| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC SHIV BHAWAN MAGADH COLONY ROAD NO 03 SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | GAYA | BIHAR | 823001 | ₹1.2 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.4 Cr+₹19.9 L (16.3%)Rejected-Finance | ₹1.4 Cr+₹19.9 L (16.3%) | L2 | Rejected-Finance Being other than Lowest |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
4 Dec 2021, 6:00 pmClosed
CWE Ranchi
HQ CWE RANCHI MES DIPATOLI CANTT PO RMCH RANCHI - 834009
SPECIAL REPAIR RENOVATION OF 21 UNIT STAFF QUARTERS IN KV No 2 GAYA
2021_MES_484399_1
80599/1383/E8
Open Tender
Civil Works - Others
Item Rate
180 days
Gaya
Class B category a(i)
6 documents required · 6 mandatory
₹1,000
Yes
GE Gaya
₹2.0 L
Yes
20 Dec 2021
30 Oct 2021
6 Dec 2021
30 Oct 2021
4 Dec 2021
22 Nov 2021
Amount
M & L for vitrified ceramic tiles light shed 10 mm thick ( square or rectangular) polished, area of each tiles not exc 0.36 sqm, in floors etc. set and jointed with cement and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with CM 1:4 complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. all as specified and directed.
M & L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but not exceeding 0.11 sqm each, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over & including 15mm thick screed bed or bedding layer with CM 1:4 complete all as specified and directed.
M & L coloured digital Glazed ceramic coloured tiles in vertical surfaces 450 x 300 x 7-8 mm set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces as backing for tiles including taking down old tiles complete all as specified and as directed.
S & F Powder coated aluminium frame/shutters for windows, ventilators sliding/openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws, etc complete all as specified. Make : JINDAL/HINDALCO/INDALCO. Note : (i) Glazing and wire mesh shall be measured and paid separetely only as the labour element included in the relavent item. (ii) Item shall be paid as per weight of aluminium section (iii) The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight (iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing.
S & F 19/20 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work in cup board and pelmet boxes etc. complete all as specified and directed.
S & F continuous (Piano) hinges,mild steel, bright finish or electro galvanised, width of flaps (when open) 30 mm complete all as specified and directed.
M & L for 35 mm thick Flush shutters, solid core construction, with block board core and 5 mm thick plywood face panels on both side, commercial type on both sides covered face veneered decorative type etc.
M & L for pressed steel door frame size 105 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc., complete, all as specified.
M & L for pressed steel door frame size 165 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc., complete, all as specified.
M&L for providing PCC 1:3:6, type C-0 (using 20 mm graded stone aggregate) as in filling of pressed steel door frame and holdfasts including necessary formwork etc. complete all as specified and directed.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.18mm and fixed with beeding/Staples complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden or steel frames glazed all as specified and directed
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares of any size n. exc 0.50 Sqm each pane complete all as specified and directed
S&F 4mm thick figured glass pin headed type and glazing with oil putty or wooden beads in squares n exc 0.50 Sqm each pane complete all as specified and directed.
S&F as in repair 15 mm dia bore bib taps, cast copper alloy chromium plated fancy type with crutch alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm dia stop valves/angle valve, cast copper alloy,fancy type chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and directed..
S&F PVC connections 15mm size with PTMT nuts of length 600 mm all as specified and as directed.
S&F in repair CP health faucet 15 mm with flexible tube of stainless steel provided rubber hose and wall hook etc complete all as specified and as directed
S& F PVC ( SWR ) nahani ntrap / floor trap 75 mm dia all as specified and as directed.
S&F in repair 25 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed
S&F in repair 15 mm dia two way angle valves/Bib taps, cast copper alloy,fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed
Supply & fix in repair brass chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed
Supply & fix in repair brass chromium plated wall mixer (2/3 hole) with provision for connection to shower rose for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed .
S &F as in repair chromium plated shower rose 125 mm dia with 300mm CP shower arm fancy type fixed to 15mm bore pipe all as specified and directed .
S & F brass chromium plated tublar towel rail 20 mm dia D type 600mm long between flanges with CP screws etc complete all as specified and as directed
S & F in repair gun metal gate valves, with iron wheel head, screwed both ends for iron pipe flange ends type fixed of 20mm diacomplete all as specified and as directed
S&F PVC waste pipe size 32 mm X 800 mm flexible with coupling for Urinal/WHB/Sink etc. complete all as specified and directed.
S & F in repair 100 mm/ 125mm dia mild steel chromium plated grating (double Q) fixed on floor trap / nahani trap in Cement mortar 1:6 , all as specified and directed .
S & F Male Brass Threaded Adaptor (MTA/ MBTA/Female Brass Threaded adaptor (FTA/ FBTA) suitable for 20 mm outer dia of pipe complete all as specified.
S & F CPVC pipes 20 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed
S & F CPVC pipes 25 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed
S & F in repair rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) capacity 1000 Ltr (three layers ) hoisted and fixed in position all as specified and directed .
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work using old size bricks with fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 10mm thick internal surfaces on fair faces of brick work in CM 1:6, finished the surface even and fair without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick external surfaces on brick/concrete in CM 1:4 , finished the surface even and fair without using extra cement mixed with liquid water proofing compound @ 200 ml per bag of cement or as per manufacturere's instructions complete all as specified and directed. Note:-WPC shall be measured and paid separatly
M&L for applying 2.00 mm thick wall care putty in two coats incl preparation of newly plastered wall surfaces complete all as specified and directed.
M&L for applying 2.00 mm thick wall care putty in two coats incl preparation of old plastered wall including complete removal of existing treated surfaces all as specified and directed.
M&L for applying two coat of acrylic distemper over a coat of primer incl preparation of putty plastered wall surfaes complete all as specified and directed.
M&L for applying two coat of acrylic distemper as in ceiling incl removal of existing treatment of old treated ceiling surfaces complete all as specified and directed.
M&L for 2 coats exterior weather coat dust proof paint over a coat of primer including preparation of newly plastered or old treated surfaces including complete removal of existing treatment complete all as specified and directed
Demolition of cement concrete (unreinforced) in ground floors and pavings including floor tiles n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for Cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate), 25 mm thick in flooring etc complete all specified and as directed
M & L for 75 mm thick Cement concrete type C- 1, 1:3:6 (using 20mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for granite (any type) work (table rubbed and polished) 18 to 20 mm thick in working platform and like including cutting for sink etc. set in cement mortar (1:4) including rounding of edges and pointing in white cement (1:2) using marble dust with admixture of pigment to match.complete all as specified.
M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of new steel surfaces complete all as specified and directed.
M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth including preparation of old steel surfaces complete all as specified and directed.
M & L for TMT reinforcement bars 8 mm dia cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L RCC type B-1, 1:2:4 (using 20 mm graded stone aggregate) in slabs, cantilever or supported on walls and small works like cubes etc. complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe etc complete all as specified and directed
S&F PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) bends ISI marked any radius of 75 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or un equal of 110 mm bore of pipe with access door complete all as specified and directed
PVC (SWR) vent cowl for 110 mm bore pipe complete all as specified and directed
S&F Stainless steel medium grade handles, D shape of size 150mm complete. ISI marked complete all as specified and directed
S & F 200mm long Stainless steel medium grade barrel tower bolt ISI marked complete all as specified and directed
S & F alluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple (bolt type) with fixing clips and bolts and 300 mm long complete all as specified.
S & F in repair sinks made of stainless steel 1.00mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
S & F in repair vitreous china wash basin oval shape white flat back size 550 x 400mm waste, chain & plug and porcelain stopper but including brackets or fixed to walls with anchor fastners all as specified and directed .
S & F in repair Vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts, but excuding flushing cistern and flush pipe complete complete all as specified and directed
S & F in repair 10 litre capacity PVC valveless, syphonic action type flushing cistern (Dual type) , low level, white, with inlet, ball valve, float and handle including brackets complete complete all as specified and directed
S & F in repair soft closing white Seat Cover for EWC incl accessories complete complete all as specified and directed
M & L for repair of sunken slab as under :- (a) M & L for application of 1:3 cement – sand mortar, mixed with Sika Latex emulsion (300 gram in 1 Kg cement), as a coving at the corners of floor and the vertical surface in the sunken area and between floor and walls in the remaining area. (b) M & L for application of Sika Top Seal 109hi @ 2.20 Kg per Sqm each coat or as per manufacture instruction– acrylic based, ready to use, cementitious, water proof coating onto the prepared surface in a continuous film on the floor of the sunken area, taking the coating over the vertical surfaces on to the floor and over the coving on to the wall (before tiling) to at least 300mm above the final finished floor level. The coating shall also be continued on to the inner surfaces of the pipe penetration holes. Two coats shall be applied & fiber Glass Cloth to be laid in between coats. (c) M & L for application of Sikagard 694 F (I) @ 100 gram per Sqm or as per manufacture instruction, a moisture insensitive epoxy putty in a continuous, 10mm thick gasket around the pipes to a width of approximately 15mm. (d) M & L for application of protective screed concrete at a desired thickness admixed with Sika Cim Pink @ 100 gram per Sqm or as per manufacturer instruction
S & F Stainless steel butt hinges, medium weight cold rolled of size 100 mm complete all as specified and directed
S & F 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed
S & F 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed
Taking down chowkhats or frames not exc 1.5 Sqm each ( with shutter without taking shutters from the frame). complete all as specified and directed
Taking down chowkhats for frames exc 1.5 Sqm but n exc 4.00 Sqm (with shutter without taking shutters from the frame) complete all as specified and directed
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet & edges will be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed
S & F Solid PVC factory made Door shutter of 30mm (style) consisting of frame made out of MS tubes for top bottom rails MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having a PVC sheet strip 20mm width stuck inside with solvent cement for stilesa and plain coloured PVC sheets for top rail, lock & bottom rail on either sides & as gap insert for top rail & bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beeding and jointed together with solvent cement as pere specification and drawing
M&L for providing water proofing treatment over cleaned roof surfaces with super thermo APP modified water froofing membran comprssing of following for non-approachable roof: (i) Removal of existing roof treatment and cleaning sweeping and washing and down with water to remove all dust etc from plastred roof surfaces/wall and filling of crack with sealing compound etc. (ii) Bitumen based primer conforming to IS 3384-1965 at 0.30 kg per sqm. (iii) One layer of super thermo APP modified water proofing membran with non polyster reinforcement of Make (M/S STP texsa Ltd/hyperplus membrane of M/S IWL India Ltd. M/S STP and Tikki Tar Ltd ) 3mm thick and minimum weight @ 3.50 Kg/sqm laid with gas torch and fasted on roof surfaces with roller. The over laps shall be sealed by flame including vertical surfaces after cutting necessary grooving and making good with PCC gola 1:2:4 type B1 etc adhere to bitumen all as per manufacturer instructions. (iv) Applying two coat of aluminium paint @ 0.20 kg/sqm per coat over bitumen layers as per manufacturer instruction (application including side lap overlaps shall be provided not less than 10cm and jointed sealed with torch as per manufacturer instruction specification.
Supply only Liquid water proofing compound complete all as specified.
M & L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and no pigment complete all as specified and directed.
Sand filling under floors for cushioning of including watering and consolidation complete all as specified and directed
M & L for Providing, cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work all as specified and as directed
Excavation in trenches n exc 1.5m wide n exc 1.5m depth; for foundations, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of pipes / cable etc.n exc 10sqm on plain and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed
Excavation in trenches n exc 1.5m wide and exc 1.5m but n.exc 3.00 mtr depth; for fdn, etc. or for shafts, wells, cesspits, manholes, pier holes etc.n exc 10sqm on plain and getting out in soft/loose soil complete all as specified and as directed
M & L for PCC type B1, 1:2:4 (20mm graded aggregate) as in coping on brick drains including weathering, slightly rounded or chamfered angles and throating as directed complete all as specified and as directed
M & L for extra for forming fair finished drain or channel 30cm inner girth using extra cement incl forms moulds mitered /stopped ends etc. complete all as specified and as directed
S & F factory made precast HD-20 heavy duty rectangular SFRC ventilating cover and frame of clear opening of size 0.90 mtr x 0.45 mtr and 1.20 x 0.75 mtr confirming to IS 12591 : 2002 complete all as specified and directed.
S & F of DWCPE (SN8) 180 (OD)/163(ID) mm diameter Pipes and testing of sewage line including all items/fittings and activities to execute and make sewer line functional complete all as specified and as directed
M & L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes of 150 mm dia of pipe including packing under, and haunching against the sides of pipes after they are laid and tested.complete all as specified and as directed
Excavating over areas n exc 1.5m in depth for foundation etc. and getting out in in hard/dense soil complete all as specified and as directed
Excavating over areas exc 1.5m but n.exc 3.00 mtr in depth for foundation etc. and getting out in in hard/dense soil complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm in soft/loose soil complete all as specified and as directed
Removing excavated soil to a distance n exc. 50m & depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed
M&L PCC (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundations, filling and mass concrete complete.all as specified and as directed
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter Rough finished surfaces of concrete flat all as specified and as directed
M&L RCC M-30 design mix using 20 mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed
Use and waste formwork to faces of walls, retaining walls, abutments, parapets & staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to better of rough finished surfaces of concrete.complete all as specified and as directed
Use and waste for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick horizontal flat surfaces of concrete complete all as specified and as directed
M&L RCC M-30 design mix using 20 mm graded aggregate in walls, basement walls and the like; any thickness; above top of footings; incl attached pilasters and buttresses complete all as specified and as directed
M&L RCC M-30 design mix using 20 mm graded aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed
M&L Rendering 10mm thick on fair faces of concrete surfaces in ceiling in CM (1:4) finished even and smooth with using extra cement with WPC as per manufacturer instruction complete.all as specified and as directed. Note : WPC will be measured and paid separately complete.
M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality
S & F of PVC (SWR) 110 mm dia junction single, (Single T) equal or unequal complete all as specified and directed
M & L brickwork with subclass 'B' bricks, in one brick thick honey comb walling built in CM 1:4 complete all as specified and directed.
M & L brickwork with old size subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 as in wall of soakage well, man holes etc complete all as specified and directed.
Excavating in post holes (or similar holes) in hard/dense soil each not exc. 0.5 cum, getting out. returning, filling in and ramming earth or broken rubble mixed with earth around. in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exc. 50 m and making good surface complete all as specified and directed.
Excavation in trenches n exc 1.5m wide and not exc 1.5m in depth; for fdn, etc. or for shafts, wells, cesspits, manholes, pier holes etc.n exc 10sqm on plain and getting out in hard / dense soil complete all as specified and as directed
Use and waste for formwork to sides of pillars. posts, square or rectangular columns etc, rough finished surfaces of concrete. complete all as specified and as directed
M&L RCC M-25 design mix using 20 mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed
M&L RCC M-25 design mix using 20 mm graded stone aggregate in columns, pillars offers. costs and struts etc.complete all as specified and as directed
M&L for mild steel TMT bars 6mm, to 8mm dia as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed
M & L for rendering 15mm thick on brick work masonry or concrete surface of walls in CM 1:4, surface finished even and smooth surface without using extra cement complete all as specified and as directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed
Supply only Chain link MS galvanisd fencing 50mm x 50 mm mesh and 4.00 mm dia acomplete all as specified and as directed.
S & F of Mild steel framed work as in doors , grills, gratings. gate etc with ends of bars shouldered and /or riveted and similar work confirming to Fe 290 0-de E-165 complete all as specified and as directed
S&F mild steel work in post & struts in fencing including cutting tips to shape as directed. drilling holes. notching for wire etc. including flat iron fillets for securing wire mesh etc including all necessary drilling bolting or riveting of and similar work conforming Fe-290 Gde E-165.complete all as specified and as directed
S & F Miid steel bolts, purpose made, with: hexagonal or 'Square head one end and screwed the other. or screwed both ends: exc 30cm long (Diameter of neck in n exc 12mm) complete all as specified and as directed
Taking down aluminium point wiring (light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, light fittings, regulators, sockets etc. removing materials to store, or keeping in safe custody for re-use at site or offering credit and making good disturbed surfaces of walls, floors, etc. to match with the existing complete all as specified and as directed.
Taking down old unserviceable distribution board SPN / TPN DB, Main Switch by disconnection of electric connection including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
Taking down copper/aluminium sub main wiring of any size or type surface/ concealed including conduit from any height and removing from site and making good disturbed surfaces of walls, floors, roofs etc cto match with the existing complete all as specified and as directed.
Taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to MES store yard of AGE E/M Gaya complete all as specified and as directed.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electric connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M Gaya complete all as specified and as directed.
M&L for point wiring complete with PVC insulated unsheathed FR multistranded copper conductor cable conforming to IS : 694 of size 1.5 Sqmm two single core drawn through in and including PVC conduit pipe not less than 20mm dia medium grade ISI marked complete with one run of PVC insulated unsheathed multistranded copper conductor FRLS cable 1.5 Sqmm single core green colour earth wire and connecting to earth dolly incl colour coding of cable shall be for phase, neutral and earth wire as specified in MES SSR Part-I 2009 with provn of galvanized sunken box not less than 1.12 mm thick MS sheet pressed terminal boxes concealed on wall, with 3 mm thick laminated sheet top cover ISI marked. Make: Hylum/Anchor for fixing of switches/ socket/ regulator with screws complete including making good of disturbed surfaces of wall/ ceiling/ floor area in same specification as per existing all as specified and directed for the followings :-
One light/fan/bell point controlled by one switch.
One 5 pin socket outlet 5 Amps independent board.
One 5 pin socket outlet 5 Amps on the same board with other switch.
One light point controlled by two way switches.
M&L for point wiring for one socket out let point complete with PVC insulated and unsheathed cable FRLS 2.5 Sqmm multi stranded copper conductor cable conforming to IS:694, two single core drawn thorugh and including 20mm dia PVC conduit medium grade ISI marked in concealed in wall 1.60 mm thick pressed steel concealed terminal boxes and with top cover 3 mm thick ISI marked plastic laminated hylum sheet fixed with brass screws and cup washers painting terminal boxes inside and out side with one coat red oxide primer compete with all accessories and all as specified including one run FRLS 2.5 Sqmm PVC insulated unsheathed multistranded copper conductor to common earth and connected to earth dolly including colour coding of cable as specified in SSR Part-I (2009) & making good disturbed area of wall with cement work & white wash etc to match with the existing surfaces, complete all as specified and as directed .
S&F switch piano flush button single pole one way 5 amp complete all as specified & directed
S&F ceiling rose surface bakelite 65x50mm 2 to 3 terminal complete all as specified & directed
S&F socket outlet 2-in-1, 5 pin, 6 Amps flush type complete all as specified & directed
S&F for switch socket combination 2-in-1, 5 pin, 6 Amps flush type complete all as specified & directed
S&F lamp holder, PVC/ Polycarbonate type with back plate for batten/ angle fitting including LED bulb 12 watt complete all as specified & directed
S&F switch socket combination 2-in-1, 3 pin, 6 and 16 amp flush type universal complete all as specified & directed
S&F bell Push, flush type, 6 Amps complete all as specified & directed
S&F buzer, Ding Dong AC, 230 Volt, single Pole complete all as specified & directed
S&F mirror LED tube light fitting 1x10 watt 2' long with complete accessories including connecting up with three core flexible wire as suitable size with complete all as specified & directed
S&F switch piano flush button single pole two way 5 amp complete all as specified & directed
S&F MCB Distribution board double door made out of CRCA mild steel sheet surfce with insulated material like polyester or with epoxy powder coating and IP-43 & IK-09 protection surface/concealed mounting TPN 4 way, 440 volts with bus bar rating 200 Amps (vertical operation) and suitable size of cable gland -02 Nos, dust and vermin proof suitable for incorporation of MCCB 4 pole 63 amps 16 kA and MCB's and making all necessary connections complete all as specified and directed at site. Note : The cost of MCCB and MCB, isolators shall be measured and paid seperately.
S&F sheet metal enclosure distribution board SPN, 8 ways 240 volts, with 200 amps rated bus bar with IP-42 protection and double door, suitable for mounting MCBs all as specified and as directed including taking down old MCB DB complete.
S&F MCB single pole and neutral, 240 volts, 40-63 Amps, all as specified and as directed.
S&F MCB single pole, 240 volts, 5 to 40 Amps, all as specified and as directed.
S&F MCCB 4 pole, 63 Amps with breaking capacity 16 KA, 415 volts complete all as specified and directed.
S&F sheet metal enclosure for single pole and neutral with two pin and earth plug top and socket complete with one single pole MCB 20 Amps complete all as specified and directed. Make: ABB/Legrand/Havells
S&F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make : Havells Cat part No LUMILINEPLUSBS20WLED865SPCSS OF 20W or its equvalent in Philips, Crompton Greaves.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion including taking out exisitng earthing system complete all as specified and directed.
M&L in replacement sub main wiring complete with two runs of 6 sqmm single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls / roofs / floors etc., with one run of 4 Sqmm single core multistranded copper conductor as earth continuity conductor complete all as specified and directed. Note:- One run of conduit two run of 6 sqmm copper condictor & one run of 4 sqmm copper conductor is measured as one unit.
M&L in replacement sub main wiring complete with two runs of 4 sqmm single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls / roofs / floors etc., with one run of 2.5 Sqmm single core multistranded copper conductor as earth continuity conductor complete all as specified and directed. Note:- One run of conduit two run of 4 sqmm copper condictor & one run of 2.5 sqmm copper conductor is measured as one unit.
S&F 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, B class insulation comprising of electronic fan regulator, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding fan motor having power factor not less than 0.9, minimum service value 3.5 CMM/W, Air delivery minimum 210 CMM as per IS-374:1979 (amended upto Mar 2002) including safety pin, nut bolts, washers, suitable for 230 V, 50 Hz, single phase AC supply complete all as specified and directed. Make: Havells/Usha/Khaitan/ CG
S&F exhaust fan single phase 300 mm sweep, 1400 RPM, 240 Volts, AC with and including louvers, mounting rings, MS fastner bolt, washers etc and connecting from ceiling rose / connector with and including suitable size flexible copper conductor PVC insulated sheathed chord and duly making holes complete all as specified and directed at site. Make :Havells/CG/Bajaj.
S&F vertical storage type electric water heater 25 Ltr capacity, steel body, copper inner tank and heating element upto 2 KW capacity, 230 Volts, BEE 5 star rated with all accessories such as safety valve, thermostate, NRV, connection piece etc, fixing on wall through proper nut, bolt, and fastner including electric and water connection complete all as specified and directed. Make: Havells/Bajaj/CG/ Racold
S&F building security light fitting 35 W LED new generation energy saving & environmental friendly long life LED security light made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having top opening including driver compartment driver with IP-66 protection and impact resistance of IK-07 including fixing with 32mm dia light grade GI bracket not exc 1.5 mtr length made to shape & fixing on pole/wall with 2 nos of MS clamp including necessary connection from building ceiling rose complete all as specified and directed. Make: Havells/Crompton/Bajaj.
Taking down and re-fixing and connecting electric meter electronic type up to 25 Amps complete all as specified and as directed.
Taking down existing old unserviceable cable of any description and size complete all as specified and directed.
Taking down existing old unserviceable street light/flood light/post top fitting of any description and size complete all as specified and directed.
Supply and laying cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of following size complete all as specified and directed by Engr-in-charge. Note: Excavation, earth work and cable protection shall be measured and paid seperately.
95 Sqmm 3.5 core
25 sqmm 4 core.
10 sqmm 4 core.
M&L for laying of HDPE double wall corrugated pipes in trench for UG cable protection conforming to IS-14930 Part-II with IP-67 having outer dia 40 mm and inner dia of 32 mm including necessary fittings such as couplers, bends etc complete all as specified and directed.
M&L for laying of HDPE double wall corrugated pipes in trench for UG cable protection conforming to IS-14930 Part-II with IP-67 having outer dia 50 mm and inner dia of 38 mm including necessary fittings such as couplers, bends etc complete all as specified and directed.
M&L for laying of HDPE double wall corrugated pipes in trench for UG cable protection conforming to IS-14930 Part-II with IP-67 having outer dia 75 mm and inner dia of 63 mm including necessary fittings such as couplers, bends etc complete all as specified and directed.
S&F GI tubing 50 mm dia light grade with all fittings laid in trenches/road/along poles for cable protection complete as specified directed
M&L for painting of pole LT (up to 9 mtr long) after cleaning the complete body surface of pole by rubing with emery paper to remove old paint, dust etc and applying one coats of aluminium paint by brush incl cross arm, channel, nut & bolt etc and black colour for 1 Mtr from bottom complete all as specified & directed by Engr-in-charge.
M&L for earthing complete with galvanized iron earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.6 meter below normal ground level connected to galvanized earth strip of (32x6)mm by means of bolts, nuts, check nuts, galvanized iron or steel all as shown in Electrical plate No. 5 of MES sch pt I testing on completion with & including 40 mm bore medium grade GI protection pipe 7.5 mtr long for earth lead, PCC (1:3:6) type C1 pit with pre cast RCC (1:2:4) cover slab 40mm thick reinforced with 6mm dia MS bars @ 100mm c/c both ways, watering arrangement with funnel, wire mesh 20 mm bore medium grade GI pipe, common salt & char coal fixing necessary excavation earth work complete. (GI pipe & GI wire beyond 7.5 mtr will be measured and paid respectively)
S&F LED street light fitting 70 Watt 230 Volt AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including necessary electrical connections from Junction box to fitting terminal with 3 core 2.5 sqmm cable. Make: Havells/Bajaj/CG/Phillips
M&L PVC Junction box of size 340mm x 285mmm x 120mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and outgoing cable/wire complete comprising of aluminium bus bar for 3 phases & neutral, insulated with insulators, including colour coding and 01 Nos MCB 06 Amps complete all as specified and directed. Make: Sintex Model : GSMB-3428/ National Model No: NJB3020 / Mahindra Composits
m/s meetu enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .