour for (i) Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in foundation, plinth and superstructure above plinth level upto floor two level, in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for (i) Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) a above plinth to three level in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.Second Floor
Providing and laying Sand base autoclaves aerated cement blocks masonry with 150/200/225/230/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge at all heights. (The payment of RCC band and reinforcement shall be made for separately).
Door Window, Facade works : Providing wood work in frames of doors, windows, louvers clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be included As per Drawing ). First class Burma teak wood as approved by architect or engineer in charge)
Providing and fixing Paneled and glazed Single / Double shutters for openable Doors,fixed Window & Made from 38mm thk 1st Class teak wood Planks As per Approved By architect & fixing with SS hinges of required size with necessary screws, & All Necessary hardware SS 316 handle, Stopers etc , all complete as per direction of Engineer-in-charge Cost including for Required Beading Putty, Middle Putty as per Drawing & also including Providing & ffixing of 5mm Glass As per Drawing. : Teak wood : 38mm thick shutter (type of wood BURMA TEAK as approved by architect or engineer in charge)
Providing and fixing of Top Mounted Manual Single Side Sliding door Made from 35mm Thk Flush door & Finish with approved 1mm thk.Laminate finish on both side. sliding top mounted Sliding Track Dorma make or as per approved Make Complete with all required Accessory, handle, stopers etc.
Providing and laying 120 cm x 60 cm Glossy/ MATT finished Vitrified Tiles 9 to 10mm thk. Flooring (Qutone, Simpolo, Nexion or equivalent brand) flooring over 20 mm (average) base of cement mortar 1:4 ( 1 cement: 4 coarse sand) on new surface of floor by adhesive material(Polymer Chemical adhesive: Laticrete 325) including finished with flush pointing & cleaning the surface and including filling the joints with Approved Epoxy Grout (Polymer Chemical adhesive: Laticrete 325) in 3-4 mm width and 10 mm Depth including cost of PVC Spacers, Rubbing, Cleaning and finishing the surface etc. complete.(Basic Rate of tiles Rs 1000/ sq Mt)
Providing and laying 120 cm x 60 cm Glossy/ MATT Vitrified Tiles Wall Dado (Qutone, Simpolo, Nexion or equivalent brand) 8 mm thick of approved shade in skirting, risers of steps and dado on 10 mm thick cement plaster 1:3 (1 Cement : 3 coarse sand) & Polymer Chemical adhesive , Laticrete 325 or equivalent and jointed with (Polymer Chemical adhesive: Laticrete 325) including filling the joints with in 3-4 mm width and10 mm Depth including cost of PVC Spacers, Rubbing, Cleaning and finishing the surface etc. complete.(Basic Rate of tiles Rs 1000/ sq Mt)
Providing and laying 60 cm x 60 cm Glossy/ MATT finished Vitrified Tiles Flooring (Qutone, Simpolo, Nexion or equivalent brand) flooring over 20 mm (average) base of cement mortar 1:4 ( 1 cement: 4 coarse sand) on new surface of floor by adhesive material including finished with flush pointing & cleaning the surface and including filling the joints with Approved Epoxy Grout (Polymer Chemical adhesive: Laticrete 325) in 3-4 mm width and10 mm Depth including cost of PVC Spacers, Rubbing, Cleaning and finishing the surface etc. complete.(Terrace Floor) (Basic Rate of tiles Rs 500/ sq Mt)
P & L 24n x 24" vitrified 8 m m thick tile flooring over 20 m m (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. complete for light shade
Extra for providing material and labour for Grouting the joints of any type of flooring tiles upto 8mm wide joints and in full depth, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade and approved make (0.10 kg of hardener and 0.20 kg of resin per kg), including filling/ grouting and finishing complete as per direction of Engineer-in-charge.
Providing & Fixing of Brass In-lay Patti In granite or any type Flooring (like vitrified, Marble granite Etc) As per Design & Directed By eng. In charge. fixing of Brass Flate bar size (20mm x 6 mm ,25mm x 6mm or 30mm x 6mm Or as per directed.) Complete fixing with required Cutting in corner with proper cross joint & Proper line level including Finishing & flush Grouting with floor Level.
Plaster, Paint and Ceiling works : Providing throating or plaster drip groove 10 x 10 MM and moulding to RCC Chhaja and horizontal surfaces.
Providing material and labour for fixing G.I. hexagonal chicken mesh of size 16mm x 24mm of 22 gauge at junction of concrete and brick work or between different materials after making "V" grove between two different material surface and filled with rich cement mortar and @ 100mm on each side of surfaces including necessary "U" nails/ screws/ washers with cleats for fixing, overlaps, curing, scaffolding etc complete for all floors/ all levels/ all heights/ all shapes as per direction of Engineer-in-charge.
Providing and applying 10mm thick cement plaster in single coat plastering on ceilings and Sofitt of stairs upto all levels/floors (i)Cement mortar 1:3 (1-cement:3-sand) including finishing with a floating coat of neat cement slurry, scaffolding, curing, finishing, making grooves, forming pattas etc. complete as directed by the Engineer-in-charge.
Providing and applying 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick/ AAC blocks walls for plastering upto all levels/floors and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand). Including scaffolding, curing, finishing, making grooves, forming pattas etc. complete as directed by the Engineer-in-charge.
Providing and applying 20mm thick sand faced cement plaster on walls upto all floors above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete. Including scaffolding, curing, finishing, making grooves, forming pattas etc. complete as directed by the Engineer-in-charge.
Providing 20 mm thick double coat mala cement plaster on exterior/ interior, brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including scaffolding curing etc. complete.
Providing & Applying 12 to 15 mm th. Plaster of Paris layers on wall plastered surface & surface of required or directed by Engg- in charge including hacking finishing smooth, with proper level & handed over a clean & neat condition complete. The finished surface should be smooth and in perfect level so as to avoid un evenness and ready to take on paint. complete the work should be done as per directed by engineer in charge.
Providing and applying Wall painting (two coats) with plastic emulsion paint of approved brand having VOC (Volatile Organic Compound) content and manufacture on undercoated wall surface to give an even shade including required scaffolding, thoroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.( make Asian, Berger, Dulex, Nerolac)
Providing and applying two coats of Birla (white cement based) or Asian (acrylic lapy- putty) or equivalent & two coats of primer of approved brand and manufacture on new wall surface to give an even shade including required scaffolding, thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.
Providing material and labour for Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete including required scaffolding. (make: Asian paint, Berger, Dulex, Nerolac)
Metal Paint: Providing and applying two coats of abduct cured modified epoxy marine paint of 150 micron each and 50 micron top coat of acrylic pu finish. Including surface preparation by dry abrasive blasting of 45 to 60 microns with cleaning and removal of all dirt, grease, varnish, paint or any other foreign matter, including thinner and all accessories. Sample to be approved before starting of the work by Architect/ EIC. Rate shall be inclusive of the cost of scaffolding. (Brands: Jotun)
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)
Waterproofing and Canopy : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/Sq.Mt. mixed with water proofing cement compound @ 0.253 kg/ Sq.Mt.. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/Sq.Mt. mixed with water proofing cement compound @ 0.126 kg/Sq.Mt.. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing cement vata (10 cm X 10 cm size) quarter round in Cement Mortar 1:1 including neat cement finishing, watering etc complete
Providing & Fixing of Tensile Canopy As per (Attached Immage) at FF cut out area Fabricating with (A) Providing material and labour for fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes & sizes with all leads & lifts using MS Rolled Steel Sections, ISMB, ISMC, UC, H-Section, Hollow sections, Tubular Sections, MS Plates, Chequered Plates, MS Pipes, Perforated Sheet, Flats, Bars, Angles, MS Sheet, Girder, Beam, cattle trap, deep threaded MS bolts. All confirming to latest relevant IS codes for the work of steel structures like railings, handrail, jali, gates, brackets, monkey ladder, Roof canopy, fencing posts, M.S. Screen etc. including straightening, cutting, bending, bolting and welding the members including necessary scaffolding/ staging etc. complete and comprising of Profile Cutting, Smooth grinding/ machining of edges/ faces/ all welding joints; Necessary welding; Machine drilling of holes for joining/ anchoring; dry sanding, degrease (wet cleaning) & preparation of rust free surface manually or mechanically, metal putty to make the surface even and smooth. The Contractor shall prepare shop drawing as per GFC drawing and as per actual site condition and get approved before execution by EIC. (Standard measurements will be paid for as actual cut length used at site) .(Brand: Tata Steel, Asian Jindal) (B) Supplying & Fixing of Supply of Tensile Fabric 750 gsm Made by Ferrari ( Made in France or Equalant ) including Cutting & Patterning as per shape , Welded with seaming machine,Handling & Installation at site with Accessories like Aluminum Extruded Section, Turn Buckle, Plate, Nut Bolt, Rod etc. made of S.S. 304 SDST Screw/washer etc. complete.
Plateforms / SS Railings : Constructing Sand witch Platform of 18 mm thick Polished Black Granite at top laid over 30 mm thick Kota stone slab flooring (15mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) fitting at bottom with cementing Materials / adhesives including making necessary grooves in walls including all labour material of approved quality incl. full molded round front edge molding/ flat molding fixed in wall & sandwitch partition and jointed with grey cement slurry including rubbing and polishing etc. complete as per drawing.(Basic Rate of ₹ 2500/Sq.M)
Providing and fixing stainless steel (Grade 316) Railing and baluster system of approved make stair railing, hand rail, bump rail, guard rail, with knock down system made of Hollow or solid secion i.e. tubes, square, flat, plates, bar etc with base plate Cover cap, finishing accessories, infilled holding brackets, fixing accessories etc. for any type of design, shape (plain/ curvature), size as per drawing. Railing shall be top mounted or side/ wall mounted. Railing shall be fixed with SS 316 grade anchor fastner of required size and as per fixing position of approved make. No Weilding OR Fabrication shall be allowed at site. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Sample shall be approved before execution. Contractor shall arrange mock up of railing system (2 or 3 no) in required length as directed by Architect. Contractor shall protect railing system uptill handling over the project.
Providing and fixing Free standing, frameless Glass Railing Systems a classically modern / the Traditional look wet-glaze installation method is a tried and true process that firmly secures the glass into the SS base shoe. Mount the shoe directly to the floor or side mount as a facia-mount.& Top Horizonatal Flush Chennel Tube & fixed 12mm thk.toughened Glass between top & base rail with stainless steel (Grade 316) Railing system of approved make & Top Slim Rail with hollow section tubes, square, Round, Rectangle etc with base plate Cover cap, finishing accessories, size as per drawing. Railing shall be top mounted or side/ wall mounted. Railing shall be fixed with SS 316 grade anchor fastner of required size and as per fixing position of approved make. No Weilding OR Fabrication shall be allowed at site. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Sample shall be approved before execution. Contractor shall arrange mock up of railing system (2 or 3 no) in required length as directed by Architect. Contractor shall protect railing system uptill handling over the project.
GRC & Supporting structure of GRC : Providing and Fixing Automatic Machine cut GRC Cornice "A" having compressive strength of 35-55 MPA and Flexural Strength of 6-16 MPA ,Dry density 1.8 to 2.2T/M³ ,Glass (Alkali Resistant 2% -5% as per approved design,& colour White Cement Base/Grey cement Base , Finish Front Side Smooth As per Directed by Architect and Engineer in-Charge including Packing, Transporting, Unloading, fixing at Site etc.complete.(Thickness not less than 25mm thk)
Providing and Fixing Automatic Machine cut GRC Cornice "B" having compressive strength of 35-55 MPA and Flexural Strength of 6-16 MPA ,Dry density 1.8 to 2.2T/M³ ,Glass (Alkali Resistant 2% -5% as per approved design,& colour White Cement Base/Grey cement Base , Finish Front Side Smooth As per Directed by Architect and Engineer in-Charge including Packing, Transporting, Unloading, fixing at Site etc.complete.(Thickness not less than 25mm thk)
Providing and Fixing Automatic Machine cut GRC Cornice "C" having compressive strength of 35-55 MPA and Flexural Strength of 6-16 MPA ,Dry density 1.8 to 2.2T/M³ ,Glass (Alkali Resistant 2% -5% as per approved design,& colour White Cement Base/Grey cement Base , Finish Front Side Smooth As per Directed by Architect and Engineer in-Charge including Packing, Transporting, Unloading, fixing at Site etc.complete.(Thickness not less than 25mm thk)
Providing and Fixing Automatic Machine cut GRC Square Cornrer Columns having compressive strength of 35-55 MPA and Flexural Strength of 6-16 MPA ,Dry density 1.8 to 2.2T/M³ ,Glass (Alkali Resistant 2% -5% as per approved design,& colour White Cement Base/Grey cement Base , Finish Front Side Smooth As per Directed by Architect and Engineer in-Charge including Packing, Transporting, Unloading, fixing at Site etc.complete.(Thickness not less than 25mm thk)
Providing and Fixing Automatic Machine cut GRC Round Columns (Small 7Mt.) having compressive strength of 35-55 MPA and Flexural Strength of 6-16 MPA ,Dry density 1.8 to 2.2T/M³ ,Glass (Alkali Resistant 2% -5% as per approved design,& colour White Cement Base/Grey cement Base , Finish Front Side Smooth As per Directed by Architect and Engineer in-Charge including Packing, Transporting, Unloading, fixing at Site etc.complete.(Thickness not less than 25mm thk)
Providing and Fixing Automatic Machine cut GRC Round Columns (Big 8Mt.) having compressive strength of 35-55 MPA and Flexural Strength of 6-16 MPA ,Dry density 1.8 to 2.2T/M³ ,Glass (Alkali Resistant 2% -5% as per approved design,& colour White Cement Base/Grey cement Base , Finish Front Side Smooth As per Directed by Architect and Engineer in-Charge including Packing, Transporting, Unloading, fixing at Site etc.complete.(Thickness not less than 25mm thk)
Providing and Fixing GRC Carving Motif having compressive strength of 35-55 MPA and Flexural Strength of 6-16 MPA ,Dry density 1.8 to 2.2T/M³ ,Glass (Alkali Resistant 2% -5% as per approved design,& colour White Cement Base/Grey cement Base , Finish Front Side Smooth As per Directed by Architect and Engineer in-Charge including Packing, Transporting, Unloading, fixing at Site etc.complete.(Thickness not less than 25mm thk)
Providing and Fixing GRC Window Surrounding having compressive strength of 35-55 MPA and Flexural Strength of 6-16 MPA ,Dry density 1.8 to 2.2T/M³ ,Glass (Alkali Resistant 2% -5% as per approved design,& colour White Cement Base/Grey cement Base , Finish Front Side Smooth As per Directed by Architect and Engineer in-Charge including Packing, Transporting, Unloading, fixing at Site etc.complete.(Thickness not less than 25mm thk)
Providing and Fixing GRC Screens having compressive strength of 35-55 MPA and Flexural Strength of 6-16 MPA ,Dry density 1.8 to 2.2T/M³ ,Glass (Alkali Resistant 2% -5% as per approved design,& colour White Cement Base/Grey cement Base , Finish Front Side Smooth As per Directed by Architect and Engineer in-Charge including Packing, Transporting, Unloading, fixing at Site etc.complete.(Thickness not less than 25mm thk)
Providing and Fixing Fabricated Structural Supporting Structure for GRC Works as per approved design by Architect and Engineer in-Charge including fabricating, transporting, painting etc. complete.
Providing and Fixing Scaffoling as working platform for working at height with approved grade of Steel including cutting, fabricating, assembling and removal from site after completion of work etc. complete.
Roof Work : Providing and fixing new well seasoned C.P teak wood members for decorative truss like purlines, Tie beam, Posts , ridge etc make the same original design, size and pattern including all mouldings, rebating, holdfasts and any other necessary fittings .
Mangalore Tiles : Providing & fixing on roof pressed clay tile (Mangalore tile with class "AA" tiles) of 20 mm nominal thickness and of approved size and as per approved pattern on wooden batten frame work complete including ridge batten etc. all complete.
Ridge Tiles: Providing & fixing Mangalore tile ridge & hip tiles of class 'AA' painting with coloured cement mortar & curing etc complete.
Al Sleet : Providing and fixing zero punture alluminium sheet in such a way that alluminium sheet fixed between horizontal battens and vertical battens,plain alluminium sheet on including topof wooden planks and including ss screws, SS coils steakers and plain aluminium sheet.
Providing and fixing C P. Teak wood battens of size 50mm X 25min for Mangalore tile roof work including providing 1 coat of Black Japan on all sides, fixing with SS screws (304) or brass screws as directed by the MC/Architect etc. complete.
Wacker on Manglore Tiles : Application of high quality wacker SMK 1311 Solvent free silicone water repellent coating impregnating on the Monglore tiles by spray. The dilution with water should be done in a ratio of 1:14 ie I part od solution and 14 parts of wacker 1311 solution. The dilution should be applied in 2 or 3coats, wet on wet surface. The dilution should be applied either with brush or by spmy. The application should be done afler siuface is prepared for it. The contractor is to adhere to manufacturer’s specification.
Providing and fixing T.W boarding 25 mm thick well seasoned CP teakwood without knots or cracks, in design plank. ( Basic rate of wooden planks=4275/ CFT)
Providing & laying the dungry cloth over the entire surface of wooden boarding having the hot bitumen coating below to stick the dungry cloth & then spread the cloth. Post spreading the cloth the hot bitumen to be applied using a long brush with a long stick. Application to be done uniformly over the entire surface.
Providing & fixing Design eves boards 250-300 mm wide and 25 mm thick well seasoned CP teak wood without knots or cracks ,in design boards as directed by architect ,etc .complete.
Providing & fixing Plain eves boards 250-300 mm wide and 25 mm thick well seasoned CP teak wood without knots or cracks ,in design matching to existing eves boards as directed by architect ,etc .complete.
Providing & laying lead flashing of beat quality of minimum 400 or more width as required and 1.5 mm thick in rolled section or in strips which ever is available in market for valley gutters and in both roof and parapate including proper fixing ,cutting sheet with machinery in required width ,length and shape etc .complete ,the item to include providing for overlap joints incase of the total width of valley gutter is more than the width of the available lead sheet.
Providing and laying water proofing treatment Terrace Area by BRICK BATT LAYING (a). Applying neat cement slurry 2.75 kg/m2 of cement admixed with water proofing compound after cleaning the surface. (b). Layingof bricks bats of 25 to75 mm size in CM 1:5 (1 cement : 5 course sand) admixed with water proofing compound over 20mm thick layer of cement mortar 1:5 to required slop including rounding of juctions of walls and slab with spacing not more than 30mm.(c) After two days of proper curing applying a second coat of cement slurry and cured for another two days. (d) Finishing the surface with 20mm thick cm 1:4 and cured for two days with required levels and slope including rounding of juctions at walls,curing etc.As directed and specified.Water pond should be carried out for a period of Seven days as directed by EIC.cement slurry admixed with approved water proofing compound (FosRoc / BASF / Dr. Fixit).
ELECTRICAL WORK : Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) - Three phase 12 way SS Double door for horizontal single phase outgoing
Miniature circuit breaker single pole 6A to 32A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark - SP MCB
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 6 to 32 Amp. - DP MCB
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 40Amp. - DP MCB
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 6 to 32 Amp.
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 40 Amp.
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 63 Amp.
Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed 25 Amps.DP
Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed 63 Amps.DP
Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB.
Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating up to 125A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only with Sheet metal Enclosure
Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating up to 250A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only with Sheet metal Enclosure
Providing and erecting metallic vitrified danger notice board for MEDIUM VOLTAGE installation to be erected as per IS.
Providing and erecting metallic vitrified danger notice board for HIGH VOLTAGE installation to be erected as per IS.
Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as required with necessary connection erected as directed.
Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - flush / surface mounted double door (IP54) fitted with insulated copper busbar, isolated neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986,IP-54 suitable for 250 AMP TPN MCCB + RCCB as incomer and three phase outgoing as per following .(The DBs should be used of same company of MCB to be used) (D)12 way outgoing
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (c)63 Amp.
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(a) 4 core 2.5 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(a-1) 4 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(B) 4 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (A) 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (H) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core)
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 4 core 4 Sq. mm / 4 core 2.5 Sq. mm (4 lux and 1 Earthing)
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (B) 4 core 6 Sq. mm (4 lux and 1 Earthing)
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (D) 4 core 16 Sq. mm (4 lux and 1 Earthing)
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 3 & 1/2 core 25 Sq. mm (3 lux and 1 Earthing)
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (B) 3 & 1/2 core 35/50 Sq. mm (3 lux and 1 Earthing)
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 3 & 1/2 core 120 Sq. mm (3 lux and 1 Earthing)
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (F) 3 & 1/2 core 150 Sq. mm (3 lux and 1 Earthing)
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (G) 3 & 1/2 core 185 Sq. mm (3 lux and 1 Earthing)
Supplying & laying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water having following size of dimensions and No of compartments (W x D x T) : 150mm x 38mm x 1.6mm with Three Compartments
Providing and fixing approved make 'Cross over Junction' for ladder type cable tray. Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge..150 X 100 X 1.6 mm Thick
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge and laying/erecting as per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D x T) Cat-III 50mm x 38mm x 1.6 mm with One Compartments
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge and laying/erecting as per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D T) Cat-III 100mm x 38mm x 1.6 mm with One Compartments
Providing and fixing approved make 'Cross over Junction' for ladder type cable tray. Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge..400 X 100 X 1.6 mm Thick
Supplying and erecting approved make GRP Ladder type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections - Polyester Resin System, Glass Content : 55 – 60 % - Thickness- Rung Sq. Hollow Tube 25mm x 25mm - Fixing of Rung to Side Rail with Thermoplastic Pin & Epoxy Adhesive, Assembly Single Stroke 3 Mtr. Length- Rung Spacing – 300mm - Length of Tray: 3000mm- Support Span – 2500mm, Deflection L/200 or < 10mm whichever is less - Specification Followed NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Oxygen Index – Minimum 30% as per ASTM D 2863 Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 (A) Width 150 mm, Side Member “C” Section : 75 x 25 x 25mm with 4mm Thickness, Loading 30Kg./Mtr. With Concentrated Load 70Kg. at center of the span
Supplying and erecting approved make GRP Ladder type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections - Polyester Resin System, Glass Content : 55 – 60 % - Thickness- Rung Sq. Hollow Tube 25mm x 25mm - Fixing of Rung to Side Rail with Thermoplastic Pin & Epoxy Adhesive, Assembly Single Stroke 3 Mtr. Length- Rung Spacing – 300mm - Length of Tray: 3000mm- Support Span – 2500mm, Deflection L/200 or < 10mm whichever is less - Specification Followed NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Oxygen Index – Minimum 30% as per ASTM D 2863 Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 (B) Width 300 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 60Kg./Mtr. With Concentrated Load 70Kg. at center of the span
Supplying and erecting approved make GRP Ladder type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections - Polyester Resin System, Glass Content : 55 – 60 % - Thickness- Rung Sq. Hollow Tube 25mm x 25mm - Fixing of Rung to Side Rail with Thermoplastic Pin & Epoxy Adhesive, Assembly Single Stroke 3 Mtr. Length- Rung Spacing – 300mm - Length of Tray: 3000mm- Support Span – 2500mm, Deflection L/200 or < 10mm whichever is less - Specification Followed NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Oxygen Index – Minimum 30% as per ASTM D 2863 Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 (C) Width 450 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 75Kg./Mtr. With Concentrated Load 70Kg. at center of the span
Supplying and erecting approved make GRP Ladder type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections - Polyester Resin System, Glass Content : 55 – 60 % - Thickness- Rung Sq. Hollow Tube 25mm x 25mm - Fixing of Rung to Side Rail with Thermoplastic Pin & Epoxy Adhesive, Assembly Single Stroke 3 Mtr. Length- Rung Spacing – 300mm - Length of Tray: 3000mm- Support Span – 2500mm, Deflection L/200 or < 10mm whichever is less - Specification Followed NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Oxygen Index – Minimum 30% as per ASTM D 2863 Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 (D) Width 600 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 90Kg./Mtr. With Concentrated Load 70Kg. at center of the span
Supplying and erecting approved make GRP Perforated type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections- Polyester Resin System, Glass Content : 55 – 60 % - - Standard Length : 3000mm- Support Span – 1500mm, Deflection L/200 - Specification NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 Supplying and erecting approved make GRP Perforated type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections- Polyester Resin System, Glass Content : 55 – 60 % - - Standard Length : 3000mm- Support Span – 1500mm, Deflection L/200 - Specification NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 (D) Width - 150mm, Pultruded “C” Channel with 30mm Sides 3mm Thickness, Loading 15 Kg./Mtr.
Supplying and erecting approved make GRP Perforated type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections- Polyester Resin System, Glass Content : 55 – 60 % - - Standard Length : 3000mm- Support Span – 1500mm, Deflection L/200 - Specification NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 (E) Width - 200mm, Pultruded “C” Channel with 40mm Sides 4mm Thickness, Loading 25 Kg./Mtr.
Supplying and erecting approved make GRP Perforated type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections- Polyester Resin System, Glass Content : 55 – 60 % - - Standard Length : 3000mm- Support Span – 1500mm, Deflection L/200 - Specification NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 (F) Width - 300mm, Pultruded “C” Channel with 50mm Sides 4mm Thickness, Loading 30 Kg./Mtr.
Fabrication : Supplying , fabricating and installation of various sizes clamps for cable tray supports using available M.S. sections & rod as per drawings or instructions of engineer in charge or consultant including applying zinc chromate yellow oxide and two to three coats of required enamel paints with anchor fasteners etc.
HEAT / FIRE RESISTANT COATING OF CABLE Supply and application of intumescent based coating on cables/ cable tray using CP 678 firestop cable coating of HILTI make or equivalent. The coating shall have a density in the range of 1.2 to 1.4 Kg/ L. The coating shall be non-toxic, asbestos and halogen free and shall have good mechanical strength. The coating shall comply with IEC 332 part 3 (1992).
Point wiring for Light Point / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.with medium class Rigid PVC pipe and accessories
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size in (a) with medium class Rigid PVC pipe and accessories Wire : (a) 2 wire 1.5 sq. mm
Additional Wire : Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size in (a) with medium class Rigid PVC pipe and accessories Wire : (b) 2 wire 2.5 sq. mm
Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling, complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling ,complete with 6A Modular type switches and following type of accessories erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling complete with 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted and accessories with earth continuity of following type erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling with following type accessories
Do - As - Above but for 6 A x 5 pin 250 Volt switched socket outlet point at convenient location. ( Plug & Switch can be together or at different location )
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [II] For 6/16A Plug with 2-2.5 sq.mm Cu. Wire (a) with medium class Rigid PVC pipe and accessories
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [III] For 16A Plug with 2-4 sq.mm Cu. Wire (a) with medium class Rigid PVC pipe and accessories
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 32 mm rigid PVC pipe of 1.6-1.8 mm thickness
Supplying & erecting Electronic Type Cordless Call Bell erected on PVC/Metal board having portable bell push working on D.C. & bell on 230V A.C. supply with cells / battery
Computer : Power Plugs 1 no. universal plug-switch combined + 1 Nos swithc for Below table 2 nos. 6A 5 pin Plug as below Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling with following type accessories Cat. III + Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [I] For 6A Plug with 2-1.5 sq.mm Cu. Wire (Car.iii) + [II] For 16A Plug with 2-2.5 sq.mm Cu. Wire (Car.iii)
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with following sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size : 4 wire 4 sq. mm
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with following sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size : 4 wire 6 sq. mm
Supply, Installation, Testing and Commissioning of suitable sweep, BEE 5 Star rated, Ceiling fan with Brush Less Direct Current (BLDC) permanent ferrite magnet Motor, class of insulation: B, Rust free 3 nos.Aluminium blades, 2 nos. canopies, shackle kit with earthing provision, copper winding, Power factor not < 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM,230v (tolerance as per IS : 374-2019), THD < 10%, with remote unit for Speed Control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (Max.), suitable for 140 to 285 Voltage and rectifier circuit with surge, over current and overload protection , 50 Hz, Single phase AC Supply, earthing etc. Complete as required.[ Make shall be approved by Engineer in Charge] 1200MM
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/ O.20, 3 core flexible wire with earthing.
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM [C] 380 mm dia 1400 RPM
Supply,installation, testing and commisioning of Recccesed light fixtures suitable for Tech Zone ceiling size of 150wide x 1200mm long LED Tube light (28W) with Micro Prismatic Diffuser,4kv SPD Matt Steel Grey Extruded Aluminum Body with system luman output minimum 2800 lm. Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Internal light fixtures of 1200mm long LED Tube light (20W) with 110LPW white color Aluminum extruded body and milky white diffuser.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Recessed Mounted 18W LED down light with White Aluminum dia cast , powder coated housing, reflector, PMMA Deep Down LG7 Diffuser cover with LED lamp and driver.LUMEN EFFICACY >110lm/w, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Recessed Mounted 10W LED down light with White Aluminum dia cast, powder coated housing, reflector, PMMA Deep Down LG7 Diffuser with LED lamp and driver.LUMEN EFFICACY >90lm/W / 110lm/W, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of 600x600mm LED Panel Light of 42W LED Lamp White CRCA Luminaire Body and Micro prismatic diffuser, LUMEN EFFICACY > 120lm/w, PF >0.90, THD <20%,SPD 4kv CCT 6000K, powder coated housing, reflector, Diffuced PC cover with LED Panel and driver.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Recessed Mounted ( meter long 20W/Mtr LED Profile light with Aluminium die cast construction, with Micro prisamatic diffuser . LED lamp and driver.PF >0.90.THD<20 %, Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of 4W/Mtr LED strip light with indoor application with All require accessiers and Drivers LUMEN EFFICACY >90lm/W, PF >0.90, THD <20%, CCT 4000K, Make : Trilux, Wipro, Philips
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. (c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e independent Earthing in normal soil. Length of Pipe : 3.00 mtrs Back filling Compound :2 nos Bags of 25 Kg.
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. (b)For Electrical installation up to 11 KV in normal soil. Length of Pipe : 2.00 mtrs Back filling Compound :1 no. Bag of 25 Kg.
Supplying & erecting of Conventional Lightening arrestor with Test loop and Counter as per IS standard
Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness .
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. (8) Modem Jack for Computer Open RJ-45 - cat-III
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. (3) Two Pin/RJ-11 Telephone Socket for One Gong Bell - cat-iii
Supplying & erecting push button type telephone instrument having speaker phone Caller ID & speaker phone with one touch memory (min.6 nos.)& 99 memories with display system (a) Single line BEETEL/panasonic or equivalent make
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction : [C] CAT - 6
Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections. (b1) Armoured [Jelly Filled] - 10 Pair
Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections. (b2) Armoured [Jelly Filled] - 20 Pair
Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections. (b3) Armoured [Jelly Filled] - 50 Pair
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness .
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. RG-6 Cable
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. RG-11 Cable
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. for (4) TV Co-axial Socket outlet
Supply, Installation, Testing and Commissioning of 5 Megapixel HD Dome Camera, HD1080p,1/2.7" CMOS, 24 pcs LEDs, 20m IR, Indoor IR Eyeball, ICR, 0.1 Lux/F1.2, 12 VDC, Smart IR, DNR, DWDR, 3.6mm lens, 4 IN 1
Supply, Installation, Testing & Commissioning of 2 Megapixel HD Dome Camera, HD1080p,1/2.7" CMOS, 24 pcs LEDs, 20m IR, Outdoor IR Bullet, ICR, 0.1 Lux/F1.2, 12 VDC, Smart IR, DNR, DWDR, IP66, 3.6mm lens, 4 IN 1 OUTPUT
Supply, Installation, Testing and Commissioning of 16-Channel Digital Video Recorder recording with 4TB HDD with all require installation and integration with all camera system, 16 Turbo HD input, 16-ch video&1-ch audio input, 2 SATA interface, 1280×720P: 25(P)/30(N) fps/ch, 380 1U caseW/O HDD with all require software
Installation, Testing and Commissioning of 32" Full HD LED monitor with Power Cord complete as required & necessary video cards complete as required (if required). Make - Sony, Samsung, Philips
Supply, Installation, Testing and Commissioning Power Supply for Camera
Supplying & Laying 24U Wall mounted Rack for the CCTV DVR installation with all require power ports fixed wall rack has a tempered glass door and removable locking side panels. Included with this rack is one set of fully adjustable cage-nut style rails and removable top and bottom cable slot panels, allowing easy installation of CAT5 or fiber optic cables.
Supplying & Laying 24 port rack mounted switch for the following specfiication Approved by cUL Listed, CE, EN 60950, FCC Part 15 Class A, TUV, UL Listed 24 10/100/1000Mbps RJ45 ports
Bio metric Access Control with face detection and having a memory storage of 35 days for 200 members
Supplying & erecting recess speaker with 5W rated input power 3.3 K. Ohms / 3W impedance, 100 - 10000 Hz frequency response with 6 inch dia. cone type 8 ohms speakers duly fitted in ABS plastic cabinet of colour match with wall or ceiling of following size. (a)Round Shaped, 230mm dia. Speaker Make - JBL, Harman, Yamaha
Supplying & erecting of Amplifier having following specification: Power Output :400W (RMS) (300W Max.) inputs : 6 Misc. & 2 Aux. frequency Response :50-1500HZ I3db Tone Controls :Cut & Boost type LED Meter :5 LED Arrays The amplifier suitable to operate 240V A.C.& 24volt D.C. (Battery) with automatic changeover from AC to Battery operation, duly protected by wrong Battery Polarity connections.Make - JBL, Harman, Yamaha
SITC of Conference System Central Mixer Amplifier facilitates conduct of meetings system designed to handle a wide variety of conference application .Central Amplifier has a digital recorder for recording the proceedings. Also it can playback the pre-recorded messages. Switchable send/return facility in Central Amplifier. Three Mic inputs and one Aux input for various user applications.50W PA Amplifier for adequate sound reinforcement.Headphone output provided in Central Amplifier for monitoring purposes. AC Mains & 24V DC operation.Central Amplifier is 19" rack mountable. Line Output 2, Power Output :- 50W RMS at 2% THD, 90W Max, Inputs:-3×Mic, 1×Aux, Frequency Response:- 60-14,000Hz ,S/N Ratio:- >60dB ,Tone Controls Bass, Treble,Speaker Output :- 4Ω, 8Ω, 16Ω, 70V & 100V as directed by engineer in charge
Supplying & erecting, of 2cx1.5 Sq. mm Cu Flexible Speaker cable
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector having IS-11360-1985 or BS 5446 Part I-1977 & Part VII –1985 (VdS approved) or NFPA72 ( UL/ULC/FM approved) with Latest ammendment complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment complete as required.
Supplying, installation, testing & commissioning of addressable manual call point having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment complete as required.
Supplying, installation, testing & commissioning of repeater panel having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required
Supply and fixing of 90 mins Battery back-up Exit Light fixtures with ceiling mount brackets and chain including all required accessories.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. (A)Speaker cable Single pair, 2-core, 1.5 sqmm
Supply installation testing and commissioning High Speed quick power charging station for Electrical vehicle as per standard voltage rating with 40A FP MCB and 2 Nos 6A power plugs, it should have digital screen and all parameter recorders.
Supply installation testing and commissioning of roof top solar system with 20 years performance warranty , cost include high efficiency solar SPV module, require earthing, Lightening arrestor, supporting fabrication hot dip GI structure with paint, all require wiring, ACDB DCDB, Solar power meter, and inverter as require with consideration of 1-Year DLP
AMC : Comprehensive AMC with performance gurantee for the Installed Solar Panel for 1st Year after DLP (period 3% of Inititla Cost) Cleaning of panels, Preventive maitnancne, Checking of all wire connection, Inverter, Monthly Report to AMC etc
AMC : Comprehensive AMC with [erformance gurantee for the Installed Solar Panel for 2nd Year after DLP (period 3.5% of Inititla Cost) Cleaning of panels, Preventive maitnancne, Checking of all wire connection, Inverter, Monthly Report to AMC etc
AMC : Comprehensive AMC with [erformance gurantee for the Installed Solar Panel for 3rd Year after DLP (period 4% of Inititla Cost) Cleaning of panels, Preventive maitnancne, Checking of all wire connection, Inverter, Monthly Report to AMC etc
Supplyinhg certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 1st Year Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Supplyinhg certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 2nd Year Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Supplyinhg certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 3rd Year Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc.
Supplyinhg certified, trained 2+Year Experienced Electrician man-power for the Monthly Basis for 4th Year Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc.
Comprehensive AMC for the Full Electrical System for 1st Year after DLP (period 3% of Inititla Cost) - Performance bank gurantee to be submit at time of complwetion of work Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Comprehensive AMC for the Full Electrical System for 2nd Year after DLP (period 3.5% of Inititla Cost) - Performance bank gurantee to be submit at time of complwetion of work Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Comprehensive AMC for the Full Electrical System for 3rd Year after DLP (period 4% of Inititla Cost) - Performance bank gurantee to be submit at time of complwetion of work Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
HVAC WORK : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) 16 HP (GF)
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) (GF 06 Nos + 06 nos FF Total 12 Nos) 24 HP
VRF Indoor Units Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System (D) 1.6 TR ( First Floor )
VRF Indoor Units Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System (E) 2.0 TR (GF 5 + FF 2 = 07 Nos )
VRF Indoor Units Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System (F) 2.4 TR (GF 1 + FF 1 = 02)
VRF Indoor Units Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System (H) 3.2 TR (GF 5 + FF 4 = 09)
VRF Indoor Units Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System (J) 4.0 TR (GF 4 + FF 8 = 12)
VRF Indoor Units Supply of Ceiling mounted reguar split Unit with Panel, Filter.Supply, installation, testing and commissioning of following minimum capacity VRV High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with noise level maximum 60 dB @min 400 cfm /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (E) 2.0 TR (FF)
VRF Indoor Units Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. High Static Ductable units (minimum 110 pascal external static pressure) (C) 8.1 TR (GF)
Precision AC Units Microprocessor based Precision units with R407 refrigerant ,Scroll compressor with built in temprature control Low airflow diffrential alram switch ,Direct driven double inlet cenrifugal fans Treated Fresh Air Unit Supply Of Ceiling Suspended Treated Fresh Air Unit As Per Specs (VRF Based)(Make : VTS / Edgetech / Flaktwood) Frame structure: Extruded profile Al. anodized with thermal break.Panels: Double skin panels 48 mm thick +- 2 puff.Inner skin: 20G GI plain and Outer skin: 24G GI pre-coated Skid: GI epoxy coatedDrain pan: 1.2 mm thick SS304 with 25mm Nitrile rubber sandwiched. Provide 40 mm SS threaded drain nipple.Dampers: Al. anodized low leakage aerofoil.Shaft to accept motorized actuators.Filter section: With MERV-13 filters, Prefilter ,access doors filters in extruded al. box type frames with gasket arrangements around filter frames. This should include one set of commissioning filters. Coil Section: Cu coils with hydrophilic coated al. fins,8 Row coilFan section: Plug Fans with access doors on both sides, inspection windows, limit switch to shut off fan on door opening. Flexible connectors: Non flammable, weather and fungus proof Vibration Isolators: For fans and mounting arrangements - Rust resistant spring Drive: EFF-1 motor with Starter Panel & cabling, wireless remote, Non Polarised NO-NC contacts for tripping on signal from Fire Dampers/Fire Alarm Panel with all required accessories should also be included in the quoted Price. The maximum face velocity shall be 2.5 m/s. The port for manometers shall also be provided to monitor the pressure drop individually across the pre-filter for each TFAU. The filter section shall be so arranged that they can be easily removed for cleaning. Heavy duct flexible double layer canvas connection shall be provided at the outlet of TFAU Fan. The minimum external fan static shall be as per technical specifications.
TFAU's should be suitable for Fan velocity not exceeding 1800 FPM, coil Face Velocity not exceeding 500 FPM and Fan RPM not exceeding 1000 RPM. TFAUs with suitable VFD & bypass facility with separate starter panel. Fan efficiency > 70% & complete as per specifications & drawings. TFAU's should be suitable for Multikit connection with VRF Units. (GF 01+ ff 01= 2 nos ) of 3750 CFM/25 TR - 55mm wg Total static pressure
Toilet Ventilation Fans Supply Of Ceiling Suspended Ventilation Fan Unit As Per Specs (Make : Airflow / Nicotra / Greenheck) Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 1050 CFM / 20MM ESP - Exhaust Air Fan
Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 750 CFM / 20MM ESP - Fresh Air Fan
Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 650 CFM / 20MM ESP - Exhaust Air Fan
Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 500 CFM / 20MM ESP - Fresh Air Fan
providing and erecting BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified
Central Remote Controller Supply Of OEM make Central Remote Controller (Make : Mitsubishi Heavy / O General / Mitsubishi Electric) Central Remote Controller Monitoring & control of temperature of each Area & Units ON/OFF control for each Area & Units Weekly scheduling for each Area & Units Overriding of control function of individual control units Scheduling & historical data storage of conditions as per requirement LCD Display Panel To be integrated with Fire Panel To be installed at Reception Area. And should be opearted from PC It should be compatible with latest microsoft version. *In case the no. IDUs / ODUs is beyond the capability of a single CRC, then the rate quoted here should include cost of add-on modules / multiple CRCs / cabling.
Starter Panel For TFA Supply Of Starter Panel for TFA Factory supplied control & operating panel with required MCB, protection housed in weatherproof MS painted enclouser, near to TFA Electrical panel will be complete with necessary starters, fuses, switches, timers, overload relays, contactors, push buttons and indicating lamps, single phasing preventing PREVENTOR etc.
Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of VRF Outdoor Unit Also it should include first oil & gas charge & commissioning etc. complete 16 HP
Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of VRF Outdoor Unit Also it should include first oil & gas charge & commissioning etc. complete 24 HP
Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of Regular Cassette Units Indoor with accessaries like required Cassette panel, support plate, , Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. ( First Floor ) 1.6 TR
Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of Regular Cassette Units Indoor with accessaries like required Cassette panel, support plate, , Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. (GF 5 + FF 2 = 07 Nos of : 2.0 TR )
Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of Regular Cassette Units Indoor with accessaries like required Cassette panel, support plate, , Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. (GF 1 + FF 1 = 02 Nos of : 2.5 TR )
Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of Regular Cassette Units Indoor with accessaries like required Cassette panel, support plate, , Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. (GF 5 + FF 4 = 09 Nos of : 3.2 TR )
Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of Regular Cassette Units Indoor with accessaries like required Cassette panel, support plate, , Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. (GF 4 + FF 8 = 12 Nos of : 4.0 TR
Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of High Static Duct Type Units Indoor with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc.4.0 TR
Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of High Static Duct Type Units Indoor with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 8.1 TR
Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Treated Fresh Air Type Units Indoor with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 3750 CFM/25 TR - 55mm wg Total static pressure ( GF 01+FF 01=2 Nos )
Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 1050 CFM / 20MM ESP - Exhaust Air Fan
Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 750 CFM / 20MM ESP - Fresh Air Fan
Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 650 CFM / 20MM ESP - Exhaust Air Fan
Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 500 CFM / 20MM ESP - Fresh Air Fan
Lifting, Shifting,Positioning, Installtion, Testing & Commissioning of Copper refrigerant joints with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc.
Lifting, Shifting,Positioning, Installtion, Testing & Commissioning of TFA Connection Kit with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws, cable termination with lugs, copper connection to kit etc.
Lifting, Shifting,Positioning, Installtion, Testing & Commissioning of Cordless Remote with baseplate, nut bolts, Washer & screws etc.
Lifting, Shifting,Positioning, Installtion, Testing & Commissioning of Corded Remote with cable termination with lugs, baseplate, nut bolts, Washer & screws etc.
Lifting, Shifting,Positioning, Installtion, Testing & Commissioning of Central Remote with cable termination with lugs, baseplate, nut bolts, Washer & screws etc.
Lifting, Shifting,Positioning, Installtion, Testing & Commissioning of TFA Starter Pane with cable termination with lugs,nut bolts, Washer & screws etc.
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : (C.) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : (D) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : (H) 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : (I) 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : (L) 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : (J) 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
SITC of Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.25mm ( 10 KG )
SITC of Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.32mm ( 10 KG )
SITC of Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.50mm ( 10 KG )
SITC of Control Cabling ( FOR ALL AIRCONDITIONERS ) 2.5 Sq.MM x 3C Shielded Control cabling with necessary conduiting between indoor and outdoor units
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required (A) Thickness 0.63 mm sheet (22 Gauge).
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required (B) Thickness 0.80 mm sheet (20 Gauge)
SITC of Duct line Acoustic Treatment High Density option (For low frequencies) : Duct acoustic lining material shall be Nitrile Rubber Open cell foam. Thermal conductivity of the insulation material shall not exceed 0.049 W/moK at an average temperature of 20oC. Density of the nitrile rubber shall be 200 ± 10% Kg/m3. The material should withstand maximum surface temperature of +85oC and minimum surface temperature of -20oC. The material should conform to Class 1 rating for surface spread of Flame in accordance to BS 476 Part 7 & UL 94 (HBF, HF 1) in accordance to UL 94, 1996. The insulation shall pass Air Erosion Resistance Test in accordance to ASTM Standard C 1071-05 (section 12.7), from an independent accredited testing agency. Thk- 13mm MAKE : Armacell / Aeroflex / K Flex
SITC of Duct line Thermal Treatment Thermal insulation material for Duct & Pipe insulation shall be Closed Cell Elastomeric Nitrile Rubber foam .Density of the nitrile rubber shall be 40-60 Kg/m3.Thermal conductivity as per ASTM C 518 of the insulation material shall not exceed 0.0352 W/moK at an average temperature of 10oC. The insulation shall have fire performance such that it passes Class 1 as per BS476 Part 7 for surface spread of flame as per BS 476 and also pass Fire Propagation requirement as per BS476 Part 6 to meet the Class ‘O’ Fire category as per 1991 Building Regulations (England & Wales) and the Building Standards (Scotland) Regulations 1990 The insulation material shall also be fire rated for Class V 0 as per UL 94. Water diffusion factor shall not be less than μ>7000 for plain sheets. Thk.-13mm MAKE : Armacell / Aeroflex / K Flex
SITC of Air Terminals Supply and Installation of Air grilles, diffusers & louvers, complete with all accessories, supports, anti smudge ring & removable core etc., to compete the work as per specifications, drawings and all related documents. Color to be confirmed with architect Make : Airflow / Sachins / Trox Air Grille with powder coated extruded & aluminium volume control damper
Supply and Installation of Air grilles, diffusers & louvers, complete with all accessories, supports, anti smudge ring & removable core etc., to compete the work as per specifications, drawings and all related documents. Color to be confirmed with architect Make : Airflow / Sachins / Trox GI Duct Volume control damper
Supply and Installation of Fire retardant canvass connection complete with all accessories, of Fire retardant canvass connection
MS FRAME WORK Providing Material & Labor for Fabrication Work For M. S. frame type structure for installing outdoor units duly epoxy coated / galvanized.
AMC of HVAC for 5 years after DLP : All in AMC Rates Applicable After Guarantee Period : Comprehensive AMC for the Full HVAC System for 1st Year after DLP Period (5% of Initial Cost) - Performance bank guarantee to be submit at time of Completion of work Scope of work to Operate & maintenance of the following Work Variable Refrigerant Volume air cooled Outdoor units incl.inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant Green Gas, VRV Cassette unit synthetic media pre-filter, fan section blower, multi speed motor, coil ,Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, VRV High wall type Indoor unit ,Precision AC, Toilet Ventilation Fans,Toilet Ventilation Fans, Starter Panel for TFA , UPVC drain pipe, Control Cabling, Duct line Acoustic Treatment, Air grilles, diffuser & louvers, M. S. frame type structure etc.
Comprehensive AMC for the Full HVAC System for 2nd Year after DLP Period (1st year + 5% of Initial Cost) - Performance bank guarantee to be submit at time of Completion of work Scope of work to Operate & maintenance of the following Work Variable Refrigerant Volume air cooled Outdoor units incl.inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant Green Gas, VRV Cassette unit synthetic media pre-filter, fan section blower, multi speed motor, coil ,Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, VRV High wall type Indoor unit ,Precision AC, Toilet Ventilation Fans,Toilet Ventilation Fans, Starter Panel for TFA , UPVC drain pipe, Control Cabling, Duct line Acoustic Treatment, Air grilles, diffuser & louvers, M. S. frame type structure etc.
Comprehensive AMC for the Full HVAC System for 3rd Year after DLP Period (2nd year+ 5% of Initial Cost) - Performance bank guarantee to be submit at time of Completion of work Scope of work to Operate & maintenance of the following Work Variable Refrigerant Volume air cooled Outdoor units incl.inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant Green Gas, VRV Cassette unit synthetic media pre-filter, fan section blower, multi speed motor, coil ,Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, VRV High wall type Indoor unit ,Precision AC, Toilet Ventilation Fans,Toilet Ventilation Fans, Starter Panel for TFA , UPVC drain pipe, Control Cabling, Duct line Acoustic Treatment, Air grilles, diffuser & louvers, M. S. frame type structure etc.
Comprehensive AMC for the Full HVAC System for 3rd Year after DLP Period (2nd year+ 5% of Initial Cost) - Performance bank guarantee to be submit at time of Completion of work Scope of work to Operate & maintenance of the following Work Variable Refrigerant Volume air cooled Outdoor units incl.inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant Green Gas, VRV Cassette unit synthetic media pre-filter, fan section blower, multi speed motor, coil ,Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, VRV High wall type Indoor unit ,Precision AC, Toilet Ventilation Fans,Toilet Ventilation Fans, Starter Panel for TFA , UPVC drain pipe, Control Cabling, Duct line Acoustic Treatment, Air grilles, diffuser & louvers, M. S. frame type structure etc.
Comprehensive AMC for the Full HVAC System for 5th Year after DLP Period (4th year+ 5% of Initial Cost) - Performance bank guarantee to be submit at time of Completion of work Scope of work to Operate & maintenance of the following Work Variable Refrigerant Volume air cooled Outdoor units incl.inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant Green Gas, VRV Cassette unit synthetic media pre-filter, fan section blower, multi speed motor, coil ,Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, VRV High wall type Indoor unit ,Precision AC, Toilet Ventilation Fans,Toilet Ventilation Fans, Starter Panel for TFA , UPVC drain pipe, Control Cabling, Duct line Acoustic Treatment, Air grilles, diffuser & louvers, M. S. frame type structure etc.
Passemger Lift : 8 Passemger : Providing & fixing 8 Passemger Lift of TRIO make Gearless MRL 8 Pass Model No TR-SMS1 with Microprocessor Based Controller With VVVF Operation , Down collective Simplex operation with drive power 400 Volts 3 Phase 50 Hertz A. C. Light Supply:230 Volts,50 Hertz Single Phase Machine room less Same side car entrence, Automatic Telescopic Opening,Hair line SS car Door,Automatic Telescopic Opening Landing Door,SS At All landing, SS Car Panels, SMFC1 False ceiling with LED Light,Blower Vantilation for car , PVC Flooring SMFL1, SMHR2 , at Back side 1 nos Round SS Hand rail with Hair line Finish & COP Detail - Push Button type SMCP2 at standered Height,7 Segment Display in COP , LOP & Hall indicator Push Button type SMCP2 in Wall Posion in LOP ,7 Segment, with Standard Control Functions / Features: included Digital Floor Position Indicator in Car and at all floors,Multibeam door censor Door Open/Close Buttons In Cop Alarm Button In COP (With Battery Back-Up), Emergency Light In Car, Between Car & Ground Floor Intercom,with Auto Rescue Device In Case Of Power Failure, Overload Function With Audio/Visual Indication,Fireman Control,Auto/Attendant operation,Auto/Manual Fan On/Off,Optional Control Functions : Standered Voice Announcement system ,Power Saving function for LED Lights and Displays Etc Specs From Trio & Complete Installation
Passemger Lift 10 Passemger : Providing & fixing 10 Passemger Lift of TRIO make Gearless MRL10 Pass Model No TR-SMS1 withMicroprocessor Based Controller With VVVF Operation , Down collective Simplex operation with drive power 400 Volts 3 Phase 50 Hertz A. C. Light Supply:230 Volts,50 Hertz Single Phase Machine room less Same side car entrence, Automatic Telescopic Opening,Hair line SS car Door,Automatic Telescopic Opening Landing Door,SS At All landing, SS Car Panels, SMFC1 False ceiling with LED Light,Blower Vantilation for car , PVC Flooring SMFL1, SMHR2 , at Back side 1 nos Round SS Hand rail with Hair line Finish & COP Detail - Push Button type SMCP2 at standered Height,7 Segment Display in COP , LOP & Hall indicator Push Button type SMCP2 in Wall Posion in LOP ,7 Segment, with Standard Control Functions / Features: included Digital Floor Position Indicator in Car and at all floors,Multibeam door censor Door Open/Close Buttons In Cop Alarm Button In COP (With Battery Back-Up), Emergency Light In Car, Between Car & Ground Floor Intercom,with Auto Rescue Device In Case Of Power Failure, Overload Function With Audio/Visual Indication,Fireman Control,Auto/Attendant operation,Auto/Manual Fan On/Off,Optional Control Functions : Standered Voice Announcement system ,Power Saving function for LED Lights and Displays Etc Specs From Trio & Complete Installation Intent Specification : 1) This specification covers the minimum requirements for the complete design, material, manufacturing, shop inspection, performance testing at the manufacturer’s works, delivery at site, and erection & commissioning of Elevators along with accessories which is to be furnished in the Flue Gas Desulphurization plant. 2) Contractor shall assume full unit responsibility for the entire equipment assembly and make all possible efforts to comply strictly with the requirements of this specification and other specifications/attachments to inquiry/order.3) All accessories, items of work, though not indicated but required to make the system complete for its safe, efficient, reliable and trouble free operation and maintenance shall also be in supplier’s scope 4) Design, engineering, manufacture, inspection, delivery, erection, commissioning and handing over. ii) Maintenance & services during guarantee period. iii) Necessary erection / commissioning spares and consumables shall be included in Contractors scope. iv) Necessary tools and tackles required for maintenance, testing and inspection shall be covered in vendor scope. v) Necessary chain and pulley block along with hand operated geared trolley arrangement for horizontal movement across.5) the monorail, hoist, rope and hook arrangements at the machine room ceiling to carry out the maintenance and erection of equipment shall be supplied by Elevator vendor. The necessary mono-rail beam will be supplied by Contractors Scope . vi) A steel ladder for access to the pit shall be supplied by the Elevator vendor. vii) Guard to protect the hoist way including temporary barricades at hoist way openings shall be supplied by Elevator vendor. viii) Scaffolding as per erection requirement shall be provided by the Elevator vendor. After completion of handing over activities, the scaffolding materials may be taken back by the vendor. ix) All the electrical equipment including Lift well, Hoist way lighting with fittings, Power/control/trailing cables, MCCB/MCB & ELCB for 415 V AC 3ph supply (to receive the incoming feeders provided by customer) shall be included in the Elevator vendor scope. x) The vendor shall assume all responsibility for proper design and operation of each and every component of the elevator as well as the elevator as a whole. Complying with Indian electricity rules & Indian electricity acts and applicable statutory requirements (of Government of India and applicable States) as well as procedural formalities also shall be taken care by the Elevator vendor.
C E INFRA (INDIA)
Anand Associates
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid